Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Magnetic Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Direct evidence of microstructure dependence of magnetic flux trapping in niobium

Abstract Elemental type-II superconducting niobium is the material of choice for superconducting radiofrequency cavities used in modern particle accelerators, light sources, detectors, sensors, and quantum computing architecture. An essential challenge to increasing energy efficiency in rf applications is the power dissipation due to residual magnetic field that is trapped during the cool down process due to incomplete magnetic field expulsion. New SRF cavity processing recipes that use surface doping techniques have significantly increased their cryogenic efficiency. However, the performance of SRF Nb accelerators still shows vulnerability to a trapped magnetic field. In this manuscript, we report the observation of a direct link between flux trapping and incomplete flux expulsion with spatial variations in microstructure within the niobium. Fine-grain recrystallized microstructure with an average grain size of 10–50 µm leads to flux trapping even with a lack of dislocation structures in grain interiors. Larger grain sizes beyond 100–400 µm do not lead to preferential flux trapping, as observed directly by magneto-optical imaging. While local magnetic flux variations imaged by magneto-optics provide clarity on a microstructure level, bulk variations are also indicated by variations in pinning force curves with sequential heat treatment studies. The key results indicate that complete control of the niobium microstructure will help produce higher performance superconducting resonators with reduced rf losses 1 related to the magnetic flux trapping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultrasonic waveguide reflectometry for quench detection (CRADA Final Report)

Early detection of thermal runaway (quench) is critical for safely operating high-temperature superconductor (HTS) magnets. Voltage-based techniques provide late detection of quenching in HTS, which can lead to magnet burnout and system damage. Various non-voltage quench-detection approaches are therefore investigated nowadays that are based on magnetic, acoustic, and optical sensing. LBNL has been actively developing the quench detection principle based on diffuse ultrasonic wave propagation since 2017 and has demonstrated the approach's viability with several peer-reviewed publications and a patent application. Over the last decade, Etegent, LBNL partner for this proposal and effort, has been developing a sensing technology that utilizes the propagation of stress waves through the solid metallic and nonmetallic waveguides (WG). The method is based on the dependence of materials' elastic properties and the speed of sound on temperature. Compared with optical analog, acoustic WG operates at much lower frequencies, eliminating the need for expensive, complex, highly sensitive receivers and data processing. Etegent proved this technology in many harsh environments, mainly concentrated high-temperature measurements. The initial contact between LBNL and Etegent started in 2020, aiming at combining our knowledge and effort toward developing a viable ultrasound-based quench detection technique for use with HTS magnets. A preliminary study conducted jointly in 2022 found no principle restrictions for expanding the WG technology toward cryogenic temperature operation. The present CRADA work aimed at designing, building, and testing ultrasonic waveguide temperature sensors at relevant cryogenic conditions, and demonstrating this technology's applicability to detecting heating and quenching in High Temperature Superconductor (HTS)-based cables and magnets. The technical objectives of the project included: (1) Design and fabricate ultrasonic WG sensors suitable for cryogenic operation, (2) Test ultrasonic WGs under cryogenic conditions, (3) Determining a suitable way of insulating WGs to prevent ultrasonic leakage while maintaining good thermal contact with the surrounding medium, (4) WG integration and cryogenic test with HTS conductors and HTS magnets, and (5) Design and basic prototyping of a standalone WG-based quench detection system. This project adds value to the present LBNL magnet diagnostics portfolio and enables a breakthrough in addressing the HTS magnet quench detection challenge.

47 OTHER INSTRUMENTATION↗

Detection and Aggregation of Listeria Monocytogenes Using Polyclonal Antibody Gold-Coated Magnetic Nanoshells Surface-Enhanced Raman Spectroscopy Substrates

Magnetic nanoshells with tailored surface chemistry can enhance bacterial detection and separation technologies. This work demonstrated a simple technique to detect, capture, and aggregate bacteria with the aid of end-functionalized polyclonal antibody gold-coated magnetic nanoshells (pAb-Lis-AuMNs) as surface-enhanced Raman spectroscopy (SERS) probes. Listeria monocytogenes were used as the pathogenic bacteria and the pAb-LisAuMNs, 300 nm diameter, were used as probes allowing facile magnetic separation and aggregation. An optimized covalent bioconjugation procedure between the magnetic nanoshells and the polyclonal antibody was performed at pH six via a carbodiimide crosslinking reaction. Spectroscopic and morphological characterization techniques confirmed the fabrication of stable pAb-Lis-AuMNs. The resulting pAb-Lis-AuMNs acted as a SERS probe for L. monocytogenes based on the targeted capture via surface binding interactions and magnetically induced aggregation. Label-free SERS measurements were recorded for the minimum detectable amount of L. monocytogenes based on the SERS intensity at the 1388 cm -1 Raman shift. L. monocytogenes concentrations exhibited detection limits in the range of 10 4 –10 7 CFU ml -1 , before and after aggregation. By fitting these concentrations, the limit of detection of this method was ~10 3 CFU ml -1 . Using a low-intensity magnetic field of 35 G, pAb-LisAuMNs aggregated L. monocytogenes as demonstrated with microscopy techniques, including SEM and optical microscopy. Overall, this work presents a label-free SERS probe method comprised of a surface-modified polyclonal antibody sub-micron magnetic nanoshell structures with high sensitivity and magnetic induced separation that could lead to the fabrication of multiple single-step sensors.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Quantum Logic Enhanced Sensing in Solid-State Spin Ensembles

We demonstrate quantum logic enhanced sensitivity for a macroscopic ensemble of solid-state, hybrid two-qubit sensors. We achieve over a factor of 30 improvement in the single-shot signal-to-noise ratio, translating to an ac magnetic field sensitivity enhancement exceeding an order of magnitude for time-averaged measurements. Using the electronic spins of nitrogen vacancy (NV) centers in diamond as sensors, we leverage the on-site nitrogen nuclear spins of the NV centers as memory qubits, in combination with homogeneous and stable bias and control fields, ensuring that all of the ~10 9 two-qubit sensors are sufficiently identical to permit global control of the NV ensemble spin states. We find quantum logic sensitivity enhancement for multiple measurement protocols with varying optimal sensing intervals, including XY8 and DROID-60 dynamical decoupling, as well as correlation spectroscopy, using an applied ac magnetic field signal. The results are independent of the nature of the target signal and broadly applicable to measurements using NV centers and other solid-state spin ensembles. Furthermore, this work provides a benchmark for macroscopic ensembles of quantum sensors that employ quantum logic or quantum error correction algorithms for enhanced sensitivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic Navigation for GPS-Denied Airborne Applications

Most current flight systems are dependent on GPS for navigation. Recently, however, navigation in GPS-denied environments has become an area of intensive research. Additional navigation sensor data can be obtained from visual observations (stars or terrain), inertial measurement units, radar, measurements of the local magnetic field, or perhaps even gravity. Absolute and relative positioning via magnetic field measurements have been shown to be viable in many applications including ground navigation, low altitude aircraft flight, and spaceflight. There is greater variability in the magnetic field over shorter distances when flying at low altitude and in ground applications, leading to more accurate positioning. However, ground-based magnetic navigation is often heavily influenced by man-made structures, especially in urban environments. This is not the case for airborne magnetic navigation since the influence of buildings, roads, etc. is negligible for typical aircraft altitudes. For absolute magnetic navigation, the positioning accuracy decreases as altitude increases for a given vehicle velocity, but the observed time variability in the field can be reclaimed by traveling faster through the field. Thus, navigation accuracy becomes a balance of speed and altitude since the higher altitude can be counterbalanced by higher velocity. To understand these effects quantitatively, we explored various techniques to aid a simulated inertial measurement unit with magnetic information. Using a technique known as two-dimensional magnetic map matching, we simulated the performance of airborne magnetic navigation at fixed speed while varying the altitude, flight direction, magnetometer data collection time, reference magnetic map bias error, and type of trajectory (over land or over ocean).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low-symmetry vacancy-related spin qubit in hexagonal boron nitride

Abstract Point defect qubits in semiconductors have demonstrated their outstanding capabilities for high spatial resolution sensing generating broad multidisciplinary interest. Hexagonal boron nitride (hBN) hosting point defect qubits have recently opened up new horizons for quantum sensing by implementing sensing foils. The sensitivity of point defect sensors in hBN is currently limited by the linewidth of the magnetic resonance signal, which is broadened due to strong hyperfine couplings. Here, we report on a vacancy-related spin qubit with an inherently low symmetry configuration, the VB2 center, giving rise to a reduced magnetic resonance linewidth at zero magnetic fields. The VB2 center is also equipped with a classical memory that can be utilized for storing population information. Using scanning transmission electron microscopy imaging, we confirm the existence of the VB2 configuration in free-standing monolayer hBN.

Chemistry↗

Characterization of Soil and Rock Magnetic Properties along Multiple Hillslope Transects at Teller Road Site, Seward Peninsula, Alaska, 2018 and 2023

The magnetometer data was collected in multiple directions across the watershed hillslope at the NGEE Arctic Teller Road site at mile marker 27 (TL_MM27) on the Seward Peninsula, Alaska over multiple years in March 2018 and April 2023. The magnetic data were collected using a Geometrics Inc. G-858 gradiometer and G-857 base station in 2018 and the G-864 gradiometer and G857 base station in 2023. The data was collected (in all instances) by towing the gradiometer behind a snow machine around the watershed with the two sensors in a vertical profile with constant spacing during the continuous survey in that specific year. Magnetic total field measurements were collected by gradiometer and base station, and the data processing was performed in Geometrics MagMap2000 software. The processing steps were limited to removal of data spikes (despiking), reading dropouts, and correction/removal of bad GPS points. All offsets between sensors and GPS are stated within the data files and metadata, alongwith the processed and raw data. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).In this data submission there are two sets of raw magnetic data (.bin and .stn for 2018 and base for 2023; raw rover mag for 2023 is in .csv) inside two .zip files that identify the year the mag data was collected. The data are proprietary format to Geometrics and can be opened and processed with MagMap2000 which can be downloaded for free at Geometrics website. There are also two processed data files *.csv for each year and two metadata files *.csv.

54 ENVIRONMENTAL SCIENCES↗

The CMS Magnetic Field Measuring and Monitoring Systems

This review article describes the performance of the magnetic field measuring and monitoring systems for the Compact Muon Solenoid (CMS) detector. To cross-check the magnetic flux distribution obtained with the CMS magnet model, four systems for measuring the magnetic flux density in the detector volume were used. The magnetic induction inside the 6 m diameter superconducting solenoid was measured and is currently monitored by four nuclear magnetic resonance (NMR) probes installed using special tubes outside the barrel hadron calorimeter. Two more NRM probes were installed at the faces of the tracking system. The field inside the superconducting solenoid was precisely measured in 2006 in a cylindrical volume of 3.448 m in diameter and 7 m in length using 10 three-dimensional (3D) B-sensors based on the Hall effect. These B-sensors were installed on each of the two propeller arms of an automated field-mapping machine. In addition to these measurement systems, a system for monitoring the magnetic field during the CMS detector operation has been developed. Inside the solenoid in the horizontal plane, 4 3D B-sensors were installed at the faces of the tracking detector. Twelve 3D B-sensors were installed on the surfaces of the flux-return yoke nose disks. Seventy 3D B-sensors were installed in the air gaps of the CMS magnet yoke. A specially developed flux loop technique was used for the most complex measurements of the magnetic flux density inside the steel blocks of the CMS magnet yoke. The flux loops are installed in 22 sections of the flux-return yoke blocks. The areas enclosed by these coils varied from 0.3 to 1.59 m$^{2}$ in the blocks of the barrel wheels and from 0.5 to 1.12 m$^{2}$ in the blocks of the yoke endcap disks. The development of these systems and the results of the magnetic flux density measurements across the CMS magnet are presented and discussed in this review article.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Signatures of fractional quantum anomalous Hall states in twisted MoTe 2

The interplay between spontaneous symmetry breaking and topology can result in exotic quantum states of matter. A celebrated example is the quantum anomalous Hall (QAH) state, which exhibits an integer quantum Hall effect at zero magnetic field owing to intrinsic ferromagnetism. In the presence of strong electron–electron interactions, fractional QAH (FQAH) states at zero magnetic field can emerge. These states could host fractional excitations, including non-Abelian anyons—crucial building blocks for topological quantum computation9. Here we report experimental signatures of FQAH states in a twisted molybdenum ditelluride (MoTe 2 ) bilayer. Magnetic circular dichroism measurements reveal robust ferromagnetic states at fractionally hole-filled moiré minibands. Using trion photoluminescence as a sensor, we obtain a Landau fan diagram showing linear shifts in carrier densities corresponding to filling factor v = −2/3 and v = −3/5 ferromagnetic states with applied magnetic field. These shifts match the Streda formula dispersion of FQAH states with fractionally quantized Hall conductance of ${\sigma }_{xy}=-\,\frac{2}{3}\frac{{e}^{2}}{h}$ and ${\sigma }_{xy}=-\,\frac{3}{5}\frac{{e}^{2}}{h}$ , respectively. Moreover, the v = −1 state exhibits a dispersion corresponding to Chern number −1, consistent with the predicted QAH state. In comparison, several non-ferromagnetic states on the electron-doping side do not disperse, that is, they are trivial correlated insulators. The observed topological states can be electrically driven into topologically trivial states. Our findings provide evidence of the long-sought FQAH states, demonstrating MoTe 2 moiré superlattices as a platform for exploring fractional excitations.

Quantum Hall↗

Scanning SQUID microscopy in a cryogen-free dilution refrigerator

We report a scanning superconducting quantum interference device (SQUID) microscope in a cryogen-free dilution refrigerator with a base temperature at the sample stage of at least 30 mK. The microscope is rigidly mounted to the mixing chamber plate to optimize thermal anchoring of the sample. The microscope housing fits into the bore of a superconducting vector magnet, and our design accommodates a large number of wires connecting the sample and sensor. Through a combination of vibration isolation in the cryostat and a rigid microscope housing, we achieve relative vibrations between the SQUID and the sample that allow us to image with micrometer resolution over a 150 μm range while the sample stage temperature remains at base temperature. To demonstrate the capabilities of our system, we show images acquired simultaneously of the static magnetic field, magnetic susceptibility, and magnetic fields produced by a current above a superconducting micrometer-scale device.

47 OTHER INSTRUMENTATION↗

Test of Harmonic Coil Accuracy Using a Multi Vertex Probe

Magnets are integral components of particle accelerators, with different multipoles used to perform various beam conditioning functions, like steering and focusing. Testing accelerator magnets to ensure compliance with specification is a crucial step of fabrication. One of the most popular techniques for verifying magnetic field strength and integrity is the harmonic coil probe. Harmonic coil probes are comprised of passive loops that are rotated around the aperture of a magnet and are used to measure magnetic flux. Oftentimes the measurements of the harmonic coil probe are affected by transverse vibrations along the axis of rotation and torsional vibrations of the position closure sensor, both causing spurious harmonics. To make matters challenging, it is difficult to distinguish between the real harmonics of the magnet and the spurious harmonics during analysis. This research explores the use of a novel configuration of harmonic coil probe, Multi-Vertex Probe (MVP), to address multiple factors that affect the accuracy and repeatability of harmonic coil probe measurement. Most of the results are based on simulation data, in which artificial torsional distortions are introduced and removed with the proposed processing method. In addition to implementing torsional vibration removal in simulation, laboratory analysis regarding the source of vibrations was performed using a pre-fabricated MVP. More specifically, various mechanical conditions were used to explore the standard deviation of main harmonic’s flux amplitude. The conditions included: coupling type (rigid or soft), rotation speed, probe starting position within magnetic field, and cabling location inside the magnetic field. Along with this, the MVP’s measured noise floor in and outside a magnetic field was quantified.

Lofquist, Claire [Northern Illinois U.]↗

The Simons Observatory: Magnetic Shielding Measurements for the Universal Multiplexing Module

The Simons Observatory (SO) includes four telescopes that will measure the temperature and polarization of the cosmic microwave background using over 60,000 highly sensitive transition-edge bolometers (TES). These multichroic TES bolometers are read out by a microwave RF SQUID multiplexing system with a multiplexing factor of 910. Given that both TESes and SQUIDs are susceptible to magnetic field pickup and that it is hard to predict how they will respond to such fields, it is important to characterize the magnetic response of these systems empirically. This information can then be used to limit spurious signals by informing magnetic shielding designs for the detectors and readout. This paper focuses on measurements of magnetic pickup with different magnetic shielding configurations for the SO universal multiplexing module (UMM), which contains the SQUIDs, associated resonators, and TES bias circuit. The magnetic pickup of a prototype UMM was tested under three shielding configurations: no shielding (copper packaging), aluminum packaging for the UMM, and a tin/lead-plated shield surrounding the entire dilution refrigerator 100 mK cold stage. We also present measurements of the pickup in the UMM when aluminum feedhorns are installed. The measurements show that the aluminum packaging outperforms the copper packaging by a shielding factor of 8-10, and adding the tin/lead-plated 1K shield further increases the relative shielding factor in the aluminum configuration by 1-2 orders of magnitude. Furthermore, the addition of feedhorns provides a factor of 30 improvement when the tin/lead shield is not installed and a factor of 5 improvement when it is.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low Temperature Microcalorimeters for Decay Energy Spectroscopy

Low Temperature Detectors have been used to measure embedded radioisotopes in a measurement mode known as Decay Energy Spectroscopy (DES) since 1992. DES microcalorimeter measurements have been used for applications ranging from neutrino mass measurements to metrology to measurements for safeguards and medical nuclides. While the low temperature detectors have extremely high intrinsic energy resolution (several times better than semiconductor detectors), the energy resolution achieved in practice is strongly dependent on factors such as sample preparation method. This review seeks to present the literature consensus on what has been learned by looking at the energy resolution as a function of various choices of detector, absorber, and sample preparation methods.

47 OTHER INSTRUMENTATION↗

Guided cold atom inertial sensors with membrane integrated photonics on atom trap integrated platforms

A guided cold-atom inertial sensor system comprises an atom trap integrated platform, a laser system, a magnetic field system, a control system, and a computing system. The laser system and magnetic field system are adapted to form a magneto-optical trap (MOT) about a suspended waveguide of the atom trap integrated platform made of membrane integrated photonics. After loading cold atoms from a MOT, the photonic atom trap integrated platform generates one-dimensional guided atoms with an evanescent field optical dipole trap (EF-ODT) along the optical waveguide to create guided atomic accelerometers/gyroscopes. Motion of atomic wavepackets in a superposition state is created along the guided atom geometry by way of state-dependent momentum kicks. The light-pulse sequence of guided atom interferometry splits, redirects, and recombines atomic wavepackets, which allows measurement of atom interference fringes sensitive to inertial forces via a probe laser.

Lee, Jongmin↗

Vibroacoustic Process Monitoring of 5-Stage Centrifugal Contactors

Vibroacoustic monitoring was investigated to aid in informing process operators with parameters regarding aqueous separation techniques. These techniques have a wide range of applications including nuclear fuel reprocessing. A small-scale solvent extraction system was set up with five magnetic drive contactors and two piston pumps to collect realistic operation. Vibration sensors were placed on three of the contactors and both pumps, and a microphone was placed near the system. Contactor rotational speed and pump flow rate were varied with known values to compare against measured vibroacoustic signatures. Spectral analysis allowed for the determination of contactor rotational speed and the ratio of organic to aqueous flow rate, an important parameter for ensuring optimal extraction. Vibration metrics such as kurtosis and crest factor provided additional details regarding individual rotational speeds and have potential in examination of faults for predictive maintenance. Overall, results indicate the capability of vibroacoustic monitoring to improve operator awareness and process outcomes.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In-field strain and temperature measurements in a (RE)Ba 2 Cu 3 O 7–x coil via Rayleigh-backscattering interrogated optical fibers

(RE)Ba 2 Cu 3 O 7-x (REBCO) conductors have overcome technical challenges related to manufacturing quality, length homogeneity, scale-up of piece-length, and joints. There is one remaining technical challenge, however, which is common to all high temperature superconductors and lies in effective detection of failure to prevent material degradation. An innovative technique based on optical fibers interrogated by Rayleigh backscattering has been shown to have advantages over voltage taps at detecting incipient faults. Prior work has experimentally demonstrated the technique in several implementation scenarios, including direct integration of optical fibers into superconducting conductors and cables to create a class of ‘SMART’ conductors and cables that are able to monitor their own health. In this paper, the magnet monitoring technique based on Rayleigh backscattering interrogated optical fibers has been experimentally studied in a model coil subject to external magnetic field, where different fiber integration methods are used to increase selectivity of the fiber sensor to temperature. Results show that the spectral shift displays different features during strain and thermal transients. The implications of the results in terms of potential and limitations of each sensor as well as strain-temperature decoupling are discussed.

36 MATERIALS SCIENCE↗

Nuclear quadrupole resonance spectroscopy with a femtotesla diamond magnetometer

Radio frequency (RF) magnetometers based on nitrogen vacancy centers in diamond are predicted to offer femtotesla sensitivity, but previous experiments were limited to the picotesla level. We demonstrate a femtotesla RF magnetometer using a diamond membrane inserted between ferrite flux concentrators. The device provides ~300-fold amplitude enhancement for RF magnetic fields from 70 kHz to 3.6 MHz, and the sensitivity reaches ~70 fT√s at 0.35 MHz. The sensor detected the 3.6-MHz nuclear quadrupole resonance (NQR) of room-temperature sodium nitrite powder. The sensor’s recovery time after an RF pulse is ~35 μs, limited by the excitation coil’s ring-down time. The sodium-nitrite NQR frequency shifts with temperature as -1.00±0.02 kHz/K, the magnetization dephasing time is T 2 *=887±51 μs, and multipulse sequences extend the signal lifetime to 332±23 ms, all consistent with coil-based studies. Our results expand the sensitivity frontier of diamond magnetometers to the femtotesla range, with potential applications in security, medical imaging, and materials science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mutual Inductance Level Sensor for Use in Liquid Metals

Electromagnetic instrumentation capable of measuring the level of liquid metal has been developed at Argonne National Laboratory’s (ANL) Mechanisms Engineering Test Loop (METL). The mutual inductance level sensor (MILS) utilizes the electromagnetic coupling between two coil conductors and a surrounding liquid metal to determine the level of the liquid metal. Mineral insulated cables wrapped on a stainless steel core provide a durable sensor construction. The use of a sealed stainless steel thimble isolates the sensor from the high-temperature liquid metal, allowing for easy sensor maintenance. Modern digital electronics allow for reliable and accurate operation of the sensor. Two sensor variations have been designed and fabricated, and the first variation has seen extensive testing in a non-sodium testing stand as well as in the high-temperature sodium environment of METL. Electromagnetic finite-element analysis studies have been performed using the COMSOL Magnetic Fields Solver. Regular operation of the MILS will commence following in-situ calibration of the sensors in the METL environment.

36 MATERIALS SCIENCE↗