Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Magnetic source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Twin-pulse seeding enables pump-probe capabilities in the EUV to soft X-ray spectrum at synchrotron light sources

Having previously reported that separating the two stages of echo-enabled harmonic generation (EEHG) with one or more bending magnet (BM) sections allows the BMs to serve as the desired source of momentum compaction, here we demonstrate that this arrangement can greatly reduce the total energy modulation required by any 4th generation synchrotron light source, leading to higher repetition rates as well as stronger coherent radiation output power, with significant benefits. Since the EEHG beamline performance is mainly determined by the momentum compaction, beam emittances and beta functions of a storage ring lattice, allowing for different separations between the two stages is a straightforward way to increase the momentum compaction of chicane 1. This also enables pump-probe capabilities in a novel context, where twin-pulse seeding on the same electron bunch would allow two distinct radiation pulses with an adjustable delay in the range of 0.1 to 10 ps. In the twin-pulse seeding scheme, the same electron bunch could undergo modulation from two distinct laser pulses. Later stages would produce independent harmonics in subsequent straight sections. There are two variations of this twin-pulse seeding scheme, supporting different scientific applications. With a common modulation in stage 1, the first option allows simultaneously two independent radiation sources, with a full coverage of the EUV (2.5 to 50 nm) to soft X-ray (1.25 to 2.5 nm) spectrum; for the second option, the same stage 2 undulator could generate two coherent pulses both fitting within the FEL bandwidth, or at distinct harmonics. We present particle tracking simulation studies based on the APS-U lattice, including quantum excitation and radiation damping. These simulations indicate that there is no degradation of the modulated longitudinal phase space even when the two stages are separated by as many as 10 BM sections.

36 MATERIALS SCIENCE↗

Magnetic pair distribution function data using polarized neutrons and ad hoc corrections

Here, we report the first example of magnetic pair distribution function (mPDF) data obtained through the use of neutron polarization analysis. Using the antiferromagnetic semiconductor MnTe as a test case, we present high-quality mPDF data collected on the HYSPEC instrument at the Spallation Neutron Source using longitudinal polarization analysis to isolate the magnetic scattering cross section. Clean mPDF patterns are obtained for MnTe in both the magnetically ordered state and the correlated paramagnet state, where only short-range magnetic order is present. We also demonstrate significant improvement in the quality of high-resolution mPDF data through the application of ad hoc corrections that require only minimal human input, minimizing potential sources of error in the data processing procedure. We briefly discuss the current limitations and future outlook of mPDF analysis using polarized neutrons. Overall, this work provides a useful benchmark for mPDF analysis using polarized neutrons and provides an encouraging picture of the potential for routine collection of high-quality mPDF data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Heat Diffusion in High-Cp Nb3Sn Composite Superconducting Wires

A major focus of Nb3Sn accelerator magnets is on significantly reducing or eliminating their training. Demonstration of an approach to increase the Cp of Nb3Sn magnets using new materials and technologies is very important both for particle accelerators and light sources. It would improve thermal stability and lead to much shorter magnet training, with substantial savings in machines’ commissioning costs. Both Hypertech and Bruker-OST have attempted to introduce high-Cp elements in their wire design. This paper includes a description of these advanced wires, the finite element model of their heat diffusion properties as compared with the standard wires, and whenever available, a comparison between the minimum quench energy (MQE) calculated by the model and actual MQE measurements on wires.

43 PARTICLE ACCELERATORS↗

Characterization of Self-Magnetic Pinch (SMP) radiographic diode performance on RITS-6 at Sandia National Laboratories: 1) Diode Dynamics, DC Heating to extend Radiation Pulse

Radiographic diodes focus an intense electron beam to a small spot size to minimize the source area of energetic photons for radiographic interrogation. The self-magnetic pinch (SMP) diode has been developed as such a source and operated as a load for the RITS-6 Inductive Voltage Adder (IVA) driver. While experiments support the generally accepted conclusion that a 1:1 aspect diode (cathode diameter equals anode-cathode gap) delivers optimum SMP performance, such experiments also show that reducing the cathode diameter, while reducing spot size, also results in reduced radiation dose, by as much as 50%, and degraded shot reproducibility. Analyzation of the effective electron impingement angle on the anode converter with time made possible by a newly developed dose-rate array diagnostic indicates that fast-developing oscillations of the angle are correlated with early termination of the radiation pulse on many of the smaller-diameter SMP shots. This behavior as a function of relative cathode size persists through experiments with output voltages and currents up to 11.5 MV and 225 kA, respectively, and with spot sizes below ~ few mm. Since simulations to date have not predicted such oscillatory behavior, considerable discussion of the angle-behavior of SMP shots is made to lend credence to the inference. There is clear anecdotal evidence that DC heating of the SMP diode region leads to stabilization of this oscillatory behavior. This is the first of two papers on the performance of the SMP diode on the RITS-6 accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of self-magnetic pinch (SMP) radiographic diode performance on RITS-6 at Sandia National Laboratories. I. Diode dynamics, DC heating to extend radiation pulse

Radiographic diodes focus on an intense electron beam to a small spot size to minimize the source area of energetic photons for radiographic interrogation. The self-magnetic pinch (SMP) diode has been developed as such a source and operated as a load for the six-cavity radiographic integrated test stand (RITS-6) inductive voltage adder driver. While experiments support the generally accepted conclusion that a 1:1 aspect diode (cathode diameter equals anode–cathode gap) delivers optimum SMP performance, such experiments also show that reducing the cathode diameter, while reducing spot size, also results in reduced radiation dose, by as much as 50%, and degraded shot reproducibility. Analysis of the effective electron impingement angle on the anode converter with time made possible by a newly developed dose-rate array diagnostic indicates that fast-developing oscillations of the angle are correlated with early termination of the radiation pulse on many of the smaller-diameter SMP shots. This behavior as a function of relative cathode size persists through experiments with output voltages and currents up to 11.5 MV and 225 kA, respectively, and with spot sizes below approximately few millimeters. Since simulations to date have not predicted such oscillatory behavior, considerable discussion of the angle behavior of SMP shots is made to lend credence to the inference. We report there is clear anecdotal evidence that DC heating of the SMP diode region leads to stabilization of this oscillatory behavior. This is the first of two papers on the performance of the SMP diode on the RITS-6 accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status of the MQXFB Nb 3 Sn Quadrupoles for the HL-LHC

Here, the cold powering test of the first two prototypes of the MQXFB quadrupoles (MQXFBP1, now disassembled, and MQXFBP2), the Nb 3 Sn inner triplet magnets to be installed in the HL-LHC, has validated many features of the design, such as field quality and quench protection, but has found performance limitations. In fact, both magnets showed a similar phenomenology, characterized by reproducible quenches in the straight part inner layer pole turn, with absence of training and limiting the performance at 93% (MQXFBP1) and 98% (MQXFBP2) of the nominal current at 1.9 K, required for HL-LHC operation at 7 TeV. Microstructural inspections of the quenching section of the limiting coil in MQXFBP1 have identified fractured Nb 3 Sn sub-elements in strands located at one specific position of the inner layer pole turn, allowing to determine the precise origin of the performance limitation. In this paper we outline the strategy that has been defined to address the possible sources of performance limitation, namely coil manufacturing, magnet assembly and integration in the cold mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Inelastic Neutron Scattering Data for Ba₃Zn(Ru₀.₁Sb₁.₉)O₉

This dataset contains inelastic neutron scattering measurements on the magnetically dilute compound Ba₃Zn(Ru₀.₁Sb₁.₉)O₉, collected at the Spallation Neutron Source using the Cold Neutron Chopper Spectrometer (CNCS) and the SEQUOIA Fine-Resolution Fermi Chopper Spectrometer. The sample consists of nominally 5% magnetic Ru⁵⁺ ions (S = 3/2) randomly substituted into a diamagnetic Sb⁵⁺ matrix. Measurements were performed at base temperature (2–5 K) and 300 K using multiple incident energies (1.00, 3.32, 12.0, and 100 meV) to resolve magnetic excitations from isolated monomers and small Ru clusters (dimers, trimers, etc.). The dataset includes raw event-mode files, momentum- and energy-resolved spectra, and supporting metadata for instrument configuration, sample environment, and reduction parameters.

36 MATERIALS SCIENCE↗

Probing Phase Transitions and Magnetism in Minerals with Neutrons

We report the development of sophisticated sample environments to control temperature, pressure, and magnetic field has grown in parallel with neutron source and instrumentation development. High-pressure apparatus, with high- and low-temperature capability, novel designs for diamond cells, and large volume presses are matched with next-generation neutron sources and moderator designs to provide unprecedented neutron beam brightness. Recent developments in sample environments are expanding the pressure–temperature space accessible to neutron scattering experiments. Researchers are using new capabilities and an increased understanding of the fundamentals of structural and magnetic transitions to explore new territories, including hydrogenous minerals (e.g., ices and hydrates) and magnetic structural phase diagrams.

58 GEOSCIENCES↗

Optically pumped polarized 3 He ++ ion source development for RHIC/EIC

The proposed polarized 3 He ++ acceleration in RHIC and the future Electron-Ion Collider will require about 2×10 11 ions in the source pulse. A new technique had been proposed for production of high intensity polarized 3 He ++ ion beams. It is based on ionization and accumulation of the 3 He gas (polarized by metastability-exchange optical pumping and in the 5T high magnetic field) in the existing Electron Beam Ion Source (EBIS). A novel 3 He cryogenic purification and storage technique was developed to provide the required gas purity. An original gas refill and polarized 3 He gas injection to the EBIS long drift tubes, (which serves as the storage cell) were developed to ensure polarization preservation. An infrared laser system for optical pumping and polarization measurements in the high 3–5 T field has been developed. The 3 He polarization 80–85% (and sufficiently long ~30 min relaxation time) was obtained in the “open” cell configuration with refilling valve tube inlet and isolation valve closed. The development of the spin-rotator and 3 He 4 He absolute nuclear polarimeter at 6 MeV 3 He ++ beam energy is also presented here in this work.

43 PARTICLE ACCELERATORS↗

Absolute decay counting of 146 Sm with 4π cryogenic microcalorimetry

We present a methodology for absolute activity counting of long-lived isotopes based on cryogenic Decay Energy Spectroscopy. A 146 Sm source was produced at the TRIUMF Laboratory and then processed and purified at Lawrence Livermore National Laboratory, yielding a pure sample. The source was embedded within a 4π thermal absorber coupled to a magnetic microcalorimeter achieving nearly 100% counting efficiency. Experimental uncertainties were studied and modeled, including thermal coupling of the source to the absorber, pulse pile-up, trigger, and event selection efficiencies. Here, the absolute activity of the pure 146 Sm source was measured to better than 1% uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved high-gradient performance for medium-velocity superconducting half-wave resonators: Surface preparation and trapped flux mitigation

A development effort to improve the performance of superconducting radio-frequency half-wave resonators (SRF HWRs) is underway at the Facility for Rare Isotope Beams (FRIB), where 220 such resonators are in operation. Our goal was to achieve an intrinsic quality factor (𝑄 0 ) of ≥ 2 × 10 10 at an accelerating gradient (𝐸 acc ) of 12 MV/m. FRIB production resonators were prepared with buffered chemical polishing. First trials of electropolishing (EP) and post-EP low-temperature baking of FRIB HWRs allowed us to reach higher gradient (15 MV/m, limited by quench) with a higher quality factor at high gradient, but 𝑄 0 was still below our goal. Trapped magnetic flux during the Dewar test was found to be a source of 𝑄 0 reduction. Three strategies were used to reduce the trapped flux: (i) adding a local magnetic shield (LMGS) to supplement the “global” magnetic shield around the Dewar for reduction of the ambient magnetic field; (ii) performing a “uniform cooldown” (UC) to reduce the thermoelectric currents; and (iii) using a compensation coil to further reduce the ambient field with active field cancellation (AFC). The LMGS improved the 𝑄 0 , but not enough to reach our goal. With UC and AFC, we exceeded our goal, reaching 𝑄 0 = 2.8 ×10 10 at 𝐸 acc = 12 MV/m.

Cryogenics & vacuum technology↗

Off-state magnetoresistance in long-channel germanium Schottky-barrier MOSFETs

An increasing magnetic field perpendicular to an undoped semiconductor surface at low temperature is known to strengthen the binding of localized electrons to stationary ions, as the wavefunction's tails evolve from exponential to Gaussian. It is also known that application of a high bias voltage to a depleted semiconductor can liberate bound charge and induce a large drop in electrical resistance. We connect these established results to experimental electrical transport measurements on off-state germanium Schottky-barrier metal–oxide–semiconductor field-effect transistor (MOSFETs) with an aluminum oxide insulating dielectric and platinum germanide contacts. We make measurements at the three distinct orientations of the magnetic field with respect to the substrate and the current. At 6 K, we observe sharp attenuation of current by more than 2 orders of magnitude, within 60 mT, at a crossover magnetic field perpendicular to the substrate. A 1 T magnetic field attenuates the current by more than 4 orders of magnitude. The strength of the attenuation and the value of the crossover field are controlled by both the gate–source and drain–source voltages. The attenuation is much weaker when the magnetic field is parallel to the current. Finally, we orient the magnetic field parallel to the substrate, but perpendicular to the current, allowing us to distinguish charge hopping at the oxide interface from charge hopping in the bulk. In conclusion, this large off-state magnetoresistance can be exploited for cryogenic magnetic- and photo-detection, and for high-bias, low-leakage MOSFETs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electronic commensuration of a spin moiré superlattice in a layered magnetic semimetal

Spin moiré superlattices (SMSs) have been proposed as a magnetic analog of crystallographic moiré systems and a source of electron minibands offering vector-field moiré tunability and Berry curvature effects. However, it has proven challenging to realize an SMS in which a large exchange coupling J is transmitted between conduction electrons and localized spins. Furthermore, most systems have carrier mean free paths l mfp shorter than their spin moiré lattice constant a spin , inhibiting miniband formation. Here, we discover that the layered magnetic semimetal EuAg 4 Sb 2 overcomes these challenges by forming an interface with J ~ 100 milli–electron volts transferred between a Eu triangular lattice and anionic Ag 2 Sb bilayers hosting a two-dimensional electron band in the ballistic regime (l mfp >> a spin ). The system realizes an SMS with a spin commensurate with the Fermi momentum, leading to a marked quenching of the transport response from miniband formation. Our findings demonstrate an approach to magnetically engineering moiré superlattices and a potential route to an emergent spin-driven quantum Hall state.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of hot-spots due to trapped flux in niobium superconducting radiofrequency cavities

One of the significant sources of residual losses in superconducting radio-frequency cavities is magnetic flux trapped during the cool-down due to the incomplete Messier effect. If the trapped vortices are non-uniformly distributed on the cavity surface, the temperature mapping revealed the “hotspots” at the location of high density of pinned vortices. Here, we performed a rf test on 1.3 GHz single cell cavity with the combination of the temperature mapping system. The temperature mapping reveled the development of the hot spots with the increase in rf field inside the cavity. When magnetic field is trapped locally on the surface of cavity, the hot-spots strength increase rapidly, showing the direct correlation of vortex induced hot spot and corresponding rf loss.

Accelerator Physics↗

Sensitivity of the GAPS experiment to low-energy cosmic-ray antiprotons

The General Antiparticle Spectrometer (GAPS) is an upcoming balloon mission to measure low-energy cosmic-ray antinuclei during at least three ~35-day Antarctic flights. With its large geometric acceptance and novel exotic atom-based particle identification, GAPS will detect ~500 cosmic antiprotons per flight and produce a precision cosmic antiproton spectrum in the kinetic energy range of ~0.07–0.21 GeV/n at the top of the atmosphere. With these high statistics extending to lower energies than any previous experiment, and with complementary sources of experimental uncertainty compared to traditional magnetic spectrometers, the GAPS antiproton measurement will be sensitive to dark matter, primordial black holes, and cosmic ray propagation. The antiproton measurement will also validate the GAPS antinucleus identification technique for the antideuteron and antihelium rare-event searches. Finally, this analysis demonstrates the GAPS sensitivity to cosmic-ray antiprotons using a full instrument simulation and event reconstruction, and including solar and atmospheric effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Global Images of Ion Energization in the Terrestrial Foreshock by the Interstellar Boundary Explorer

The Interstellar Boundary Explorer (IBEX) mission provides global energetic neutral atom (ENA) observations from the heliosphere and the Earth's magnetosphere, including spatial, temporal, and energy information. IBEX views the magnetosphere from the sides and almost always perpendicular to noon-midnight plane. We report the first ENA images of the energization process in the Earth's ion foreshock and magnetosheath regions. We show ENA flux and spectral images of the dayside magnetosphere with significant energization of ENA plasma sources (above ~2.7 keV) in the region magnetically connected to the Earth's bow shock (BS) in its quasi-parallel configuration of the interplanetary magnetic field (IMF). We also show that the ion energization increases gradually with decreasing IMF-BS angle, suggesting more efficient suprathermal ion acceleration deeper in the quasi-parallel foreshock.

79 ASTRONOMY AND ASTROPHYSICS↗

Hints of primordial magnetic fields at recombination and implications for the Hubble tension

Primordial Magnetic Fields (PMFs), long studied as relics of the early Universe, accelerate recombination and have been proposed as a way to relieve the Hubble tension. However, previous studies relied on simplified toy models. Here, in this study, we use recent evaluations of recombination with PMFs, incorporating full magnetohydrodynamic (MHD) simulations and detailed Lyman-alpha radiative transfer, to test PMF-enhanced recombination (bΛCDM) against observational data from the cosmic microwave background (CMB), baryon acoustic oscillations (BAO), and Type Ia supernovae (SN). Focusing on non-helical PMFs with a Batchelor spectrum, we find a preference for presentday total field strengths of approximately 5-10 pico-Gauss. Depending on the dataset combination, this preference ranges from mild (∼ 1.8σ with Planck + DESI) to moderate (∼ 3σ with Planck + DESI + SH0ES-calibrated SN) significance. The bΛCDM has Planck + DESI χ 2 values equal to or better than ΛCDM while predicting a higher Hubble constant. Future high-resolution CMB temperature and polarization measurements will be crucial for confirming or further constraining PMFs at recombination. Field strengths of 5-10 pico-Gauss align closely with those required for cluster magnetic fields to originate entirely from primordial sources, without the need for additional dynamo amplification.

Jedamzik, Karsten [Centre National de la Recherche↗

Spin current generation and detection in uniaxial antiferromagnetic insulators

Spin current represents a flow of spin angular momentum and does not require movement of charges. Magnetic insulators can therefore work as a source as well as a medium of spin currents, which has been established in ferrimagnetic insulators. Here, we report recent progress in the generation and electrical detection of spin currents in uniaxial antiferromagnetic insulators carried by antiferromagnetic magnons, both thermally and resonantly excited, respectively, via the spin Seebeck effect and antiferromagnetic spin pumping by subterahertz microwaves. These findings open up many exciting possibilities of potential antiferromagnetic applications.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗