Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Multiplicity Counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Correlated Signal Analysis for Nuclear Emergency Response

In the context of nuclear emergency response (NER) scenarios, the critical task is to quickly identify a "black box" as a potential threat, as failing to do so could have catastrophic consequences. Techniques for passive assay of a “black box” typically include gamma-ray spectroscopy and neutron coincidence/multiplicity counting. However, there are significant challenges associated with these type of measurements. First, the presence of intervening materials can obstruct the detection of relevant signatures. Second, the presence of strong non-fission neutron sources, like (α, n) emitters, can add uncertainties to the neutron multiplicity analysis. In our LDRD-MFR Phase II work, a portable neutron spectrometer, called the Compact Fast Neutron Spectrometer (CFNS), was developed for NER applications. The CFNS system leverages information-rich neutron energy spectra to derive actionable information. This work investigates the use of correlated signals in the CFNS from special nuclear material (SNM) to characterize physical properties, such as intervening shielding material and fission to non-fission neutron contributions. In this report, the Phase II results from bulk SNM measurements at the National Criticality Experiments Research Center (NCERC) are briefly discussed along with the motivation for this work. Afterwards, simulations using the MCNPX-PoliMi transport code are discussed, which were used to expand our correlated signal study. Signal triggered analysis for neutron multiplicity extraction will also be discussed. Lastly, the use neutron-photon correlations for intervening material identification are shown, along with the use of correlated neutron energy spectra for α-ratio extraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NEUTRON STAR MASS–RADIUS CONSTRAINTS USING EVOLUTIONARY OPTIMIZATION

The equation of state of cold supra-nuclear-density matter, such as in neutron stars, is an open question in astrophysics. A promising method for constraining the neutron star equation of state is modeling pulse profiles of thermonuclear X-ray burst oscillations from hot spots on accreting neutron stars. The pulse profiles, constructed using spherical and oblate neutron star models, are comparable to what would be observed by a next-generation X-ray timing instrument like ASTROSAT , NICER , or a mission similar to LOFT . In this paper, we showcase the use of an evolutionary optimization algorithm to fit pulse profiles to determine the best-fit masses and radii. By fitting synthetic data, we assess how well the optimization algorithm can recover the input parameters. Multiple Poisson realizations of the synthetic pulse profiles, constructed with 1.6 million counts and no background, were fitted with the Ferret algorithm to analyze both statistical and degeneracy-related uncertainty and to explore how the goodness of fit depends on the input parameters. For the regions of parameter space sampled by our tests, the best-determined parameter is the projected velocity of the spot along the observer’s line of sight, with an accuracy of ≤3% compared to the true value and with ≤5% statistical uncertainty. The next best determined are the mass and radius; for a neutron star with a spin frequency of 600 Hz, the best-fit mass and radius are accurate to ≤5%, with respective uncertainties of ≤7% and ≤10%. The accuracy and precision depend on the observer inclination and spot colatitude, with values of ∼1% achievable in mass and radius if both the inclination and colatitude are ≳60°.

79 ASTRONOMY AND ASTROPHYSICS↗

An improved characterization method for international accountancy measurements of fresh and irradiated mixed oxide (MOX) fuel: helping achieve continual monitoring and safeguards through the fuel cycle

Nuclear fuel accountancy measurements are conducted at several points through the nuclear fuel cycle to ensure continuity of knowledge (CofK) of special nuclear material (SNM). Non-destructive assay (NDA) measurements are performed on fresh fuel (prior to irradiation in a reactor) and spent nuclear fuel (SNF) post-irradiation. We have developed a fuel assembly characterization system, based on the novel concept of 'neutron fingerprinting' with multiplicity signatures to ensure detailed CofK of nuclear fuel through the entire fuel cycle. The neutron fingerprint in this case is determined by the measurement of the various correlated neutron signatures, specific to fuel isotopic composition, and therefore offers greater sensitivity to variations in fissile content among fuel assemblies than other techniques such as gross neutron counting. This neutron fingerprint could be measured at the point of fuel dispatch (e.g. from a fuel fabrication plant prior to irradiation, or from a reactor site post-irradiation), monitored during transportation of the fuel assembly, and measured at a subsequent receiving site (e.g. at the reactor site prior to irradiation, or reprocessing facility post-irradiation); this would confirm that no unexpected changes to the fuel composition or amount have taken place during transportation and/ or reactor operations. Changes may indicate an attempt to divert material for example. Here, we present the current state of the practice of fuel measurements for both fresh mixed oxide (MOX) fuel and SNF (both MOX and uranium dioxide). This is presented in the framework of international safeguards perspectives from the US and UK. We also postulate as to how the neutron fingerprinting concept could lead to improved fuel characterization (both fresh MOX and SNF) resulting in: (a) assured CofK of fuel across the nuclear fuel cycle, (b) improved detection of SNM diversion, and (c) greater confidence in safeguards of SNF transportation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An improved characterization method for international accountancy measurements of fresh and irradiated mixed oxide (MOX) fuel: helping achieve continual monitoring and safeguards through the fuel cycle

Nuclear fuel accountancy measurements are conducted at several points through the nuclear fuel cycle to ensure continuity of knowledge (CofK) of special nuclear material (SNM). Non-destructive assay (NDA) measurements are performed on fresh fuel (prior to irradiation in a reactor) and spent nuclear fuel (SNF) post-irradiation. We have developed a fuel assembly characterization system, based on the novel concept of 'neutron fingerprinting' with multiplicity signatures to ensure detailed CofK of nuclear fuel through the entire fuel cycle. The neutron fingerprint in this case is determined by the measurement of the various correlated neutron signatures, specific to fuel isotopic composition, and therefore offers greater sensitivity to variations in fissile content among fuel assemblies than other techniques such as gross neutron counting. This neutron fingerprint could be measured at the point of fuel dispatch (e.g. from a fuel fabrication plant prior to irradiation, or from a reactor site post-irradiation), monitored during transportation of the fuel assembly, and measured at a subsequent receiving site (e.g. at the reactor site prior to irradiation, or reprocessing facility post-irradiation); this would confirm that no unexpected changes to the fuel composition or amount have taken place during transportation and/or reactor operations. Changes may indicate an attempt to divert material for example. Here, we present the current state of the practice of fuel measurements for both fresh mixed oxide (MOX) fuel and SNF (both MOX and uranium dioxide). This is presented in the framework of international safeguards perspectives from the US and UK. We also postulate as to how the neutron fingerprinting concept could lead to improved fuel characterization (both fresh MOX and SNF) resulting in: (a) assured CofK of fuel across the nuclear fuel cycle, (b) improved detection of SNM diversion, and (c) greater confidence in safeguards of SNF transportation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Addressing Different Active Neutron Interrogation Signatures from Fissionable Material

In a continuing effort to examine portable methods for implementing active neutron interrogation for detecting shielded fissionable material research is underway to investigate the utility of analyzing multiple time-correlated signatures. Time correlation refers here to the existence of unique characteristics of the fission interrogation signature related to the start and end of an irradiation, as well as signatures present in between individual pulses of an irradiating source. Traditional measurement approaches in this area have typically worked to detect die-away neutrons after the end of each pulse, neutrons in between pulses related to the decay of neutron emitting fission products, or neutrons or gamma rays related to the decay of neutron emitting fission products after the end of an irradiation exposure. In this paper we discus the potential weaknesses of assessing only one signature versus multiple signatures and make the assertion that multiple complimentary and orthogonal measurements should be used to bolster the performance of active interrogation systems, helping to minimize susceptibility to the weaknesses of individual signatures on their own. Recognizing that the problem of detection is a problem of low count rates, we are exploring methods to integrate commonly used signatures with rarely used signatures to improve detection capabilities for these measurements. In this paper we will discuss initial activity in this area with this approach together with observations of some of the strengths and weaknesses of using these different signatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reducing uncertainties for short lived cumulative fission product yields

Uncertainties associated with short lived (halflives less than 1 day) fission product yields listed in databases such as the National Nuclear Data Center’s ENDF/B-VII are large enough for certain isotopes to provide an opportunity for new precision measurements to offer significant uncertainty reductions. A series of experiments has begun where small samples of 235 U are irradiated with a pulsed, fission neutron spectrum at the Nevada National Security Site and placed between two broad-energy germanium detectors. The amount of various isotopes present immediately following the irradiation can be determined given the total counts and the calibrated properties of the detector system. The uncertainty on the fission yields for multiple isotopes has been reduced by nearly an order of magnitude.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast-Neutron Multiplicity Counter for the Detection of Diversion Scenarios

We demonstrated the application of a fast-neutron multiplicity counter (FNMC) to detect small variations in an assembly of uranium-oxide pins. The current version of the FNMC includes eight liquid organic scintillators (EJ-309 7.62 cm diameter x 7.62 cm) and eight crystal organic scintillators (stilbene 5.08 cm diameter x 5.08 cm) in a checkerboard assembly. We measured time-correlated fast neutrons, emitted by an assembly of 32 uranium-oxide pins, using two AmLi sources to induce fissions in the sample. Each pin is a cylinder of approximately 1 cm diameter and 10 cm length, with a mass of 75.52 g and 16.37 wt% enrichment. We removed up to 16 pins from a sample consisting of 32 pins, and determined the minimum number of pins that resulted in a statistically significant decrease of neutron coincidence counts. All the measurements were performed at the Zero Power Physics Reactor facility of Idaho National Laboratory. We found that a diversion of the four innermost pins could be detected by the system in 5 minutes. The detection of time-correlated neutrons requires their discrimination from gamma-ray events. This is an especially challenging task when measuring uranium isotopes, because of the intense gamma-ray flux generated by the radioactive decay of uranium daughters. We will describe the on-board pulse shape discrimination and post processing techniques that we applied to effectively distinguish neutrons from gamma-rays. Fast-neutron measurements have several potential advantages compared to thermal and epithermal neutron counters, the most important being a shorter die-away time and therefore reduced spurious coincidences due to accidental counts. This advantage may result in a higher sensitivity in timely detecting diversion of nuclear material from peaceful uses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Portable multiplicity counter

A portable multiplicity counter has signal input circuitry, processing circuitry and a user/computer interface disposed in a housing. The processing circuitry, which can comprise a microcontroller integrated circuit operably coupled to shift register circuitry implemented in a field programmable gate array, is configured to be operable via the user/computer interface to count input signal pluses receivable at said signal input circuitry and record time correlations thereof in a total counting mode, coincidence counting mode and/or a multiplicity counting mode. The user/computer interface can be for example an LCD display/keypad and/or a USB interface. The counter can include a battery pack for powering the counter and low/high voltage power supplies for biasing external detectors so that the counter can be configured as a hand-held device for counting neutron events.

47 OTHER INSTRUMENTATION↗

Expanding Lorentz and spectrum corrections to large volumes of reciprocal space for single-crystal time-of-flight neutron diffraction

Evidence is mounting that potentially exploitable properties of technologically and chemically interesting crystalline materials are often attributable to local structure effects, which can be observed as modulated diffuse scattering (mDS) next to Bragg diffraction (BD). BD forms a regular sparse grid of intense discrete points in reciprocal space. Traditionally, the intensity of each Bragg peak is extracted by integration of each individual reflection first, followed by application of the required corrections. In contrast, mDS is weak and covers expansive volumes of reciprocal space close to, or between, Bragg reflections. For a representative measurement of the diffuse scattering, multiple sample orientations are generally required, where many points in reciprocal space are measured multiple times and the resulting data are combined. The common post-integration data reduction method is not optimal with regard to counting statistics. A general and inclusive data processing method is needed. In this contribution, a comprehensive data analysis approach is introduced to correct and merge the full volume of scattering data in a single step, while correctly accounting for the statistical weight of the individual measurements. Development of this new approach required the exploration of a data treatment and correction protocol that includes the entire collected reciprocal space volume, using neutron time-of-flight or wavelength-resolved data collected at TOPAZ at the Spallation Neutron Source at Oak Ridge National Laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-destructive assay of spent nuclear fuel using passive neutron Albedo reactivity

Passive Neutron Albedo Reactivity (PNAR) is one of fourteen techniques that has been researched and evaluated to form part of a comprehensive and integrated detection system for the non-destructive assay (NDA) of spent nuclear fuel. PNAR implemented with {sup 3}He tubes for neutron detection (PNAR-{sup 3}He) is the measurement of time correlated neutrons from a spent fuel assembly with and without a Cadmium (Cd) layer surrounding the assembly. PNAR utilizes the self-interrogation of the fuel via reflection of neutrons born in the fuel assembly back in to the fuel assembly. The neutrons originate primarily from spontaneous fission events within the fuel itself (Curium-244) but are amplified by multiplication. The presence and removal of the Cd provides two measurement conditions with different neutron energy spectra and therefore different interrogating neutron characteristics. Cd has a high cross-section of absorption for slow neutrons and therefore greatly reduces the low energy (thermal) neutron fluence rate returning. The ratios of the Singles, Doubles and Triples count rates obtained in each case are known as the Cd ratios, which are related to fissile content. A potential safeguards application for which PNAR-{sup 3}He is particularly suited is 'fingerprinting'. Fingerprinting could function as an alternative to plutonium (Pu) mass determination; providing confidence that material was not diverted during transport between sites. PNAR-{sup 3}He has six primary NDA signatures: Singles, Doubles and Triples count rates measured with two energy spectra at both shipping and receiving sites. This is to uniquely identify the fuel assembly, and confirm no changes have taken place during transport. Changes may indicate all attempt to divert material for example. Here, the physics of the PNAR-{sup 3}He concept will be explained, alongside a discussion on the development of a prototypical PNAR-{sup 3}He instrument using simulation. The capabilities and performance of the conceptual instrument will be summarized, in the context of (a) quantifying Pu mass in spent fuel assemblies and (b) detecting pin diversion (through a discrepancy between declared and measured properties of the fuel assembly) when the instrument is deployed. These quantitative capabilities are complementary to the 'fingerprinting' capability which is part of ensuring continuity of knowledge and custody of spent nuclear fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dead-Time Correction of Pulsed Neutron Source Experiments with the Backward Extrapolation Method

This paper introduces a novel procedure to correct pulsed neutron source experimental data for dead-time effects. The procedure is based on the application of the backward extrapolation method to the reaction rate value in each time interval (bin) of the neutron counts distribution as a function of time. The theoretical framework has been successfully applied to the experimental data (timestamps) from the YALINA Thermal facility driven by a pulsed D-D neutron source. Dead-time effects may have more than 500 pcm (1 pcm=1 E-5) impact on the effective multiplication factor calculated by the area method. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

The IAEA Workshop on Requirements and Potential Technologies for Replacement of 3He Detectors in IAEA Safeguards Applications

From 22 – 24 March, 2011, the International Atomic Energy Agency (IAEA) held an international workshop to address the question of a possible replacement for helium-3 based neutron detectors. Within this wider scope, the workshop was focused on those applications used in IAEA verification activities. There were two principle objectives of the workshop: 1) to determine the specific requirements that a potential replacement technology would have to satisfy, and 2) to identify alternative detector technologies that appear promising for meeting those requirements. The workshop was successful in achieving both objectives. A set of detailed and quantitative specifications was developed and achieved a general consensus among the conference participants. These included operational considerations such as temperature stability, safety, weight, and cost in addition to a number of performance requirements. The performance requirements were derived from an analysis of the spectrum of IAEA applications that use neutron detectors. After analyzing these applications, it was determined that the most common application for 3He detectors was for neutron coincidence counting, comprising over 95% of 3He use. The details and rationale for this assessment will be provided. The performance requirements for neutron coincidence counting can be directly calculated from the standard variance expressions. From these, a basic figure of merit (FOM) was developed that can be used to rank various different options. For neutron coincidence counting, the figure of merit is: , where ε is the detection efficiency and is the detector die away time. Both the FOM and the calculations will be presented. The full list of requirements is included in this paper. The second purpose of the workshop was to identify promising replacement technologies. There were multiple presentations of candidate detection technologies over the course of the workshop, covering a wide spectrum of approaches and detection physics. These technologies were judged relative to the performance of a 3He-based system, as well as its ability to meet the replacement technology requirements as developed in this workshop. The paper will present a summary of this assessment.

Pickrell, Mark↗

Thermal Neutron Die-Way-Time Studies for P and DGNAA of Radioactive Waste Drums at the MEDINA Facility

In Germany, radioactive waste with negligible heat production has to pass through a process of quality checking in order to check its conformance with national regulations prior to its transport, intermediate storage and final disposal. Additionally to its radioactive components, the waste may contain non-radioactive chemically toxic substances that can adversely affect human health and pollute the environment, especially the ground water. After an adequate decay time, the waste radioactivity will become harmless but the non-radioactive substances will persist over time. In principle, these hazardous substances may be quantified from traceability and quality controls performed during the production of the waste packages. As a consequence, a research and development program was initiated in 2007 with the aim to develop a nondestructive analytical technique for radioactive waste packages based on prompt and delayed gamma neutron activation analysis (P and DGNAA) employing a DT-neutron generator in pulsed mode. In a preliminary study it was experimentally demonstrated that P and DGNAA is suitable to determine the chemical composition of large samples. In 2010 a facility called MEDINA (Multi Element Detection based on Instrumental Neutron Activation) was developed for the qualitative and quantitative determination of nonradioactive, toxic elements and substances in 200-l steel drums. The determination of hazardous substances and elements is generally achieved measuring the prompt gamma-rays induced by thermal neutrons. Additional information about the composition of the waste matrix could be derived measuring the delayed gamma-rays from short life activation products. However a sensitive detection of these delayed gamma-rays requires that thermal neutrons have almost vanished. Therefore, the thermal neutron die-away-time has to be known in order to achieve an optimal discrimination between prompt and delayed gamma-ray spectra acquisition. Measurements Thermal neutron die-away times have been determined for the following cases: a) the empty chamber, b ) an empty 200-l steel drum, for a 200-l steel drum filled c) with concrete d) with polyethylene and e) with a mixture of polyethylene and concrete by measuring the prompt-gamma ray count rate of relevant isotopes like of {sup 1}H, {sup 10}B, {sup 12}C, {sup 28}Si, {sup 35}Cl, {sup 40}Ca and {sup 56}Fe which are emitted from different parts of the facility and the sample. Additionally, the average die-away-time was determined from the total detector count rate. The neutron generator was operated with a neutron emission of 8x10{sup 7} n.s{sup -1}, a neutron pulse with a length of 250 μs and a repetition time of 5 ms. The spectra were acquired between the neutron pulses over t{sub c}=500 μs after a pre-defined waiting time t{sub D} (multiple of 500 μs). The thermal neutron die-away time was ranging between 0.9 ms and 5 ms according to the sample composition. As an example the measured thermal neutron die-away-time Λ [μs] of a drum filled with concrete is presented. Detailed results of this study will be presented and discussed. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integral Measurement of the 237 Np($n$, γ) 238 Np Cross Section with Fast Neutrons

Accurate knowledge of the 237 Np($n$; γ) 238 Np cross section at fast neutron energies is important for applied nuclear science. The presently available experimental data has large disagreements in the fast neutron region. A measurement of the 237 Np($n$; γ) 238 Np cross section was performed using a well characterized fast neutron source and the results was compared with previous measurements and current nuclear data evaluations. This will provide an integral measurement that can be used as a benchmark for current evaluations. Multiple samples of 237 Np were irradiated in the Godiva-IV critical assembly. Following the irradiation, the samples placed in a γ-ray counting setup and the γ-rays emitted from the decay of 238 Np were measured over a time period of approximately 7 days. Multiple γ-ray decay branches of 238 Np were observed. The observed activity of 238 Np was used to calculate the amount of 238 Np produced during the irradiation via the 237 Np($n$; γ) 238 Np and an integral cross section of 359(10) mb was measured. The 238 Np half-life has been measured with a result of 50.34(7) hours. An integral measurement of the 237 Np($n$; γ) 238 Np cross section has been measured. This result has been compared to the calculated integral cross section using the ENDF/BVIII.0 and JENDL-4.0 evaluated cross sections and found to be in good agreement with ENDF/BVIII.0 value of 367 mb. The JENDL-4.0 evaluation yields a value of 312 mb, which is significantly lower than the measured cross section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DETERMINING NEUTRON STAR MASSES AND RADII USING ENERGY-RESOLVED WAVEFORMS OF X-RAY BURST OSCILLATIONS

Simultaneous, precise measurements of the mass M and radius R of neutron stars can yield uniquely valuable information about the still uncertain properties of cold matter at several times the density of nuclear matter. One method that could be used to measure M and R is to analyze the energy-dependent waveforms of the X-ray flux oscillations seen during some thermonuclear bursts from some neutron stars. These oscillations are thought to be produced by X-ray emission from hotter regions on the surface of the star that are rotating at or near the spin frequency of the star. Here we explore how well M and R could be determined by generating and analyzing, using Bayesian techniques, synthetic energy-resolved X-ray data that we produce assuming a future space mission having 2-30 keV energy coverage and an effective area of 10 m{sup 2}, such as the proposed Large Observatory for X-Ray Timing or Advanced X-Ray Timing Array missions. We find that waveforms from hot spots within 10° of the rotation equator usually constrain both M and R with an uncertainty of about 10%, if there are 10{sup 6} total counts from the spot, whereas waveforms from spots within 20° of the rotation pole provide no useful constraints. The constraints we report can usually be achieved even if the burst oscillations vary with time and data from multiple bursts must be used to obtain 10{sup 6} counts from the hot spot. This is therefore a promising method to constrain M and R tightly enough to discriminate strongly between competing models of cold, high-density matter.

79 ASTRONOMY AND ASTROPHYSICS↗

Neutron Screening Measurements of 110 gallon drums at T Plant

The Pacific Northwest National Laboratory (PNNL) Nondestructive Assay (NDA) Service Center was contracted to develop and demonstrate a simple and inexpensive method of assaying 110 gallon drums at the Hanford Site’s T-Plant. The drums contained pucks of crushed old drums used for storage of transuranic (TRU) waste. The drums were to be assayed to determine if they meet the criteria for TRU or Low Level Waste (LLW). Because of the dense matrix (crushed steel drums) gamma measurement techniques were excluded and a mobile, configurable neutron system, consisting of four sequentially connected slab detectors was chosen to be used for this application. An optimum measurement configuration was determined through multiple test measurements with californium source. Based on these measurements the initial calibration of the system was performed applying the isotopic composition for aged weapon-grade plutonium. A series of background and blank puck drum measurements allowed estimating detection limits for both total (singles) and coincidence (doubles) counting techniques. It was found that even conservative estimates for minimum detection concentration using singles count rate were lower than the essential threshold of 100 nCi/g. Whereas the detection limit of coincidence counting appeared to be about as twice as high of the threshold. A series of measurements intended to verify the technique and revise the initial calibration obtained were performed at the Waste Receiving and Processing (WRAP) facility with plutonium standards. Standards with a total mass of 0.3 g of plutonium (which is estimated to be equivalent of 100 nCi/g for net waste weight of 300 kg) loaded in the test puck drum were clearly detected. The following measurements of higher plutonium loadings verified the calibration factors obtained in the initial exercise. The revised and established calibration factors were also confirmed within established uncertainties by additional measurements of plutonium standards in various locations in the test drum. Due to necessity to dispense the blank test drum an alternative method of baseline determination was established during field measurements. Count rates of ambient background were corrected by the differences between observed background and blank test drum count rates which were previously determined over a series of measurements. Only 31 drums out of 352 counted during the intensive measurement campaign at T-Plant were determined to be Suspect TRU. 25 of these drums were re-measured at the WRAP facility using the SuperHENC. Of the 25 drums measured, 21 were confirmed to be TRU and the remaining four LLW.

neutron measurements, TRU waste, T-Plant, configur↗

Comparison of Measured and Simulated Neutron Counting with 3He Detectors and the Subcritical Water-Moderated UO2 7uPCX Assembly

An experiment designed to compare neutron noise analysis techniques on subcritical assemblies using differing neutron detector designs was developed as a collaborative effort between the Institut de radioprotection et de surete nucleaire (IRSN), Los Alamos (LANL), Lawrence Livermore (LLNL), and Sandia National Laboratories. This experiment has the final goal of characterizing neutron noise analysis accuracy in determining multiplication in light water systems for various neutron detection systems. This experiment utilized the Seven Percent Critical Experiment (7uPCX) facility at Sandia National Laboratories. The 7uPCX is an assembly designed to investigate light water systems with fuel enrichment above 5% and is able to use square or hex grid plates with varying pitches.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of Feynman Variance-To-Mean Measurements Using Measured and Simulated Data

Measured and simulated list-mode data from the NPOD detector system were compared for subcritical systems. Five BeRP ball configurations reflected by polyethylene are investigated in this work. The simulated data were calculated using the MCNP multiplication patch developed at LANL. In addition to comparing the moments of the counting distributions, a full analysis was conducted to infer the multiplication of each system using both the Hansen-Dowdy and Hage-Cifarelli formulisms. Several of the parameters that are input into these methods were also varied to determine their affect on the system multiplication. The main parameters investigated included the system source strength, reflector transmission, and the average number of neutrons released per 239 Pu fission ($\nu$). It is shown that when comparing the measured and simulated data while using the same method and parameters the inferred multiplication values agree within 5%. The measured and simulated multiplication values differ more as the reflector thickness increases. The moments for the simulated data were higher than the measured data for all of the configurations and also disagreed more as the reflector thickness increased. The analysis method and parameters used can lead to a large spread of inferred multiplication values. In the future more configurations will be analyzed in a similar manner and a detailed uncertainty analysis will be performed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗