Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microfluidics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Kinetics and Mechanism of Tetravalent Cerium Extraction by Di-2-Ethylhexyl Isobutyramide (DEHiBA)

DEHiBA is a fully-incinerable, CHON extractant with a high selectivity for hexavalent actinides. However, as a recently-developed ligand, much remains unknown about its physical and chemical properties, including its extraction and phase disengagement rates. Here, we present data on the phase transfer kinetics of Ce(IV) extraction and stripping by both DEHiBA and TBP collected using microfluidic devices. Ce(IV) was selected as a surrogate for Pu(IV) and Np(IV) in the initial tests of the microfluidics system prior to testing with the actinides. Pseudo first-order reaction rate constants are determined for both systems, and the corresponding Damköhler numbers (Da) are calculated to establish whether the extraction and stripping processes are kinetically or diffusion controlled. The stoichiometry of the extracted Ce(IV)-DEHiBA complex is determined, and the phase disengagement properties under extraction conditions are assessed using the dimensionless dispersion number. A possible explanation for the favorable extraction of Ce(IV) by DEHiBA, which is known to poorly extract many tetravalent cations, is presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Out of the Lab: 3D Printing on Non-Ideal Surfaces

In this work, coaxial direct ink writing is utilized to print sensitive or encapsulated materials onto heterogeneous and rough substrates. By enclosing the core fluid within a rigid ceramic shell, continuity is maintained even when printing on substrates traditionally considered challenging. This work presents the development of a coaxial ceramic direct ink writing system and investigates co-flow dynamics through microfluidic principles. A specially designed coaxial nozzle enables the co-extrusion of an alumina shell, with indium-tin-oxide inks serving as the core material. This approach allows the fabrication of core-shell ceramic structures suitable for future high-temperature applications on rough surfaces. The colloidal inks are tailored to achieve the necessary rheological properties and sintering performance. Additionally, flow simulations, guided by microfluidic co-flow principles, are employed to define the processing parameters for coaxial printing, ensuring precise control over the core-shell architectures. Physical modeling is further applied to study core deformation and eccentricity. These simulations are experimentally validated, supporting the successful deposition of coaxial ceramic features on heterogeneous, high-temperature ceramic substrates.

20 FOSSIL-FUELED POWER PLANTS↗

Evaluating Polymer Properties with Different Additives for Carbon Capture and Other Applications

Anthropogenic climate change is one of this generation’s most pressing concerns, with the potential to completely alter the delicate balance we’ve struck with nature. Already, global temperatures have risen 1.29°C, leading to disrupted weather systems, extinctions, increased risks of wildfires, and sea level rise, to name a few effects. Carbon dioxide emission from the combustion of fossil fuels and other industrial activity is a large driver of this phenomenon, as it absorbs heat before it can be radiated away from Earth, trapping it. Carbon dioxide has reached unprecedented levels in our atmosphere, showing a 50% increase from preindustrial averages to a whopping 430 ppm. Thus, reducing the amount of carbon dioxide via carbon capture technology is an important endeavor that serves to benefit everyone. The Microencapsulated CO 2 Sorbent (MECS) team at Lawrence Livermore National Laboratory (LLNL) has turned to microencapsulation to approach this endeavor. Microcapsules provide an attractive approach to carbon capture, combining large surface areas for more efficient mass transfer, regenerative abilities, reduced solvent loss, and improved handling. Additionally, while existing carbon capture technology relies on industrial plants, capsules could present a modular approach to carbon capture, reducing the need for extensive physical infrastructure. The MECS team’s design consists of a polymer membrane that contains a liquid carbon sequestering sorbent, aqueous sodium carbonate. The carbon capturing reaction occurs in three distinct steps, the first of which is the dissolution of carbon dioxide into the sorbent solution and its conversion into carbonic acid (H 2 CO 3 ), shown in equations 1 and 2 respectively. Because this step hinges upon the ability of carbon dioxide to reach the solution inside the capsule, it is necessary that the microcapsule shell is permeable to carbon dioxide gas. The MECS team produces these microcapsules using the in-air droplet encapsulation apparatus (IDEA) shown in figure 1, which can produce uniform micron-scale droplets at speeds much faster than traditional single-dispersal microfluidic-based techniques. The IDEA Is 100 times faster than these current techniques and can reach up to 1000 times their speed when incorporating a multi-nozzle design. Additionally, because droplets are produced in-air via vibration, IDEA can decrease post-processing times and material waste by 99% and can fabricate microgels that are 10 to 100 times more viscous than can be produced via traditional microfluidics. While this design represents a breakthrough in the throughput, efficiency, and tunability of microcapsule production, it imposes a major constraint on the microcapsule curing process. Because microcapsule shells are crosslinked with UV light while falling 30 cm through the air, this gives them a reaction window of approximately 0.2 seconds. Thus, the system and shell formulations must be optimized such that the shells can be fully crosslinked within this very narrow window, prompting investigations into curing behavior.

36 MATERIALS SCIENCE↗

Reducing the matrix effect in mass spectral imaging of biofilms using flow-cell culture

The interactions between soil microorganisms and soil minerals play a crucial role in the formation and evolution of minerals and the stability of soil aggregates. Due to the heterogeneity and diversity of the soil environment, the under-standing of the functions of bacterial biofilms in soil minerals at the microscale is limited. A soil mineral-bacterial biofilm system was used as a model in this study, and it was analyzed by time-of-flight secondary ion mass spectrometry (ToF-SIMS) to acquire molecular level information. Static culture in multi-wells and dynamic flow-cell culture in microfluidics of biofilms were investigated. Our results show that more characteristic molecules of biofilms can be observed in SIMS spectra of the flow-cell culture. In contrast, biofilm signature peaks are buried under the mineral components in SIMS spectra in the static culture case. Spectral overlay was used in peak selection prior to performing Principal component analysis (PCA). Comparisons of the PCA results between the static and flow-cell culture show more pronounced molecular features and higher loadings of organic peaks of the dynamic cultured specimens. For example, fatty acids secreted from bacterial biofilm extracellular polymeric substance are likely to be responsible for biofilm dispersal due to mineral treatment up to 48 h. Such findings suggest that the use of microfluidic cells to dynamically culture biofilms be a more suitable method for reducing the matrix effect arisen from the growth medium and minerals as a perturbation fac-tor for improved spectral and multivariate analysis of complex mass spectral data in ToF-SIMS. These results show that the interaction mechanism between biofilms and soil minerals at the molecular level can be better studied using the flow-cell culture and advanced mass spectral imaging techniques like ToF-SIMS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flow-regulated growth of nanotubes

A method for growing nanotubes via flow-regulated microfluidic electrochemical anodization, includes providing a microfluidic device having a fluid inlet; a fluid outlet; and a fluidic microchannel connecting the fluid inlet and outlet, wherein the microchannel includes a Pt cathode and a Ti anode separated by an electrical insulator; providing an electrolyte fluid flow through the microchannel; and providing an electrical current across the anode and cathode sufficient to cause electrochemical anodization growth of TiO2 nanotubes in the microchannel on a surface of the anode.

Wan, Jiandi↗

Volumetric micro-injector for capillary electrophoresis

A volumetric microfluidic injector for capillary electrophoresis (CE) for highly repeatable sample injection has been designed and built to eliminate known injection bias in hydrodynamic injection. A defined volume from 1-10 nL or 0.1-100 nL of sample is confined in a defined region of a micro-valve PDMS microfluidic injector chip and electrophoretic potential is applied to drive sample into a separation device such as an embedded fused silica capillary for separation and detection. Using a 75 μm ID capillary, the RSD of an absorbance peak area as low as 1.32% (n=11) is obtained. As a comparison, the time-dependent injection was tested using the same chip which resulted in an inferior repeatability.

Ha, Noel Seunghyun↗

Liquid Interfacial Electron Microscopy Identifies Nanogalvanic Corrosion in Pearlitic Steel

The nanoscale mechanisms of localized corrosion in low carbon steels have remained elusive due to the complexity of studying the degradative material behavior at nanoscale solid-liquid interfaces. We identified various steps in the nanogalvanic corrosion processes using in-situ liquid-cell scanning transmission electron microscopy (STEM) using a microfluidic holder by Hummingbird Scientific. Initial work, performed at low magnification, identified the initiation point on a 1018 low-carbon steel surface. This initiation point was determined to be a triple junction of two ferrite grains bridging a cementite grain in contact with a baseline electrolyte of 6 uM CO2 dissolved in a buffered (2.78 uM Na2SO4) aqueous solution, pH 6.1. The pre-etched low-carbon steel surface was prepared using focused ion beam lift-out procedures to extract a cross-section of the low-carbon steel surface, which then was thinned to about 150 nm and transferred to a SiN membrane microfluidic window. The transfer was made using a lift-out needle to attach the low-carbon steel lamella to the corner of the SiN window, and then Pt/C deposition held the lamella in contact with the window while it was released from the lift out needle. To identify the triple point on the low carbon steel lamella, prior to attachment on the SiN window, the sample was characterized for compositional variations with energy dispersive x-ray spectroscopy mapping, grain orientation and phase mapping with precession electron diffraction, and thickness mapping with energy filtered transmission electron microscopy. This pre-characterization prior to the in-situ experiment provided a map of the multiphase and multigrain structure, where the in-situ liquid cell imaging provided a clear understanding of the initiation point on the sample. These data were cross-correlated to paint a holistic picture of the triple junction site, enabling low electron-fluence in-situ snapshot imaging to avoid dominating the native corrosion reactions with effects from the incident electron beam. This initial result identified that localized, nanogalvanic corrosion at the phase interface was the dominant corrosion process in the low-carbon steel, so we next targeted the observation of an array of these nanogalvanic features phase boundaries in a pearlite grain. Near-surface ferrite/cementite phase interfaces that typify pearlitic low-carbon steel were extracted, pre-characterized, and imaged for the in-situ corrosion processes. The sample was a cross-section from a pearlite grain, with alternating ferrite and cementite grains that extended microns down from the pre-etched low-carbon steel pipe surface. After contact with a buffered aqueous solution, the phase boundaries between the ferrite and cementite began to dissolve, with observable material loss and thickness changes in the dark-field and bright-field STEM images. Within minutes, the corrosion front proceeded deeper into the material, claiming a thin layer of ferrite around all exposed phase boundaries before progressing laterally into the ferrite matrix, converting the ferrite to corrosion product normal to each buried cementite grain. Formation of the corrosion product causes a volumetric expansion, creating a lateral wedging force that mechanically ejects the cementite grains from their grooves and leaves behind percolation channels into the steel substructure. Rapid and deleterious, this nanogalvanic corrosion pathway represents an important target for understanding and preventing run-away degradation in this common building material. Observation of this corrosion mechanism was enabled by the combination of pre-characterization using standard structural, grain, and compositional analysis in the TEM, which provides maps for understanding the reaction propagation captured in low-dose, in-situ, liquid-cell STEM.

corrosion↗

Multimodal imaging of oil-in-water bilgewater emulsion and biofilms

Bilgewater emulsions, consisting of oil and surfactant mixtures in water, affect many aquatic species. Thus development of methods and techniques to treat or mitigate the formation and undesired consequences of shipboard emulsions are urgently needed. This work presents new results of the evolution of the bilgewaer chemical and physical properties using in situ imaging. A Navy O/W emulsion consisting of three oils and a detergent mixture was used as the synthetic bilgewater model [1, 2]. Synthetic oil-in-water (O/W) emulsion droplets were seled in a vacuum compatible microfluidic sample holder and imaged using a suite of tools including scanning electron microscopy (SEM), time-of-flight secondary ion mass spectrometry (ToF-SIMS), confocal laser scanning microscopy, and optical microscopy, highlighting the advantage of multiscale analysis and its applications in waste reduction and treatment in the environment. The transferrable and vacuum compatible microfluidic interface, System for Analysis at the Liquid Vacuum Interface (SALVI), was used in this study. SALVI enabled surface analysis of liquids and liquid-solid interactions using ToF-SIMS and SEM [3, 4]. Its detection window is an aperture of 2 ?m in diameter open to vacuum, permitting direct detection of the liquid surface. Liquid is withheld by surface tension within the aperture. The interface is composed of a silicon nitride membrane and polydimethylsiloxane microchannel [3, 4]. A variety of samples including complex liquid mixtures, ionic liquids, single mammalian cells, live biofilms, and solid-electrolyte interface have been analyzed using in situ imaging [5, 6]. The feasibility of using SALVI for in situ SEM imaging of nanoparticles and colloids in liquid was recently demonstrated [7]. This paper shows new findings of multimodal imaging and analysis of synthesized emulsion particles in water. Figure 1 depicts a schematic of multimodal in situ imaging of bilgewater emulsion using SEM and ToF-SIMS. Furthermore, we study the interactions of microbes and bilgewater emulsion. Microbes play an important role in the ocean. We hypothesize that microbes release organics that can act as surfactants that affect bilgewater formation or weakening. We present the first systematic study of emulsions and biofilms and investigate the effects of biofilms on bilgewater emulsions. Pseudomonas was selected as a model strain. Biofilms were cultured in a microchannel to allow culture [8]. Once a thick layer of biofilms was formed, the medium solution was changed to a mixture consisting of 50 % bilgewater emulsion. Dispersed biofilms were collected at 24 hrs. and 48 hrs. after emulsions were introduced into the channel. Bilgewater emulsions, biofilms, and mixtures of bilgewater emulsions and biofilms were analyzed using multiple in situ and ex situ techniques as described earlier. Our findings indicate that biofilms change the chemical makeup of the emulsion surface compositions and emulsion droplet size distribution, confirming the hypothesis that extracellular polymeric substance (EPS) related components released from biofilms can function as surfactants and change the oil-in-water interfaces.

bilgewater, multimodal imaging, biofilms↗

Self-Driving Microscopy for AI/ML-Enabled Physics Discovery and Materials Optimization

Materials are the bedrock of economy and foundation for all real-world technologies. The viability of space travel, grid energy storage, solar to fuels conversion, methane removal, and photovoltaic energy solutions hinge on the discovery and optimization of novel materials and rapid scaling toward manufacturing. The last 20 years have seen an exponential growth in the theoretical predictive capability for crystalline materials and small molecules. However, it is only in the last five years that we have seen the rapid expansion of high-throughput synthesis enabled by laboratory robotics and microfluidics, as well as a resurgence of combinatorial synthesis (Abolhasani and Kumacheva 2023; Epps and Abolhasani 2021; Jiang et al. 2022; Rajan 2008; Soldatov et al. 2021; Szymanski et al. 2023). Combinatorial synthesis, microfluidics, and ultimately dip-pen megalibraries have demonstrated the ability to “write” multicomponent nanomaterials at high throughput scale, generating millions of material examples in the 3D, 4D, and 5D composition spaces (Chen et al. 2016, 2019; Jibril et al. 2022).

36 MATERIALS SCIENCE↗

Module-Fluidics: Building Blocks for Spatio-Temporal Microenvironment Control

Generating the desired solute concentration signal in micro-environments is vital to many applications ranging from micromixing to analyzing cellular response to a dynamic microenvironment. We propose a new modular design to generate targeted temporally varying concentration signals in microfluidic systems while minimizing perturbations to the flow field. The modularized design, here referred to as module-fluidics, similar in principle to interlocking toy bricks, is constructed from a combination of two building blocks and allows one to achieve versatility and flexibility in dynamically controlling input concentration. The building blocks are an oscillator and an integrator, and their combination enables the creation of controlled and complex concentration signals, with different user-defined time-scales. We show two basic connection patterns, in-series and in-parallel, to test the generation, integration, sampling and superposition of temporally-varying signals. All such signals can be fully characterized by analytic functions, in analogy with electric circuits, and allow one to perform design and optimization before fabrication. Such modularization offers a versatile and promising platform that allows one to create highly customizable time-dependent concentration inputs which can be targeted to the specific application of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated Label‐Free Assay for Viral Detection and Inhibitor Screening via Biomembrane‐Functionalized Microelectrode Arrays

Most virus infection assays have indirect readout such as virus number following entry (e.g., PCR, cell lysis). While effective, these technologies are labor‐intensive, require specialized environments (e.g., sterile or RNA‐free), and detect later‐stage viral events like lysis or cell death, lacking sensitivity to early fusion events. To address these limitations, we present biologically relevant 2D membrane materials, host‐cell‐derived supported lipid bilayers (hcd‐SLBs), integrated with organic microelectrode arrays (OMEAs) for detection of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) fusion. By overexpressing angiotensin‐converting enzyme 2 (ACE2) receptors on the native membranes, the platform functions as a viral sensor capable of detecting virus pseudo particles (VPPs) through the late pathway. Additionally, hcd‐SLBs extracted from human lung epithelium expressing native ACE2 detect fusion events through the early pathway. The platform's utility as a drug‐screening tool is demonstrated by testing antibodies targeting either the ACE2 on the host membrane or the viral spike (S) proteins. To enhance the throughput, microfluidics are integrated for automation and OMEAs are incorporated within each channel, miniaturizing the testing units. This system supports high‐throughput data generation, automation, and scalability, providing an efficient platform for viral fusion detection that advances the study of pathogen‐host interactions and accelerates antiviral drug discovery.

Biology↗

Current–Induced Ion Concentration Polarization at a Perfect Ion–Exchange Patch in an Infinite Insulating Wall

This research examines theoretically the ion concentration polarization, ion fluxes, and electrostatic fields near an ion exchange patch in the wall of an electrified fluidic channel. These phenomena are important in related microfluidic ion-preconcentration systems. Under an electric field, counterions enter the ion-exchange patch at one side and leave at the other, with salt depletion occurring near the entrance and accumulation near the exit. Furthermore, the high patch conductivity and the concentration profiles lead to local electric field perturbations that may facilitate preconcentration. This study includes analytical expressions of ion concentrations and electrochemical potentials at small to moderate electric fields, as well as numerical simulations. Additionally, a simple matrix of polynomial coefficients (obtained via fitting of numerical data) enables analytical calculation of the 2-dimensional concentration profiles at all electric fields within the range investigated in the numerical simulations. This is possible because a single dimensionless parameter controls this problem.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cation-Specific Electrokinetic Separations Using Prussian Blue Intercalation Reactions

In this work, we report a new approach for forming ion depletion zones (IDZs) using intercalation reactions at an electrochemically controlled Prussian blue (PB) film. The experiments described here were performed using a microfluidic device, wherein a charged fluorophore in solution was used as a proxy to monitor IDZ formation. In the presence of K + , intercalation reactions proceed readily to form an IDZ, and thus enrich the fluorophore up to 37-fold. In the presence of the larger hydrated Li + or tetrabutylammonium (TBA + ) ions, however, ion intercalation proceeded less quickly than with K + . Slower ion intercalation resulted in a weaker IDZ and correspondingly lower enrichment factors of eight- and six-fold, respectively. These results are significant because they show that PB intercalation reactions selectively form an IDZ. Accordingly, we anticipate that these findings will lead to a better understanding and further interesting applications of intercalation materials like PB for efficient and selective enrichment and separations.

99 GENERAL AND MISCELLANEOUS↗

Enriching Cations Using Electric Field Gradients Generated by Bipolar Electrodes in the Absence of Buffer

We discuss that ionic current gradients and corresponding electric field gradients formed at bipolar electrodes are useful for enriching cations up to ~350-fold at specific locations in microfluidic devices. The enrichment mechanism is determined by collecting current data, measuring solution conductivity, and by performing pH indicator experiments. These data reveal the dynamic nature of the enrichment mechanism. Specifically, they show the complex relationship between the ionic current gradients formed at the bipolar electrode and the extent of cation enrichment. Finally, we demonstrate cation enrichment is possible in buffer-free solutions containing up to 50.0 mM KCl. This finding is significant because it broadens the range of solutions in which membrane-free, electrochemical separations using bipolar electrodes can be performed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating inkjet dispenser/liquid vortex capture-mass spectrometry for single-cell metabolomics in Hep G2 steatosis caused by tamoxifen

Single-cell mass spectrometry (MS) is advancing our understanding of metabolic pathways in heterogeneous cell populations; however, many techniques are slow or require disruptive sample preparations. This study evaluated coupling a modified HP D100 single-cell inkjet dispenser with liquid vortex capture-mass spectrometry (D100/LVC-MS). The D100 is a single-cell inkjet dispenser capable of titrating solutions and isolating single cells via disposable cassettes equipped with microfluidic channels and an impedance sensor. The LVC-MS enables high-throughput capture, lysis, and ionization of analytes for mass spectrometric analysis. The D100/LVC-MS system was characterized through titration and single-cell experiments. Propranolol titration demonstrated linearity across a broad concentration range using the D100/LVC-MS system. Additionally, Hep G2 hepatocarcinoma cells and Chlamydomonas reinhardtii algae were used to showcase the D100’s high-throughput or low-buffer-volume single-cell dispensing strategies. The D100/LVC-MS system’s performance was validated by evaluating tamoxifen-induced steatosis in Hep G2 cells. Tamoxifen, associated with nonalcoholic fatty liver disease in breast cancer patients following long-term use, was tested in Hep G2 cells at 20 µM for 72 h against DMSO-treated controls. High-throughput analysis of 500 cells per condition, completed in 25 min per run, demonstrated the system’s efficiency. The D100/LVC-MS system simultaneously quantified tamoxifen and measured triglycerides and phosphatidylcholines. Triglycerides were upregulated in the tamoxifen-treated cells and the results indicated two distinct cell populations, differing in tamoxifen and phosphatidylcholines levels, suggesting heterogeneity within the treated population. In conclusion, these findings highlight the D100/LVC-MS system as a cost-effective, high-throughput platform for single-cell metabolomics and lipidomics, with significant potential for evaluating metabolic alterations.

Chromatography↗

On the competition between mixing rate and uniformity in a coaxial hydrodynamic focusing mixer

Fast microfluidic mixers for use with line-of-sight integrating detection schemes pose unique challenges. Such detectors typically cannot discriminate signal from slow moving (e.g. near internal walls) and fast-moving portions of the fluid stream. This convolves reaction rate dynamics with fluid flow residence time dynamics. Further, the small cross sections of typical three-dimensional hydrodynamic focusing devices lead to lower detection signals. The current study focuses on achieving both small time scales of mixing and homogenous residence times. This is achieved by injecting sample through a center capillary and hydrodynamically focusing using a sheath flow within a tapered second capillary. The current design also features a third, larger coaxial capillary. The mixed stream flows into the large cross-section of this third capillary to decelerate and expand the stream by up to 14-fold to improve line-of-sight signal strength of reaction products. Hydrodynamic focusing, mixing, and expansion are studied using analytical and numerical models and also studied experimentally using a fluorescein-iodide quenching reaction. The experimentally validated models are used to explore trade-offs between mixing rate and uniformity. For the first time, this work presents detailed analysis of the Lagrangian time history of species transport during mixing inside coaxial capillaries to measure mixing nonuniformity. The mixing region enables order 100 μs mixing times and residence time widths of the same order (140 μs).

42 ENGINEERING↗

Coupling between DNA replication, segregation, and the onset of constriction in Escherichia coli

Escherichia coli cell cycle features two critical cell-cycle checkpoints: initiation of replication and the onset of constriction. While the initiation of DNA replication has been extensively studied, it is less clear what triggers the onset of constriction and when exactly it occurs during the cell cycle. Here, using high-throughput fluorescence microscopy in microfluidic devices, we determine the timing for the onset of constriction relative to the replication cycle in different growth rates. Our single-cell data and modeling indicate that the initiation of constriction is coupled to replication-related processes in slow growth conditions. Furthermore, our data suggest that this coupling involves the mid-cell chromosome blocking the onset of constriction via some form of nucleoid occlusion occurring independently of SlmA and the Ter linkage proteins. This work highlights the coupling between replication and division cycles and brings up a new nucleoid mediated control mechanism in E. coli.

59 BASIC BIOLOGICAL SCIENCES↗

Insight into industrial hemp ( Cannabis sativa L.) root exudation composition in a simulated soil environment: a rhizosphere-on-a-chip study

Microfluidic technologies provide a reduced complexity and soil-free environment to study plant-soil interactions at the microscale. Traditionally used for model plants such as Arabidopsis thaliana, this study represents the first application of a rhizosphere-on-a-chip (RhizoChip) to investigate root exudation in industrial hemp (Cannabis sativa L.), an agronomic crop with growing economic importance. By incorporating soil-like minerals (kaolinite, potassium feldspar, and biotite), the RhizoChip addresses limitations of previous research. Hemp seedlings grown in mineral-containing chips exhibited significant root growth, emphasizing the critical role of minerals in root development. Using untargeted metabolomics, 170 compounds were identified, including organic acids, amino acids, and secondary metabolites, with distinct profiles across conditions. Metabolic pathway analysis revealed activity in amino acid metabolism, the citric acid cycle, and secondary metabolite biosynthesis. In conclusion, this study highlights the RhizoChip's potential for long-term studies of root exudates in non-model crops and offers insights into rhizosphere processes with implications for sustainable agriculture.

59 BASIC BIOLOGICAL SCIENCES↗