Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROWAVES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

System and method for microwave volumetric additive manufacturing

The present disclosure relates to a volumetric additive manufacturing system for forming a structure from a volume of resin using microwave energy. The system makes use of an electronic controller and at least one beam forming algorithm accessible by the electronic controller for generating information relating to an amplitude and a time delay for forming a microwave signal, where the microwave signal will be used in irradiating a build volume, and where the build volume is formed by the volume of resin. A microwave signal generating subsystem is included which is responsive to the information generated by the beam forming algorithm, and which generates a microwave signal using the amplitude and the time delay determined by the beam forming algorithm. An antenna is used to receive the microwave signal and project the microwave signal as a microwave beam, in accordance with the amplitude and time delay, into the build volume to form the structure.

Mukherjee, Saptarshi↗

Higher Fe{sup 2+}/total Fe ratio in iron doped phosphate glass melted by microwave heating

Highlights: • Iron doped phosphate glasses prepared using microwave heating and conventional heating under air and reducing atmosphere. • Presence of iron predominantly in the ferrous oxidation state in all the glasses. • Significant concentrations of iron in the ferrous oxidation state on both octahedral and tetrahedral sites in all the glasses. • Ratio of Fe{sup 2+} with total iron is found higher in microwave prepared glasses in comparison to conventional prepared glasses. - Abstract: Iron doped phosphate glasses containing P{sub 2}O{sub 5}–MgO–ZnO–B{sub 2}O{sub 3}–Al{sub 2}O{sub 3} were melted using conventional resistance heating and microwave heating in air and under reducing atmosphere. All the glasses were characterised by UV–Vis–NIR spectroscopy, Mössbauer spectroscopy, thermogravimetric analysis and wet colorimetry analysis. Mössbauer spectroscopy revealed presence of iron predominantly in the ferrous oxidation state on two different sites in all the glasses. The intensity of the ferrous absorption peaks in UV–Vis–NIR spectrum was found to be more in glasses prepared using microwave radiation compared to the glasses prepared in a resistance heating furnace. Thermogravimetric analysis showed increasing weight gain on heating under oxygen atmosphere for glass corroborating higher ratio of FeO/(FeO + Fe{sub 2}O{sub 3}) in glass melted by direct microwave heating. Wet chemical analysis also substantiated the finding of higher ratio Fe{sup +2}/ΣFe in microwave melted glasses. It was found that iron redox ratio was highest in the glasses prepared in a microwave furnace under reducing atmosphere.

36 MATERIALS SCIENCE↗

A Scalable Readout for Microwave SQUID Multiplexing of Transition-Edge Sensors

The readout requirements for instruments based on transition-edge sensors (TESs) have dramatically increased over the last decade as demand for systems with larger arrays and faster sensors has grown. Emerging systems are expected to contain many thousands of sensors and/or sensors with time constants as short as 100 ms. These requirements must be satisfied while maintaining low noise, high dynamic range, and low crosstalk. A promising readout candidate for future TES arrays is the microwave SQUID multiplexer, which offers several gigahertz of readout bandwidth per pair of coaxial cables. In microwave SQUID multiplexing, sensor signals are coupled to RF-SQUIDs embedded in superconducting microwave resonators, which are probed via a common microwave feedline and read out using gigahertz signals. This form of SQUID multiplexing moves complexity from the cryogenic stages to room temperature hardware and digital signal processing firmware which must synthesize the microwave tones and process the information contained within them. To demultiplex signals from the microwave SQUID multiplexer, we have implemented an FPGA-based firmware architecture that is flexible enough to read out a variety of differently optimized TESs. A gamma-ray spectrometer targeted at nuclear materials accounting applications, known as SLEDGEHAMMER, is an early adopter of microwave SQUID multiplexing and is driving our current firmware development effort. This instrument utilizes 300 kHz full-width half-maximum resonators with 256 channels in a one gigahertz wide band. We have recently demonstrated undegraded readout of 128 channels using two ROACH2s on a single pair of coaxial cables. This manuscript describes the firmware implementation for the readout electronics of these early array-scale demonstrations.

42 ENGINEERING↗

A review of microwave-assisted process intensified multiphase reactors

Microwaves provide alternative heating and allow process intensification due to their rapid, volumetric, and selective nature. Recognizing the central role of multiphase reactors in chemical industry, a recent surge in employing microwaves is observed. We review the recent experimental and modeling investigations of microwave heating of multiphase reactors with emphasis on chemical engineering applications. Here we demonstrate that there is accumulated evidence for improved performance via microwave heating and a clear opportunity for further process intensification. In most of the cases, this improved performance stems from a temperature gradient between two phases. We discuss the ongoing debate on the mechanism by which microwaves affect chemical processes exacerbated by the inability of measuring the temperature distribution in a microwave cavity. We outline recent progress in this direction in monolith reactors and needs for future work. We underscore the lack of detailed modeling and simulation tools even for single-phase systems and emphasize the imperative for multiscale predictive modeling to bridge the experimental-modeling gap. Promising results are shown by a few recently published modeling studies that can predict the experimental measurements in complex multiphase reactors. A combination of experimental and modeling tools can provide a comprehensive picture of the microwave multiphase reactors as well as a means toward scale-up and optimization.

42 ENGINEERING↗

Dielectric and magnetic properties of microwave-absorbing FeAl x O y catalysts fabricated via solution combustion synthesis

Iron-based alumina (FeAl x O y ) nanocomposites are microwave-absorbers and catalysts, which makes them promising for emerging microwave-assisted thermocatalytic technologies. Solution combustion synthesis (SCS) has been used to synthesize FeAl x O y powders, and prior work has demonstrated that adjusting SCS parameters significantly changes phase composition and specific surface area of the products. However, it is unclear how synthesis parameters affect their microwave-absorbing properties, which are essential for optimizing microwave-assisted technologies. To address this challenge, in the present work, twelve different FeAl x O y products were synthesized at different combinations of the SCS parameters such as two fuels (citric acid and glycine), two heating modes (hotplate and muffle furnace), and three Fe:Al molar ratios (2:1, 1:1, 1:2). Dielectric and magnetic properties of the products were characterized using a network analyzer and a vibrating sample magnetometer. Based on the measured permittivity and permeability, penetration depth and reflection loss were calculated as a function of frequency and bed thickness. The products were heated by microwaves at 2.45 GHz and then examined with X-ray diffraction (XRD) analysis. For all products, the magnetic saturation was lower than for bulk iron oxides because of the small crystallite size and aluminum substitution. The use of glycine induced high dielectric losses and enabled fast microwave-heating rates compared to citric acid. Higher Fe:Al ratio also led to higher dielectric and magnetic losses. With glycine fuel, SCS in a furnace induced larger penetration depth and lower microwave absorption than SCS on a hotplate. The minimization of reflected power was more sensitive to the thickness of the product bed than to the frequency of the electromagnetic field. Post-heating XRD analysis revealed different phase transformations in the FeAl x O y powders depending on the SCS parameters. As a result, an FeAl x O y material, synthesized via incipient wetness impregnation, lacked magnetic losses and did not heat well as compared to the SCS products.

Combustion synthesis↗

Measurements of combustion properties in a microwave enhanced flame

Microwave induced flame speed enhancement is quantified in a laminar, premixed CH{sub 4}/air wall stagnation flat flame. Experiments were performed in a high Q microwave cavity with the cavity tuned so that the maximum microwave field is located in the vicinity of a flat flame front. Equivalence ratios were varied between 0.6 and 0.8. When the flame is radiated by a continuous wave microwave field of approximately 5 kV/cm, the flame front is observed to move towards the burner exit and stabilize at a standoff distance corresponding to a flame speed increase of up to 20%. No microwave discharge is observed, indicating that the enhanced flame speed arises from microwave energy deposited directly into the reaction zone through coupling to the weakly ionized gas in that region. Laser diagnostics were performed to quantify temperature increase, the laminar flame speed enhancement, and changes in the OH radical concentration through filtered Rayleigh scattering, particle image velocimetry, and planar laser induced fluorescence, respectively. These measurements indicate that microwave radiation may prove to be an effective means to non-invasively control and enhance flame stability in combustors. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microwave-assisted pyrolysis of Mississippi coal: A comparative study with conventional pyrolysis

Pyrolysis conditions greatly affect the structure-reactivity relationship of char during coal gasification. Here, this work investigated the effect of temperature and microwave heating on the structural properties of the chars generated during pyrolysis, as well as gaseous and tar products. Results showed that microwave pyrolysis of Mississippi coal produced more gaseous products and less tars compared to conventional pyrolysis. Higher CO/CO 2 ratio (>1) was observed under microwave pyrolysis compared to conventional pyrolysis (CO/CO2 < 1), which may be explained by a greater extent of gasification between solid carbon and the CO 2 formed during microwave pyrolysis. Additionally, in microwave pyrolysis, the oil tars generated exhibited lower concentrations of polar oxygenates, while the wax tars showed higher concentrations of non-polar alkanes, as observed from the intensity of CH vibrations in FTIR. The product compositions and FTIR analysis of the tars (oils and waxes) suggest that the microwave interacted preferentially with these polar species, which have relatively higher dielectric properties compared to alkanes. The structure–reactivity relationship of the chars produced was also investigated using a variety of characterization tools such as XRD, BET, SEM, EDS, and FTIR. Finally, the char reactivity towards combustion suggested that microwave-produced chars have a higher thermal stability, likely due to lower O/C ratios, and could be utilized in the metallurgical industry.

01 COAL, LIGNITE, AND PEAT↗

Activated carbon supported Ni, Fe, and bimetallic NiFe catalysts for CO x -free H 2 production by microwave methane pyrolysis

The goal of this study was to test the effect of metal-impregnated carbon-based catalysts on the conversion of methane to hydrogen gas and solid carbon using microwave reactor technology. Monometallic and bimetallic catalysts on activated carbon supports (Ni/AC, Fe/AC, Ni-Fe/AC) are compared during methane pyrolysis testing. Catalytic methane pyrolysis was carried out in a microwave reactor at reaction temperatures of 600 °C and 800 °C. For comparison, one of the catalysts (Ni-Fe/AC) was tested in a conventionally heated reactor at 800 °C. The prepared catalysts were characterized by X-ray diffraction (XRD), while post-reaction catalysts were characterized by XRD and SEM. During reaction testing, the monometallic Ni/AC catalyst exhibited the best catalytic activity (CH 4 conversion: 46.0 and H 2 yield: 46.9%) when reacted in the microwave reactor, however, it suffered from rapid deactivation from carbon deposition (carbon yield: 0.39 gC/g catalyst). The bimetallic Ni-Fe/AC catalyst was slightly less active (CH 4 conversion: 36.9 and H 2 yield: 40.5%) but it was more resistant to carbon formation (carbon yield: 0.27 gC/g catalyst) suggesting it may have greater long-term stability. The Ni-Fe/AC catalyst was also the most energy efficient as it required the least microwave power to maintain the 800 °C reaction temperature compared to the other catalysts tested. Methane conversion of the bimetallic Ni-Fe/AC at 800 °C under microwave irradiation was three times the conversion under conventional heating at the same reaction temperature. Finally, this work demonstrates the use of microwave-specific catalysts for catalytic methane pyrolysis in a microwave reactor, and can be used as a foundation for further methane pyrolysis process and catalyst optimization for CO x -free H 2 production.

08 HYDROGEN↗

Methane Catalytic Pyrolysis by Microwave and Thermal Heating over Carbon Nanotube-Supported Catalysts: Productivity, Kinetics, and Energy Efficiency

Methane catalytic pyrolysis, which is the reaction to produce hydrogen and carbon without emitting CO 2 , represents an approach for decarbonization using natural gas as an energy resource. In this work, the endothermic pyrolysis reaction was carried out under two heating scenarios: convective thermal heating and microwave-driven irradiative heating. The pyrolysis reaction was conducted at 550-600 °C over carbon nanotube-supported Ni-Pd and Ni-Cu catalysts. On both catalysts, an enhanced methane conversion rate was observed under microwave irradiation. The enhanced catalytic activity was hypothetically caused by the presence of free electrons in the carbon atoms within CNT that enabled the CNT support to absorb microwave energy effectively and to be heated efficiently by microwave. The microwave catalytic pyrolysis has shown improvement in kinetics, where the apparent activation energy dropped from 45.5 kJ/mol under conventional convective heating to 24.8 kJ/mol under microwave irradiation. When the methane conversion rate is increased by 37 %, the microwave power consumption only changed by 10.8 %. The research demonstrated the potential of transforming natural gas to clean hydrogen and value-added carbon in a more energy-efficient way. Process simulation and techno-economic analysis showed that potentially hydrogen minimum selling price of about $1 /kg H 2 could be achieved.

03 NATURAL GAS↗

Electrically interfaced Brillouin-active waveguide for microwave photonic measurements

New strategies for converting signals between optical and microwave domains could play a pivotal role in advancing both classical and quantum technologies. Traditional approaches to optical-to-microwave transduction typically perturb or destroy the information encoded on intensity of the light field, eliminating the possibility for further processing or distribution of these signals. In this paper, we introduce an optical-to-microwave conversion method that allows for both detection and spectral analysis of microwave photonic signals without degradation of their information content. This functionality is demonstrated using an optomechanical waveguide integrated with a piezoelectric transducer. Efficient electromechanical and optomechanical coupling within this system permits bidirectional optical-to-microwave conversion with a quantum efficiency of up to -54.16 dB. Leveraging the preservation of the optical field envelope in intramodal Brillouin scattering, we demonstrate a multi-channel microwave photonic filter by transmitting an optical signal through a series of electro-optomechanical waveguide segments, each with distinct resonance frequencies. Such electro-optomechanical systems could offer flexible strategies for remote sensing, channelization, and spectrum analysis in microwave photonics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Propagating Structure Of A Microwave Driven Shock wave Inside A Tube

The thrust generation process of a microwave rocket is similar to a pulse detonation engine, and understanding the interactions between microwave plasma and shock waves is important. Shadowgraph images of the microwave plasma generated in a tube under atmospheric air were taken. The observed plasma and shock wave were propagating one-dimensionally at constant velocity inside the tube. In order to understand the flow field inside the rocket, one-dimensional CFD analysis was conducted. With the change of microwave power density, the structure of the flow field was classified into two regimes: Microwave Supported Combustion (MSC), and Microwave Supported Detonation (MSD). The structure of the MSD was different from the structure of a chemical detonation, which implied the existence of a preheating in front of the shock wave. Furthermore, the flight performance was estimated by calculating the momentum coupling coefficient. It was confirmed that the efficiency was nearly constant in the MSD regime, with the increase of microwave power density.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electric field measurement in microwave discharge ion thruster with electro-optic probe

In order to understand the internal phenomena in a microwave discharge ion thruster, it is important to measure the distribution of the microwave electric field inside the discharge chamber, which is directly related to the plasma production. In this study, we proposed a novel method of measuring a microwave electric field with an electro-optic (EO) probe based on the Pockels effect. The probe, including a cooling system, contains no metal and can be accessed in the discharge chamber with less disruption to the microwave distribution. This method enables measurement of the electric field profile under ion beam acceleration. We first verified the measurement with the EO probe by a comparison with a finite-difference time domain numerical simulation of the microwave electric field in atmosphere. Second, we showed that the deviations of the reflected microwave power and the beam current were less than 8% due to inserting the EO probe into the ion thruster under ion beam acceleration. Finally, we successfully demonstrated the measurement of the electric-field profile in the ion thruster under ion beam acceleration. These measurements show that the electric field distribution in the thruster dramatically changes in the ion thruster under ion beam acceleration as the propellant mass flow rate increases. These results indicate that this new method using an EO probe can provide a useful guide for improving the propulsion of microwave discharge ion thrusters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simple method for highlighting the temperature distribution into a liquid sample heated by microwave power field

Microwave induced heating is widely used in medical treatments, scientific and industrial applications. The temperature field inside a microwave heated sample is often inhomogenous, therefore multiple temperature sensors are required for an accurate result. Nowadays, non-contact (Infra Red thermography or microwave radiometry) or direct contact temperature measurement methods (expensive and sophisticated fiber optic temperature sensors transparent to microwave radiation) are mainly used. IR thermography gives only the surface temperature and can not be used for measuring temperature distributions in cross sections of a sample. In this paper we present a very simple experimental method for temperature distribution highlighting inside a cross section of a liquid sample, heated by a microwave radiation through a coaxial applicator. The method proposed is able to offer qualitative information about the heating distribution, using a temperature sensitive liquid crystal sheet. Inhomogeneities as smaller as 1°-2°C produced by the symmetry irregularities of the microwave applicator can be easily detected by visual inspection or by computer assisted color to temperature conversion. Therefore, the microwave applicator is tuned and verified with described method until the temperature inhomogeneities are solved.

36 MATERIALS SCIENCE↗

Temporally and spatially resolved characterization of microwave induced argon plasmas: Experiment and modeling

Experiments and modeling of the plasma-microwave interaction have been performed in a coaxial microwave plasma source at a field frequency of 2.45 GHz generating argon plasmas at pressures of 20 and 40 millibars and a ratio of flow rate to pressure of 0.125 sccm/Pa. The incident microwave power between 100 W and 300 W is supplied in a regime of a pulse-width modulation with cycle duration of 110 ms and a power-on time of 23 ms. The experiments are based on heterodyne reflectometry and microwave interferometry at 45.75 GHz. They provide the temporal behaviour of the complex reflection coefficient, the microwave power in the plasma, as well as the electron density in the afterglow zone of the discharge. The self-consistent spatially two-dimensional and time-dependent modeling complements the analysis of the plasma-microwave interaction delivering the plasma and electromagnetic field parameters. The consolidating experimental observations and model predictions allow further characterizing the plasma source. The generated plasma has a core occupying the region close to the end of the inner electrode, where maximum electron densities above 10{sup 20} m{sup −3} and electron temperatures of about 1 eV are observed. Due to a longer outer electrode of the coaxial structure, the plasma region is extended and fills the volume comprised by the outer electrode. The electron density reaches values of the order of 10{sup 19} m{sup −3}. The heating of the gas occurs in its great part due to elastic collisions with the plasma electrons. However, the contribution of the convective heating is important especially in the extended plasma region, where the gas temperature reaches its maximum values up to approximately 1400 K. The temporally and spatially resolved modeling enables a thorough investigation of the plasma-microwave interaction which clearly shows that the power in-coupling occurs in the region of the highest electron density during the early stage of the discharge. In the steady state phase, however, the power in-coupling occurs close to the source walls where the electron density is significantly lower than on the discharge axis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A time domain based method for the accurate measurement of Q-factor and resonance frequency of microwave resonators

We present a novel method to determine the resonant frequency and quality factor of microwave resonators which is faster, more stable, and conceptually simpler than the yet existing techniques. The microwave resonator is pumped with the microwave radiation at a frequency away from its resonance. It then emits an exponentially decaying radiation at its eigen-frequency when the excitation is rapidly switched off. The emitted microwave signal is down-converted with a microwave mixer, digitized, and its Fourier transformation (FT) directly yields the resonance curve in a single shot. Being a FT based method, this technique possesses the Fellgett (multiplex) and Connes (accuracy) advantages and it conceptually mimics that of pulsed nuclear magnetic resonance. We also establish a novel benchmark to compare accuracy of the different approaches of microwave resonator measurements. This shows that the present method has similar accuracy to the existing ones, which are based on sweeping or modulating the frequency of the microwave radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary experimental investigation of a complex dual-band high power microwave source

In order to promote the power conversion efficiency of a magnetically insulated transmission line oscillator (MILO) and obtain microwaves in dual bands, an axially extracted C-band virtual cathode oscillator (VCO) with multiple resonant cavities is introduced to partially utilize the load current of an S-band MILO. The formed novel dual-band high power microwave source called MILO and VCO is investigated with simulation and experimentally. A dual-band radiation antenna is designed to effectively radiate microwaves generated by the MILO and the VCO, respectively, while avoiding them being influenced by the microwave reflection and diffraction. The preliminary experimental results measured by the dual-band diagnostic system show that both the MILO and the VCO operate normally under repeated shots. A microwave of 2.1 GHz, 1.70 GW is generated from the MILO and a 0.37 GW microwave at frequencies of 4.1 GHz and 3.8 GHz is generated from the VCO under the condition of about 440 kV and 35 kA. Compared with a single MILO (10.6%), a MILO and VCO achieves higher total power and efficiency (13.4%) in both S and C bands, indicating that the load current of the MILO partially couples into the beam-wave interaction in the VCO and then contributes to the output microwaves. However, more works are needed regarding the spectrum purification of the VCO and promotion of the output power of both the MILO and the VCO.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microwave emission from lead zirconate titanate induced by impulsive mechanical load

This paper focuses on microwave emission from Lead zirconate titanate Pb [Zr{sub x}Ti{sub 1−x}] O{sub 3} (PZT) induced by mechanical stressing. The mechanical stress was initiated by impact of a sharp tungsten indenter on the upper surface of PZT ceramic. The sequences of microwave and current impulses, which flew from indenter to electric ground, were detected simultaneously. The voltage between the upper and lower surface of ceramic was measured to obtain the behavior of mechanical force acting on ceramic during the impact. It was found that the amplitude, form, and frequency of measured microwave impulses were different by compression and restitution phase of impact. Two different mechanisms of electron emission, responsible for microwave impulse generation, were proposed based on the dissimilar impulse behavior. The field emission from tungsten indenter is dominant during compression, whereas ferroemission dominates during restitution phase. Indeed, it was observed that the direction of the current flow, i.e., sign of current impulses is changed by transitions from compression to restitution phase of impact. The observed dissimilar behavior of microwave impulses, caused by increasing and decreasing applied force, can be used to calculate the contact time and behavior of mechanical force during mechanical impact on ceramic surface. It is shown that the generation of microwave impulses exhibits high reproducibility, impulse intensity, a low damping factor, and high mechanical failure resistance. Based on these microwave emission properties of PZT, the development of new type of stress sensor with spatial resolution of few microns becomes possible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Remote measurement of microwave distribution based on optical detection

In this letter, we present the development of a remote microwave measurement system. This method employs an arc discharge lamp that serves as an energy converter from microwave to visible light, which can propagate without transmission medium. Observed with a charge coupled device, quantitative microwave power distribution can be achieved when the operators and electronic instruments are in a distance from the high power region in order to reduce the potential risk. We perform the experiments using pulsed microwaves, and the results show that the system response is dependent on the microwave intensity over a certain range. Most importantly, the microwave distribution can be monitored in real time by optical observation of the response of a one-dimensional lamp array. The characteristics of low cost, a wide detection bandwidth, remote measurement, and room temperature operation make the system a preferred detector for microwave applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗