Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Membrane”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Characterization of a Sulfonated Poly(Ionic Liquid) Block Copolymer as an Ionomer for Proton Exchange Membrane Fuel Cells using Rotating Disk Electrode

Ionic liquid (IL) additives to both traditional and advanced oxygen reduction reaction (ORR) electrocatalysts have yielded remarkable improvements in catalyst performance and durability. However, incorporating ILs or IL-modified catalysts into the electrodes of a proton exchange membrane fuel cell (PEMFC) membrane electrode assembly (MEA) has proven to be challenging. Sulfonated poly(ionic liquid) block copolymers (S-PILBCP) present an opportunity to incorporate IL functionality directly into the ionomer, orthogonal to protonic conductivity. Here, we use a rotating disc electrode (RDE) to characterize the interface between a S-PILBCP and Pt catalyst in comparison to Nafion. Catalyst thin films prepared with S-PILBCP show an 80% improvement in the ORR activity over those containing Nafion. Thin films of S-PILBCP also show a significantly reduced degree of poisoning sulfonate adsorption on a Pt(111) surface in comparison to Nafion. Furthermore, these half-cell results provide useful insights that help to highlight the source of the impact of the S-PILBCP on PEMFC MEA performance.

25 ENERGY STORAGE↗

Contaminant Cation Effect on Oxygen Transport through the Ionomers of Polymer Electrolyte Membrane Fuel Cells

We characterized the effects of cobalt (Co 2+ ) and other cation contaminants on the oxygen (O 2 ) transport properties of the PFSA ionomer used in polymer electrolyte membrane fuel cells (PEMFCs) and gained insight into the mechanisms by which contaminant cations inhibit O 2 transport. Such cations can be released by alloy catalysts and environmental conditions and pose a significant challenge to maintaining high current density performance with low platinum (Pt) loadings. We used a test cell capable of isolating the ionomer from the membrane electrode assembly (MEA), allowing for O 2 transport resistance (R O2 ) measurements using a limiting current technique. We contaminated ionomer membranes with Li + , Na + , Ni 2+ , Co 2+ , and Ce 3+ and found a general increase in R O2 for increased contamination levels and decreased water activity. In addition, our Co 2+ results indicated distinct concentration-dependent regimes. The other cation-form ionomers allowed us to separate the impacts of ion pair strength, multivalency, and reduced water uptake. We believe that these factors cause a more compressed hydrophilic domain and tortuous O 2 diffusion path, and a commensurate increase in R O2 . Lastly, we studied the impact of Co 2+ on an operating PEMFC and found an increase in R O2 consistent with the results of our isolated membrane tests.

25 ENERGY STORAGE↗

Three-dimensional photonic crystals by large-area membrane stacking

We designed and analyzed a “mesh-stack” three-dimensional photonic crystal of a 12.4% bandgap with a dielectric constant ratio of 12:1. The mesh-stack consists of four offset identical square-lattice air-hole patterned membranes in each vertical period that is equal to the in-plane period of the square lattice. This design is fully compatible with the membrane-stacking fabrication method, which is based on alignment and stacking of large-area single-crystal membranes containing engineered defects. A bandgap greater than 10% is preserved as long as the membranes are subjected to in-plane misalignment less than 3% of the square period. By introducing a linear defect with a nonsymmorphic symmetry into the mesh-stack, we achieved a single-mode waveguide over a wide bandwidth.

36 MATERIALS SCIENCE↗

Sheet Membrane Spacesuit Water Membrane Evaporator Thermal Test

For future lunar extravehicular activities (EVA), one method under consideration for rejecting crew and electronics heat involves evaporating water through a hydrophobic, porous Teflon(Registered Trademark) membrane. A Spacesuit Water Membrane Evaporator (SWME) prototype using this membrane was successfully tested by Ungar and Thomas (2001) with predicted performance matching test data well. The above referenced work laid the foundation for the design of a compact sheet membrane SWME development unit for use in the Constellation System Spacesuit Element Portable Life Support System (Vogel and et. al., ICES 2008). Major design objectives included minimizing mass, volume, and manufacturing complexity while rejecting a minimum of 810 watts of heat from water flowing through the SWME at 91 kg/hr with an inlet temperature of 291K. The design meeting these objectives consisted of three concentric cylindrical water channels interlaced with four water vapor channels. Two units were manufactured for the purpose of investigating manufacturing techniques and performing thermal testing. The extensive thermal test measured SWME heat rejection as a function of water inlet temperatures, water flow-rates, water absolute pressures, water impurities, and water vapor back-pressures. This paper presents the test results and subsequent analysis, which includes a comparison of SWME heat rejection measurements to pretest predictions. In addition, test measurements were taken such that an analysis of the commercial-off-the-shelf vapor pressure control valve could be performed.

Trevino, Luis A.↗

Composite Membranes for CO2 Capture: High Performance Metal Organic Frameworks/Polymer Composite Membranes for Carbon Dioxide Capture

IMPACCT Project: A team of six faculty members at Georgia Tech are developing an enhanced membrane by fitting metal organic frameworks, compounds that show great promise for improved carbon capture, into hollow fiber membranes. This new material would be highly efficient at removing CO2 from the flue gas produced at coal-fired power plants. The team is analyzing thousands of metal organic frameworks to identify those that are most suitable for carbon capture based both on their ability to allow coal exhaust to pass easily through them and their ability to select CO2 from that exhaust for capture and storage. The most suitable frameworks would be inserted into the walls of the hollow fiber membranes, making the technology readily scalable due to their high surface area. This composite membrane would be highly stable, withstanding the harsh gas environment found in coal exhaust.

ARPA-E↗

Gelled Ionic Liquid-Based Membranes: Achieving a 10,000 GPU Permeance for Post-Combustion Carbon Capture with Gelled Ionic Liquid-Based Membranes

IMPACCT Project: Alongside Los Alamos National Laboratory and the Electric Power Research Institute, CU-Boulder is developing a membrane made of a gelled ionic liquid to capture CO2 from the exhaust of coal-fired power plants. The membranes are created by spraying the gelled ionic liquids in thin layers onto porous support structures using a specialized coating technique. The new membrane is highly efficient at pulling CO2 out of coal-derived flue gas exhaust while restricting the flow of other materials through it. The design involves few chemicals or moving parts and is more mechanically stable than current technologies. The team is now working to further optimize the gelled materials for CO2 separation and create a membrane layer that is less than 1 micrometer thick.

ARPA-E↗

Zeolite membranes, molecular separation methods, and manufacturing processes for zeolite membranes

Disclosed are methods of manufacturing a zeolite membrane, comprising: providing at least one porous substrate; and coating the at least one porous substrate with a membrane. In some embodiments, the method further comprises hydrothermally treating the membrane with a first hydrothermal treatment step with tetrapropylammonium fluoride (TPAF) and a second hydrothermal treatment step with tetraethylammonium hydroxide (TEAOH). In some embodiments, coating the substrate with a membrane comprises surrounding at least a portion of the at least one porous substrate with a precursor gel, the gel comprising a gel phase and a plurality of CHA or MFI crystals; heating the at least one porous substrate and the precursor gel; washing the at least one porous substrate; drying the at least one porous substrate; and calcining the at least one porous substrate.

Nair, Sankar↗

Glycerol-Induced Membrane Stiffening: The Role of Viscous Fluid Adlayers

Lipid interfaces, ranging from cell membranes to thin surfactant layers that stabilize lung alveoli, are integral to living systems. Such interfaces are often subjected to mechanical forces, and because of their membrane-like geometry, they can easily deform by bending into localized folds. In this work, we explore the role of small molecules (i.e., glycerol) on the mechanical stability of model lung surfactant monolayers. We demonstrate that the presence of glycerol increases local monolayer bending stiffness by orders of magnitude. Our x-ray and neutron reflectivity measurements indicate that water is preferentially depleted, or glycerol is preferentially enriched, at the lipid headgroup/solvent interface, and that this glycerol-enriched layer extends O(10) beneath the monolayer with an adsorption free energy of 2.5 to 4.6 kJ/mol. The dramatic change in membrane bending stiffness in the presence of the sugar adlayer is understood in terms of two models: (1), lipid antiplasticization by glycerol; and (2), a continuum mechanical model of the viscous adlayer.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of a Cross-Flow Humidifier with a High Flux Water Vapor Transport Membrane

Water vapor transport (WVT) flux across a composite membrane that consists of a very thin perfluorosulfonic acid (PFSA) ionomer layer sandwiched between two expanded polytetrafluoroethylene (PTFE) microporous layers is investigated. Static and dynamic tests are conducted to measure WVT flux for different composite structures; a transport model shows that the underlying individual resistances for water diffusion in the gas phase and microporous and ionomer layers and for interfacial kinetics of water uptake at the ionomer surface are equally important under different conditions. A finite-difference model is formulated to determine water transport in a full-scale (2-m2 active membrane area) planar cross-flow humidifier module assembled using pleats of the optimized composite membrane. In agreement with the experimental data, the modeled WVT flux in the module increases at higher inlet relative humidity (RH) of the wet stream and at lower pressures, but the mass transfer effectiveness is higher at higher pressures. The model indicates that the WVT flux is highest under conditions that maintain the wet stream at close to 100% RH while preventing the dry stream from becoming saturated. The overall water transport is determined by the gradient in RH of the wet and dry streams but is also affected by vapor diffusion in the gas layer and the microporous layer.

combined thermal and mass transfer↗

Increasing the Electrolyte Salinity to Improve the Performance of Anion Exchange Membrane Water Electrolyzers

Direct operation of anion exchange membrane water electrolyzers (AEMWEs) with near-neutral pH feeds avoids the use of highly alkaline and corrosive solutions. However, using neutral pH solutions currently faces fundamental operational challenges that diminish performance and reduce long-term stability due to poor solution conductivity and low hydroxide ion concentration. Here, we showed that amending near-neutral pH solutions with low concentrations of alkali metal salts in a dry-cathode configuration substantially improved performance and stability. Adding NaClO 4 (10 mM) to the anolyte reduced the operating voltage by 0.19 to 2.58 V at 500 mA/cm 2 compared to non-saline solutions (2.77 V). However, further increases in the feed salt concentration (100 mM NaClO 4 ) reduced performance (2.64 V) due to a greater co-ion diffusion through the anion exchange membrane. Electrolyzer performance was further improved by utilizing salts with high conductivity such as KNO 3 . Using a saline anolyte reduced ohmic resistance, resulting in smaller applied voltage and energy consumption for hydrogen generation, while the combined effect of the membrane charge and the electric field direction in the dry-cathode feed configuration minimized ion crossover. Thus, increasing the salinity of near-neutral pH solutions represents a cost-effective strategy to improve the performance of AEMWE compared to ultrapure electrolytes, minimizing risks and costs associated with recirculating highly alkaline solutions.

anion exchange membrane water electrolyzer↗

Combinatorial Membrane Synthesis: Fundamentals of Hybrid Metal-Organic Brush (MOB) Membranes for Organic Solvent Nanofiltration (Renewal)

(a) Goals: The goals of our current 3-year research project are (i) expansion of the novel modification technique Single Electron Transfer- Living Radical Polymerization (SET-LRP) to graft polymer brushes on a polyimide stable support followed by characterization and testing of the ensuing membrane (ii) stiffen brush network utilizing (a) metal organic frameworks and (b) covalent bonds formed as a result of crosslinking the grafted brush network. (b) Approach: The approach taken for this research was: (i) to graft branches terminated with a carboxyl group on each bristle (or bristle branch) allowing (a) metal immobilization to form MOF-like structures between branches or (b) crosslink bristles using aliphatic or aromatic diamines; (ii) to test the performance of the membranes using organic dyes, pure solvents (alcohols) and industrially relevant organic solvent separations; and (iii) to characterize these modified brush membranes. (c) Findings: The significant findings from the past one year are summarized below (papers resulting from this work are listed below and in D. PUBLICATIONS and relevant references are found in E. REFERENCES.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Adsorptive Membrane Platform for Precision Ion Separation: Membrane Design and First‐Principles Studies

One of the key challenges in separation science is the lack of precise ion separation methods and mechanistic understanding crucial for efficiently recovering critical materials from complex aqueous matrices. Herein, first-principles electronic structure calculations and in situ Raman spectroscopy are studied to elucidate the factors governing ion discrimination in an adsorptive membrane specifically designed for transition metal ion separation. Density functional theory calculations and in situ Raman data jointly reveal the thermodynamically favorable binding preferences and detailed adsorption mechanisms for competing ions. How membrane binding preferences correlate with the electronic properties of ligands is explored, such as orbital hybridization and electron localization. The findings underscore the importance of the phenolate group in oxime ligands for achieving high selectivity among competing transition metal ions. In-depth understanding on which specific atomistic site within the microenvironment of metal-ligand binding pockets governs the ion discrimination behaviors of the host will build a solid foundation to guide the rational design of next-generation materials for precision separation essential for energy technologies and environment remediation. In tandem, synthetic controllability is demonstrated to transform 3D micrometer-scale crystals to a 2D crystalline selective layer in membranes, paving the way for more precise and sustainable advances in separation science.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Separating Miscible Liquid–Liquid Mixtures Using Supported Ionic Liquid Membranes

Supported liquid membranes (SLMs) are promising in separating miscible liquid–liquid mixtures, which has been a key challenge in wastewater treatment and other applications. However, SLMs suffer from poor durability due to the loss of the liquid phase. In current work, ionic liquids (ILs) with high stability have been impregnated into polyvinylidene fluoride membranes to separate miscible benzene–heptane mixtures. The two imidazolium-based ILs, that is, 1-butyl-3-methylimidazolium hexafluorophosphate ([BMIM][PF 6 ]) and 1-butyl-3-methylimidazolium tris(pentafluoroethyl) trifluorophosphate ([BMIM][FAP]), were tested in supported ionic liquid membranes (SILMs) for the benzene–heptane separation. Both ILs show successful separation within 48 h as indicated by nuclear magnetic resonance results. Compared to the SILM with [BMIM][FAP], the SILM with [BMIM][PF 6 ] has lower throughput and higher selectivity. The higher selectivity can be attributed to the higher hydrophilicity of [BMIM][PF 6 ], which results in strong repulsion against heptane. The lower throughput can be attributed to the higher hydrophilicity as well since it lowers the solubility of benzene in [BMIM][PF 6 ]. The stability of IL in SILMs has also been investigated via multiple separation cycles. The scanning electron microscopy, weight change of SILMs, and separation results indicate that the separation efficiency of the [BMIM][PF 6 ] SILM does not degrade for up to 144 h. The SILM has been further optimized with curvature design (i.e., curved SILM) to increase the interfacial area and thus increase the separation throughput, where the curved SILM separation device was 3D-printed. Here, the findings here have important implications on design and application of SILMs in separating miscible liquid–liquid mixtures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three-Electrode Study of Electrochemical Ionomer Degradation Relevant to Anion-Exchange-Membrane Water Electrolyzers

Among existing water electrolysis (WE) technologies, anion-exchange-membrane water electrolyzers (AEMWEs) show promise for low-cost operation enabled by the basic solid-polymer electrolyte used to conduct hydroxide ions. The basic environment within the electrolyzer, in principle, allows the use of non-platinum-group metal catalysts and less-expensive cell components compared to acidic-membrane systems. Nevertheless, AEMWEs are still underdeveloped, and the degradation and failure modes are not well understood. To improve performance and durability, supporting electrolytes such as KOH and K 2 CO 3 are often added to the water feed. The effect of the anion interactions with the ionomer membrane (particularly other than OH – ), however, remains poorly understood. We studied three commercial anion-exchange ionomers (Aemion, Sustainion, and PiperION) during oxygen evolution (OER) at oxidizing potentials in several supporting electrolytes and characterized their chemical stability with surface-sensitive techniques. We analyzed factors including the ionomer conductivity, redox potential, and pH tolerance to determine what governs ionomer stability during OER. Specifically, we discovered that the oxidation of Aemion at the electrode surface is favored in the presence of CO 3 2– /HCO 3 – anions perhaps due to the poor conductivity of that ionomer in the carbonate/bicarbonate form. Sustainion tends to lose its charge-carrying groups as a result of electrochemical degradation favored in basic electrolytes. PiperION seems to be similarly negatively affected by a pH drop and low carbonate/bicarbonate conductivity under the applied oxidizing potential. Furthermore, the insight into the interactions of the supporting electrolyte anions with the ionomer/membrane helps shed light on some of the degradation pathways possible inside of the AEMWE and enables the informed design of materials for water electrolysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Reference Electrodes in Anion-Exchange-Membrane Electrolyzers: Impact of Stainless-Steel Gas-Diffusion Layers and Internal Mechanical Pressure

Alkaline-membrane electrolyzers operating in pure water might provide scalable low-cost H 2 production but currently lag in performance and durability compared to commercial technologies. Typically, membrane–electrode assemblies (MEAs) are optimized in electrolyzers by changing one parameter at a time and assessing the resulting system performance via two-electrode polarization and impedance measurements. These approaches are limited in their ability to assign performance changes and durability to specific electrodes or processes. We integrate a reference electrode with the MEA to separate anode and cathode responses in both polarization and impedance measurements. Here we illustrate the power of the approach by showing how the fiber diameter of stainless-steel gas-diffusion layers (GDLs) affects performance solely at the anode, while changing the thickness of the cathode GDL simultaneously affects the performance of the anode and cathode due to changes in internal pressure from mechanical compression. This finding was obscured in conventional two-electrode measurements. The work thus guides both high-performance alkaline-membrane water-electrolyzer development and illustrates a useful strategy to study structure–activity relationships in the MEA.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗