Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MCNP6”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

LANL-SNL Collaboration on NCS Validation

During 2016, nuclear criticality safety (NCS) practitioners from SNL and code developers from LANL collaborated in several areas of interest to the DOE/NNSA Nuclear Criticality Safety Program (NCSP). This collaboration involved: - Testing of the preliminary release of the MCNP6- Whisper methodology, with feedback to the developers, - Sharing of the benchmark catalogs (the collection of MCNP input files and benchmark results), with 1101 cases from LANL and 866 cases from SNL, - Comparison and analysis of 357 benchmarks common to both catalogs, - Investigation of the impact of the different benchmark catalogs on sensitivity-uncertainty based NCS validation results from MCNP6-Whisper, - Investigation of the impact of randomized selections from the benchmark catalog on sensitivity-uncertainty based validation results from MCNP6-Whisper. - Investigation of the use of MCNP6-Whisper in selecting benchmarks for use in NCS validation for unique, nonstandard, legacy fuel applications. This paper summarizes the collaboration work and initial results. It must be noted that the results described herein are preliminary and need further research and detailed analysis. However, the initial results are very interesting, and it is important to share them with the NCSP community.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Minimum critical masses and their uncertainties for several fissile nuclides and reflectors - 14296

A systematic effort was undertaken to reevaluate the minimum critical mass for several fissile nuclides and reflectors. This was done using MCNP6 in combination with several modern nuclear data libraries, viz. ENDF/B-VII.1, JENDL-4.0 and JEFF-3.1.1. This combination was benchmarked extensively against criticality safety benchmarks. The procedure to extract the minimum critical mass from the MCNP6 calculations was carefully implemented, so that it would have a negligible impact on the accuracy of the end results. All parts of the calculation, i.e. nuclear data processing, MCNP6 models, and post-processing, were applied consistently for all cases, involving varying fissile nuclides and reflectors. Results for the minimum critical mass were generated for {sup 233,235}U, {sup 236,239,241}Pu, {sup 242m}Am, {sup 243,245,247}Cm, and {sup 249,251}Cf, for the case of water moderation and water reflection. For {sup 235}U, the minimum critical mass was also calculated for cases with other reflectors, such as beryllium, heavy water, graphite, lead, and concrete. The results for the water reflection cases are in good agreement with most of the literature values, but for the cases with reflectors such as graphite, lead, or concrete, there are sizable differences. The accuracy of the results was assessed in two ways. First, a comparison was made with criticality safety benchmark results, by selecting benchmarks that resemble the minimum mass systems the most. It was clear that for {sup 233,235}U and {sup 239}Pu with water reflection, the differences in minimum critical masses between the libraries are consistent with the differences obtained for benchmark cases. The difference between the benchmark calculations and the benchmark values is then an indication of the accuracy with which one can simulate comparable systems. Secondly, sensitivity runs were performed with the new MCNP6 sensitivity option, based on ENDF/B-VII.1 nuclear data. For each fissile nuclide, the sensitivity of k{sub eff} to cross sections such as capture, fission, elastic, inelastic was calculated for the minimum critical mass case. The same was done for the {sup 1}H and {sup 16}O cross sections in the moderator and reflector. The uncertainty in k{sub eff} was calculated by combining the sensitivity profiles with the appropriate ENDF/B-VII.1 covariance matrix, using the SUSD code. As a final step, the uncertainty in k{sub eff} can be translated to an uncertainty in the minimum critical mass. (author)

42 ENGINEERING↗

Review of Heavy Charged Particle Transport in MCNP6.2

The release of version 6.2 of the MCNP6 radiation transport code is imminent. To complement the newest release, a summary of the heavy charged particle physics models used in the 1 MeV to 1 GeV energy regime is presented. Several changes have been introduced into the charged particle physics models since the merger of the MCNP5 and MCNPX codes into MCNP6. Here, this article discusses the default models used in MCNP6 for continuous energy loss, energy straggling, and angular scattering of heavy charged particles. Explanations of the physics models’ theories are included as well.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of Delayed-Particle Emission Signatures for Pyroprocessing, Part 1: Fuel Assembly

An initial study was conducted with nondestructive assay analysis using the MCNP6 Monte Carlo radiation-transport code to calculate delayed-neutron and delayed- gamma emission signature monitors to characterize burnup and isotopic composition for pyroprocessing. The study consists of five parts. In Part 1, a generic Westinghouse fuel assembly model was modified to create models with 3% and 5% 235 U enrichments, 20, 30, 40, and 50 GWd/MTU burnups, and 3-, 5-, 10-, 20-, and 30-year cooling times. MCNP6 was used to create detail-rich delayed-particle source terms for fuel assembly. Delayed-gamma activity ratios were then developed for conventional 134 Cs/ 137 Cs, 134 Cs/ 154 Eu, and 154 Eu/ 137 Cs markers as a function of burnup and of actinide mass for elemental uranium, neptunium, plutonium, americium, and curium. In addition, data mining using photon tally data was employed to discover potential new delayed-gamma activity ratios. The data mining effort was streamlined by the creation and use of several utility codes to extract and process data. The study confirms behavior for burnup dependence of 134 Cs/ 137 Cs, 134 Cs/ 154 Eu, and 154 Eu/ 137 Cs markers. A process for the discovery of potential new delayed-gamma markers has been developed, and results are presented. The actinide and nonactinide inventories for the fuel assembly models are used as source materials for the electrorefining models. Parts 2–5 contain analysis of a pyrochemical separations model that includes an MCNP6 mockup of the INL Mark IV electrorefiner (see companion documents). Part 2 focuses on delayed-particle emissions from the electrorefiner with loaded fuel dissolution baskets before electrorefining. Part 3 investigates delayed-particle emissions from the electrorefiner following electrorefining. Part 4 presents delayed-particle emissions from other pyroprocessing units that contain material developed by the electrorefining process in Part 3. Part 5 parallels Part 4, except for a 10 wt% plutonium reduction.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Delta-ray Production in MCNP 6.2.0

Secondary electrons in the form of delta-rays, also referred to as knock-on electrons, have been a feature of MCNP for electron and positron transport for over 20 years. While MCNP6 now includes transport for a suite of heavy-ions and charged particles from its integration with MCNPX, the production of delta-rays was still limited to electron and positron transport. In the newest release of MCNP6, version 6.2.0, delta-ray production has now been extended for all energetic charged particles. The basis of this production is the analytical formulation from Rossi and ICRU Report 37. As a result, this paper discusses the MCNP6 heavy charged-particle implementation and provides production results for several benchmark/test problems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-J-149: Secondary Emission Detection for Improved Proton Relative Stopping Power Identification

Purpose: This research investigates application of secondary prompt gamma (PG) emission spectra, resulting from nuclear reactions induced by protons, to characterize tissue composition along the particle path. The objective of utilizing the intensity of discrete high-energy peaks of PG is to improve the accuracy of relative stopping power (RSP) values available for proton therapy treatment planning on a patient specific basis and to reduce uncertainty in dose depth calculations. Methods: In this research, MCNP6 was used to simulate PG emission spectra generated from proton induced nuclear reactions in medium of varying composition of carbon, oxygen, calcium and nitrogen, the predominant elements found in human tissue. The relative peak intensities at discrete energies predicted by MCNP6 were compared to the corresponding atomic composition of the medium. Results: The results have shown a good general agreement with experimentally measured values reported by other investigators. Unexpected divergence from experimental spectra was noted in the peak intensities for some cases depending on the source of the cross-section data when using compiled proton table libraries vs. physics models built into MCNP6. While the use of proton cross-section libraries is generally recommended when available, these libraries lack data for several less abundant isotopes. This limits the range of their applicability and forces the simulations to rely on physics models for reactions with natural atomic compositions. Conclusion: Current end-of-range proton imaging provides an average RSP for the total estimated track length. The accurate identification of tissue composition along the incident particle path using PG detection and characterization allows for improved determination of the tissue RSP on the local level. While this would allow for more accurate depth calculations resulting in tighter treatment margins, precise understanding of proton beam behavior in tissue of various compositions is necessary requiring detailed simulations with a high degree of accuracy.

60 APPLIED LIFE SCIENCES↗

WE-AB-204-12: Dosimetry at the Sub-Cellular Scale of Auger-Electron Emitter 99m-Tc in a Mouse Single Thyroid Follicle Model

Purpose: To perform a dosimetry study at the sub-cellular scale of Auger-electron emitter 99m-Tc using a mouse single thyroid cellular model to investigate the contribution of the 99m-Tc Auger-electrons to the absorbed dose and possible link to the thyroid stunning in in vivo experiments in mice, recently reported in literature. Methods: The simulation of S-values for Auger-electron emitting radionuclides was performed using both the recent MCNP6 software and the Geant4-DNA extension of the Geant4 toolkit. The dosimetric calculations were validated through comparison with results from literature, using a simple model of a single cell consisting of two concentric spheres of unit density water and for six Auger-electron emitting radionuclides. Furthermore, the S-values were calculated using a single thyroid follicle model for uniformly distributed 123-I and 125-I radionuclides and compared with published S-values. After validation, the simulation of the S-values was performed for the 99m-Tc radionuclide within the several mouse thyroid follicle cellular compartments, considering the radiative and non-radiative transitions of the 99m-Tc radiation spectrum. Results: The calculated S-values using MCNP6 are in good agreement with the results from literature, validating its use for the 99m-Tc S-values calculations. The most significant absorbed dose corresponds to the case where the radionuclide is uniformly distributed in the follicular cell’s nucleus, with a S-value of 7.8 mGy/disintegration, due mainly to the absorbed Auger-electrons. The results show that, at a sub-cellular scale, the emitted X-rays and gamma particles do not contribute significantly to the absorbed dose. Conclusion: In this work, MCNP6 was validated for dosimetric studies at the sub-cellular scale. It was shown that the contribution of the Auger-electrons to the absorbed dose is important at this scale compared to the emitted photons’ contribution and can’t be neglected. The obtained S-values of Auger-electron emitting 99m-Tc radionuclide will be presented and discussed.

60 APPLIED LIFE SCIENCES↗

REACTION SAMPLING IN MCATK: Using the Thermal Motion of the Target Nucleus to Perform Elastic and Inelastic Scattering (U)

We describe how the reaction sampling is currently performed in MCATK. The current reaction sampling method is modeled on the method coded in MCNP6 and briefly described in the MCNP manual. The method is validated using the MCATK criticality validation suite for comparison with MCNP6. The results of this validation suite show good agreement with results obtained with MCNP6.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulated Rossi-alpha analysis of an asymmetrically coupled bare metal HEU reactor system

The predictive capabilities of MCNP6 for neutron noise experiments are shown in a comparison to the results of a series of Rossi-alpha measurements performed by J. Mihalczo utilizing a coupled set of symmetrical bare HEU (high enrichment uranium) cylinders. The results from the ptrac simulations agree well with the historical measured values. A series of case studies were conducted to study the effects of geometrical asymmetry in the coupling between two bare metal HEU cylinders. The difficulty in observing such systems is due in part to the inability to determine the individual coupling coefficients from measurement: unlike the symmetrical cases, only the product of the values can be obtained. A method is proposed utilizing MCNP6 tally ratios to separate the coupling coefficients for such systems. This work provides insight into the behavior of asymmetrically-coupled systems as the separation distance between the two cores is changed and also as the asymmetry is increased. As the asymmetry increases, both the slower and the faster observable prompt neutron decay constants increase in magnitude. The coupling time constants are determined from the measured decay constants. As the separation distance increases, both coupling coefficients decrease as expected. Based on these findings, an effective computational method utilizing MCNP6 and the Rossi-alpha technique can be applied to the prediction of asymmetrical coupled system measurements. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Delayed-Gamma Energy Biasing with Exact Energy Sampling in MCNP 6.2.0

Characterization of delayed-particle signatures is of the utmost importance for detecting, identifying, and quantifying special nuclear material (SNM). Various non-destructive assay (NDA) techniques used in nuclear material safeguards rely on characteristic gamma-ray or neutron emissions to infer properties of a material. The all-particle, all-energy Monte-Carlo radiation transport code MCNP6 is capable of simulating delayed-particle signatures from SNM in addition to modeling the transport of emitted particles to a detector or other instrument. In some cases, NDA techniques require the measurement of low probability emissions from a given material. In physical scenarios, this problem can be bypassed by longer count-times or may be simply irrelevant due to the mass, and therefore the total activity, of the material being measured. However, when applying the Monte-Carlo method to such scenarios, sampling of low probability emissions requires a large number of histories to converge to a statistically acceptable solution. To address this issue, the delayed-neutron and gamma energy biasing feature was introduced in MCNP6 by H. Armstrong et al. in 2013 which allows the user to set up energy windows in which delayed-particle emission sampling can be adjusted. For delayed-gamma sampling, this biasing method was based on the bin-wise structure of gamma emission data for both the multi-bin gamma and line-emission sampling modes. Recent improvements have been made to the line-emission sampling algorithm which upgrade the previous mini-bin sampling treatment to an exact energy-line treatment. This upgrade was not compatible with the biasing method implemented by H. Armstrong et al. due to the sampled data no longer having a bin-wise structure in line-emission mode. For this reason the delayed-gamma energy biasing feature has been rewritten to support the exact line-sampling treatment. This paper provides a description of the delayed-gamma energy biasing (DGEB) feature in MCNP6 as well as results and discussion for a gamma-ray spectroscopy example used to demonstrate the biasing utility. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of Delayed-Particle Emission Signatures for Pyroprocessing. Part 1: ABTR Fuel Assembly

A three-part study is conducted using the MCNP6 Monte Carlo radiation-transport code to calculate delayed-neutron (DN) and delayed-gamma (DG) emission signatures for nondestructive assay (NDA) metal-fuel pyroprocessing. In Part 1, MCNP6 is used to produce irradiation-induced used nuclear fuel (UNF) isotopic inventories for an Argonne National Laboratory (ANL) Advanced Burner Test Reactor (ABTR) preconceptual design fuel assembly (FA) model. The initial fuel inventory consists of uranium mixed with light-water-reactor transuranic (TRU) waste and 10 wt% zirconium (U-LWR-SFTRU-10%Zr). To facilitate understanding, parametric evaluation is done using models for 3% and 5% initial 235 U a% enrichments, burnups of 5, 10, 15, 20, 30, …, 120 GWd/MTIHM, and 3-, 5-, 10-, 20-, and 30- year cooling times. Detailed delayed-particle radioisotope source terms for the irradiate FA are created using BAMF-DRT and SOURCES3A. Using simulation tallies, DG activity ratios (DGARs) are developed for 134 Cs/ 137 Cs 134 Cs/ 154 Eu, and 154 Eu/ 137 Cs markers as a function of (1) burnup and (2) actinide mass, including elemental uranium, neptunium, plutonium, americium, and curium. Spectral-integrated DN emission is also tallied. The study reveals a rich assortment of DGAR behavior as a function of DGAR type, enrichment, burnup, and cooling time. Similarly, DN emission plots show variation as a function of burnup and of actinide mass. Sensitivity of DGAR and DN signatures to initial 235 U enrichment, burnup, and cooling time is evident. Comparisons of the ABTR radiation signatures and radiation signatures previously reported for a generic Westinghouse oxide-fuel assembly indicate that there are pronounced differences in the ABTR and Westinghouse oxide-fuel DN and DG signatures. These differences are largely attributable to the initial TRU inventory in the ABTR fuel. The actinide and nonactinide inventories for the FA models serve as source materials for the pre- and postelectrorefining models to be reported in Parts 2 and 3.

07 ISOTOPE AND RADIATION SOURCES↗

Characterization of the neutron flux during production of 18 F at a medical cyclotron and evaluation of the incidental neutron spectrum for neutron damage studies

The fast neutron spectrum was measured an irradiation position adjacent to two 18 F (fluorine-18) production targets at a medical cyclotron. The neutron spectrum was modeled using MCNP6 and experimentally determined using activation foils. A three-group neutron spectrum was determined using an over-determined least squares fitting method. The MCNP6 model results and measurements of the activation foils were used as input to unfold the neutron spectrum using the PNNL-STAYSL code. The neutron spectrum adjacent to the 18 F production target was evaluated for use in incidental experiments to evaluate neutron induced radiolysis of polyurethane and radiation hardness testing of electronics. The fast neutron flux near the 18 F target between the energies of 0.4 – 16.5 MeV was 1.8 – 3.0x10 9 n cm -2 s -1 . The neutron dose rate in polyurethane at the irradiation position was 2.8 cGy s -1 – 5.8 cGys -1 . The 1 MeV equivalent neutron flux was 2.4x10 9 n cm -2 s -1 – 4.0x10 9 n cm -2 s -1 .

18F-fluorodeoxyglucose↗

Advances in the computation of the Sjöstrand, Rossi, and Feynman distributions

This study illustrates recent computational advances in the application of the Sjöstrand (area), Rossi, and Feynman methods to estimate the effective multiplication factor of a subcritical system driven by an external neutron source. The methodologies introduced in this study have been validated with the experimental results from the KUKA facility of Japan by Monte Carlo (MCNP6 and MCNPX) and deterministic (ERANOS, VARIANT, and PARTISN) codes. When the assembly is driven by a pulsed neutron source generated by a particle accelerator and delayed neutrons are at equilibrium, the Sjöstrand method becomes extremely fast if the integral of the reaction rate from a single pulse is split into two parts. These two integrals distinguish between the neutron counts during and after the pulse period. To conclude, when the facility is driven by a spontaneous fission neutron source, the timestamps of the detector neutron counts can be obtained up to the nanosecond precision using MCNP6, which allows obtaining the Rossi and Feynman distributions.

97 MATHEMATICS AND COMPUTING↗

The MCNP ® 6 code: A decade of progress

After several years of effort involved in merging the Los Alamos National Laboratory MCNP5 and MCNPX codes, in 2013 the first production release of version 6 of the Monte Carlo N-Particle ® , or MCNP ® , code MCNP6.1 was distributed publicly. Since then, three significant releases have been issued: MCNP6.1.1beta in 2014, MCNP6.2 in 2018, and MCNP6.3 in 2023. While each release always contains new features, code enhancements, and bug fixes, each version has had a different primary focus, ranging from improved calculational efficiency to new powerful utilities and tools, to software modernization of the code base. With all that has been learned over the first decade of the MCNP6 code, continuous progress is being made toward a modernized, general-purpose Monte Carlo radiation transport code that remains a trusted resource for the global community of practitioners. This paper describes these first 10+ years of the MCNP6 code and its continually improving data libraries, and gives some insight into how the next decade is expected to unfold.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Production of Th 229 for medical applications: Excitation functions of low-energy protons on Th 232 targets

As a part of a general program to evaluate production routes for 229 Th, we studied production of 229 Th via proton-induced reactions on 232 Th targets bombarded with low-energy protons, E p ≤ 40MeV. The reported excitation functions include those for proton-induced reactions on natural thorium yielding to 228,229,230&232 Pa isotopes; 232 Th( p,xn ) reactions, where x=1, 3, 4, and 5, at proton energy ranges of 12–40 MeV. Although the data for 232 Th(p,n) 228 Pa, 232 Th(p,3n) 230 Pa, and 232 Th(p,5n) 232 Pa reactions were deduced by direct analysis of the thorium foils after irradiation, the data for 232 Th(p,4n) 229 Pa were obtained by radiochemical techniques. The half-life of 229 Pa was evaluated and determined to be 1.55 ± 0.01 d. Further, the α-branching ratio, α/(α + EC) of 229 Pa was evaluated to be 0.53 ± 0.10% by allowing 229 Pa to decay for ~7d, then chemically extracting and quantifying the 225 Ac (t 1/2 = 10.0±0.1d) from 229 Pa samples. In addition, we report the effective production cross section of 229 Th in a thick 232 Th target in the proton energy range of 23–33 MeV. The peak of the excitation function for the 232 Th(p,4n) 229 Pa reaction occurs at 162 ± 14 mb and E p =29.7±0.5MeV. This is only slightly larger than the effective cross section for the 232 Th(p,x) 229 Th reaction (obtained from a thick target experiment). This data indicates that the 232 Th(p,4n) 229 Pa reaction is the major reaction pathway for the cumulative 232 Th(p,x) 229 Th reaction cross section in this energy range. The measured cross sections were compared with theoretical cross sections using the simulation codes Particle and Heavy Ion Transport code System (PHITS) and Monte Carlo Neutral Particle 6 (MCNP6). Furthermore, at proton energy ranges of 12–33 MeV, the cumulative excitation function predicted by PHITS for the reactions leading to 229 Th was in close agreement with the experimental function, whereas the function predicted by MCNP6 was a factor of two higher at the peak of the excitation function.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-BRA-12: End-User Oriented Tools and Procedures for Testing Brachytherapy TPSs Employing MBDCAs

Purpose: To develop user-oriented tools for commissioning and dosimetry testing of {sup 192}Ir brachytherapy treatment planning systems (TPSs) employing model based dose calculation algorithms (MBDCAs). Methods: A software tool (BrachyGuide) has been developed for the automatic generation of MCNP6 input files from any CT based plan exported in DICOM RT format from Elekta and Varian TPSs. BrachyGuide also facilitates the evaluation of imported Monte Carlo (MC) and TPS dose distributions in terms of % dose differences and gamma index (CT overlaid colormaps or relative frequency plots) as well as DVHs and related indices. For users not equipped to perform MC, a set of computational models was prepared in DICOM format, accompanied by treatment plans and corresponding MCNP6 generated reference data. BrachyGuide can then be used to compare institutional and reference data as per TG186. The model set includes a water sphere with the MBDCA WG {sup 192}Ir source placed centrically and in two eccentric positions, a water sphere with cubic bone and lung inhomogeneities and a five source dwells plan, and a patient equivalent model with an Accelerated Partial Breast Irradiation (APBI) plan. Results: The tools developed were used for the dosimetry testing of the Acuros and ACE MBDCAs implemented in BrachyVision v.13 and Oncentra Brachy v.4.5, respectively. Findings were consistent with previous results in the literature. Besides points close to the source dwells, Acuros was found to agree within type A uncertainties with the reference MC results. Differences greater than MC type A uncertainty were observed for ACE at distances >5cm from the source dwells and in bone. Conclusion: The tools developed are efficient for brachytherapy MBDCA planning commissioning and testing. Since they are appropriate for distribution over the web, they will be put at the AAPM WG MBDCA’s disposal. Research co-financed by the ESF and Greek funds. NSRF operational Program: Education and Lifelong Learning Investing in Knowledge Society-Aristeia. Varian Medical Systems and Nucletron, an Elekta company provided access to TPSs for research purposes. Miss Peppa was supported by IKY-fellowships of excellence for postgraduate studies in Greece,Siemens Program.

60 APPLIED LIFE SCIENCES↗

TU-AB-201-09: Calibration of An Element of a New Directional Pd-103 Planar Source Array

Purpose: The CivaSheet™ is a new directional Pd-103 planar source array, with a variable number of discrete source elements referred to as “dots”. Each dot consists of a polymer capsule containing {sup 103}Pd and a gold shield that attenuates radiation on one side of the device to define hot and cold dose regions. Fluorescence from the gold shield is observed in the dot spectrum. Since CivaSheet™ is a planar directional source, conventional methods used for calibration of azimuthally symmetric sources are not applicable. The purpose of this work is to establish an air-kerma-strength standard and a transfer to a well chamber for clinical calibration. Methods: Primary air-kerma strength measurement of the dots was performed using a variable-aperture free-air chamber (VAFAC). Charge measurements were recorded using a well chamber with a custom insert. Anisotropy measurements were performed using a Sodium-Iodide detector. Spectral measurements were performed using a low-energy germanium detector and compared to a source without gold. The dot geometry was modeled using the MCNP6 radiation transport code. Results: Air-kerma strength measurements of a batch of four dots performed with the VAFAC were within ±1.5% of the average measured value and the measurement precision was within ±0.5%. Anisotropy measurements indicated uniform emission within the measurement uncertainty for the solid angle defining the VAFAC aperture used. Charge measurements of each dot using the well chamber in four cardinal angle source orientations were within ±1.5% of the average measured values. The spectral study of a dot resulted in identification of fluorescence from the gold shield and primary spectral energies that were compared to MCNP6 simulations. Conclusion: Calibration procedures for the new directional Pd-103 source dot were established for future clinical use, based on the results of experimental and Monte Carlo investigations. This work was partially supported by NCI contract (HHSN261201200052C) through CivaTech Oncology Inc.

60 APPLIED LIFE SCIENCES↗

Multidimensional dosimetry of {sup 106}Ru eye plaques using EBT3 films and its impact on treatment planning

Purpose: The purpose of this study was to establish a method to perform multidimensional radiochromic film measurements of {sup 106}Ru plaques and to benchmark the resulting dose distributions against Monte Carlo simulations (MC), microdiamond, and diode measurements. Methods: Absolute dose rates and relative dose distributions in multiple planes were determined for three different plaque models (CCB, CCA, and COB), and three different plaques per model, using EBT3 films in an in-house developed polystyrene phantom and the MCNP6 MC code. Dose difference maps were generated to analyze interplaque variations for a specific type, and for comparing measurements against MC simulations. Furthermore, dose distributions were validated against values specified by the manufacturer (BEBIG) and microdiamond and diode measurements in a water scanning phantom. Radial profiles were assessed and used to estimate dosimetric margins for a given combination of representative tumor geometry and plaque size. Results: Absolute dose rates at a reference depth of 2 mm on the central axis of the plaque show an agreement better than 5% (10%) when comparing film measurements (MCNP6) to the manufacturer’s data. The reproducibility of depth-dose profile measurements was <7% (2 SD) for all investigated detectors and plaque types. Dose difference maps revealed minor interplaque deviations for a specific plaque type due to inhomogeneities of the active layer. The evaluation of dosimetric margins showed that for a majority of the investigated cases, the tumor was not completely covered by the 100% isodose prescribed to the tumor apex if the difference between geometrical plaque size and tumor base ≤4 mm. Conclusions: EBT3 film dosimetry in an in-house developed phantom was successfully used to characterize the dosimetric properties of different {sup 106}Ru plaque models. The film measurements were validated against MC calculations and other experimental methods and showed a good agreement with data from BEBIG well within published tolerances. The dosimetric information as well as interplaque comparison can be used for comprehensive quality assurance and for considerations in the treatment planning of ophthalmic brachytherapy.

60 APPLIED LIFE SCIENCES↗