Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MCNPX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Proton irradiation damage of an annealed Alloy 718 beam window

Mechanical testing and microstructural analysis was performed on an Alloy 718 window that was in use at the Los Alamos Neutron Science Center (LANSCE) Isotope Production Facility (IPF) for approximately 5 years. It was replaced as part of the IPF preventive maintenance program. The window was transported to the Wing 9 hot cells at the Chemical and Metallurgical Research (CMR) LANL facility, visually inspected and 3-mm diameter samples were trepanned from the window for mechanical testing and microstructural analysis. Shear punch testing and optical metallography was performed at the CMR hot cells. The 1-mm diameter shear punch disks were cut into smaller samples to further reduce radiation exposure dose rate using Focus Ion Beam (FIB) and microstructure changes were analyzed using a Transmission Electron Microscopy (TEM). Irradiation doses were determined to be ~0.2–0.7 dpa (edge) to 11.3 dpa (peak of beam intensity) using autoradiography and MCNPX calculations. The corresponding irradiation temperatures were calculated to be ~34–120 °C with short excursion to be ~47–220 °C using ANSYS. Mechanical properties and microstructure analysis results with respect to calculated dpa and temperatures show that significant work hardening occurs but useful ductility still remains. The hardening in the lowest dose region (~0.2–0.7 dpa) was the highest and attributed to the formation of γ" precipitates and irradiation defect clusters/bubbles whereas the hardening in the highest dose region (~11.3 dpa) was lower and attributed mainly to irradiation defect clusters and some thermal annealing.

36 MATERIALS SCIENCE↗

Active-Interrogation Measurements of Fast Neutrons from Induced Fission in Low-Enriched Uranium

A detection system was designed with MCNPX-PoliMi to measure induced-fission neutrons from U-235 and U-238 using active interrogation. Measurements were then performed with this system at the Joint Research Centre (JRC) in Ispra, Italy on low-enriched uranium samples. Liquid scintillators measured induced fission neutron to characterize the samples in terms of their uranium mass and enrichment. Results are presented to investigate and support the use of organic liquid scintillators with active interrogation techniques to characterize uranium containing materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements and simulations of the cosmic-ray-induced neutron background

The cosmic-ray-induced neutron background at ground level has been measured and simulated in conjunction with EJ-309 organic liquid scintillators with an approximate deposited energy range of 0.5–6 MeV. Specifically, the pulse height distributions, net neutron count rates, and angular dependences were obtained. The simulations were carried out using the Monte Carlo transport code MCNPX-PoliMi combined with the (Cosmic-Ray Shower Generator) CRY source subroutine that returns secondary particles produced by cosmic rays. A scaling formula from literature was also implemented in the simulation. The angular dependence of the neutron count rate was measured by collimating the liquid scintillator with polyethylene to attain 18° angular resolution from 0° downwards to 72° horizontally. The neutron count rate was measured to be 23.10±1.69 h -1 sr -1 at 0°, and 7.20±0.78 h -1 sr -1 at 72°. The simulations and measurements compare well and show similar cosine anisotropy for the angular distribution. Finally, the study thus shows that the neutron background response in detector systems can be efficiently and accurately simulated using the procedures described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stochastic image reconstruction for a dual-particle imaging system

Stochastic image reconstruction has been applied to a dual-particle imaging system being designed for nuclear safeguards applications. The dual-particle imager (DPI) is a combined Compton-scatter and neutron-scatter camera capable of producing separate neutron and photon images. The stochastic origin ensembles (SOE) method was investigated as an imaging method for the DPI because only a minimal estimation of system response is required to produce images with quality that is comparable to common maximum-likelihood methods. Here, this work contains neutron and photon SOE image reconstructions for a 252Cf point source, two mixed-oxide (MOX) fuel canisters representing point sources, and the MOX fuel canisters representing a distributed source. Simulation of the DPI using MCNPX-PoliMi is validated by comparison of simulated and measured results. Because image quality is dependent on the number of counts and iterations used, the relationship between these quantities is investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Using anisotropies in prompt fission neutron coincidences to assess the neutron multiplication of highly multiplying subcritical plutonium assemblies

There is a significant and well-known anisotropy between the prompt neutrons emitted from a single fission event; these neutrons are most likely to be observed at angles near 0° or 180° relative to each other. However, the propagation of this anisotropy through different generations of a fission chain re-action has not been previously studied. We have measured this anisotropy in neutron–neutron coincidences from a subcritical highly-multiplying assembly of plutonium metal. The assembly was a 4.5 kg α-phase plutonium metal sphere composed of 94% 239 Pu and 6% 240 Pu by mass. Data were collected using two EJ-309 liquid scintillators and two EJ-299 plastic scintillators. The angular distribution of neutron–neutron coincidences was measured at 90° and 180° and found to be largely isotropic. Simulations were performed using MCNPX-PoliMi of similar plutonium metal spheres of varying sizes and a correlation between the neutron multiplication of the assembly and the anisotropy of neutron–neutron coincidences was observed. In principle, this correlation could be used to assess the neutron multi-plication of an unknown assembly.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiplication and Presence of Shielding Material from Time-Correlated Pulse-Height Measurements of Subcritical Plutonium Assemblies

Here, we present the results from the first measurements of the Time-Correlated Pulse-Height (TCPH) distributions from 4.5 kg sphere of α-phase weapons-grade plutonium metal in five configurations: bare, reflected by 1.27 cm and 2.54 cm of tungsten, and 2.54 cm and 7.62 cm of polyethylene. A new method for characterizing source multiplication and shielding configuration is also demonstrated. The method relies on solving for the underlying fission chain timing distribution that drives the spreading of the measured TCPH distribution. We found that a gamma distribution fits the fission chain timing distribution well and that the fit parameters correlate with both multiplication (rate parameter) and shielding material types (shape parameter). The source-to-detector distance was another free parameter that we were able to optimize, and proved to be the most well constrained parameter. MCNPX-PoliMi simulations were used to complement the measurements and help illustrate trends in these parameters and their relation to multiplication and the amount and type of material coupled to the subcritical assembly.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Review of Heavy Charged Particle Transport in MCNP6.2

The release of version 6.2 of the MCNP6 radiation transport code is imminent. To complement the newest release, a summary of the heavy charged particle physics models used in the 1 MeV to 1 GeV energy regime is presented. Several changes have been introduced into the charged particle physics models since the merger of the MCNP5 and MCNPX codes into MCNP6. Here, this article discusses the default models used in MCNP6 for continuous energy loss, energy straggling, and angular scattering of heavy charged particles. Explanations of the physics models’ theories are included as well.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A comparison of Monte Carlo fission models for safeguards neutron coincidence counters

Monte Carlo simulation is a powerful tool used to model neutron coincidence detectors for international safeguards. The simulation has typically sampled properties such as the fission neutron multiplicity, energy, and direction, from independent probability density functions. However, multiplicity counters detect event-based neutron correlations and thus more accurate fission event modeling is needed. To respond to this need, the Fission Reaction Event Yield Algorithm (FREYA) and the Cascading Gamma-ray Multiplicity with Fission (CGMF) models were added in the newest version of MCNP, MCNP6.2. The models simulate individual fission events conserving momentum, energy, and angular momentum such that correlated particles are emitted. The effects of the new models on simulations of safeguards neutron coincidence counters were studied and compared to standard MCNP simulations. The MCNPX-PoliMi model was also included in the comparison. The properties of fission neutrons from safeguards relevant isotopes were compared to literature references. Then a hypothetical simplified detector was modeled to isolate the effects of specific differences between models. Experimental measurements from previous work were modeled and agreements were compared. Lastly, the probabilities of correlated events occurring in the experimental measurements were calculated with the different models. For example, the probability was calculated of detecting neutrons from both induced fission in uranium and spontaneous fission of Cf-252 in the same fission chain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative Neutron Detection Efficiency in He-3 Proportional Counters and Liquid Scintillators

We present new results on the neutron detection efficiency of detection systems based on He-3 proportional counters compared to organic liquid scintillators. The experiments were conducted using a well-characterized Cf-252 neutron source, measured bare, and shielded with slabs of polyethylene. The results show that the intrinsic neutron detection efficiency for the bare source is approximately 25% for the He-3 system, and 67% for the liquid scintillator system. When polyethylene sheets were used to shield the source in 2.54 cm increments, the neutron detection efficiency of both systems decreased exponentially to approximately 10% for the case of 25.4 cm. Experimental results were simulated using MCNPX-PoliMi and good agreement was found between measurement and simulation results for all the cases considered here.

Organic scintillator, He-3, neutron detection, det↗

Exploiting fission chain reaction dynamics to image fissile materials

Radiation imaging is one potential method to verify nuclear weapons dismantlement. In this work, we present a method to discriminate between non-multiplying and multiplying neutron sources using a neutron coded aperture imaging system. This method applies time-correlated pulse-height (TCPH) analysis to identify neutrons in fission chain reactions and recreate images using only these events. This analysis was applied to measurements of weapons-grade plutonium (WGPu) metal and 252 Cf performed at the Nevada National Security Site (NNSS) Device Assembly Facility in July 2015. The results demonstrate it is possible to eliminate the non-fissile 252 Cf source from the image while preserving the fissile WGPu source. TCPH analysis was also applied to additional scenes in which the WGPu and 252 Cf sources were measured individually. The results of these separate measurements further demonstrate the ability to remove the non-fissile 252 Cf source and retain the fissile WGPu source. Simulations performed using MCNPX-PoliMi indicate that in a one hour measurement, hollow WGPu spheres are retained at a 1σ level for neutron multiplications M ≃ 2:7 and above. This work has potential application to dismantlement verification where it may be valuable to verify that all neutron sources in an image are multiplying.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calculations versus measurements for residual dose rates from SNS spent structures

Here, residual dose rate measurements were conducted on target vessel #13 and proton beam window #5 after extraction from their service locations. These measurements are used to verify calculation methods of radionuclide inventory assessment that are typically performed for nuclear waste characterization and transportation of these structures. Neutronics analyses for predicting residual dose rates are carried out using the transport code MCNPX and the transmutation code CINDER90. For transport analyses a complex and rigorous geometry model of the structures and their surroundings are applied. The neutronics analyses are carried out using the Bertini and CEM high energy physics models for simulating particles interactions above the table-based cross section range. Finally, obtained calculational results are analyzed and compared to the measured dose rates and overall show good agreement within 25%, which shows applicability of the methods used in analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An unstructured mesh based neutronics optimization workflow

We have developed a fully automated workflow to optimize the neutronics performance of the Second Target Station (STS) at the Oak Ridge National Laboratory’s Spallation Neutron Source. The optimization workflow starts with the parametrized solid CAD engineering models and converts them into the unstructured mesh (UM) models for the neutronics calculations with MCNP6.2. Calculations are executed and their results are loaded into the Dakota optimization toolkit. Dakota analyzes the results and proposes new geometry parameters for the next design iteration. The cycle repeats until the optimal parameters are found. The automated CAD to MCNP conversion, the use of high-fidelity UM models, and the use of modern optimizer are the key elements that advance the entire optimization workflow in comparison with the original workflow. The original workflow was based on a simplified constructive solid geometry (CSG) modeling with MCNPX, mcnp_pstudy tool, and an in-house optimizer. Herein to demonstrate the new workflow, we present a case of neutronics optimization of the moderator–reflector assembly (MRA). Apart from the MRA, the workflow can optimize other major STS components, such as the spallation target, neutron beamlines, radiation shielding, and various accelerator components. Importantly, the new workflow opens the door to the advanced multi-physics multi-parameter optimization and has the potential for use in other nuclear physics and accelerator applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shielded radiography with a laser-driven MeV-energy X-ray source

We report the results of experimental and numerical-simulation studies of shielded radiography using narrowband MeV-energy X-rays from a compact all-laser-driven inverse-Compton-scattering X-ray light source. This recently developed X-ray light source is based on a laser-wakefield accelerator with ultra-high-field gradient (GeV/cm). We demonstrate experimentally high-quality radiographic imaging (image contrast of 0.4 and signal-to-noise ratio of 2:1) of a target composed of 8-mm thick depleted uranium shielded by 80-mm thick steel, using a 6-MeV X-ray beam with a spread of 45% (FWHM) and 10 7 photons in a single shot. The corresponding dose of the X-ray pulse measured in front of the target is ~100 nGy/pulse. Simulations performed using the Monte-Carlo code MCNPX accurately reproduce the experimental results. These simulations also demonstrate that the narrow bandwidth of the Compton X-ray source operating at 6 and 9 MeV leads to a reduction of deposited dose as compared to broadband bremsstrahlung sources with the same end-point energy. The X-ray beam’s inherently low-divergence angle (~mrad) is advantageous and effective for interrogation at standoff distance. Furthermore, these results demonstrate significant benefits of all-laser driven Compton X-rays for shielded radiography.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Delta-ray Production in MCNP 6.2.0

Secondary electrons in the form of delta-rays, also referred to as knock-on electrons, have been a feature of MCNP for electron and positron transport for over 20 years. While MCNP6 now includes transport for a suite of heavy-ions and charged particles from its integration with MCNPX, the production of delta-rays was still limited to electron and positron transport. In the newest release of MCNP6, version 6.2.0, delta-ray production has now been extended for all energetic charged particles. The basis of this production is the analytical formulation from Rossi and ICRU Report 37. As a result, this paper discusses the MCNP6 heavy charged-particle implementation and provides production results for several benchmark/test problems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monte Carlo investigation of a high-efficiency, two-plane Compton camera for long-range localization of radioactive materials

Compton cameras have become an instrument of interest for long-range localization of radioactive materials in nuclear-nonproliferation applications. In this work, a specialized simulation tool was developed for the optimization of a Compton camera through realistic Monte Carlo simulations. This tool can be used for Compton cameras with different geometries. The MCNPX-PoliMi code was used to simulate Compton scatters and photoelectric absorptions in the camera's detectors. The imaging capability is derived from the physics of Compton scattering and the full-energy information obtained in photoelectric absorptions. The simulated system is a 1 1 m2 Compton camera consisting of two planar arrays of photon detectors. Several scintillators were evaluated: LaBr3, CaF2, and NaI(Tl) (all inorganic scintillators), and C9H10 (plastic organic scintillator). The investigation was carried out with a 137Cs source. A minimum detectable activity (MDA) was defined and used to assess the performance of cameras based on different detectors. The simulation results show that C9H10 is a reliable, low-cost, scatter-plane material, increasing the MDA by ~0.2 mCi when compared to a CaF2 scatter plane. On the other hand, the intrinsic background of LaBr3 undermines its above-average energy resolution as the MDA increased by ~0.5 mCi when compared to a NaI(Tl) absorption plane.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advances in the computation of the Sjöstrand, Rossi, and Feynman distributions

This study illustrates recent computational advances in the application of the Sjöstrand (area), Rossi, and Feynman methods to estimate the effective multiplication factor of a subcritical system driven by an external neutron source. The methodologies introduced in this study have been validated with the experimental results from the KUKA facility of Japan by Monte Carlo (MCNP6 and MCNPX) and deterministic (ERANOS, VARIANT, and PARTISN) codes. When the assembly is driven by a pulsed neutron source generated by a particle accelerator and delayed neutrons are at equilibrium, the Sjöstrand method becomes extremely fast if the integral of the reaction rate from a single pulse is split into two parts. These two integrals distinguish between the neutron counts during and after the pulse period. To conclude, when the facility is driven by a spontaneous fission neutron source, the timestamps of the detector neutron counts can be obtained up to the nanosecond precision using MCNP6, which allows obtaining the Rossi and Feynman distributions.

97 MATHEMATICS AND COMPUTING↗

A simulation pipeline for fast neutron imaging and spectroscopy using quantified detector attributes

Radiation imaging capabilities, essential in the nuclear nonproliferation regime, facilitate source localization and, in certain cases, spectroscopy. Scatter-based neutron cameras, which can measure the neutron signatures from special nuclear material, hold particular interest. Systems incorporating organic scintillators can extract neutron energy spectra, potentially distinguishing fission neutron sources from others, such as alpha-neutron sources. The development and testing of a scatter-based neutron imager, however, can be challenging without having an accurate simulation model or first constructing a prototype. This work describes a simulation pipeline that takes output from MCNPX-PoliMi simulations and creates the expected back-projection neutron images and neutron energy spectra. This pipeline was developed to improve the modeling of fast neutron imagers and bridge the current gap in literature, which predominantly focuses on gamma-ray Compton imager models. This work also reports on the significance of various real-world system considerations and their effects on the simulated detector responses. The pipeline was verified and validated with experimental data collected using a 252 Cf spontaneous fission source using a fast neutron scattering imager developed at the University of Michigan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing radiation tolerant polymer nanocomposites using C 60 as an additive

In nuclear facilities utilizing plutonium, polymeric materials are subjected to long-term, close-contact, and continuous α radiation exposure, which can lead to compounding material degradation and eventual failure. Herein we model the attenuation of α particles by linear-low-density polyethylene (LLDPE), polyvinyl alcohol (PVA) thin films, and C 60 using Monte Carlo N-Particle Extended (MCNPX) software. The degradation of these materials was investigated experimentally by irradiating them with a beam of α particles of 5.8 MeV energy at a tandem Van de Graaff accelerator delivering a dose rate of 2.95 × 10 6 rad s –1 over a 7.1 mm 2 sample area. Our development of a method to test α particle-induced material degradation using a tandem accelerator is significant as degradation from naturally occurring α sources (i.e. Pu, Am) occurs too slowly for these sources to be used in practical experiments. Our results show that PVA nanocomposites containing 5 wt% C 60 were found to withstand about 7 times the α dose of undoped PVA films before a puncture in the film was detected. When these films were adhered to a LLDPE sheet the dual layer polymer was capable of withstanding about 13 times the dose of LLDPE and nearly twice the dose of the doped PVA thin film alone. Doping polymers with C 60 is an attractive way to generate more durable, radiation tolerant materials without increasing the thickness of the material which would lead to greater waste for disposal. Furthermore, the results herein help to resolve a prevalent technical challenge faced in nuclear facilities that utilize polymeric materials for nuclear processing and disposal.

36 MATERIALS SCIENCE↗