Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Neutron time-of-flight detectors (nTOF) used at Sandia’s Z-Machine

Neutron time-of-flight (nTOF) detectors have been used on Sandia National Laboratories’ Z-Machine for inertial confinement fusion and magnetized liner fusion experiments to infer physics parameters including the apparent fuel-ion temperature, neutron yield, the magnetic-radius product (BR), and the liner rho-r. Single-paddle, dual-paddle, and co-axial scintillation nTOF detectors are used in axial lines-of-sight (LOS) and LOS that are 12° from the midplane. Detector fabrication, characterization, and calibration are discussed.

Chandler, G. A. (ORCID:0000000219640927)↗

Comparing Thermal Neutron Scintillators for Use With SiPM-Readout Detectors

Scintillator-based thermal neutron detectors for scientific scattering facilities offer an effective combination of large-area coverage and good spatial resolution. At Oak Ridge National Laboratory, silicon photomultiplier (SiPM)-readout Anger cameras using 6 Li glass scintillators have been developed, but the spatial resolution of these detectors is limited by the relatively low light yield of the glass. Recently, several brighter scintillator compositions with sufficient 6 Li concentration have emerged as promising candidates for higher-resolution imaging. Here, in this work, we evaluate five scintillator materials: GS20, LiF/ZnS:Ag, LiF/ZnO:Zn, LiI:Eu, and Cs 2 LiYCl 6 :Ce, each mounted on a SiPM Anger camera. For each scintillator, the neutron detection efficiency, spatial resolution, and count rate capabilities were measured and compared. Each of the new compositions achieved a spatial resolution better than 0.5 mm, compared to 0.66 mm for GS20, with LiI:Eu reaching the best value of 0.32 mm. Although these compositions improve the spatial resolution of the Anger camera, their longer pulse decay times limit their use in high count rate applications, and the camera’s hardware must be optimized for the different properties of the new scintillators.

Neutron detectors↗

Using real-time nuclear activation detectors for measuring neutron yields from D(D, T)n reactions on the national ignition facility (NIF)

The National Ignition Facility (NIF) has 48 Real-Time Nuclear Activation Detectors distributed around the target chamber capable of measuring deuterium-triton reaction neutron yields with high precision. Here, in this work, we extend this functionality to deuterium–deuterium (DD) reaction neutrons using a nuclear reaction that occurs in the detector’s scintillator material. The corresponding decay of the activated material has a very short half-life of 5 s, which necessitates rapid data collection immediately following an experiment. In this regime, dead time can be very high (>50%) adding significant uncertainty to the measurement. To combat this, we have developed a dead time model that can self-consistently describe the measured data. Initial results show reasonable agreement (within 20%) with DD neutron yields from neutron time-of-flight spectrometers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Triple-mode detector for fast neutrons, slow neutrons, and gamma ray spectroscopy

This disclosure provides systems, methods, and apparatus related to neutron detection and gamma ray detection. In one aspect, a detector comprises a scintillator structure that comprises an organic scintillator and an inorganic scintillator. The organic scintillator is in the form of one or more elements of a specified length. The inorganic scintillator is in the form of one or more elements of the specified length. First ends of the one or more organic scintillator elements and first ends of the one or more inorganic scintillator elements define a first surface. Second ends of the one or more organic scintillator elements and second ends of the one or more inorganic scintillator elements define a second surface.

Derenzo, Stephen↗

Model Development and Analysis of a High-Fidelity Neutron Transport Sensor: The Quadrupole Detector Concept for Measurement of the Neutron Flux Gradient

Accurate reconstruction of the neutron flux distribution within a reactor core is essential for safe and efficient reactor operation. Traditional power shape synthesis in Light Water Reactors relies on hundreds of in-core detectors. However, this approach becomes impractical for Advanced Reactors and Microreactors due to limited space and harsh environments. To address this challenge, we propose a data-driven methodology that combines high-fidelity modeling with real-time ex-core sensor measurements, enabling the reconstruction of core power distribution while minimizing the reliance on intrusive in-core instrumentation. This project began in FY24 and achieved two initial milestones: (1) the definition of a three-year development plan for a Digital Twin framework and (2) the development of high-fidelity neutronics models of the Purdue University Reactor One (PUR-1) using both MCNP6 and OpenMC. The PUR-1 reactor, a zero-power facility, was selected due to its suitability for neutronics-focused modeling and the availability of experimental data for validation. Both models were benchmarked using neutron flux measurements obtained from irradiated gold foils, which were strategically placed within the core during a dedicated campaign in July 2024. This report marks the continuation and completion of those foundational tasks. The OpenMC model has been refined (improved geometric accuracy, expanded cross-section libraries, and refined sampling) and validated using additional experimental data. An updated sensor design—based on quadrupole configuration—was designed to measure both ex-core flux and its spatial gradient. These measurements will serve as inputs to a neural network-based reconstruction algorithm. Finally, the methodology was demonstrated on a two-dimensional test case representative of the heterogeneous material composition of the PUR-1 reactor core. A neural network implementation of the Kirchhoff-Helmholtz integral equation was employed to solve the boundary value problem using peripheral sensor measurements. The preliminary results confirm the strong potential of the proposed approach for accurate and minimally invasive neutron flux reconstruction.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Neutron time of flight (nToF) detectors for inertial fusion experiments

Neutrons generated in Inertial Confinement Fusion (ICF) experiments provide valuable information to interpret the conditions reached in the plasma. The neutron time-of-flight (nToF) technique is well suited for measuring the neutron energy spectrum due to the short time (100 ps) over which neutrons are typically emitted in ICF experiments. By locating detectors 10s of meters from the source, the neutron energy spectrum can be measured to high precision. Here, we present a contextual review of the current state of the art in nToF detectors at ICF facilities in the United States, outlining the physics that can be measured, the detector technologies currently deployed and analysis techniques used.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called γ-flash, and offer the highest possible detection sensitivity. In this paper, we present several steps towards such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C 6 D 6 detectors, and one LaCl 3 (Ce) detector. The performance of these detection systems is compared using 93 Nb(n, γ) data. We also developed a detailed G EANT small4 Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a γ detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigated experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of proton quenching in a plastic scintillator detector

The non-linear energy response of the plastic scintillator EJ-260 is measured with the MicroCHANDLER detector, using neutron beams of energy 5 to 27 MeV at the Triangle Universities Nuclear Laboratory. The first and second order Birks' constants are extracted from the data, and found to be $k_B = (8.70 \pm 0.93)\times 10^{-3}\ {\rm g/cm^2/MeV}$ and $k_C = (1.42 \pm 1.00) \times 10^{-5}\ {\rm (g/cm^2/MeV)^2}$. This result covers a unique energy range that is of direct relevance for fast neutron backgrounds in reactor inverse beta decay detectors. Furthermore, these measurements will improve the energy non-linearity modeling of plastic scintillator detectors. In particular, the updated energy response model will lead to an improvement of fast neutron modeling for detectors based on the CHANDLER reactor neutrino detector technology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of Synthetic Diamond Detectors for Fast Neutron and X-ray Detection [Slides]

Element6 has come out of a two year production pause (pre-COVID) with material that lacks their previous QC – some is excellent, but screening is needed. Applied Diamond can now make usable polycrystalline material, for applications not requiring absolute flux calibration. A large area possible (1cm 2 ). Great Lakes Crystal Technology has made great progress in two years, but still needs development to become a trusted supplier of single crystal material. LANL staff (Dongsung Kim) has developed proficient lithography and bonding expertise at CINT to make devices from vendor supplied material. LANL staff has continued and expanded capabilities for device testing at NSLS-II.

42 ENGINEERING↗