Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Mir Project”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

204 records · Page 12

Surface Radiation Budget (SRB) Release 2.5 Longwave 3 hourly Monthly Data in Native Format (SRB_REL2.5_LW_3HRLY_MONTHLY)

The surface radiation budget data include the averageupward and downward fluxes at three hourly intervals for the entire globe between 07/01/1983 and 06/30/2005. These parameters were derived using the Longwave algorithm of the NASA World Climate Research Programme/Global Energy and Water-Cycle Experiment (WCRP/GEWEX) Surface Radiation Budget (SRB) Project. [Location=GLOBAL] [Temporal_Coverage: Start_Date=1998-01-01; Stop_Date=2005-06-30] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=1 degree; Longitude_Resolution=Ranges from 1 degree (tropics and subtropics) to 120 degrees (the poles).; Temporal_Resolution=3 hourly values averaged monthly; Temporal_Resolution_Range=monthly].

OUTGOING LONGWAVE RADIATION

Radiation dosimetry measurements with real time radiation monitoring device (RRMD)-II in Space Shuttle STS-79

The real-time measurement of radiation environment was made with an improved real-time radiation monitoring device (RRMD)-II onboard Space Shuttle STS-79 (S/MM#4: 4th Shuttle MIR Mission, at an inclination angle of 51.6 degrees and an altitude of 250-400km) for 199 h during 17-25 September, 1996. The observation of the detector covered the linear energy transfer (LET) range of 3.5-6000 keV/micrometer. The Shuttle orbital profile in this mission was equivalent to that of the currently planned Space Station, and provided an opportunity to investigate variations in count rate and dose equivalent rate depending on altitude, longitude, and latitude in detail. Particle count rate and dose equivalent rate were mapped geographically during the mission. Based on the map of count rate, an analysis was made by dividing whole region into three regions: South Atlantic Anomaly (SAA) region, high latitude region and other regions. The averaged absorbed dose rate during the mission was 39.3 microGy/day for a LET range of 3.5-6000 keV/micrometer. The corresponding average dose equivalent rates during the mission are estimated to be 293 microSv/day with quality factors from International Commission on Radiological Protection (ICRP)-Pub. 60 and 270 microSv/day with quality factors from ICRP-Pub. 26. The effective quality factors for ICRP-Pub. 60 and 26 are 7.45 and 6.88, respectively. From the present data for particles of LET > 3.5keV/micrometer, we conclude that the average dose equivalent rate is dominated by the contribution of galactic cosmic ray (GCR) particles. The dose-detector depth dependence was also investigated.

manned

Surface Radiation Budget (SRB) Release 2 Shortwave Monthly Data in Native Format (SRB_REL2_SW_MONTHLY)

The SRB data include the average upward and downward fluxes, photosynthetically active radiative flux, aerosol and cloud optical depth, cloud fraction, and solar zenith angle at three hourly intervals for each day for the entire globe between 07/01/1983 and 10/31/1995. These parameters were derived with the Shortwave algorithm of the NASA World Climate Research Programme /Global Energy and Water-Cycle Experiment (WCRP/GEWEX) Surface Radiation Budget (SRB) Project. [Location=GLOBAL] [Temporal_Coverage: Start_Date=1983-07-01; Stop_Date=1998-07-26] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=1 degree; Longitude_Resolution=Ranges from 1 degree in the tropics to 120 degrees at the poles.; Temporal_Resolution=monthly; Temporal_Resolution_Range=monthly].

DIRECT/DIFFUSE SOLAR RADIATION

Preparing for Mars: the physiologic and medical challenges

As the twentieth century closes, retrospectives cite the Apollo moon missions as one of the important events of the past 100 years. A trip to Mars, however, would be even more challenging and significant. A round-trip Mars journey would require nearly three years away from Earth, a significant leap in complexity compared to the two week long Moon trips or the record-breaking fourteen-month flight on Mir. What would be the physiologic and medical challenges of a Mars flight? Two key areas of physiology present the greatest potential problems--calcium metabolism and radiation exposure. Data from Mir missions show that bone loss continues in space despite an aggressive countermeasure program. Average losses were 0.35% per month, but some load bearing areas lost >1% per month. A 1% loss rate, if it continued unabated for 30 months, could produce osteoporosis. Smaller losses could still increase fracture risk. Some bone loss can be well tolerated, particularly if the bone can be regained after the mission. But the effectiveness of post-flight rehabilitation to restore the density and quality of bone after spaceflight is not well known. Bone loss estimates are based on continuous weightlessness exposure, but this is not a requirement for a Mars trip. Most of the time on a Mars trip will be spent in the 1/3 Earth's gravity environment on Mars, and either intermittent or continuous artificial gravity can be provided for the transit between planets (although at an engineering cost). The dosing of the gravity exposure (e.g. the level and duration), however, has not been established. Radiation protection also requires a balance between engineering cost and human health. Excessive shielding could add billions of dollars to the cost of a mission. Trips in interplanetary space, however, expose the crew to heavy high-energy particles from cosmic rays (HZE particles), which have a high linear energy transfer. This high energy leads to significant biological damage (e.g. chromosomal aberrations, cancer induction). A recent report from the Committee on Space Biology and Medicine notes that only one systematic study of cancer induction from high-energy particles has been conducted (using the mouse Harderian gland). Predictions of cancer risk and acceptable radiation exposure in space are extrapolated from minimal data. Other areas of physiology also present problems, such as muscle loss, cardiovascular deconditioning, and vestibular adaptation. Despite all the issues, however, a focussed, aggressive research program that uses the resources of the International Space Station should pave the way for mankind's greatest adventure--a trip to Mars.

STS-90 Shuttle Project

In-flight radiation measurements on STS-60

A joint investigation between the United States and Russia to study the radiation environment inside the Space Shuttle flight STS-60 was carried out as part of the Shuttle-Mir Science Program (Phase 1). This is the first direct comparison of a number of different dosimetric measurement techniques between the two countries. STS-60 was launched on 3 February 1994 in a nearly circular 57 degrees x 353 km orbit with five U.S. astronauts and one Russian cosmonaut for 8.3 days. A variety of instruments provided crew radiation exposure, absorbed doses at fixed locations, neutron fluence and dose equivalent, linear energy transfer (LET) spectra of trapped and galactic cosmic radiation, and energy spectra and angular distribution of trapped protons. In general, there is good agreement between the U.S. and Russian measurements. The AP8 Min trapped proton model predicts an average of 1.8 times the measured absorbed dose. The average quality factor determined from measured lineal energy, y, spectra using a tissue equivalent proportional counter (TEPC), is in good agreement with that derived from the high temperature peak in the 6LiF thermoluminescent detectors (TLDs). The radiation exposure in the mid-deck locker from neutrons below 1 MeV was 2.53 +/- 1.33 microSv/day. The absorbed dose rates measured using a tissue equivalent proportional counter, were 171.1 +/- 0.4 and 127.4 +/- 0.4 microGy/day for trapped particles and galactic cosmic rays, respectively. The combined dose rate of 298.5 +/- 0.82 microGy/day is about a factor of 1.4 higher than that measured using TLDs. The westward longitude drift of the South Atlantic Anomaly (SAA) is estimated to be 0.22 +/- 0.02 degrees/y. We evaluated the effects of spacecraft attitudes on TEPC dose rates due to the highly anisotropic low-earth orbit proton environment. Changes in spacecraft attitude resulted in dose-rate variations by factors of up to 2 at the location of the TEPC.

NASA Discipline Radiation Health

Measurements of LET distribution and dose equivalent onboard the Space Shuttle IML-2 (STS-65) and S/MM#4 (STS-79)

Space radiation dosimetry measurements have been made onboard the Space Shuttle STS-65 in the Second International Microgravity Laboratory (IML-2: 28.5 degrees x 300 km: 14.68 days) and the STS-79 in the 4th Shuttle MIR mission (S/MM#4: 51.6 degrees x 300-400km: 10.2 days). In these measurements, three kinds of detectors were used; one is a newly developed active detector telescope called "Real-time Radiation Monitoring Device (RRMD-I for IML-2 and RRMD-II with improved triggering system for S/MM#4)" utilizing silicon semi-conductor detectors and the other detectors are conventional passive detectors of thermoluminescence dosimeters (TLDs) and CR-39 plastic track detectors. The main contribution to dose equivalent for particles with LET > 5.0 keV/micrometer (IML-2) and LET > 3.5 keV/micrometer (S/MM#4) is seen to be due to galactic cosmic rays (GCRs) and the contribution of the South Atlantic Anomaly (SAA) is less than 5% (IML-2: 28.5 degrees x 300 km) and 15% (S/MM#4: 51.6 degrees x 400 km) in the above RRMD LET detection conditions. For the whole LET range (> 0.2 kev/micrometer) obtained by TLDs and CR-39 in these two typical orbits (a small inclination x low altitude and a large inclination x high altitude), absorbed dose rates range from 94 to 114 microGy/day, dose equivalent rates from 186 to 207 microSv/day and average quality factors from 1.82 to 2.00 depending on the locations and directions of detectors inside the Spacelab at the highly protected IML-2 orbit (28.5 degrees x 300 km), and also, absorbed dose rates range from 290 to 367 microGy/day, dose equivalent rates from 582 to 651 microSv/day and average quality factors from 1.78 to 2.01 depending on the dosimeter packages around the RRMD-II "Detector Unit" at the S/MM#4 orbit (5l.6 degrees x 400km). In general, it is seen that absorbed doses depend on the orbit altitude (SAA trapped particles contribution dominant) and dose equivalents on the orbit inclination (GCR contribution dominant). The LET distributions obtained by two different types of active and passive detectors, RRMDs and CR-39, are in good agreement for LET of 15 - 200 kev/micrometer and difference of these distributions in the regions of LET < 15 kev/micrometer and LET > 200 kev/micrometer can be explained by considering characteristics of CR-39 etched track formation especially for the low LET tracks and chemical etching conditions.

manned