Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Yield”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Simultaneous measurement of organic scintillator response to carbon and proton recoils

Organic scintillators are widely used for neutron detection in both basic nuclear physics and applications. While the proton light yield of organic scintillators has been extensively studied, measurements of the light yield from neutron interactions with carbon nuclei are scarce. Demonstrate a new approach for the simultaneous measurement of the proton and carbon light yield of organic scintillators. Provide new carbon light yield data for the EJ-309 liquid and EJ-204 plastic organic scintillators. A 33-MeV 2 H + beam from the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory was impinged upon a 3-mm-thick Be target to produce a high-flux, broad-spectrum neutron beam. The double time-of-flight technique was extended to simultaneously measure the proton and carbon light yields of the organic scintillators, wherein the light output associated with the recoil particle was determined using np and nC elastic scattering kinematics. The proton and carbon light yield relations of the EJ-309 liquid and EJ-204 plastic organic scintillators were measured over a recoil energy range of approximately 0.3 to 1 MeV and 2 to 5 MeV, respectively, for EJ-309, and 0.2 to 0.5 MeV and 1 to 4 MeV, respectively, for EJ-204. Furthermore, these data provide new insight into the ionization quenching effect in organic scintillators and key input for simulation of the response of organic scintillators for both basic science and a broad range of applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Free spectator nucleons in ultracentral relativistic heavy-ion collisions as a probe of neutron skin

Besides the yield ratio of free spectator neutrons produced in ultracentral 96 Zr + 96 Zr to 96 Ru + 96 Ru collisions, we propose that the yield ratio N n /N p of free spectator neutrons to protons in a single collision system at the BNL Relativistic Heavy Ion Collider or the CERN Large Hadron Collider can be a more sensitive probe of the neutron-skin thickness Δrnp and the slope parameter L of the symmetry energy. Here, the idea is demonstrated based on the proton and neutron density distributions of colliding nuclei obtained from Skyrme-Hartree-Fock-Bogolyubov calculations, and on a Glauber model that provides information of spectator matter. The final spectator particles are produced from direct emission, clusterization by a minimum spanning tree algorithm or a Wigner function approach, and deexcitation of heavy clusters by gemini. A larger Δr np associated with a larger L value increases the isospin asymmetry of spectator matter and thus leads to a larger N n /N p , especially in ultracentral collisions where the multiplicity of free nucleons are free from the uncertainties of cluster formation and deexcitation. We have further shown that the double ratio of N n /N p in isobaric collision systems or in collisions by isotopes helps to cancel the detecting efficiency for protons. Effects from nuclear deformation and electromagnetic excitation are studied, and they are found to be subdominant compared to the expected sensitivity to Δr np .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Probing neutron-skin thickness with free spectator neutrons in ultracentral high-energy isobaric collisions

We show that the yield ratio of free spectator neutrons produced in high-energy 96 Zr+ 96 Zr to 96 Ru+ 96 Ru collisions is a clean probe of the neutron-skin thickness of colliding nuclei and the slope parameter L of the symmetry energy. The idea is demonstrated based on the proton and neutron density distributions via a state-of-the-art Skyrme-Hartree-Fock-Bogolyubov calculation. Among spectator nucleons given by the Glauber model, free spectator neutrons include those from direct production that survive from clusterization as well as those from deexcitation of heavy clusters described by the popular GEMINI model. More free neutrons are produced in collisions of 96 Zr nucleus due to its larger neutron skin, compared to those produced in collisions of 96 Ru nucleus with a smaller neutron skin. The difference of the free spectator neutron yield is further increased with the increasing difference of the neutron-skin thickness between 96 Zr and 96 Ru with a larger L value, and the increase in ultracentral collisions is particularly insensitive to model details and experimental uncertainties. Since the production of free spectator neutrons is not affected by the complicated dynamics in the mid-rapidity region, the ratio of their multiplicities in ultracentral isobaric collisions is a robust observable for constraining the neutron skin and L value.

79 ASTRONOMY AND ASTROPHYSICS↗

T-2 Actinide Evaluation Efforts [Slides]

Major evaluation efforts have been completed or are underway for actinide fission observables, including fission product yields, PFNS, neutron multiplicity, and neutron-induced cross sections. Energy-dependence and covariances for fission product yields are being developed due to new measurements and modeling efforts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Total kinetic energy and mass yields from the fast neutron-induced fission of $^{239}\hbox {Pu}$

The total kinetic energy (TKE) release in fission is an important observable, constituting over 80% of the energy released in fission (E f ≈ 200MeV). While the TKE release in the 239 Pu(n,f) reaction was previously measured up to 50 MeV incident neutron energy (E n ), there were features in TKE release at the highest values of E n that were puzzling. There was a marked flattening of TKE release from E n = 30 to 50 MeV, in disagreement with the clearly decreasing TKE observed from E n = 0.5 to 30 MeV. To verify and clarify this trend, TKE measurements at higher values of E n were made. We present absolute measurements of TKE release in 239 Pu(n,f) from E n = 2.4 to 100 MeV. Here, we used silicon PIN detectors to measure the fragment energies and deduce mass-yield curves using the 2E-method. We also discuss fission asymmetry and the relationships between approx. fission fragment mass and distortion.

239Pu↗

Overview of Nuclear Data Measurement and Analysis at RP [Slides]

This presentation details neutron capture in 54 Fe along with neutron capture yield and γ-ray cascade spectra measurements. The presentation then follows with thermal neutron die-away measurements and concludes with URR improvement to SAMMY.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Release of Evaluated 235 U(n,f) Average Prompt Fission Neutron Multiplicities Including the CGMF Model

This report documents an evaluation of the average prompt fission neutron multiplicity, $\overline{v}_p$, of 235 U from 200 keV to 15 MeV that is a potential release candidate for the upcoming U.S. nuclear data library, ENDF/B-VIII.1. This evaluation had to be re-done from "scratch", as the input to the $\overline{v}_p$ evaluation of the previous library, ENDF/B-VIII.0, was lost. That means that all available experimental data were re-analyzed and uncertainties were re-estimated. Another major difference to ENDF/B-VIII.0 is that this evaluation includes model information from the Hauser-Feshbach fission fragment decay code CGMF, while ENDF/B-VIII.0 is based purely on experimental data. CGMF links several fission quantities with each other; $\overline{v}_p$ is predicted by assumptions made on, e.g., pre-neutron emission yields as a function of mass, the total kinetic energy, or spin and parity of fission fragments. This allows to perform two types of validation for the new 235 U $\overline{v}_p$: On the one hand, one can employ evaluated CGMF parameters obtained from fitting to experimental 235 U $\overline{v}_p$ to predict yields as a function of mass, the average total kinetic energy, or the mean energy of the prompt fission neutron spectrum. These model-predicted values can then be compared to experimental and evaluated data. The model-predicted fission-observable values using evaluated parameters obtained here are reasonably close to experimental data indicating the evaluated 235 U(n,f) $\overline{v}_p$ are physical. On the other hand, one can validate 235 U $\overline{v}_p$ with respect to integral responses such as fast ICSBEP critical assemblies or LLNL pulsed spheres. LLNL pulsed-sphere neutron-leakage spectra are minimally impacted by the new 235 U $\overline{v}_p$ as these experimental data are shape data and the $\overline{v}_p$ would mostly lead to a change in normalization of the data as the spheres are relatively thin (0.7 and 1.5 mean-free path) and, thus, mostly depend on 235 U $\overline{v}_p$ from 12-15 MeV. The change in the predicted effective neutron multiplication factor, k eff , of selected ICSBEP critical assemblies, however, is large compared to values using ENDF/B-VIII.0 and experimental k eff : The average bias is 108 pcm across all studied k eff values versus 12 pcm for ENDF/B-VIII.0. A reasonable performance in simulating keff (mean bias of 14 pcm) can be retained by tweaking 235 U $\overline{v}_p$ from 3-5 MeV, and combining it with a recent 235 U PFNS evaluation that is also a ENDF/B-VIII.1 release candidate.

235U↗

Evaluated 238 U(n,f) Average Prompt Fission Neutron Multiplicities Including the CGMF Model

This report documents an evaluation of the average prompt fission neutron multiplicity, $\overline{v}_p$, of 238 U from 800 keV to MeV. This evaluation had to be re-done from “scratch” as the input to previous $\overline{v}_p$ evaluations, specifically ENDF/B-VIII.0, was not found. That means that all available experimental data were re-analyzed and uncertainties were re-estimated. The new evaluated 238 U $\overline{v}_p$ based on only experimental data differs distinctly from ENDF/B-VIII.0 $\overline{v}_p$ from 2 to 4.5 MeV, and from 6 to 7 MeV, and is otherwise similar. The difference from 2 to 4.5 MeV stems from the fact that ENDF/B-VIII.0 was tweaked in this energy range to data of Frehaut, while two other, equally trustworthy, data sets would indicate an evaluated 238 U $\overline{v}_p$ that is up to 2% higher. Also, second chance fission in ENDF/B-VIII.0 was smoothed over from 6–7 MeV. Another major difference to ENDF/B-VIII.0 is that one of the evaluations presented here includes model information from the Hauser-Feshbach fission fragment decay code CGMF, while ENDF/B-VIII.0 is based purely on experimental data. CGMF links several fission quantities with each other; $\overline{v}_p$ is predicted by assumptions made on, e.g., pre-neutron emission yields as a function of mass, the total kinetic energy, or spin and parity of fission fragments. This allows to validate the new 238 U $\overline{v}_p$ by using CGMF parameters obtained from fitting to experimental 238 U $\overline{v}_p$ to predict yields as a function of mass, the average total kinetic energy, or the mean energy of the prompt fission neutron spectrum. These model-predicted values can then be compared to experimental and evaluated data. The model-predicted fission-observable values using evaluated parameters obtained here are reasonably close to experimental data for some observables, but are farther away from experimental data related to TKE observables. In addition to that, the evaluated 238 U(n,f) $\overline{v}_p$ shows similar deviations from ENDF/B-VIII.0 as for the evaluation with only experimental data. This difference is expected to lead to changes in simulated effective neutron multiplication factor, $k_{eff}$ of ICSBEP critical assemblies that are sensitive to 238 U in the fast range (BigTen, Flattop, Flattop-Pu). These changes in $k_{eff}$ need to be counter-balanced. Chi-Nu PFNS experimental data are expected to be released in the next few months that might lead to the needed changes in the PFNS. Until then, we hold off in benchmarking the new 238 U(n,f) $\overline{v}_p$ as well as submitting it to ENDF/B-VIII.1. Also, new high-precision 238 U $\overline{v}_p$ are expected to be measured by the CEA in the next two years that will shed further light on question on 238 U $\overline{v}_p$ from 2–4.5 and 6–7 MeV.

238U↗

Measurements of gamma-ray production cross sections for shielding materials of space nuclear systems

Measurements of secondary gamma ray production from neutron interactions have been made over the entire energy range of interest in shielding applications. The epithermal capture gamma ray yields for both resolved gamma ray lines and continuum have been measured from thermal energies to 100 KeV for natural tungsten and U-238, two important candidate shield materials in SNAP reactor systems. Data are presented to illustrate the variation of epithermal capture gamma ray yields with neutron energy. The gamma ray production cross sections from (n,xy) reactions have been measured for Fe and Al from the threshold energies for inelastic scattering to approximately 16 MeV. Typical Fe and Al cross sections obtained with high-neutron energy resolution and averaged over broad neutron-energy groups are presented.

Orphan, V. J.↗

First Experiments and Radiographs on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) Dense Plasma Focus

We report a dense plasma focus (DPF) is a relatively compact coaxial plasma gun, which completes its discharge as a Z-pinch. These devices are designed to operate at a variety of scales to produce short (<100 ns) pulses of ions, X-rays, and/or neutrons. LLNL recently constructed and brought into operation a new device, the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF, which is designed for radiography and high-yield operations. This device has been commissioned and has achieved neutron yields of up to 3.8E11 neutrons/pulse at 2.5-MA peak current while operating at up to 1 MJ of stored energy in its original pulsed power configuration. MJOLNIR is equipped with a wide range of diagnostics, including nuclear activation detectors, neutron time-of-flight (nToF) detectors, a fast-framing camera, optical light gates, and a time-gated neutron and X-ray imager. LLNL also runs unique particle-in-cell (PIC) simulations of DPF discharges in the Chicago code and has gained significant insight into the various physical factors that influence neutron yield. MJOLNIR is one of the first DPFs whose design and continual upgrades are heavily influenced by model predictions. In this article, we describe insights from modeling, device operation, and recent results. Comparisons between modeling predictions and measurements, as well as X-ray and neutron images are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance evaluation of neutron noise analysis in detecting special nuclear materials

Reliable and rapid inspection techniques play a vital role in preventing illicit trafficking of special nuclear materials. Active interrogation systems using neutrons produced by portable, high-flux deuterium-deuterium or deuterium-tritium neutron generators are being actively developed as a secondary scanning tool for this purpose. In this study, a neutron noise analysis-based approach for detecting unshielded and shielded special nuclear materials by using a pulsed deuterium-tritium neutron generator was evaluated. Here, this approach analyzes the fluctuation of neutron counts. Its performance was quantified with regard to time-to-detection to achieve a minimum probability of detection of 99% and a probability of false alarm of less than 1% considering various amounts of special nuclear materials and different shielding configurations. It was demonstrated that this approach could detect 17 uranium slugs in 5 s given a neutron generator yield of 8.1 × 10 7 n/s. These slugs could be detected within a reasonable time frame (200 s) when they were shielded by 10.16 cm of high-density polyethylene. The results obtained using the neutron noise analysis approach were compared with those obtained using the commonly used differential die-away analysis technique, a sensitive technique for detecting the presence of fissile materials by utilizing the prompt fission neutrons produced when the source neutrons from a neutron generator are completely diminished. For example, the time to detect 2 unshielded uranium slugs was 2.1 s when using the differential die-away analysis technique; it increased to 93 s for the neutron noise analysis approach. Although the noise analysis-based approach exhibits an overall performance which is not as good as that of differential die-away, neutron noise provides an alternative method for effective detection of special nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron star models

The current state of neutron star structure calculations is reviewed. Uncertainties in the equation of state for matter at and above nuclear density remain. The role of the delta resonance, pion condensates, and quark matter is reviewed. It is found that recent models yield stable neutron star masses which are consistent with observational estimates.

Canuto, V.↗

Inertial Confinement Fusion—Experimental Physics: Laser Drive

Laser-driven inertial confinement fusion creates a central hot-spot plasma by irradiating a spherical target containing a thermonuclear fuel layer of deuterium (D) and tritium (T) with temporally-shaped, high-intensity lasers or X rays. Inertial confinement fusion relies on the DT-fusion alpha particles depositing their energy in a hot-spot plasma, causing its temperature to rise sharply and a thermonuclear burn wave to propagate out through the surrounding cold, dense DT fuel, producing significantly more energy than was used to heat and compress the fuel. Alpha heating has been demonstrated and burning plasma (i.e., yield amplification due to alpha heating >3.5) is being explored with megajoule-scale lasers on the path to ignition (i.e., yield amplification due to alpha heating >20)

alpha particles↗

Radiation experiments on Cosmos 2044: K-7-41, parts A, B, C, D, E

The Cosmos 2044 biosatellite mission offered the opportunity for radiation measurements under conditions which are seldom available (an inclination of 82.3 deg and attitude of 294 x 216 km). Measurements were made on the outside of the spacecraft under near-zero shielding conditions. Also, this mission was the first in which active temperature recorders (the ATR-4) were flown to record the temperature profiles of detector stacks. Measurements made on this mission provide a comparison and test for modeling of depth doses and LET spectra for orbital parameters previously unavailable. Tissue absorbed doses from 3480 rad (252 rad/d) down to 0.115 rad (8.33 mrad/d) were measured at different depths (0.0146 and 3.20 g/sq cm, respectively) with averaged TLD readings. The LET spectra yielded maximum and minimum values of integral flux of 27.3 x 10(exp -4) and 3.05 x 10(exp -4)/sq cm/s/sr, of dose rate of 7.01 and 1.20 mrad/d, and of dose equivalent rate of 53.8 and 11.6 mrem/d, for LET(sub infinity)-H2O is greater than or equal to 4 keV/micron. Neutron measurements yielded 0.018 mrem/d in the thermal region, 0.25 mrem/d in the resonance region and 3.3 mrem/d in the high energy region. The TLD depth dose and LET spectra were compared with calculations from the modeling codes. The agreement is good but some further refinements are in order. In comparing measurements on Cosmos 2044 with those from previous Cosmos missions (orbital inclinations of 62.8 deg) there is a greater spread (maximum to minimum) in depth doses and an increased contribution from GCRs, and higher LET particles, in the heavy particle fluxes.

Frank, A. L.↗

Experiment K-7-41: Radiation Experiments on Cosmos 2044

The Cosmos 2044 biosatellite mission offered the opportunity for radiation measurements under conditions which are seldom available (an inclination of 82.3 degrees and altitude of 294 x 216 km). Measurements were made on the outside of the spacecraft under near-zero shielding conditions. Also, this mission was the first in which active temperature recorders (the ATR-4) were flown to record the temperature profiles of detector stacks. Measurements made on this mission provide a comparison and test for modeling of depth doses and LET spectra for orbital parameters previously unavailable. Tissue absorbed doses from 3480 rad (252 rad/d) down to 0.115 rad (8.33 mrad/d) were measured at different depths (0.0146 and 3.20 g/sq. cm, respectively) with averaged TLD readings. The LET spectra yielded maximum and minimum values of integral flux of 27.3 x 10-4 and 3.05 x 10(exp -4) cm(exp -2).s(exp -1).sr(exp -4) of dose rate of 7.01 and 1.20 mrad/d, and of dose equivalent rate of 53.8 and 11.6 mrem/d, for LET(infinity).H2O is greater than or equal to 4 keV/micro-m. Neutron measurements yielded 0.018 mremld in the thermal region, 0.25 mrem/d in the resonance region and 3.3 mrem/d in the high energy region. The TLD depth dose and LET spectra have been compared with calculations from the modeling codes. The agreement is good but some further refinements are in order. In comparing measurements on Cosmos 2044 with those from previous Cosmos missions (orbital inclinations of 62.8 degrees) there is a greater spread (maximum to minimum) in depth doses and an increased contribution from GCR's, and higher LET particles, in the heavy particle fluxes.

Benton, E. V.↗

Revision of Fission Yields Uncertainties in ENDF/B-VIII.0

The spontaneous and neutron-induced fission yield sublibraries in the Evaluated Nuclear Data Files (ENDF/B) contain cumulative and independent fission yield values for dozens of fissioning systems, and hundreds of fission products. In this work, we report on a correction step that was undertaken after observing anomalously large uncertainties for several end-of-chain fission products. A total of 17 cumulative fission yield uncertainties and the value of 2 independent yields were corrected as a result of this revision.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗