Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mix Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Effect of Curing Temperature and Composition on the Performance Properties of Saltstone - 12473

When freshly mixed Saltstone is placed into a vault at the Savannah River Site, the heat of hydration produced during curing causes the temperature of the grout to increase. It is not uncommon for the temperature of the grout to increase by 30 to 50 deg. C above the starting temperature depending on the vault size and location, environmental conditions and pour schedule. For example, temperatures measured by thermocouples in one cell have exceeded 70 deg. C. The elevated temperatures, once reached, can extend for weeks or even months. Recent studies at Savannah River National Laboratory (SRNL) have shown that curing simulated Saltstone mixes at elevated temperatures can lead to reduced compressive strength and dynamic Young's modulus as well as increased total porosity when compared to the same grout mixes cured at 20 deg. C. Samples cured at 60 deg. C can have hydraulic conductivities approximately 600 times greater than samples cured at 20 deg. C. Previous studies have shown that the 60 deg. C cured mix had a dynamic Young's modulus that was half that of the mix cured at 20 deg. C. However, high temperature curing may not always have negative effects on the performance properties of the grout. These results indicate that higher curing temperatures can significantly alter the performance properties that are inputs for the Saltstone Performance Assessment. The Saltstone formulation (mix design) must produce a grout waste form that meets both placement and performance properties. A statistically designed set of mixes was developed to determine key process and compositional factors that affect the performance properties of Saltstone grout. A total of 27 mixes were batched and tested. There are eight baseline mixes that contain high and low values of aluminate concentration, varying w/p ratio, and varying fly ash content in the premix. Each of the eight mixes was cured at 22, 40 and 60 deg. C. The three additional reference mixes batched at the beginning, middle and end of testing showed good reproducibility throughout the study. The results of varying the operational and compositional factors on the performance properties of Saltstone grout are: - The Young's modulus is inversely affected by the curing temperature of the grout. - The aluminate content of the salt solution increases the Young's modulus of the Saltstone for samples cured at 20 and 40 deg. C. - All grouts cured at 60 deg. C have low Young's moduli and the composition of the grout mix did not have any positive effects on the performance properties after curing at this temperature. - The fly ash content in the premix had not discernible effect on the Young's modulus. - The water to premix ratio does not affect the Young's modulus. - Grouts made with the high aluminate salt solution have lower hydraulic conductivities than those made with the low aluminate simulant. - Temperature has an inverse effect on the hydraulic conductivity. - In general, increasing the water to premix ratio and the fly ash content will increase the hydraulic conductivity. - The porosity and cured density of the Saltstone grout are primarily a factor of the water to premix ratio of the grout formulation. The correlation between hydraulic conductivity and Young's modulus investigated in previous studies was evaluated further in this report. The current data as well as data from previous studies was fitted by a second degree polynomial function with a 77.1 % R-squared value. This model can be used to estimate the hydraulic conductivity of a sample based its Young's modulus for a limited range (E values up to 7 GPa). More data points should be included to further define the relationship between these performance properties are high Young's moduli and low hydraulic conductivities. The Young's modulus should still be measured on grouts formulated in future studies to be used as screening method for samples to be sent for hydraulic conductivity measurements. Saltstone grout has a complicated microstructure that is affected by the composition of the salt solution, the dry feed mixture composition, and the conditions under which it cures. The performance properties investigated are interrelated, which can make it difficult to determine individual relationships between various factors. Porosity is a large factor in determining both the Young's modulus and the hydraulic conductivity of the samples. Although the cured density is a straightforward measurement, it is not a significant performance property that needs further investigation. The porosity measurement provides similar and more meaningful data in relation to other performance properties. Based on the results of this study, the aluminate content of the salt solution does have an effect on the Young's modulus and the hydraulic conductivity and its effects should continue to be investigated. However, a new projection of aluminate contents should be used since projections change over time. The variability of fly ash in the premix did not prove to be a contributing factor that effects the performance properties of Saltstone and does not need to be included in future studies unless significant deviations from the baseline mix are proposed. The water to premix ratio has a significant effect on the performance properties of interest and the effects of varying this factor need further investigation. It is recommended that smaller ranges of w/p are investigated in order to provide data that is more relevant to the Saltstone being placed in the vaults. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Program to design, fabricate, test, and deliver a thermal control-mixing control device for the George C. Marshall Space Flight Center

The development and testing of a temperature sensor and pulse duration modulation (PDM) diverter valve for a thermal control-mixing control device are described. The temperature sensor selected for use uses a fluidic pin amplifier in conjunction with an expansion device. This device can sense changes of less than 0.25 F with greater than 15:1 signal to noise ratio when operating with a typical Freon pump supplied pressure. The pressure sensitivity of the sensor is approximately 0.0019 F/kPa. The valve which was selected was tested and performed with 100% flow diversion. In addition, the valve operates with a flow efficiency of at least 95%, with the possibility of attaining 100% if the vent flow of the PDM can be channeled through the last stage of the diverter valve. A temperature sensor which utilized an orifice bridge circuit and proportional-vortex combination mixing valve were also evaluated, but the concepts were rejected due to various problems.

Thurston, T. S.↗

Non-destructive testing using two-component/two-wave mixing interferometer

A new laser-based ultrasonic (LBU) receiver was recently introduced. The novel architecture is based on two-wave mixing in photorefractive materials and allows simultaneous measurement of in-plane and out-of-plane displacements (two- component). By taking advantage of recent developments in electronic processing and our knowledge on multi-channel interferometer, we achieved a compact optical system using only a single collecting aperture and a single laser probe beam. We will characterize the system performances and present experimental results demonstrating the capability for this compact two-component interferometer.

42 ENGINEERING↗

An automated lab-scale flue gas permeation membrane testing system at the National Carbon Capture Center

A constant pressure, mixed gas permeation testing skid was deployed at the National Carbon Capture Center to test membrane performance when continuously exposed to slipstream post-combustion flue gas. Small, laboratory scale membranes can be loaded for testing and the degree of automation allowed the skid to be run unattended for several weeks at a time. In this report, we share our experience in commissioning the skid and quantifying CO 2 , N 2 and O 2 permeances of several membranes during the first round of testing. Dense films of polydimethylsiloxane and poly(bistrifluoroethoxyphosphazene) were tested with flue gas for approximately 20 h each. Here, in addition, we successfully tested four thin film composite hollow fiber membranes made by a dip coating process, consisting of porous Torlon hollow fibers coated with a selective layer of poly(bistrifluoroethoxyphosphazene) or its mixed matrix with a metal organic framework SIFSIX-Cu-2i filler particles. Initial results suggest the polydimethylsiloxane showed comparable results to the literature data, but the coated hollow fiber membranes have lower CO 2 permeances relative to N 2 or O 2 permeances compared to their performance under idealized, dry, contaminant-free mixed gas conditions. While quantification of H 2 O permeance was performed, we found it was affected by concentration polarization even with small membrane area and a low stage cut.

47 OTHER INSTRUMENTATION↗

Atomization and Mixing Study

The primary objective was the obtainment of atomization and mixing performance data for a variety of typical liquid oxygen/hydrocarbon injector element designs. Such data are required to establish injector design criteria and to provide critical inputs to liquid rocket engine combustor performance and stability analysis, and computational codes and methods. Deficiencies and problems with the atomization test equipment were identified, and action initiated to resolve them. Test results of the gas/liquid mixing tests indicated that an assessment of test methods was required. A series of 71 liquid/liquid tests were performed.

Ferrenberg, A.↗

Integrated Data Collection Analysis (IDCA) Program - Mixing Procedures and Materials Compatibility

Three mixing procedures have been standardized for the IDCA proficiency test—solid-solid, solid-liquid, and liquid-liquid. Due to the variety of precursors used in formulating the materials for the test, these three mixing methods have been designed to address all combinations of materials. Hand mixing is recommended for quantities less than 10 grams and Jar Mill mixing is recommended for quantities over 10 grams. Consideration must also be given to the type of container used for the mixing due to the wide range of chemical reactivity of the precursors and mixtures. Eight web site sources from container and chemical manufacturers have been consulted. Compatible materials have been compiled as a resource for selecting containers made of materials stable to the mixtures. In addition, container materials used in practice by the participating laboratories are discussed. Consulting chemical compatibility tables is highly recommended for each operation by each individual engaged in testing the materials in this proficiency test.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Enhanced Injection and Mixing Project at NASA Langley

An overview of a research project aimed at enhancing fuel injection and mixing for scramjet engines at flight Mach numbers greater than 8 is presented. The specific objectives of this project are to increase knowledge and understanding of the fundamental physics governing scramjet fuel-air mixing, to develop strategies for improving injector performance and to develop functional relationships between mixing efficiency, losses due to mixing (such as total pressure loss, drag) and combustor/mixing length. The research approach consists of a closely coupled experimental and computational effort with experiments intended for exploring injection concepts and for anchoring computational fluid dynamics (CFD) simulations. The experiments are being conducted in the NASA Langley Arc-Heated Scramjet Test Facility and consist of helium injection into a Mach 6 air stream. Measurements include in-stream helium mole fraction, Pitot pressure, and total temperature as well as wall pressures and temperatures. Additionally, nitric oxide planar laser-induced fluorescence (NO PLIF) imaging will be used for flow visualization of the fuel plume. The numerical simulations, performed with the VULCAN CFD code, provide flowfield details unobtainable from the experiment. The current paper describes the experimental apparatus and diagnostic systems which have been developed and/or tested in preparation for the mixing tests and discusses numerical simulations performed to reduce the risk associated with the experimental design.

K F Cabell↗

Concentration Distributions during Pulse Jet Mixing

Obtaining real-time, in situ slurry concentration measurements during unsteady mixing can provide increased understanding into mixer performance. During recent tests an ultrasonic attenuation sensor was inserted into a mixing vessel to measure the slurry concentration during unsteady mixing in real time during pulse jet mixer operation. These pulse jet mixing tests to suspend noncohesive solids in Newtonian liquid were conducted at three geometric scales. To understand the solids suspension process and resulting solids distribution, the concentration of solids in the cloud was measured at various elevations and radial positions during the pulse jet mixer cycle. In the largest scale vessel, concentration profiles were measured at three radial locations: r = 0, 0.5 and 0.9 R where R is the vessel radius. These radial concentration data are being analyzed to provide a model for predicting concentration as a function of elevation. This paper describes pulse jet mixer operation, provides a description of the concentration probe, and presents transient concentration data obtained at three radial positions: in the vessel center (O R), midway between the center and the wall (0.5 R) and near the vessel wall (0.9 R) through out the pulse to provide insight into pulse jet mixer performance.

42 ENGINEERING↗

Real-time data acquisition system assists engine test program

The mixed-fuels program examined included two major phases: the development of a reformer that would provide an onboard source of hydrogen, and the testing of induction systems and mixed fuels on a conventional V8 engine to verify the concept and define the system's potential. The discussion is limited to the engine testing phase. The testing program is reviewed and the effectiveness of an IDAC data acquisition system in supporting the engine testing program is demonstrated. The data system's application is illustrated by examples.

Griffin, D. C., Jr.↗

Exploratory tests of two strut fuel injectors for supersonic combustion

Results of supersonic mixing and combustion tests performed with two simple strut injector configurations, one with parallel injectors and one with perpendicular injectors, are presented and analyzed. Good agreement is obtained between static pressure measured on the duct wall downstream of the strut injectors and distributions obtained from one-dimensional calculations. Measured duct heat load agrees with results of the one-dimensional calculations for moderate amounts of reaction, but is underestimated when large separated regions occur near the injection location. For the parallel injection strut, good agreement is obtained between the shape of the injected fuel distribution inferred from gas sample measurements at the duct exit and the distribution calculated with a multiple-jet mixing theory. The overall fraction of injected fuel reacted in the multiple-jet calculation closely matches the amount of fuel reaction necessary to match static pressure with the one-dimensional calculation. Gas sample measurements with the perpendicular injection strut also give results consistent with the amount of fuel reaction in the one-dimensional calculation.

Anderson, G. Y.↗

Suppression of Cavity-Driven Flow Separation in a Simulated Mixed Compression Inlet

A test facility designed to simulate a bifurcated subsonic diffuser operating within a mixed compression inlet is described. The subsonic diffuser in this facility modeled a bypass cavity feature often used in mixed compression inlets for engine flow matching and normal shock control. A bypass cavity-driven flow separation was seen to occur in the subsonic diffuser without applied flow control. Flow control in the form of vortex generators and/or a partitioned bypass cavity cover plate were used to eliminate this flow separation, providing a 2% increase in area-averaged total pressure recovery, and a 70% reduction in circumferential distortion intensity.

Wendt, Bruce J.↗

Hot-flow tests of a series of 10-percent-scale turbofan forced mixing nozzles

An approximately 1/10-scale model of a mixed-flow exhaust system was tested in a static facility with fully simulated hot-flow cruise and takeoff conditions. Nine mixer geometries with 12 to 24 lobes were tested. The areas of the core and fan stream were held constant to maintain a bypass ratio of approximately 5. The research results presented in this report were obtained as part of a program directed toward developing an improved mixer design methodology by using a combined analytical and experimental approach. The effects of lobe spacing, lobe penetration, lobe-to-centerbody gap, lobe contour, and scalloping of the radial side walls were investigated. Test measurements included total pressure and temperature surveys, flow angularity surveys, and wall and centerbody surface static pressure measurements. Contour plots at various stations in the mixing region are presented to show the mixing effectiveness for the various lobe geometries.

Head, V. L.↗

Reproducible direct exposure environmental testing of metal-based magnetic media

A flow geometry and flow rate for mixed flowing gas testing is proposed. Use of an impinging jet of humid polluted air can provide a uniform and reproducible exposure of coupons of metal-based magnetic media. Numerical analysis of the fluid flow and mass transfer in such as system has shown that samples confined within a distance equal to the nozzle radius on the surface of impingement are uniformly accessible to pollutants in the impinging gas phase. The critical factor is the nozzle height above the surface of impingement. In particular, the uniformity of exposure is less than plus/minus 2% for a volumetric flow rate of 1600 cm(exp 3)/minute total flow with the following specifications: For a one inch nozzle, the height of the nozzle opening above the stage should be 0.177 inches; for a 2 inch nozzle - 0.390 inches. Not only is the distribution uniform, but one can calculate the maximum delivery rate of pollutants to the samples for comparison with the observed deterioration.

Sides, Paul J.↗

Observations and Lessons Learned from Testing of the Hanford Waste Treatment Plant Standard High Solids Vessel Design - 18635

The Hanford Waste Treatment and Immobilization Plant (WTP) recently completed qualification testing of the mixing system for the standard high solids vessel design the U.S. Department of Energy (DOE) proposed to replace several vessels in the design of the plant Pretreatment Facility. Testing was split into two phases. The first phase exercised the pulse jet mixer control system to ensure that the control software could accommodate fluids across the complete range of expected densities and viscosities within the vessel for all operational modes. The second phase of testing was focused on the mixing performance of the vessel, specifically, whether mixing was adequate to support the transfer, de-inventory, throughput, and sampling functions of the vessel. Key observations and lessons learned from testing include: - Successful transfer of waste within and beyond the design basis slurry solids concentration; - Successful resuspension and transfer of large, heavy particles; - Effective performance of multi-level bubblers for process control and monitoring; - Effective controls performance; - Reduction of sparger flowrate from nominal design flow; - Liquid blending within about 15 minutes; - Insights into sample representativeness and uniformity of transfers to inform process control strategies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

M-Area Mixed Waste Glasses: II: Durability and Viscosity Testing of High Aluminum and Uranium Containing Borosilicate Waste Glasses

Radioactive waste sludges that were high in A l2 O 3 (14.17 to 29.02 wt%) and U 3 O 8 (2.93 to 5.66 wt%) while being simultaneously low in Fe 2 O 3 (1.26 to 2.01 wt%) were vitrified into borosilicate glass in the Savannah River Site’s (SRS) M-Area. The overall Na 2 O concentrations of borosilicate and soda-lime-silica (SLS) glasses studied at the Savannah River National Laboratory (then the Savannah River Technology Center) prior to startup of the M-Area melter ranged from 6.80 to 27.09 wt%, while the B 2 O 3 concentrations ranged from 0.04 to 32.62 wt%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗