Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear Criticality Safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Critical and Subcritical Californium Source Driven Noise Analysis Experiments with Fresh PWR Fuels Pins

These experiments were performed in 1983 between August 1 and September 16 and used 35 operational days of critical facility time at the Babcock & Wilcox critical facility in Lynchburg, Va. These measurements were to assess the capability of the Cf source driven noise analysis method to measure the subcriticality of light water reactor fresh fuel configurations. This report documents the experiments of 1983 that were not reported at that time. These measurement with 2.459 wt. % 235 U enriched uranium oxide fresh fuel pins started at the delayed critical configuration of the fully assembled pressurized water reactor (PWR) core configuration with 1511 parts per million (ppm) natural boron (19.8 wt. % 10 B) in the water. This was a cylindrical configuration of 4961 fuel pins. After the initial measurements at delayed criticality, subcritical measurements by the Cf source driven noise analysis method were performed in which the number of detectors and Cf source locations were varied. Additional boron was added to the water moderator and reflector to reduce the neutron multiplication factor, with resulting boron concentrations of 1561, 1613, 1765, 1880, 2104, 2384, 2975, 3606, and 4303 ppm. After the completion of these measurements the increased, the boron concentration was returned to that at delayed critical (1511 ppm) and the reactivity was decreased by reducing the number of fuel pins in steps to 3713, 2553, 1281, 749, and 333 fuel pins and then to that (289) of a s ingle square 17 x 17 pin array, corresponding to a single PW fuel element. For all measurement that started at delayed criticality and then reduced the neutron multiplication factor to various subcritical states, inverse kinetics rod drop measurements at the higher reactivities were also performed but not reported here. At all subcritical states the break frequency noise analysis data was fitted to obtain the prompt neutron decay constant. Some data presented in this report are from notes not in the logbook. The purpose of this report is to document the experimental information for the measurements performed so that a later date someone could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (INCSBEP) or Nuclear Energy Agency (NEA) benchmark. The data from these measurements is available from the Laboratory Records Department of Oak Ridge National Laboratory and the logbook is available from INCSBEP at Idaho National Laboratory.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Summary of LANL Critical Benchmark Comparison Study and Revisions for Cases Involving HEU, LEU, MIX, and Pu

This report documents results obtained for revisions made to cases involving Highly Enriched Uranium (HEU), Intermediate Enriched Uranium (IEU), a mixture of Pu and Uranium (MIX), as well as Pu cases. A previous summary of revisions for HEU an Pu cases was reported and additional investigations into four cases originally presented therein uncovered further revisions which led to better agreement with other transport codes, those cases are updated in this report. The summary of all cases reported in Reference 2 is updated in this report. In addition, a previous summary of revisions for LEU and MIX was reported, a summary of those revisions in reproduced in this report for a comprehensive summary of changes to benchmarks beginning in fiscal year 2020 to current date. The report focuses on the changes made to LANL benchmarks modeled with MCNP6 using ENDF/B-VII.1 nuclear data that appeared to have discrepant results when compared with results of other codes. Feedback was used to pinpoint review of benchmark input files and to revise them when necessary. This report documents the results of review and revision of specific benchmarks highlighted as possibly discrepant in the comparison study. In addition, there is an effort tied to this work involving collaboration between LANL XCP and NCS Divisions in the development of a shared review/revision procedure and use of a new benchmark repository. LANL has a benchmark library of critical experiments from the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook modeled for use with MCNP. This collection is now over 1100 benchmarks, referred to as the Whisper-1.1 library because it is used with the sensitivity/uncertainty package, Whisper, which supports nuclear criticality safety validation and is released with MCNP6.2. The collection, originally created several decades ago, is a combination of smaller collections, which has been revised and expanded, by various groups at LANL over the years. The original authors are no longer at the laboratory and little formal documentation of review and revision of these benchmarks exists today. A branch of the benchmark collection was already the subject of a formal review undertaken by the LANL NCS Division and expanded to include XCP Division.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Consistent Nuclear Data Evaluations for Criticality Safety [Slides]

This presentation covers consistent nuclear data evaluations for criticality safety. Topics include the evaluation procedure, n+ 139 La evaluation, the work in progress for the n+ 233 U evaluation (emphasis on capture), and a concluding Summary.

07 ISOTOPE AND RADIATION SOURCES↗

Applying Methodology for Evaluating and Validating TSLs to Materials of Interest to NCSP [Slides]

This presentation covers the topic of applying methodology for evaluation validation of TSLs to material of interest to the Nuclear Criticality Safety Program (NCSP). The talk covers recent efforts in validating thermal neutron scattering cross sections. The presentation also proposes a methodology for not only validating thermal scattering files that utilizes all available experimental data, but also for evaluating new libraries as demonstrated on Polystyrene and Lucite

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ANS-8 Subcommittee Forum [Slides]

This presentation goes over membership of ANS-8 subcommittee (SC) and WGs. Additionally discussed is ANS-8 SC and NCSCC ballots for ANS-8 standards since the last meeting, ANS-8 business, ISO TC85/SC5/WG8 September Meeting – quick summary. Working Group Chair Reports, ISO TC85/SC5/WG8 “Nuclear Criticality Safety” committee, and How to volunteer/participate.

ANS-8 Standards↗

FY22 NCSP accomplishments for U and Pu Evaluations [Slides]

This presentation covers fiscal year 2022 for Nuclear Criticality Safety Program (NCSP) accomplishments for Uranium (U) and Plutonium (Pu) evaluations. This presentation includes an overview on plutonium and uranium. Additionally, this presentation covers the inclusion of sub-thermal data for 235 U and the inclusion of LANL ratio capture-to-fission data for 233 U and 235 Pu. The presentation ends with a discussion on 239 Pu Primary fit of Mosby's data as reported and a look at the uncertainty quantification.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

140,142 Cerium Resolved Resonance Region Evaluation [Slides]

The presentation covers an overview of 140,142 Ce Isotopes, including new evaluations of 140,142 Ce that were requested by the Hanford Plutonium Finishing plant to the Nuclear Criticality Safety Program. It also discusses current ENDF/B-VIII.0 evaluation, which has an error in the 1-2 keV range. It was evaluated using multi-level Breit-Wigner and 142Ce has room for extending resolved resonance region current upper limit from 13 keV. The presentation also discusses new transmission and capture measurements of nat Ce and 142 Ce from Klaus Guber. It also states that no known integral experiments prominently feature Cerium.

07 ISOTOPE AND RADIATION SOURCES↗

Subcriticality Measurements for a Changing Concentration Uranyl Nitrate Solution Tank by Californium Source-Driven Noise Analysis

Subcritical californium source-driven noise analysis (CSDNA) measurements were performed at the Oak Ridge Critical Experiments Facility in 1983 using a stainless-steel tank with an inside diameter of 76.2 cm and a height of 91.4 cm but only filled with a uranyl (93.16 wt.% 235 U) nitrate solution to a height of 76.2 cm for all measurements. The free acid content of the uranyl nitrate solution was less than 0.01 N to minimize hazards in handling. The total available highly enriched uranium for these measurements was 5,296 g. The concentration of the solution was varied from the highest density of 14.71 grams of uranium per liter (g U/L) initially in 16 steps, lowering the concentration to 0.3492 g U/L, and finally using a tank filled with only water. The tank had a Plexiglas lid to minimize evaporation. The Cf source was contained in a re-entrant Lexan tube which could be in the solution parallel to the axis of the cylindrical tank. The detectors were 3 He proportional counters in the solution in shrink-fit tubing to isolate the counters from the fissile solution and adjacent to the outside of the tank. In some cases, the detectors were scintillators adjacent to the outside of the tank. In other cases, the source was external to the tank. Some data presented in this report are from notes and are not in the logbook. The prompt neutron decay constant was obtained from fitting the date from the CSDNA measurements. The purpose of this report is to document the experimental information for the measurements performed so that later, researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (ICSBEP) or a Nuclear Energy Agency benchmark. The prompt neutron decay measurements could be the basis of as International Reactor Physic Benchmark Program. The data from these measurements are available from the Records Management Services Department of Oak Ridge National Laboratory, and the logbook is also available from the ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Measurement of the 240 Pu(n,f) Prompt Fission Neutron Spectra with Chi-Nu

The DOE Nuclear Criticality Safety Program has funded a multi-year effort to measure the 240 Pu(n,f) Prompt Fission Neutron Spectrum at Chi-Nu. This project is a joint LANL-LLNL effort, involving the preparation of 12 240 Pu foils and construction of a Parallel-Plate Avalanche Counter at LLNL, with subsequent measurements of the 240 Pu(n,f) PFNS at the Chi-Nu beamline at the Los Alamos Neutron Science Center’s Weapons Neutron Research facility (LANSCE/WNR). We expect the PPAC to be ready in time to perform the measurements this run cycle.

240Pu Foils↗

R -Matrix Analysis and Statistical Properties of Dysprosium Isotopes in the Neutron Energy Ranges Up To A Few Kev

In support of the Nuclear Criticality Safety Program, a set of evaluated resonance parameters was generated for seven dysprosium isotopes in the neutron energy range from thermal up to a few keV. The evaluation methodology used the Reich-Moore approximation to fit, with the R-matrix code SAMMY, the high-resolution capture and transmission measurements on natural and enriched samples recently performed at the Rensselaer Polytechnic Institute Gaerttner LINear ACcelerator facility. Additional transmission data measured on enriched samples by Liou at the Columbia University Nevis synchrocyclotron in the mid-seventies were used to gauge the neutron widths above 15 eV. Thermal constants such as absorption and (in)coherent scattering cross sections and corresponding scattering lengths were calibrated to the National Institute of Standards and Technology’s compilation except for 161,164 Dy isotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Procedure for Creating, Reviewing, and Submitting Input Files into the Benchmark Library

Los Alamos National Laboratory (LANL) has a number of criticality benchmark input files, modeled for use with MCNP, developed and maintained by various organizations including the Nuclear Criticality Safety (NCS) Division, XCP-3, and XCP-5. The purpose of this procedure is to standardize input file creation, review, and maintenance. This procedure incorporates existing practices used by IRSN as documented in the original report and the translation from French in addition to practices used by the LANL NCS Division as documented in. The report relates to input files used for the validation of the continuous energy Monte Carlo code MCNP6 but is general enough to be extended to other codes. This report describes the procedure on how to prepare and use benchmarks (taken mainly from the ICSBEP Handbook) for the validation of calculation routes. In particular, this report describes the procedure to follow in the creation of the input files and their integration in the experimental validation databases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

140,142 Ce Neutron Cross Section Resolved Resonance Region Evaluation [Abstract]

A resolved resonance region evaluation of 140,142 Ce has been carried out by Oak Ridge National Laboratory. Requested by the US Nuclear Criticality Safety Program, this evaluation is based on recent high-resolution transmission and capture high-resolution measurements of nat Ce and 142 Ce conducted at JRC-GEEL at the Geel Linear Accelerator facility, as well as recently measured thermal constants available from the EXFOR database. Starting from the resonance parameters from the ENDF/B-VIII.0 library and following a preliminary R-matrix analysis, an updated set of resonance parameters and corresponding covariance information was derived by the fit of these experimental datasets using the Reich-Moore approximation of the R-matrix theory as implemented in the SAMMY code system. The resolved resonance region upper energy limit for 140 Ce was kept at 200 keV while the 142 Ce resonance region was extended from 13 to 26 keV. This new evaluation was found to be in good agreement not only with several integral quantities of interest to the reactor physics community, but also with the stellar Maxwellian-averaged cross section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of ( n, γ ) cross section of 90 Zr [Abstract]

The isotopes of Zr with A = [90, 91, 92, 94] make up more than 97% of naturally occurring Zr and are important to many nuclear applications such as nuclear reactors. One of the attractive qualities of naturally occurring Zr isotopes is that they have a low σγ/σt ratio at most neutron energies, such that they improve the neutron economy in reactors by preferentially scattering neutrons rather than absorbing them. This same quality also presents a challenge to measuring the capture cross section, σγ, of Zr isotopes. The ENDF/B-VIII.0 library has a relative uncertainty of approximately 10-20% for incident neutron energies < 0.1 MeV, and uncertainty greater than 20% for energies > 0.1 MeV for the majority of natural Zr isotopes. This motivated the Nuclear Criticality Safety Program (NCSP) to embark on a campaign to accurately measure and evaluate these isotopes of Zr. Here we will show energy-dependent neutron capture cross section measurements for the first enriched sample to be measured: 90 Zr. The measurements of isotopically enriched samples are being carried out at the Geel Electron Linear Accelerator (GELINA) facility of the Joint Research Center - Geel (JRC-Geel) of the European Union. As isotopic enrichment is a costly process we are careful not to activate any of the samples, as this may hinder future radiation-sensitive measurements. The activation analysis is presented in a report by Brown et al.. Once we were satisfied that the Zr samples would not be activated by the measurements, the 90 Zr sample was fabricated at Oak Ridge National Laboratory (ORNL) and shipped to GELINA. The dimensions of the cylindrical sample are approximately 0.12 cm thick and a radius of 2.5 cm. Since 90 Zr is not chemically reactive to air, bare metallic samples were employed. The sample was measured at a flight path (FP) length of 60 m, using four C 6 D 6 detectors on FP14. The final paper will include experimental details and measured cross section data for 90 Zr compared to current evaluated nuclear data libraries.

07 ISOTOPE AND RADIATION SOURCES↗

Nuclear Safety [Vol. 35, No. 2, July-December 1994]

Nuclear Safety is a journal that covers significant issues in the field of nuclear safety. Its primary scope is safety in the design, construction, operation, and decommissioning of nuclear power reactors worldwide and the research and analysis activities that promote this goal, but it also encompasses the safety aspects of the entire nuclear fuel cycle, including fuel fabrication, spent-fuel processing and handling, and nuclear waste disposal, the handling of fissionable materials and radioisotopes, and the environmental effects of all these activities. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 179 Consideration of Postaccident Consequences in the Determination of Safety Objectives for Future Nuclear Power Plants in France, D. Queniart, A. Sugier, and J. Lochard; ACCIDENT ANALYSIS: 187 Nuclear Safety Research: The Phebus FP Severe Accident Experimental Program, P. von der Hardt, A. V. Jones, C. Lecomte, and A. Tattegrain; 205 Containment Performance Analysis of the Advanced Neutron Source Reactor at the Oak Ridge National Laboratory, S. H. Kim, R. P. Taleyarkhan, and V. Georgevich; 213 Assessment of Fission Product Deposits in the Reactor Coolant System: The DEVAP Program, G. Le Marois and M. Megnin; 222 Erratum to “A Review of the Available Information on the Triggering Stage of a Steam Explosion," Vol. 35, No. 1, CONTROL AND INSTRUMENTATION: 223 Effects of Normal Aging on Calibration and Response Time of Nuclear Plant Resistance Temperature Detectors and Pressure Sensors, H. M. Hashemian; DESIGN FEATURES: 235 Defense in Depth Against the Hydrogen Risk—A European Research Program, F. Fineschi; ENVIRONMENTAL EFFECTS: 246 Technical Note: A Preliminary Analysis of the Risks to Hong Kong Resulting from Potential Accidents of Daya Bay Nuclear Power Plant, Z. Shi and X. Wei; OPERATING EXPERIENCES: 253 Reactor Shutdown Experience, Compiled by J. W. Cletcher; SPECIAL SECTION ON TMI-2 VESSEL INVESTIGATION PROJECT: 256 Three Mile Island—New Findings 15 Years After the Accident A. M. Rubin and E. Beckjord; 269 Relocation of Molten Material to the TMI-2 Lower Head, J. R. Wolf, D. W. Akers, and L. A. Neimark; 280 Insight Into the TMI-2 Core Material Relocation Through Examination of Instrument Tube Nozzles, L. A. Neimark; 288 Physical and Radiochemical Examinations of Debris from the TMI-2 Lower Head, D. W. Akers and B. K. Schuetz; 301 Results of Metallographic Examinations and Mechanical Tests of Pressure Vessel Samples from the TMI-2 Lower Head, D. R. Diercks and G. E. Korth; 313 Margin-to-Failure Calculations for the TMI-2 Vessel, J. Rempe, L. Stickler, S. Chavez, G. Thinnes, R. Witt, and M. Corradini; U.S. NUCLEAR REGULATORY COMMISSION INFORMATION AND ANALYSES: 328 1993 Accident Sequence Precursor (ASP) Program Results, L. N. Vanden Heuvel, J. W. Cletcher, D. A. Copinger, J. W. Minarick, B. W. Dolan, and P. D. O’Reilley; RECENT DEVELOPMENTS: 339 Reports, Standards, and Safety Guides, D. S. Queener; 345 Proposed Rule Changes as of June 30, 1994; ANNOUNCEMENTS: 234 Thirty-First Annual Meeting of the National Council on Radiation Protection and Measurements; 356 1995 International Incineration Conference; 358 Fifth International Controls and Instrumentation Conference; 359 ANS International Topical Meeting on Safety of Operating Reactors; 359 Fifth International Conference on Nuclear Criticality Safety; 360 International Conference on Probabilistic Safety Assessment Methodology and Applications; 351 The Authors; 357 Reviewers of Nuclear Safety, Vol. 35.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Verifying MCNP Models of the TEX High 240 Plutonium Benchmark

Computational modeling programs are invaluable tools that allow us to understand systems, safely develop new processes, and make reliable predictions about future designs. However, the effectiveness of these codes is limited by the degree to which their parameters match the real world. In the field of nuclear engineering, cross section data is one of these vital parameters. Accurate cross section data on important fissile and fissionable isotopes promotes the design of safer and more efficient fabrication, transportation, storage, and stockpiling of nuclear fuel. Unfortunately, there are knowledge gaps in data on key isotopes. In 2011, a multinational meeting hosted by the US Department of Energy Nuclear Criticality Safety Program ranked the priority of certain cross section data needs. In response, Lawrence Livermore National Lab (LLNL) designed the Thermal and Epithermal eXperiment (TEX) series of benchmark experiments. Benchmark experiments are used to validate current cross section data. They validate data by comparing the results of an actual experiment to the predicted results from a computational model. The data a benchmark applies to depends on the isotope and energy range the experiment’s neutron multiplication factor ( k eff ) is most sensitive to. The development and testing of the TEX High 240 Plutonium Benchmark will help validate 240 Pu cross section data. The configuration and materials of this benchmark are designed to be most sensitive to 240 Pu's intermediate energy range (from 0.625 ev to 100 keV ). MCNP® models of the assembly have been developed by LLNL and the results have been written in the final design report. In order for the discrepancies between benchmark models and experiments to be attributed to cross section inaccuracies, the accuracy of the models needs to be verified. The goal of this project is to verify of the results of LLNL's modeling by creating a new set of MCNP models and comparing the results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FY22 NCSP Technical Program Review [Slides]

Document details key information about the Nuclear Criticality Safety Program (NCSP) including financial data, functions and execution of the program, and accomplishments, challenges, and initiatives, as well as projected projects/accomplishments.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Development of Shielding Benchmarks Using the Godiva IV Assembly

The Nuclear Criticality Safety Program (NCSP) is developing a shielding benchmark using the Godiva IV assembly as a source. Its present status is reviewed herein. Even eight decades into the nuclear era, substantial work remains to develop a database of shielding benchmarks to support future nuclear development. A nuclear simulation is only as good as its supporting data, inputs, and validation basis. Uncertainty in these areas is addressed using conservatism, which adds margin and, occasionally, cost. In many shielding situations, high accuracy is not necessary because additional material is not particularly expensive. After all, 1–2 cm of lead often reduces the gamma ray dose substantially. However, in certain areas, conservatism can add unnecessary cost. These areas include mobile shielding applications such as casks, ships, microreactors, and spacecraft, where weight and, thus, margin is expensive. Although these characteristics are side benefits for NCSP shielding benchmark development, the main driver is enabling more reliable placement of criticality accident alarm systems (CAASs) in nuclear material facilities, such as those dedicated to the production of advanced reactor fuels. CAAS placement relies on more than accurate data and code validation. It also relies on sufficiently accurate materials specifications, geometry specifications, and a well-defined, alarm-producing baseline accident. All these things require tacit knowledge and understanding of the problem being evaluated. Benchmarks can help ensure this understanding.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Validation of New MCNP6.3 Features for Critical and Subcritical Benchmark Simulations [Slides]

A separate MCNP6.3 V&V document reports on all the default calculations for all test suites was introduced. Here, we look at new optional features of the MCNP6.3 code. Then, Fission-matrix-based options with Convergence and population testing and Automated acceleration of the fission source and Doppler Broadening Resonance Correction and HDF5 Particle Track Output (PTRAC) and Validation benchmarks: criticality, Rossi-α, and subcritical multiplication. All the new MCNP6.3 options give statistically equivalent results and should be considered for default usage in criticality and subcritical multiplication calculation work. Discussed are two separate papers at the upcoming 2023 International Conference on Nuclear Criticality Safety (ICNC 2023) that give more details on the results presented here.

97 MATHEMATICS AND COMPUTING↗