Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Membrane systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Wave

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wave energy conversion device. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen. While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the wave energy, NLR used a wave energy converter model from PacWave. These devices can be equipped with accumulators and pressure relief values to smooth the power output by storing and releasing hydraulic energy. Using a peak power output of 10 MW, the model created two 25-minute profiles: one with and one without the accumulators and pressure relief valves. To down select the profile data from the native resolution of 20 Hz to 1 Hz, NLR took the mean of every 20 data points. NLR experimented with two simulated wave energy power plants: one that peaks at 10 MW, and one that peaks at 5 MW. These profiles were scaled for the physical 1.25 MW electrolyzer by multiplying the original profiles by one eighth and one quarter, respectively. The first profile matches the capacity rating of eight of the 1.25 MW electrolyzers, while the second matches four electrolyzers. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wave electrolysis experiment and is formatted as follows: {technology}-{accumulator?}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “wavePacWave-Noacc_4-400.zip” represents the 25 minute-long experiment using the PacWave’s wave energy converter model, equipped with no accumulator, connected to four 1.25-MW electrolyzers with their power supplies set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. An experiment, labeled “characterization_200.zip”, demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all wave profiles combined into one dataset labeled "combined_wave_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis.

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

Scaling dynamics in low-salt-rejection reverse osmosis for high-salinity produced water desalination: Mechanistic modeling and membrane autopsy

Membrane scaling remains a critical barrier to the reliable operation of desalination systems, particularly for hypersaline produced water (PW) treatment. This study fills the knowledge gap of autopsy-based model validation for PW desalination by elucidating scaling mechanisms in a Low-Salt-Rejection Reverse Osmosis (LSRRO) system through the integration of pilot-scale experimentation and complementary modeling approaches. A semi-empirical modeling framework was developed and applied to a multistage pilot LSRRO system equipped with nanofiltration and RO membranes treating high-salinity PW from the Permian Basin. Water quality analysis showed that total dissolved solids decreased from ~130,000 mg/L to ~1900 mg/L in the permeate, then further reduced to ~300 mg/L by a second-pass RO. Two different thermodynamic modeling approaches were evaluated: the first extends the LSRRO framework by incorporating system complexity and scaling phenomena, whereas the second method explicitly captures concentration polarization in localized supersaturation. Both methods illustrate the tendency for carbonate and sulfate scaling throughout the stages. Membrane autopsies revealed a silica-dominated deposit matrix, localized CaSO 4 at Stage 2, and minor barite/celestite despite their prominence in model predictions. Quantum-chemical calculations indicated silica scaling can be rationalized by favorable adsorption of H 4 SiO 4 on Fe-oxide surfaces (ΔG ≈ −44 kJ/mol), providing a kinetic pathway for interfacial inorganic polymerization even when bulk equilibrium predictions are conservative. Overall, the thermodynamic scaling modeling and membrane autopsy revealed heterogeneous, localized deposits with limited impact on LSRRO performance, while quantum analysis rationalized the thermodynamically unfavorable precipitation formation under bulk equilibrium, reconciling model–autopsy discrepancies. These insights support targeted pretreatment and silica-specific antiscalants to extend membrane lifetime and increase recovery, providing a transferable framework for hypersaline water desalination systems. The combined experimental–computational approach provides new mechanistic insight into scaling in hypersaline membrane systems and establishes a transferable framework for predicting and mitigating scaling in next-generation desalination technologies.

Low-salt-rejection reverse osmosis↗

Understanding and Manipulating Counterion Condensation within Charged Polymer Electrolytes for Selective and Low Resistant Membrane Separations

Polymeric ion-exchange membranes are found at the heart of numerous electrochemical systems spanning separations (electrodialysis and membrane capacitive deionization) and energy conversion and storage (flow batteries, fuel cells, and electrolyzers). The ion-exchange membrane separators need to be ion conducting but electron insulating, and in many scenarios selective for a particular ion to conduct. Because of their polymeric nature, the molecular architectures of ion-exchange membranes lack the molecular precision found in many inorganic materials. Plus, they contain numerous structural defects that impede ionic transport. As a result of their poor structure, it has been difficult to carefully probe the underlying physics that governs ion transport in ion-exchange membranes. We investigated counterion condensation phenomena in ion-exchange membranes and correlated it to bulk ionic charge transport and selectivity in precisely defined and long-range ordered materials afforded through the principles of directed self-assembly. A multi-faceted approach spanning i.) advanced metrology, two-dimensional atomic force microscopy, x-ray scattering, and ion-exchange equilibria, and ii.) molecular simulations (classical molecular dynamics and ab-inito molecular dynamics) that bridge multiple time and length scales, were employed to correlate the extent of counterion condensation to ionic conductivity and selectivity. After uncovering the extent of the condensation phenomena in this project, new macromolecular chemistries were employed to manipulate the ion pairing interactions of the condensed counterions to tethered ions on the polymer backbone so more facile and selective conduction rates can be attained. The research has aided in the rational design of polymeric ion-exchange membrane separators with high current density for electrochemical systems and subsequently better energy efficiency.

36 MATERIALS SCIENCE↗

Bench-Scale Development of a Hybrid Membrane-Absorption CO 2 Capture Process

This final technical report describes work conducted for the Department of Energy (DOE) on the development of a bench-scale hybrid membrane-absorption carbon dioxide (CO 2 ) capture system for coal-fired power plant applications (Cooperative Agreement number DE-FE0013118). The work was conducted by Membrane Technology and Research, Inc. (MTR) with major support from the University of Texas at Austin (UT Austin) from April 1, 2013 through September 30, 2018. The overall goal of this project was to evaluate two variations of a hybrid membrane-absorption capture system combining the MTR air-swept Polaris TM membrane technology, which enriches flue gas to ~20% CO 2 , with UT Austin’s absorption-based advanced flash stripper (AFS) using piperazine (PZ), to determine the superior hybrid variant and to assess the potential of hybrid capture systems to achieve a lower cost-of-capture, compared to NETL’s reference amine-based capture plant. This project included the evaluation, development and testing of a hybrid membrane-absorption CO 2 capture system for coal-fired power plant applications using the MTR high-gas-flow, lowpressure- drop membrane contactor. The ability of the membrane contactor to enrich coal-fired flue gas from its normal content of ~13% CO 2 into a smaller volume of gas containing 20-25% CO 2 – with minimal energy input – could reduce the cost of the final concentration process, regardless of whether it is absorption, adsorption, cryogenic, or membrane-based. In this project, we are evaluating the feasibility of a hybrid system combining the MTR sweep membrane technology with the UT Austin piperazine-based advanced flash stripper (PZAS) capture system.

99 GENERAL AND MISCELLANEOUS↗

Recent developments in Pt–Co catalysts for proton-exchange membrane fuel cells

Development of Pt-based oxygen reduction reaction catalysts with high efficiency and high durability is central to the application of proton-exchange membrane fuel cell systems. Pt–Co bimetallic catalysts have drawn extensive attention owing to their capability of delivering high performance and long lifetime for fuel cell applications including light-duty and heavy-duty vehicles. However, further improvements in durability and performance are needed to meet market requirements. To fully exploit the potential of Pt–Co catalysts, new insights into the relationship between catalyst properties and fuel cell performance and durability are needed, and more effective methods to tailor the features of Pt–Co catalysts need to be developed. This review provides a summary and perspective on recent efforts, including work on customizing the Pt shell and Pt:Co ratio, tailoring the crystal structure, and improving carbon support properties, with a particular emphasis on mechanisms leading to enhancement of mass activity, power density, and durability in membrane electrode assembly testing.

25 ENERGY STORAGE↗

Multi-lab study on the pure-gas permeation of commercial polysulfone (PSf) membranes: Measurement standards and best practices

Gas-separation membranes are a critical industrial component for a low-carbon and energy-efficient future. As a result, many researchers have been testing membrane materials over the past several decades. Unfortunately, almost all membrane-based testing systems are home-built, and there are no widely accepted material standards or testing protocols in the literature, making it challenging to accurately compare experimental results. Further, in this multi-lab study, ten independent laboratories collected high-pressure pure-gas permeation data for H 2 , O 2 , CH 4 , and N 2 in commercial polysulfone (PSf) films. Equipment information, testing procedures, and permeation data from all labs were collected to provide (1) accepted H 2 , O 2 , CH 4 , and N 2 permeability values at 35°C in PSf as a reference standard, (2) statistical analysis of lab-to-lab uncertainties in evaluating permeability, and (3) a list of best practices for sample preparation, equipment set-up, and permeation testing using constant-volume variable-pressure apparatuses. Results summarized in this work provide a reference standard and recommended testing protocols for pure-gas testing of membrane materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structure of a tripartite protein complex that targets toxins to the type VII secretion system

Type VII secretion systems are membrane-embedded nanomachines used by Gram-positive bacteria to export effector proteins from the cytoplasm to the extracellular environment. Many of these effectors are polymorphic toxins comprised of an N-terminal Leu-x-Gly (LXG) domain of unknown function and a C-terminal toxin domain that inhibits the growth of bacterial competitors. In recent work, it was shown that LXG effectors require two cognate Lap proteins for T7SS-dependent export. Here, we present the 2.6 Å structure of the LXG domain of the TelA toxin from the opportunistic pathogen Streptococcus intermedius in complex with both of its cognate Lap targeting factors. The structure reveals an elongated α-helical bundle within which each Lap protein makes extensive hydrophobic contacts with either end of the LXG domain. Remarkably, despite low overall sequence identity, we identify striking structural similarity between our LXG complex and PE–PPE heterodimers exported by the distantly related ESX type VII secretion systems of Mycobacteria implying a conserved mechanism of effector export among diverse Gram-positive bacteria. Overall, our findings demonstrate that LXG domains, in conjunction with their cognate Lap targeting factors, represent a tripartite secretion signal for a widespread family of T7SS toxins.

59 BASIC BIOLOGICAL SCIENCES↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Marine Hydrokinetic Tidal Turbine

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset is part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with other energy technologies. This dataset contains inputs and outputs from simulations of a floating marine hydrokinetic turbine over approximately half a tidal cycle (~6.6 hours). Inflow conditions were derived from field measurements in Alaska’s Cook Inlet and represent a tidal environment in which the current speed ramps from near 0 m/s to a peak of 3 m/s and back. The original acoustic doppler current profiler dataset is publicly available on the Marine and Hydrokinetic Data Repository. In a full tidal cycle, the flow reverses and the rotor would reorient; this reversal was not modeled. In the Cook Inlet campaign , turbulence intensity was similar in both directions. Two inflow cases are included. In the first case, labeled “raw” in the files, the measured current time series was used directly in the InflowWind module of OpenFAST. Speed and direction were applied as a function of time and elevation, uniformly in the horizontal direction. With full spatial coherence, this approach captures high turbulent variability and results in pronounced power fluctuations, so it is considered a conservative, near-worst-case representation of loading. In the second case, labeled “average” in the files, a 30-minute moving average was applied to extract the slowly varying mean speed. The residual fluctuations about this mean were used to generate spatially varying, full-field turbulence inputs with TurbSim, giving a more physically realistic representation of the inflow across the rotor disk. Two random realizations were used to produce distinct inflow conditions for two OpenFAST simulations representing a two-turbine array. The same turbulence intensity is applied across the full time series, producing larger fluctuations at the start and end, where the mean speed is low. The second case is the more appropriate framework for performance and power assessment but overpredicts turbulence at lower flow speeds and underpredicts it at higher speeds. As the floating platform moves and the rotor changes its x-position, Taylor’s frozen turbulence hypothesis used by InflowWind assumes a constant rather than a time-varying mean velocity, introducing some inaccuracy in the velocity plane sampling. The turbine modeled is the 500-kW Reference Model 1, a horizontal-axis two-bladed hydrokinetic turbine on a four-column floating semisubmersible substructure . Simulations were performed using OpenFAST v4.1 with the Reference Open Source Controller (ROSCO) v2.10. All input files required to reproduce the simulations are included. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel . This unit supports up to 2.5 MW, but NLR has only a single 1.25-MW stack. The datasets report hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. The system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operating current of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The simulated tidal turbine time series data was translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz. Each zip file represents a single tidal electrolysis experiment and is named: {technology}_{inflow method}_{number of 500 kW tidal turbines connected} For instance, “tidal-500kW-RM1_average_2.zip” is a 6-hour experiment using the 500-kW tidal reference model, scaled by 2x (1-MW) to better match the electrolyzer maximum of 1.25MW, fed with the 30-minute moving average current case. Each zip folder contains the following files: A .csv file of raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. A .csv file combines all tidal profiles as "combined_tidal_experiments.csv." A separate experiment, “characterization_200.zip,” shows the MC250 electrolyzer steady-state response with 30-minute load steps over 5 hours and is accessible with this entry.

08 HYDROGEN↗

Permeation of CO 2 and N 2 through glassy poly(dimethyl phenylene) oxide under steady- and presteady-state conditions

Glassy polymers are often used for gas separations because of their high selectivity. Although the dual-mode permeation model correctly fits their sorption and permeation isotherms, its physical interpretation is disputed, and it does not describe permeation far from steady state, a condition expected when separations involve intermittent renewable energy sources. To develop a more comprehensive permeation model, we combine experiment, molecular dynamics, and multiscale reaction–diffusion modeling to characterize the time-dependent permeation of N 2 and CO 2 through a glassy poly(dimethyl phenylene oxide) membrane, a model system. Simulations of experimental time-dependent permeation data for both gases in the presteady-state and steady-state regimes show that both single- and dual-mode reaction–diffusion models reproduce the experimental observations, and that sorbed gas concentrations lag the external pressure rise. The results point to environment-sensitive diffusion coefficients as a vital characteristic of transport in glassy polymers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaporation due to infrared heating and natural convection

The results obtained from a drying experiment under infrared heating are compared to those obtained from correlations for the mass transfer coefficients, which are commonly used to obtain evaporation rates for drying applications. It was shown that the mass transfer coefficients evaluated by natural convection correlations are approximately ten times lower than those measured under infrared (IR) exposure. In this work, an attempt to explain this discrepancy, which has been also observed in other studies and explained on the basis of thermal radiation effects, optical properties of NMP are presented and the implications of the IR and near infrared (NIR) spectrum on the thermal radiation effects and ensuing evaporation rates are discussed. The results show that expected raise in the film temperature, which would be due to the thermal radiation effects, cannot be used to describe the measured evaporation rates for this solvent. Therefore, this study provides important evaporation mass flux data, which cannot be predicted using traditional correlations, for the design of IR assisted drying systems used in membrane fabrication.

42 ENGINEERING↗

ezAlign

The ezAlign is aimed at clustering coarse grain simulation to find common or uncommon occurrences and convert coarse (CG) grained coordinate and topology files to atomistic formats. We use a PointNet based approach to map individual frames of simulation to points in a latent space. These points are then clustered using a variety of clustering methods. Clusters are analyzed to associate them with states in the simulation. Frames can be chosen from these clusters based on proximity to cluster centers. ezAlign takes CG coordinate and topology files and converts and outputs their corresponding atomistic formats using an alignment and relaxation procedure. ezAlign is designed to convert complex, solvated biological systems including lipid membranes with drug-like molecules using GROMACS. A GROMACS checkpoint (.cpt) file is also outputted to enable continuation simulations that retain the equilibrated atomic velocities. Independent atomistic coordinates and topologies for every molecule must already be included in ezAlign/files. A number of commonly simulated biological molecules are currently provided.

Bennett, WilliamF.↗

System and method for synthesis of dialkyl carbonates using carbon dioxide reaction with methanol and ammonia

A method and system for membrane-assisted production of high purity concentrated dimethyl carbonate by the reaction of carbon dioxide and methanol is provided. Carbon dioxide is recovered from flue gas or other dilute streams from industrial processes by a membrane and subsequent conversion takes place to an intermediate methyl carbamate by reacting of carbon dioxide with ammonia and methanol. For high-purity carbon dioxide obtained by one of the carbon capture technologies or by a process (such as, for example, ethanol fermentation process) the membrane reactor is replaced with a catalytic reactor for direct conversion of carbon dioxide to methyl carbamate by reacting with ammonia and methanol. The methyl carbamate is further reacted with methanol for conversion to dimethyl carbonate. An integrated reactive distillation process using side reactors is used for facilitating the catalytic reaction in the subject method for producing high purity dimethyl carbonate.

Panchal, Chandrakant B.↗

Manufacturing Cost Analysis for PEM Electrolyzers and Perspectives for Future Cost Reduction

Electrolyzer capital costs strongly influence the total levelized cost of hydrogen production and have implications for hydrogen deployment. Current electrolyzer costs are high, and large cost reductions may be needed to achieve competitive hydrogen costs and targets. Understanding pathways for cost reduction via R&D and deployment is a critical research area for informed energy planning and enabling hydrogen use. This work presents bottom-up cost estimates of polymer electrolyte membrane (PEM) electrolyzer systems tied to design specifications and discusses perspectives for cost reduction opportunities based on ongoing research. We use a detailed manufacturing and process model for a 1 MW PEM electrolyzer stack and balance of plant (BOP) for rigorous cost estimation. This allows for robust estimates of component and manufacturing costs and examination of key cost contributors. Stack costs are dominated by material costs such as iridium and platinum catalysts, especially at high manufacturing rates; power electronics and hydrogen purification equipment are the largest contributors to BOP cost. At higher manufacturing rates, better equipment utilization could reduce stack costs significantly, and we estimate that experience and bulk purchasing will allow for cost reductions to some BOP components. Still, many well-established BOP technologies and stack material costs are less likely to see significant cost reductions at high manufacturing rates. As such, manufacturing scale is limited in how much it can reduce electrolyzer costs, and additional advances for cost reduction may be needed to achieve cost targets. It will likely take many combined strategies to achieve significant cost reductions for electrolyzers and enable low-cost hydrogen production. We can use our manufacturing cost model to quantify potential cost reductions from the considerations described above and demonstrate pathways to lower cost electrolyzers. This allows for better understanding of cost reduction strategies and enables more informed research, development, and deployment for electrolyzers.

cost↗

Method and system for electrochemically compressing gaseous hydrogen

Method and system for electrochemically compressing hydrogen. In one embodiment, the system includes a membrane electrode assembly (MEA) that includes a polymer electrolyte membrane (PEM), an anode, and a cathode. First and second gas diffusion media are positioned adjacent the cathode and anode, respectively. A humidifying membrane is positioned next to the second gas diffusion medium on a side opposite the anode. A water supply is connected to the humidifying membrane, and a hydrogen gas supply is connected to the second gas diffusion medium. A hydrogen gas collector including a back pressure regulator is connected to the first gas diffusion medium. Separators, positioned on opposite sides of the MEA, are connected to a power source. In use, hydrogen is electrochemically pumped across the MEA and collected in the hydrogen gas collector. The PEM is kept properly humidified by the humidifying membrane, which releases water into the second gas diffusion medium.

Hamdan, Monjid↗

Nanoconfinement of Carbon Dioxide within Interfacial Aqueous/Ionic Liquid Systems

Nanoporous, gas-selective membranes have shown encouraging results for the removal of CO 2 from flue gas, yet the optimal design for such membranes is often unknown. Therefore, we used molecular dynamics simulations to elucidate the behavior of CO 2 within aqueous and ionic liquid (IL) systems ([EMIM][TFSI] and [OMIM][TFSI]), both confined individually and as an interfacial aqueous/IL system. We found that within aqueous systems the mobility of CO 2 is reduced due to interactions between the CO 2 oxygens and hydroxyl groups on the pore surface. Within the IL systems, we found that confinement has a greater effect on the [EMIM][TFSI] system as opposed to the [OMIM][TFSI] system. Paradoxically, the larger and more asymmetrical [OMIM]+ molecule undergoes less efficient packing, resulting in fewer confinement effects. Finally, free energy surfaces of the nanoconfined aqueous/IL interface demonstrate that CO 2 will transfer spontaneously from the aqueous to the IL phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Collaboration on SBIR/TTO Phase II Project for Optical QC Device and Collaboration on SBIR/TTO Phase II-b Project for Advanced Quality Inspection Device Development: Cooperative Research and Development CRADA Number CRD-16-00652 (Final Report)

The overall goal of this program is to develop and commercialize a turnkey quality control solution for the entire PEM fuel cell manufacturing process including membrane, gas diffusion layers, catalyst, and assembled systems. This quality control solution is unique to each customer’s specific needs but includes a suite of in-line quality control systems for roll-to-roll manufacturing that can target thin, transparent membrane as well as opaque membrane, catalyst, and GDLs. The Phase II developed the CPNUVV system for thin, transparent membrane that operates using polarized filters to enhance defect resolution and determine thickness. However, PEM material manufacturers want a complete, turnkey solution for all components of the PEM fuel cell. In the Phase IIB, Mainstream will partner with NREL, and transition reflectance technology NREL developed (US Patent 9,234,843) to operate in real-time on a web-line to develop a total solution to PEM quality control. The device will identify and mark defects as well as monitor materials thickness in real-time to improve line efficiency and to reduce waste. The research performed at NREL under this CRADA increases the basis of knowledge about optical inspection methods, how they perform with regards to fuel cell component materials, and how they can be implemented in in-line, real-time configurations to provide quality inspection for roll-to-roll (R2R) manufacturing. Methods explored were found to be sensitive to catalyst loading in electrodes on both membrane and gas diffusion media substrates and to membrane thickness, across a broad range of thickness. The latter capability is novel and now patented and provides a previously unstudied and undemonstrated capability for R2R manufacturing of membranes.

30 DIRECT ENERGY CONVERSION↗

Vitamin E Acetate Causes Softening of Pulmonary Surfactant Membrane Models

The popularity of electronic cigarettes and vaping products has launched the outbreak of a condition affecting the respiratory system of users, known as electronic-cigarette/vaping-associated lung injury (EVALI). The build-up of vitamin E acetate (VEA), a diluent of some illicit vaping oils, in the bronchoalveolar lavage of patients with EVALI provided circumstantial evidence as a target for investigation. In this work, we provide a fundamental characterization of the interaction of VEA with lung cells and pulmonary surfactant (PS) models to explore the mechanisms by which vaping-related lung injuries may be present. We first confirm the localization and uptake of VEA in pulmonary epithelial cells. Further, as PS is vitally responsible for the biophysical functions of the lungs, we explore the effect of added VEA on three increasingly complex models of PS: dipalmitoylphosphatidylcholine (DPPC), a lipid-only synthetic PS, and the biologically derived extract Curosurf. Using high-resolution techniques of small-angle X-ray scattering, small-angle neutron scattering, neutron spin–echo spectroscopy, and neutron reflectometry, we compare the molecular-scale behaviors of these membranes to the bulk viscoelastic properties of surfactant monolayer films as studied by Langmuir monolayer techniques. While VEA does not obviously alter the structure or organization of PS membranes, a consistent softening of membrane systems—regardless of compositional complexity—provides a biophysical explanation for the respiratory distress associated with EVALI and yields a new perspective on the behavior of the PS system.

59 BASIC BIOLOGICAL SCIENCES↗