Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

An Overview of Nasa Research on Aam Noise and A Recent Noise and Number Study

NASA conducts psychoacoustic research on the human response to Urban Air Mobility (UAM) vehicles as part of its Advanced Air Mobility (AAM) mission. This presentation provides an overview of NASA’s role in AAM research with an emphasis on recent work investigating people’s response to frequent UAM vehicle flyover sounds.

UAM↗

Noise analysis for the Sorkin and Peres tests performed on a quantum computer

We use quantum computers to test the foundations of quantum mechanics through quantum algorithms that implement some of the experimental tests as the basis of the theory's postulates. These algorithms can be used as a test of the physical theory under the premise of a perfect hardware or as a test of the hardware under the premise that quantum theory is correct. In this paper, we show how the algorithms can be used to test the efficacy of a quantum computer in obeying the postulates of quantum mechanics. We study the effect of different types of errors on the results of experimental tests of the postulates. A salient feature of this error analysis is that it is deeply rooted in the fundamentals of quantum mechanics as it highlights how systematic errors affect the quantumness of the quantum computer.

Sadana, Simanraj↗

Correlated charge noise and relaxation errors in superconducting qubits

In This report, the central challenge in building a quantum computer is error correction. Unlike classical bits, which are susceptible to only one type of error, quantum bits (“qubits”) are susceptible to two types of error, corresponding to flips of the qubit state about the X- and Z-directions. While the Heisenberg Uncertainty Principle precludes simultaneous monitoring of X- and Z-flips on a single qubit, it is possible to encode quantum information in large arrays of entangled qubits that enable accurate monitoring of all errors in the system, provided the error rate is low. Another crucial requirement is that errors cannot be correlated. Here, we characterize a superconducting multiqubit circuit and find that charge fluctuations are highly correlated on a length scale over 600 µm; moreover, discrete charge jumps are accompanied by a strong transient suppression of qubit energy relaxation time across the millimeter-scale chip. The resulting correlated errors are explained in terms of the charging event and phonon-mediated quasiparticle poisoning associated with absorption of gamma rays and cosmic-ray muons in the qubit substrate. Robust quantum error correction will require the development of mitigation strategies to protect multiqubit arrays from correlated errors due to particle impacts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Increased accuracy and signal-to-noise ratio through recent improvements in infra-red video bolometer fabrication and calibration

The infra-red video bolometer (IRVB) is a diagnostic equipped with an infra-red camera that measures the total radiated power in thousands of lines of sight within a large field of view. Recently validated in MAST-U [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)], it offers a high spatial resolution map of the radiated power in the divertor region, where large gradients are expected. The IRVB’s sensing element comprises a thin layer of high Z absorbing material, typically platinum, usually coated with carbon to reduce reflections [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)].Here, the possibility of using a relatively inert material such as titanium, is explored that can be produced in layers up to 1 μm compared to 2.5 μm for Pt and then coat it with Pt of the desired thickness (0.3 μm per side here) and carbon. This leads to a higher temperature signal (about 3 times) and better spatial resolution (about 4 times), resulting in higher accuracy in the measured power [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)]. This assembly is also expected to improve foil uniformity, as the Pt layer is obtained via deposition rather than mechanical processes [Mukai et al., Rev. Sci. Instrum. 87, 2014 (2016)].Given its multi-material composition, measuring the thermal properties of the foil assembly is vital. Various methods using a calibrated laser as a heat source have been developed, analyzing the temperature profile shape [Sano et al., Plasma and Fusion Res. 7, 2405039 (2012)] and [Mukai et al., Rev. Sci. Instrum. 89, 10E114 (2018)] or fitting the calculated laser power for different intensities and frequencies [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)]. Here, a simpler approach is presented, which relies on analyzing the separate components of the foil heat equation for a single laser exposure in a given area. This can then be iterated over the entire foil to capture local deviations.

Magnetic Fusion Energy↗