Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NIST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Systematic correction of the density functional theory spectra via a quantum Monte Carlo approach

Numerical outputs and driver scripts supporting auxiliary-boson corrected diffusion Monte Carlo (ABCDMC) benchmarks on second-row neutral atoms, cations, and dications, plus a C2 molecule active-space study. Includes NIST reference energies, ABCDMC timestep extrapolation summaries, orbital generation inputs, singles-only CASCI driver scripts, an O-atom basis-set convergence study, and the PyQMC boson code snapshot used for the calculations.

36 MATERIALS SCIENCE↗

Total metals & anion concentration data; Slate River floodplain, Crested Butte, CO; May 2020-September 2020

This data package includes processed and undiluted measurements for metal and anion concentrations from pore water (groundwater) samples from the Slate River floodplain of Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and September of 2020. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS:Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA.The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solution (Sigma-Aldrich Multielement standard solution for ICP, St. Louis, MO) using matrix matched to sample solutions (either 2% HCl or HNO3 from AriStar Plus,grade acids from VWR Scientific). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace Elements in Water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. An internal standard (Rh) is added via on-line addition into the sample line using a mixing tee.Analysis by Ion Chromatography (Anions):The protocol follows Method 4110 in Standard Methods for Examination of Water and Wastewater.The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with isocratic method using sodium carbonate eluent. Detection is by chemical suppression of eluent conductivity. Quality control solutions and mixed analyte standards purchased from Inorganic Ventures, Christiansburg, VA.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Total metals, carbon, nitrogen & anion concentration data; Slate River & East River floodplains, Crested Butte, CO; May 2022-October 2022

This data package includes processed and undiluted measurements for metal, total carbon, total nitrogen, and anion concentrations from pore water (groundwater) and surface water samples from the Slate River and East River floodplains of Crested Butte, CO, focus field sites for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and October of 2022. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS (metals):Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA. The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solutions (SPEX Certiprep, Metuchen, NJ). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace elements in water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. Lastly, a suitable internal standard (usually Rh, In, Ga or Ge) is added using on-line addition into the sample line and mixing tee.Analysis by Shimadzu TOC-L (TOC/TN):The TOC-L system is a combustion technique where liquid samples are injected and combusted into CO2 for carbon detection by non-dispersive infrared (NDIR) and NO for detection by chemiluminescence. A calibration curve using five standard solutions between 0.1 and 7 ppm for carbon and 0.05 and 3.5 ppm for nitrogen is made for each type of measurement with a linearity >0.99. All samples, standards, and QC’s are prepared in 24mL scintillation vials that have been baked for 4hrs at 475 Cº and made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.Analysis by Ion Chromatography (Anions):The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with sodium carbonate eluent. A calibration curve using five standard solutions between 5 and 250 umol/L is made with a linearity >0.99. Standards and QC’s are prepared in 15mL polypropylene conical tubes, pipetted along with the samples into 1.5mL polypropylene vials. Dilutions are made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Strengthening the Security of Operational Technology: Understanding Contemporary Bill of Materials

The evolution of cyber-physical infrastructure has made its security more challenging. The last few years have witnessed a convergence of hardware and software segments in various domains, including operational technology (OT) which is responsible for carrying out critical tasks such as monitoring and controlling power grids, nuclear plants, transportation, and emergency services. Both hardware and software encapsulate numerous open source and proprietary subcomponents, making it crucial for end-users to understand the composition of the products they are using. For example, wind turbines incorporate thousands of lines of code (software) used for the turbine's design, planning, operation, and analytics in addition to the numerous hardware subcomponents that construct it. Due to the highly complex nature of software and hardware, knowledge of the components and subcomponents is required to mitigate cyber vulnerabilities and defend against cyberattacks. There has also been a transformation from a traditional linear supply chain into a global, dynamic, diverse, and interconnected system. The digitization of the supply chain makes it easier to find and exploit vulnerabilities. Critical infrastructures (e.g., power grids, oil, natural gas, water, and wastewater) rely on OT to function, and if the OT is compromised, equipment damage and potential interruption of services could result. A significant security measure to protect OT systems from disruption is to develop a supply chain bill of materials (BoM) corresponding to the software and hardware used in OT, along with attestations amongst vendors and asset owners. A supply chain BoM is a proactive way to understand the inherent vulnerabilities in the system and mitigate them in advance of being exploited. BoMs bolster the trust placed in the digital infrastructure and enhance software supply chain security by sustaining the management of component obsolescence and compliance, along with the seclusion of unsafe segments of a specific product. Adopting BoM tools is becoming increasingly important across various government sectors, as evidenced by the recent U.S. executive order on cybersecurity (NIST 2021). This paper aims to classify BoMs based on structure, functionality, component type, and architecture. The work also discusses case studies to further highlight the benefits of BoMs. In addition, it identifies missing pieces in existing BoM implementations so that future research may identify bounds on where it could expect to make improvements and directly enable researchers to identify promising areas for exploration. Further, the authors provide valuable recommendations to tool developers, researchers, and standardizing organizations (policymakers), additionally benefitting critical infrastructure owners and government executives. This aids in paving a path for future work, thereby, providing suggestions to determine a tool for consumers that best suit their needs.

97 MATHEMATICS AND COMPUTING↗

Semantic Interoperability to Enable Smart, Grid-Interactive Efficient Buildings

Achieving a widespread transition to grid-interactive, efficient buildings (GEBs) depends critically on there being sufficient interoperability among connected building systems. While many critical elements already exist at the technical interoperability level (TCP/IP, BACnet, etc.), a lack of interoperability in the semantic level hinders streamlined integration of interdependent applications. Semantics refers to expressing information about “things” in a way that can be consistently understood by applications. Key components of formalized semantics include identifying what a “thing” is (its “type”), defining general information about that “thing” (its characteristics or properties), and defining the appropriate relationships of that “thing” to other “things” (its function or role in a larger system). Although this might seem initially trivial, the success of smart building applications is highly dependent on maintaining consistent self-descriptive notions of the “things”. Without semantic interoperability, it is technically difficult, labor-intensive, and cost-prohibitive to enable three key objectives of GEBs: optimizing performance, automatically identifying and diagnosing faults, and delivering grid services. Industry, academia, and standards bodies have invested effort in developing information models to facilitate semantic interoperability, however, they have not been widely adopted across the U.S. commercial building portfolio. This paper will present a pathway to drive semantic interoperability through a three-pronged approach to be led by the DOE Building Technologies Office in partnership with NIST and multiple national laboratories comprising: 1) industry engagement and coordination across existing efforts; 2) a semantic interoperability standard that empowers building owners to identify and require interoperable attributes when procuring equipment and applications; 3) tools to assist in implementation and a test framework to verify compliance of products with semantic interoperability specifications. This approach is designed to accelerate the timeline for adoption of semantic interoperability specifications. The intent is to reduce soft costs associated with implementing advanced controls, fault detection and diagnostics, and other smart building technologies and use cases as a necessary step in achieving an energy efficient smart grid future.

Bergmann, Harry↗

Verification and Validation of the STAT7 Code

This document presents the verification and validation of the STAT7 Version 1.0 code which has been developed to perform the steady-state thermal hydraulic safety calculation of the MIT Research Reactor required upon conversion of the reactor from high enrichment uranium fuel to low enrichment uranium fuel. The key capabilites of the code including the statistical processing, water property generation, and thermal hydraulic solution are verified independently. While the first two capabilites are checked using statistical tests and NIST data tables, each component of the thermal hydraulic solution is verified using simple geometry test problems. The comparison between results obtained by the code and hand calculations on these problems shows that each of these components work correctly. Additionally, a comprehensive comparison between STAT7 Version 1.0 and PLTEMP/ANL Version 4.2 calculations for a five-channel test problem is performed for the validation. The good agreement between the obtained results for all thermal hydraulic parameters belonging to the fuel core region is achieved. An issue in bypass flowrate calculation was detected when both fin-friction and bypass flow claculations are involved. This problem can be corrected in a later version of the code, however, does not affect the application of STAT7 code as it has been used to date where the flow distribution in the core region and bypass channel is specified as an input parameter.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

National-Tribal Critical Infrastructure Protection: Collaboration for Extraordinary National Security Benefit

This paper examines national and tribal collaborative opportunities to get ahead of the critical infrastructure insecurity problem. Recommendations are viewed through the lens of the Sandia Labs Tribal Cyber-Energy initiative and national security projects. Recommendations include 1) Collaboratively address national priority and shared challenges to gain faster and better solutions to national priority problems on a smaller yet comprehensive American Indian and Alaskan Native sovereign single-point of authority scale 2) Utilize newer standards-based technologies to provide scalable, capable, and manageable solutions for greatly expanded and connected national critical infrastructures 3) Employ Cyber-Physical-Resilient design preliminary analysis to define concept- to-disposition design requirements for preemptive critical infrastructure risk mitigation and baked-in security; 4) Develop data-centric protection to provide increased information asset protection as data shifts from data-owner operated on-premises infrastructure to virtual service provider data-steward owned and operated off-premises infrastructure; and 5) Balance shared solutions with the National Institute of Science and Technology (NIST) Cybersecurity and Risk Management frameworks, and the System Security Engineering Guidelines. As yet unallocated federal funding would support research, development, the timely application of National-Tribal critical infrastructure protection, and critical infrastructure Cyber disruption response and recovery with extraordinary mutual benefits for the foreseeable future. The Critical Infrastructure Insecurity Problem: Rapid modernization and expansive connectivity are due to advances in Information and Communications Technologies that have sweeping cyber impact across all critical infrastructure sectors. Supervisory Control and Data Acquisition and Industrial Control Systems are particularly impacted as systems long separated from the Internet are now being connected and computerized. Virtualization and mobility create a Data Everywhere-User Anywhere paradigm that has evaporated the enterprise network perimeter. There are multi-front technological challenges at play, where long depended on technologies simply don't scale to current needs resulting in a digital dichotomy of competing old and new standards. New standards-based technologies scale but are not as well-known or as widely deployed, which leaves decision makers, stakeholders, and the workforce in a quandary, caught mid-stream between the technological past and the virtual future. Rapid and expansive cyber threat accompanies disruptive change in connectivity and computational dependencies. A lack of action will exacerbate the problem if new technologies roll out without baked-in security design. The Risk: If National-Tribal CIP collaboration to design in security is not done, then an ongoing state of insufficient bolt-on security and elevated threat exposure will remain for years to come.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

100th Anniversary of the discovery of Ferroelectricity: How did it impact the Current Day Physics

Ferroelectric phenomenon in materials was identified for the first time about 100 years ago in 1920 (paper presented at the American Physical Society (APS) Meeting in Washington, DC, April 1920), at the University of Minnesota, MN, USA; by then a graduate student Joseph Valasek working under the supervision of Prof. W. F. G. Swann. Before this announcement, some prominent physicists had envisaged and even predicted the possibility of an analogous electrical behavior in some materials to that of the well-established hysteresis behavior of magnetic materials. Debye’s work tried to put the concept of Curie temperature in some solids in 1912 but it Schrodinger in the same year who formalized the term ferroelectricity. The names ferroelectrics, ferroelectricity, etc. are fully symbolic of the hysteresis loop-like behavior originally displayed by the magnetic materials. Later on when the physics of ferroelectrics was formalized, most of the terminology, e.g. Curie constant, Curie temperature, etc. that characterized the hysteresis loop or its related characteristics, was inherited from the magnetic materials. Over the years basic ferroelectricity concepts were significantly developed. The observed ferroelectric hysteresis loop between electric polarization vs applied electric field in the then well-known material, Rochelle salt, was presented at the April meeting of the APS, held at, then known as, the National Bureau of Standards or NBS (currently known as the National Institute for Standards and Technology or NIST). Interestingly, even though Valasek submitted the abstract but it was presented by Swann (and Valasek was not present). It happened to be a unique case of the earlier predictions but it did not catch the attention of many researchers working in the field of electronics. Whatever the reason, there was a little attention paid to this newly identified effect in Rochelle salt in 1920s. In late 1920, Valasek’s paper was submitted to Physical Review and that appeared in April 1921. Both ferroelectricity and ferromagnetism are the observational or experimental characteristics of a special class of materials which were not predicted by any basic theoretical approaches to start with at that time.

36 MATERIALS SCIENCE↗

Equations of State in Computational Physics: What, Why, and How

Summary: 1. Equations of state furnish thermodynamic properties of a material. 2. Usually involve P, p (or V), and T, or P, r, and E 3. Necessary ingredient to solve compressible flow problems. 4. Varieties: i. Analytical expressions (ideal gas, Grüneisen) – fast, convenient for verification and test problems ii. Graphs and charts – good for hand calculations iii. Tables and databases – generally most accurate, require interpolation i. Steam tables ii. NIST database iii. SESAME EOS Library 5. Constructed by using semi-empirical models from Statistical Mechanics and fitting to available data

36 MATERIALS SCIENCE↗

Side Channel Considerations for SHA-512

We consider a theoretical side-channel attack on SHA-512; the attack should easily generalize to other algorithms in the SHA-2 family. Rather than looking at a side-channel attack on an HMAC, which has been done in various papers, we assume that the targeted device is applying the hash function as a pseudo-random function (prf) in order to generate a secret key from a secret seed, as recommended by NIST. The analyst uses side-channel information to try to recover the secret seed. We use entropy/information theory to show how one might judge whether or not a side-channel attack might be possible and/or feasible, and we show how the design of the implementation can affect the feasibility of an attack.

97 MATHEMATICS AND COMPUTING↗

Tracer gas test in Net-Zero Energy Residential Test Facility

The Net-Zero Energy Residential Test Facility (NZERTF) at NIST was built in 2012 to support the development and adoption of cost-effective net-zero energy designs, technologies, and construction methods. It is two-story, and has four bedrooms, three bathrooms, and an open living room, dining room, and kitchen space. The NZERTF also has a basement and attic, both located within the conditioned space because the thermal and air-moisture barriers encompass the basement walls and attic roof. Transfer grilles link the living spaces to these two zones. The central heating and cooling system includes an air-toair heat pump, which delivers air to the basement, first and second floors. The heat pump has a cooling capacity of 7.6 kW and a heating capacity of 7.8 kW. The indoor unit is in the basement and ductwork runs along the basement ceiling. A balanced heat recovery ventilator (HRV) is installed in the basement and has its own dedicated ductwork. The HRV supplies 47 L/s of outdoor air to the house, with supplies on the first floor (in the kitchen/dining area) and in each of the three second-floor bedrooms. Air from the first-floor bathroom and both second-floor bathrooms is returned to the HRV before being exhausted, though the HRV was turned off during the tests. The house also has a range hood exhaust and a clothes dryer exhaust, both of which were turned off for the tests. The temperature of the house was measured and the operation of the space conditioning system, including its recirculating air distribution fan, were controlled by a commercially available thermostat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Verification and Validation of the STAT7 Code

This document presents the verification and validation of the STAT7 Version 1.0 code which has been developed to perform the steady-state thermal hydraulic safety calculation of the MIT Research Reactor required upon conversion of the reactor from highly enriched uranium fuel to low- enriched uranium fuel. The key capabilities of the code including the statistical processing, water property generation, and thermal hydraulic solution are verified independently. While the first two capabilities are checked using statistical tests and NIST data tables, each component of the thermal hydraulic solution is verified using simple geometry test problems. The comparison between results obtained by the code and hand calculations on these problems shows that each of these components work correctly. Additionally, a comprehensive comparison between STAT7 Version 1.0 and PLTEMP/ANL Version 4.2 calculations for a five-channel test problem is performed for the validation. The good agreement between the obtained results for all thermal hydraulic parameters belonging to the fuel core region is achieved. An issue in bypass flowrate calculation was detected when both fin-friction and bypass flow calculations are involved. This problem can be corrected in a later version of the code. However, it does not affect the application of STAT7 as it has been used to date where the flow distribution in the core region and bypass channel is specified as an input parameter.

97 MATHEMATICS AND COMPUTING↗

Thermal Hydraulic Experimental Test Article (FY2020 Status Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2. The design work for the facility has been completed. Since the FY19 THETA status report, the THETA primary system components have been assembled and tested using de-ionized water. Some results of this testing at select Richardson and Reynolds numbers are included herein. The custom THETA sodium flowmeter (permanent magnet submersible sodium flowmeter) has been built and calibrated using sodium in an auxiliary facility against a NIST traceable vortex shedder type flowmeter. The permanent magnet flowmeter showed excellent performance, following the theoretical equation for measured voltage quite well, with an error < 3.5% at flow rates ranging from 3-24 GPM at temperatures up to 400 °C. The secondary sodium system for heat rejection from intermediate heat exchanger has been analyzed according to ASME code. All secondary side piping, fittings and a U-stamped air-to-sodium heat exchanger have been procured.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Synthesis and Single Crystals of Refractory Oxides of Lanthanides and Thorium

At the completion of this program, we can report that we developed a considerable degree of technical improvements in our ability to perform hydrothermal reactions at high temperatures and pressures. We can now routinely perform reactions at 700-750°C and 200 MPa. Currently we are in the process of exploiting this new technology synthesizing a range of exotic new materials investigating relatively poorly understood materials. Our initial efforts focused on the chemistry of rare earth oxides with tetravalent and pentavalent oxides. We recently published a study of the lanthanides with Nb 5+ and Ta 5+ ions, where we grew oxides such as RENdO 4 and RETaO 4 as high quality single crystals. These compounds were targeted as potential hosts for luminescent and scintillation materials, particularly given that they are among the densest oxide hosts and hence have good potential as absorbers for high energy radiation like X-rays and gamma rays. We also isolated a range of unusual new rare earth tantalates with very complex structures. indicating that the chemistry is very sensitive to conditions. We performed some fairly comprehensive examinations of the solid-state chemistry of rare earth ions with various tetravalent metal ions especially Si 4+ , Ge 4+ , Sn 4+ and Ti 4+ . Given the potential role of rare earth silicates in immobilizing radioactive waste elements in long-term storage, and the similarity of our hydrothermal fluids with known geological conditions, this chemistry continues to be relevant. We prepared an extensive series of new lanthanide germanates (e.g. RE 13 Ge 6 O 31 (OH), BaRE 10 (GeO 4 ) 4 O 8 ). and found that there is there is almost no overlap between the chemistry of the rare earth silicates. Stannic oxide (SnO 2 ) is much more refractory and requires higher temperatures and of mineralizer concentrations. One significant result is the growth of RE 2 Sn 2 O 7 pyrochlore single crystals. These are of interest because the rare earth stannate pyrochlores are known to display a wide range of magnetic frustration such as spin ice behavior. We grew high quality single crystals of rare earth germanate and stannate pyrochlores and this led to a collaboration with Professor Kate Ross at Colorado State. Preliminary measurements, indicate that the crystals contain no detectable defects or site disorder. Initial neutron diffraction on single crystals was performed at Oak Ridge, and more detailed experiments involving the Ross group are underway at both NIST and ORNL. This particular chemistry has turned out to be the most potentially significant work on this project and the collaborative effort with Prof. Ross is the topic of a DoE renewal project on quantum materials. Our initial foray into the hydrothermal chemistry of rare earth titanates has also been very promising and a range of cubic and polar ferroic phases of the light rare earths RE 2 Ti 2 O 7 (RE = La - Pr) in the P2 1 phase. We also discovered an interesting new phase Ce 2 Ti 4 O 11 that can have implications in heavy metal immobilization and storage. along with a series of new rare earth titanates (La 5 Ti 4 O 15 (OH) Sm 3 TiO 5 (OH) 3 and Lu 5 Ti 2 O 11 (OH) with exceptionally complex structures. One interesting sidelight has been high temperature hydrothermal chemistry terbium, including the growth of large crystals of TbO(OH). This is not a new compound but it is the first time it has been grown as large single crystals. The Tb atom density is almost as high as that in Tb 2 O 3 and has a very high Verdet constant (ca. 70), making it a very attractive candidate as a Faraday rotator. Unfortunately it is not in a cubic structure but he material is hard, stable, pure and inexpensive, so should still be an attractive Faraday oscillator. We recently received a patent on this material. We also synthesized K 2 Tb(Ge 2 O 7 ) containing stable octahedral Tb 4+ ions, which appears to be the first example of a well-characterized Tb 4+ complex. Given that Tb 4+ has been proposed as a benign surrogate for more treacherous tetravalent ions such as Cf 4+ and Bk 4+ , we think that Tb 4+ silicates can be a particularly useful study for actinide immobilization and related work. We also began reaction studies with rare earths and both ReO 2 and RuO 2 . These resulted in large single crystals of species like RE 5 Ru 2 O 12 , RE 4 Re 2 O 11 , REReO 4 and RE 2 ReO 5 . Several of these samples have already been sent to ORNL for magnetic and neutron diffraction studies.

36 MATERIALS SCIENCE↗

Two-Phase Equation of State for Al 2 O 3

Two-phase equation of state (EOS) for AI 2 O 3 (alumina) is calibrated using the experimental/simulation calibration data uploaded to the caldata repository. The two phases are solid α-Al 2 O 3 (corundum, sapphire, ruby) and its melt. The enthalpy of formation is set to that available from the NIST-JANAF database at T = 0K, P =1 bar. The expected applicability range of the EOS is from the ambient conditions to temperatures of ~ 5000 K and pressures of ~ 50-100 GPa.

36 MATERIALS SCIENCE↗

Using the CYBER-Champ Model to Determine Cyber Competencies and Role Alignment

Cybersecurity roles, tasks, and skills are seen by many organizations as nonessential, abstract, or complicated. Although standards are in place, such as the National Institute of Standards and Technology (NIST) 800-181 document titled “Workforce Framework for Cybersecurity (NICE Framework)” available since September 2012, companies are still showing security vulnerabilities in their cyber networks (Hatzes, 2020). Barriers towards creating a cyber-ready workforce are not always due to a lack of resources, but often caused by organizational structure. The need for cyber-cognizant job postings, improved communication between Operational Technology (OT) and Information Technology (IT) employees, increases in staffing and funding for cyber teams, and better communication of standards and training can all contribute to increasing an organization’s cyber resilience. Cybersecurity Competency Health and Maturity Progression model (CYBER-CHAMP) is a model aimed at evaluating an organization’s structure and individual employee’s cyber knowledge and helps develop a plan to reach competency. This model was used to engage with organizations to promote proper cyber protocols and policies. The aim of this paper is to answer if it is possible for an organization to build a cyber-ready workforce by providing education and training options for current employees and prepare the future workforce to be ready on day one of employment. Both open source and firsthand interviews with organizations were used to conduct the research contained in this document. Further research may include additional development to the CYBER-CHAMP model and its delivery platform.

99 GENERAL AND MISCELLANEOUS↗

Report on High Energy Arcing Fault Experiments: Experimental Results from Low-Voltage Switchgear Enclosures

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena for low-voltage metal enclosed switchgear containing aluminum conductors. This report covers full-scale laboratory experiments using representative nuclear power plant (NPP) three-phase electrical equipment. Electrical, thermal, and pressure data were recorded for each experiment and documented in this report. This report covers experiments performed on two low-voltage switchgear units with each unit consisting of two vertical sections. The data collected supports characterization of the low-voltage HEAF hazard and these results will be used to support potential improvements in fire probabilistic risk assessment (PRA) methods. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the NRC, the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setup and execution. The HEAF experiments were performed between August 26 and Augsut 29, 2019 on nearidentical Westinghouse Type DS low-voltage metal-enclosed indoor switchgear. The threephase arcing fault was initiated on the aluminum main bus or in select cases on the copper bus stabs near the breaker. These experiments used either nominal 480 volts AC or 600 volts AC. Durations of the experiments ranged from approximately 0.4 s to 8.3 s with fault currents ranging from approximately 9.2 kA to 19.3 kA. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers, radiometers, and slug calorimeters at various locations around the electrical enclosures. Environmental measurements of breakdown, conductivity and electromagnetics were also taken. The experiments were documented with normal and high-speed videography, infrared imaging and photography. The results, while limited, indicated the difficulty in maintaining and sustaining low-voltage arcs on aluminum components of sufficient duration and at a single point as observed operating experience.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗