The Marine and Hydrokinetic ToolKit (MHKiT) for Data Quality Control and Analysis [Slides]

The ability to collect, ingest, condition, reduce, quality control, process, visualize, and store data in a standardized way is critical at all stages of Marine Energy (ME) research and technology/project development. MHKiT is an open-source, standardized suite of ME data processing functions that provides the ability to ingest, condition, reduce, quality control, process, visualize and store ME data. MHKiT is developed in both Python and Matlab.

16 TIDAL AND WAVE POWER↗

Dynamic Modeling of Near Isothermal Compressor for Transcritical Carbon Dioxide Cycle

Compressors are the major energy consumption components in vapor compression systems, drawing much research effort in reducing carbon emissions. The isothermal compressor integrates the compressor chamber and gas cooler to achieve near isothermal compression, reaching up to 30% energy reduction compared to the traditional isentropic compression work. This paper presents a detailed isothermal compressor model combined with a generalized liquid piston model to account for the carbon dioxide (CO2) isothermal compression process. The model is established based on MATLAB environment. The model uses the real experimental data as boundary conditions and initial settings, which also considers the CO2 solubility in liquid piston (mineral oil) for designing, optimizing and customizing the compression chambers. The validation was carried out with experimental data using a prototype with 3.5 kW capacity. The results have demonstrated the accuracy of the dynamic model (6.2% relative error for chamber pressure and 0.5 K deviation for chamber temperature), which provide a guideline for designing and customizing the isothermal compression cycle.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Neural Network Code MATLAB

SAND2022-12606 O Neural Network Code MATLAB reads in an excel file, processes the data, trains a neural network, and tests the neural network. The code generates predictions of diffusion constants based on the data in the excel file. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Allers, Joshua↗

Practical Guide to Chemometric Analysis of Optical Spectroscopic Data

The methodology and mathematical treatment of several classic multivariate methods for the analysis of spectroscopic data is demonstrated in a straightforward way that can be used as a basis for teaching an undergraduate introductory course on chemometric analysis. The multivariate techniques of classical least squares (CLS), principal component regression (PCR), and partial least squares (PLS), as well as the univariate Beer’s law method have been described and compared, building students’ understanding by starting with the univariate method and progressing step by step into the multivariate methods. Equations for the production of regression vectors from training set spectral data is described and their use demonstrated for the prediction of constituent concentrations on a separate validation set of spectra. Extreme care is taken to ensure consistency in variable formatting of data matrices. This provides a key foundation to understanding how spectral data are manipulated using these different mathematical approaches for building quantitative regression models. Each method is applied to a real-world data set, and the results are discussed to show students the types of information that can be gleaned from each method. A training set comprised of 20 infrared absorbance spectra containing 3 constituents (benzene, polystyrene, and gasoline) of known composition are used to demonstrate the matrix operations for each regression method. A separate set of 12 real-world napalm samples (containing benzene, polystyrene and gasoline) are used as a validation set to demonstrate the ability to utilize the regression models on an unknown dataset. A toolbox (PNNL Chemometric Toolbox) written in MATLAB language is supplied in the Supplemental Information file and can be used as a companion for understanding the development and deployment of the chemometric algorithms described in this paper. The datasets of the infrared spectra are also supplied, allowing users to build and inspect the chemometric models on their own. Finally, the Toolbox includes scripts to assist users in loading their own datasets into MATLAB and performing CLS, PCR, and PLS on their data.

Upper-Division Undergraduate, Analytical Chemistry↗

SRNL Analysis of ICCWR LCM and WAMS data for Corrosion and Cracking (FY2020 Progress Report)

The development of algorithms for machine learning and data analysis for the 3013 Surveillance Program is a collaborative effort by the Savannah River National Laboratory (SRNL) and the University of South Carolina (USC). For corrosion detection, Laser Confocal Microscope (LCM) or Wide Area 3D Measurement System (WAMS) data is extracted from large binary files, with software written to convert the data to physical attributes (e.g. height, color and grayscale values; all as functions of a location in a plane projection). It is the objective of this project to produce a user-friendly interface that incorporated all operations needed to perform surface examination. For this reason, a Matlab-based Graphical User Interface (GUI) was created to integrate data input with software developed for processing and evaluation. In summary, the GUI permits selective downloading of binary data, interrogation of attributes, data labeling, flagging of significant features, execution of Machine Learning (ML) algorithms, output of parameters for trained ML algorithms, reports of ML model accuracy with respect to labeled data, and generation of graphical representations of various analyses.

3013 corrosion↗

IBEX: An open infrastructure software platform to facilitate collaborative work in radiomics

Purpose: Radiomics, which is the high-throughput extraction and analysis of quantitative image features, has been shown to have considerable potential to quantify the tumor phenotype. However, at present, a lack of software infrastructure has impeded the development of radiomics and its applications. Therefore, the authors developed the imaging biomarker explorer (IBEX), an open infrastructure software platform that flexibly supports common radiomics workflow tasks such as multimodality image data import and review, development of feature extraction algorithms, model validation, and consistent data sharing among multiple institutions. Methods: The IBEX software package was developed using the MATLAB and C/C++ programming languages. The software architecture deploys the modern model-view-controller, unit testing, and function handle programming concepts to isolate each quantitative imaging analysis task, to validate if their relevant data and algorithms are fit for use, and to plug in new modules. On one hand, IBEX is self-contained and ready to use: it has implemented common data importers, common image filters, and common feature extraction algorithms. On the other hand, IBEX provides an integrated development environment on top of MATLAB and C/C++, so users are not limited to its built-in functions. In the IBEX developer studio, users can plug in, debug, and test new algorithms, extending IBEX’s functionality. IBEX also supports quality assurance for data and feature algorithms: image data, regions of interest, and feature algorithm-related data can be reviewed, validated, and/or modified. More importantly, two key elements in collaborative workflows, the consistency of data sharing and the reproducibility of calculation result, are embedded in the IBEX workflow: image data, feature algorithms, and model validation including newly developed ones from different users can be easily and consistently shared so that results can be more easily reproduced between institutions. Results: Researchers with a variety of technical skill levels, including radiation oncologists, physicists, and computer scientists, have found the IBEX software to be intuitive, powerful, and easy to use. IBEX can be run at any computer with the windows operating system and 1GB RAM. The authors fully validated the implementation of all importers, preprocessing algorithms, and feature extraction algorithms. Windows version 1.0 beta of stand-alone IBEX and IBEX’s source code can be downloaded. Conclusions: The authors successfully implemented IBEX, an open infrastructure software platform that streamlines common radiomics workflow tasks. Its transparency, flexibility, and portability can greatly accelerate the pace of radiomics research and pave the way toward successful clinical translation.

60 APPLIED LIFE SCIENCES↗

Small Scale WEC Performance Modeling Data

Small Scale WEC Performance Modeling Data is performance data from downscaled models of common WEC devices and their calculated performance outputs. This data is used by the Small WEC interactive modeling tool hosted by PRIMRE. The devices include a point absorber, a two-body point absorber (RM3), an oscillating surge device (OSWEC), and an attenuator type device (McCabe Wave Pump). One of the primary use cases for this work is to give an easy way to compare power output for a variety of WECs and model sizes.

16 TIDAL AND WAVE POWER↗

SU-F-T-458: Tracking Trends of TG-142 Parameters Via Analysis of Data Recorded by 2D Chamber Array

Purpose: With increasing QA demands of medical physicists in clinical radiation oncology, the need for an effective method of tracking clinical data has become paramount. A tool was produced which scans through data automatically recorded by a 2D chamber array and extracts relevant information recommended by TG-142. Using this extracted information a timely and comprehensive analysis of QA parameters can be easily performed enabling efficient monthly checks on multiple linear accelerators simultaneously. Methods: A PTW STARCHECK chamber array was used to record several months of beam outputs from two Varian 2100 series linear accelerators and a Varian NovalisTx−. In conjunction with the chamber array, a beam quality phantom was used to simultaneously to determine beam quality. A minimalist GUI was created in MatLab that allows a user to set the file path of the data for each modality to be analyzed. These file paths are recorded to a MatLab structure and then subsequently accessed by a script written in Python (version 3.5.1) which then extracts values required to perform monthly checks as outlined by recommendations from TG-142. The script incorporates calculations to determine if the values recorded by the chamber array fall within an acceptable threshold. Results: Values obtained by the script are written to a spreadsheet where results can be easily viewed and annotated with a “pass” or “fail” and saved for further analysis. In addition to creating a new scheme for reviewing monthly checks, this application allows for able to succinctly store data for follow up analysis. Conclusion: By utilizing this tool, parameters recommended by TG-142 for multiple linear accelerators can be rapidly obtained and analyzed which can be used for evaluation of monthly checks.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-F-16A-01: Implementation of MPPG TPS Verification Tests On Various Accelerators

Purpose: To demonstrate the implementation of the Medical Physics Practice Guideline (MPPG) for dose calculation and beam parameters verification of treatment planning systems (TPS). Methods: We implemented the draft TPS MPPG for three linacs: Varian Trilogy, TomoHDA and Elekta Infinity. Static and modulated test plans were created. The static fields are different than used in commissioning. Data was collected using ion chambers and diodes in a scanning water tank, Delta4 phantom and a custom phantom. MatLab and Microsoft Excel were used to create analysis tools to compare reference DICOM dose with scan data. This custom code allowed for the interpolation, registration and gamma analysis of arbitrary dose profiles. It will be provided as open source code. IMRT fields were validated with Delta4 registration and comparison tools. The time for each task was recorded. Results: The tests confirmed the strengths, and revealed some limitations, of our TPS. The agreement between calculated and measured dose was reported for all beams. For static fields, percent depth dose and profiles were analyzed with criteria in the draft MPPG. The results reveal areas of slight mismatch with the model (MLC leaf penumbra, buildup region.) For TomoTherapy, the IMRT plan 2%/2 mm gamma analysis revealed poorest agreement in the low dose regions. For one static test plan for all 10MV Trilogy photon beams, the plan generation, scan queue creation, data collection, data analysis and report took 2 hours, excluding tank setup. Conclusions: We have demonstrated the implementation feasibility of the TPS MPPG. This exercise generated an open source tool for dose comparisons between scan data and DICOM dose data. An easily reproducible and efficient infrastructure with streamlined data collection was created for repeatable robust testing of the TPS. The tests revealed minor discrepancies in our models and areas for improvement that are being investigated.

07 ISOTOPE AND RADIATION SOURCES↗

An Automated, High-Throughput Method for Interpreting the Tandem Mass Spectra of Glycosaminoglycans

The biological interactions between glycosaminoglycans (GAGs) and other biomolecules are heavily influenced by structural features of the glycan. The structure of GAGs can be assigned using tandem mass spectrometry (MS{sup 2}), but analysis of these data, to date, requires manually interpretation, a slow process that presents a bottleneck to the broader deployment of this approach to solving biologically relevant problems. Automated interpretation remains a challenge, as GAG biosynthesis is not template-driven, and therefore, one cannot predict structures from genomic data, as is done with proteins. The lack of a structure database, a consequence of the non-template biosynthesis, requires a de novo approach to interpretation of the mass spectral data. We propose a model for rapid, high-throughput GAG analysis by using an approach in which candidate structures are scored for the likelihood that they would produce the features observed in the mass spectrum. To make this approach tractable, a genetic algorithm is used to greatly reduce the search-space of isomeric structures that are considered. The time required for analysis is significantly reduced compared to an approach in which every possible isomer is considered and scored. The model is coded in a software package using the MATLAB environment. This approach was tested on tandem mass spectrometry data for long-chain, moderately sulfated chondroitin sulfate oligomers that were derived from the proteoglycan bikunin. The bikunin data was previously interpreted manually. Our approach examines glycosidic fragments to localize SO{sub 3} modifications to specific residues and yields the same structures reported in literature, only much more quickly. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-QI-11: Measurement of Renal Pyruvate-To-Lactate Exchange with Hyperpolarized 13C MRI

Purpose: Previous work [1] modeling the metabolic flux between hyperpolarized [1-13C]pyruvate and [1-13C]lactate in magnetic resonance spectroscopic imaging (MRSI) experiments failed to account for vascular signal artifacts. Here, we investigate a method to minimize the vascular signal and its impact on the fidelity of metabolic modeling. Methods: MRSI was simulated for renal metabolism in MATLAB both with and without bipolar gradients. The resulting data were fit to a two-site exchange model [1], and the effects of vascular partial volume artifacts on kinetic modeling were assessed. Bipolar gradients were then incorporated into a gradient echo sequence to validate the simulations experimentally. The degree of diffusion weighting (b = 32 s/mm{sup 2}) was determined empirically from 1H imaging of murine renal vascular signal. The method was then tested in vivo using MRSI with bipolar gradients following injection of hyperpolarized [1-{sup 13}C]pyruvate (∼80 mM at 20% polarization). Results: In simulations, vascular signal contaminated the renal metabolic signal at resolutions as high as 2 × 2 mm{sup 2} due to partial volume effects. The apparent exchange rate from pyruvate to lactate (k{sub p}) was underestimated in the presence of these artifacts due to contaminating pyruvate signal. Incorporation of bipolar gradients suppressed vascular signal and improved the accuracy of kp estimation. Experimentally, the in vivo results supported the ability of bipolar gradients to suppress vascular signal. The in vivo exchange rate increased, as predicted in simulations, from k{sub p} = 0.012 s-{sup 1} to k{sub p} = 0.020-{sup 1} after vascular signal suppression. Conclusion: We have demonstrated the limited accuracy of the two-site exchange model in the presence of vascular partial volume artifacts. The addition of bipolar gradients suppressed vascular signal and improved model accuracy in simulations. Bipolar gradients largely affected kp estimation in vivo. Currently, slow-flowing spins in small vessels and capillaries are only partially suppressed, so further improvement is possible. Funding support: Seed Grant from the Radiological Society of North America, GE Healthcare, University of Wisconsin Graduate School.

60 APPLIED LIFE SCIENCES↗

yuwangcn/C4_dynamic_model

A dynamic systems model of C4 photosynthesis was developed based on the previous NADP-ME metabolic model for maize (Wang et al., 2014 ab). The NADP-ME metabolic model is an ordinary differential equation model including all individual steps in C4 photosynthetic carbon metabolism. Here, the model is extended to include posttranslational regulation and temperature response of enzyme activities, dynamic stomata conductance, and leaf energy balance. This model is written in Matlab (R2019a) Steady-state and dynamic gas exchange data for maize (B73), sugarcane (CP88-1762) and sorghum (Tx430) were measured in a greenhouse in Urbana, IL from July 25, 2019 through August 8, 2019. Data include: CO2 response curves Light response curves Photosynthetic induction curves measured in the transition from darkness to high light (1800 μmol m-2 s-1), data logged every 1 min. Photosynthetic induction in the transition from darkness to high light (1800 μmol m-2 s-1) to determine the kinetics of rubisco activation in these C4 crops (τ_Rubisco), data logged every 10 s. Gas exchange under fluctuating light. After dark adaptation, the leaves undergo three light change steps, light intensity was set as 1800 µmol m-2 s-1, 200 µmol m-2 s-1 and 1800 µmol m-2 s-1 for each 1800 s step.

Wang, Yu↗

Data, Photographs, Videos, and Information for the Niwot Ridge Subalpine Forest (US-NR1) AmeriFlux site

This data package contains data and information about the operation of the Niwot Ridge Subalpine Forest AmeriFlux site (US-NR1) between Nov 1998 to the present (2020). This data archive supplements the primary 30-min data storage for the US-NR1 data (i.e., https://doi.org/10.17190/AMF/1246088) by providing the following: (i) five-minute statistics (means, variances, covariances) of all data measured by the data system between Nov 1998 and September 2020 in netCDF format, (ii) CSV data files saved within the memory of the CR23X data loggers (as well as an archive of the data logger programs), (iii) an archive of previous 30-min ASCII data versions of the US-NR1 AmeriFlux data and information related to each data release (a replica of what can be found at http://urquell.colorado.edu/data_ameriflux/), (iv) a web calendar (in HTML format) documenting activity at the site (a replica of http://urquell.colorado.edu/calendar/), (v) photos (over 15,000) and video taken at the site between years 2001 and present day (2020), and (vi) several auxiliary datasets, primary related to trees near the site, soil moisture and soil temperature, and subcanopy radiation data. The data package is setup so that the web calendar, photos, and electronic logbook can be easily accessed on a local computer using a web browser. The provided data files are in either netCDF, CSV, ASCII, or MATLAB format. To obtain a better understanding about the archive, please start by reading the PDF: README_ESS_DIVE_USNR1_readme_first.pdf.

54 ENVIRONMENTAL SCIENCES↗

Surface Water Quality Data from Beaver-Impacted Streams; Trail Creek and East River, Colorado 2025

This data package contains surface water chemistry measurements collected in 2025 to evaluate how beaver damming and low-tech process-based stream restoration influence water quality and metal mobility in mountainous headwater systems of the Upper Colorado River Basin. Sampling was conducted at Trail Creek (Taylor Park watershed, Colorado), a tributary undergoing restoration through installation of low-tech process-based structures (i.e., beaver dam analogs), and at off-channel beaver ponds within the East River floodplain (East River watershed, Colorado). Samples were collected along longitudinal transects spanning upstream control reaches, beaver-influenced ponded reaches, and downstream segments. Additional samples were collected from near-surface pore waters within a beaver dam seepage face. The dataset includes concentrations of major and trace elements measured by inductively coupled plasma–mass spectrometry (ICP-MS) and inductively coupled plasma–optical emission spectrometry (ICP-OES), major anions measured by ion chromatography (IC), and dissolved organic carbon (DOC; reported as non-purgeable organic carbon, NPOC). Samples were size-fractionated at 0.45 micrometers (µm), 0.22 µm, and 0.02 µm to distinguish particulate (>0.45 µm), colloidal (0.22–0.02 µm), and dissolved (<0.02 µm) fractions. The data package consists of comma-separated value (.csv) files containing tabulated chemical concentration data, sample metadata (site identifiers, geographic coordinates, sampling dates, fraction type), and quality control flags. All files are provided in open, non-proprietary formats that can be accessed using standard data analysis software such as Microsoft Excel, R, Python, MATLAB, or other programs capable of reading .csv files. Units, detection limits, and analytical methods are documented in accompanying metadata files. The dataset is designed to support analyses of (1) how beaver impoundment and restoration structures alter elemental partitioning and transport, (2) the role of iron and organic carbon in mediating trace metal mobility, and (3) reach-scale changes in water quality across restoration gradients. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231. Part of this work was performed at SLAC Accelerator Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-76SF00515.

Anions↗

C++ Tensor Toolbox User Manual (V.1.0)

The C++ Tensor Toolbox is a software package for computing tensor decompositions. It is based on the Matlab Tensor Toolbox, and is particularly optimized for sparse data sets. This user manual briefly overviews tensor decomposition mathematics, software capabilities, and installation of the package. Tensors (also known as multidimensional arrays or N-way arrays) are used in a variety of applications ranging from chemometrics to network analysis. The Tensor Toolbox provides classes for manipulating dense, sparse, and structured tensors in C++. The Toolbox compiles into libraries and is intended for use with custom applications written by users.

99 GENERAL AND MISCELLANEOUS↗

SHMTools: Structural Health Monitoring Software for Aerospace, Civil, and Mechanical Infrastructure

Structural Health Monitoring (SHM) involves a multitude of processes designed to detect damage in situ on various types of structures, from aircraft and buildings to bridges and mechanical infrastructure. In an early example of SHM, railroad wheeltappers used a hammer to strike train wheels to determine if there was damage present. At Los Alamos, scientists have developed SHMTools, a software suite that provides more than 100 advanced algorithms that quickly prototype and evaluate damage-detection processes. The software consists of modular MATLAB routines covering the three main stages of SHM: data acquisition, feature extraction, and feature classification. Multiple sensing modalities are supported, including acceleration, strain, and guided-wave data, all of which have been widely used in SHM practice.

42 ENGINEERING↗