Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASS SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

The Q continuum simulation: Harnessing the power of GPU accelerated supercomputers

Modeling large-scale sky survey observations is a key driver for the continuing development of high-resolution, large-volume, cosmological simulations. We report the first results from the “Q Continuum” cosmological N-body simulation run carried out on the GPU-accelerated supercomputer Titan. The simulation encompasses a volume of (1300 Mpc){sup 3} and evolves more than half a trillion particles, leading to a particle mass resolution of m{sub p}≃1.5⋅10{sup 8} M{sub ⊙}. At this mass resolution, the Q Continuum run is currently the largest cosmology simulation available. It enables the construction of detailed synthetic sky catalogs, encompassing different modeling methodologies, including semi-analytic modeling and sub-halo abundance matching in a large, cosmological volume. Here we describe the simulation and outputs in detail and present first results for a range of cosmological statistics, such as mass power spectra, halo mass functions, and halo mass-concentration relations for different epochs. We also provide details on challenges connected to running a simulation on almost 90% of Titan, one of the fastest supercomputers in the world, including our usage of Titan’s GPU accelerators.

79 ASTRONOMY AND ASTROPHYSICS↗

Best practices and benchmarks for intact protein analysis for top-down mass spectrometry

One gene can give rise to many functionally distinct proteoforms, each of which has a characteristic molecular mass. Many laboratories, however, forgo the challenging mass analysis of intact proteins. Instead, these researchers resort to well-established methods for proteolytic digests. In this work, the Consortium for Top-Down Proteomics (CTDP) addresses the unmet need for robust protocols for obtaining intact protein mass spectra. We quantify and rationalize the signal suppression associated with common interfering substances. A decision tree, based upon sample composition and experimental goals, guides researchers to a given protocol. Cross-platform analytical benchmarks are provided to allow users to gauge their proficiency and to promote method standardization. This work should permit users at any experience level to obtain high-quality intact mass spectra of native and denatured proteins from mixtures of varying complexity, including intact antibodies and membrane proteins.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental studies of high-temperature thermal dissociation of iso-propanol

iso-Propanol is an important biofuel for transportation and industrial applications, as well as a canonical compound for understanding alcohol reaction chemistry. There are few studies of the thermal decomposition of iso-propanol, hence the objective of this work was to investigate the mechanism of iso-propanol pyrolysis at high-temperature conditions. Shock tube studies were used to investigate the thermal decomposition of iso-propanol and identify the dominant reaction pathways and the intermediate species present in the temperature range of 1395–2053 K and at pressures of 0.3–4 bar. Time-resolved mass spectra were obtained from pyrolysis experiments in shock tube/mass spectrometer apparatuses using electron impact ionization or synchrotron vacuum ultraviolet photoionization. The relative concentrations of the intermediate species were used to identify the dominant reaction channels. iso-Propanol dissociated by water loss to propene and by elimination of a methyl radical yielding a 1-hydroxyethyl radical at the conditions studied. The time-dependent mass spectra allowed secondary products to be identified along with the orders of appearance. Notably, peaks at m/z = 50 and 52 were observed providing insight into secondary reactions. These features have not been previously reported in propanol-pyrolysis literature.

Kim, John H. [Univ. of Michigan, Ann Arbor, MI (Un↗

A new detector for mass spectrometry: Direct detection of low energy ions using a multi-pixel photon counter

A new type of ion detector for mass spectrometry and general detection of low energy ions is presented. The detector consists of a scintillator optically coupled to a single-photon avalanche photodiode (SPAD) array. A prototype sensor has been constructed from a LYSO (Lu{sub 1.8}Y{sub 0.2}SiO{sub 5}(Ce)) scintillator crystal coupled to a commercial SPAD array detector. As proof of concept, the detector is used to record the time-of-flight mass spectra of butanone and carbon disulphide, and the dependence of detection sensitivity on the ion kinetic energy is characterised.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Derivatization of Dextran for Multiply Charged Ion Formation and Electrospray Ionization Time-of-Flight Mass Spectrometric Analysis

We present the use of a simple, one-pot derivatization to allow the polysaccharide dextran to carry multiple positive charges, shifting its molecular weight distribution to a lower m/z range. We performed this derivatization because molecular weight measurements of polysaccharides by mass spectrometry are challenging because of their lack of readily ionizable groups. The absence of ionizable groups limits proton abstraction and suppresses proton adduction during the ionization process, producing mass spectra with predominantly singly charged metal adduct ions, thereby limiting the detection of large polysaccharides. To address this challenge, we derivatized dextran T1 (approximately 1 kDa) by attaching ethylenediamine, giving dextran readily ionizable, terminal amine functional groups. The attached ethylenediamine groups facilitated proton adduction during the ionization process in positive ion mode. Using the low molecular weight dextran T1, we tracked the number of ethylenediamine attachments by measuring the mass shift from underivatized to derivatized dextran T1. Using electrospray ionization time-of-flight mass spectrometry, we observed derivatized dextran chains ranging from two to nine glucose residues with between one and four attachments/charges. Our success in shifting derivatized dextran T1 toward the low m/z range suggests potential for this derivatization as a viable route for analysis of high molecular weight polysaccharides using electrospray ionization time-of-flight mass spectrometry. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Molecular beam scattering from C-13 enriched Kapton and correlation with the EOIM-3 carousel experiment

Mass spectra of products emerging from identical samples of a C-13-enriched polyimide polymer (chemically equivalent to Kapton) under atomic oxygen bombardment in space and in the laboratory were collected. Reaction products unambiguously detected in space were CO-13, NO, (12)CO2, and (13)CO2. These reaction products and two others, H2O and CO-12, were detected in the laboratory, along with inelastically scattered atomic and molecular oxygen. Qualitative agreement was seen in the mass spectra taken in space and in the laboratory; the agreement may be improved by reducing the fraction of O2 in the laboratory molecular beam. Both laboratory and space data indicated that CO and CO2 products come preferentially from reaction with the imide component of the polymer chain, raising the possibility that the either component may degrade in part by the 'evaporation' of higher molecular weight fragments. Laboratory time-of-flight distributions showed: (1) incomplete energy accommodation of impinging O and O2 species that do not react with the surface; and (2) both hyperthermal and thermal CO and CO2 products, suggesting two distinct reaction mechanisms with the surface.

Minton, Timothy K.↗

Low-Temperature Formation of Carbonaceous Grains from PAHs

Astronomical observations have detected interstellar carbon in the form of polycyclic aromatic hydrocarbons(PAHs) as well as carbonaceous dust, confirming its presence in both gaseous and solid phases. The goal of this study is to experimentally investigate low-temperature chemical pathways between these two phases in order to better understand the evolution of cosmic carbon. Cosmic dust analogs are produced in the supersonic expansion of an argon jet seeded with aromatic molecules: benzene, naphthalene, anthracene, phenanthrene, and pyrene. These are prototype aromatic molecules of compact and non compact structure, and are used to evaluate the effect of precursor structure on the molecular complexity of the resulting grains. The seeded jet is exposed to an electrical discharge and the carbonaceous grains are collected and probed ex situ via laser desorption mass spectrometry. Mass spectra reveal a rich molecular diversity within the grains, including fragments of the parent molecule but also growth into larger complex organic molecules (COMs). In all experiments, the largest number of products is found in the m/z range 200-250, and C16H10 (attributed to pyrene and/or its isomers) is found to be a dominant product, pointing at the formation of this stable PAH as a preferential route in the growth to larger PAHs. Comparison to mass spectra from the Murchison meteorite reveals a similar dominance of compounds related toC16H10 at m/z = 202. Evidence of the methyl addition-cyclization mechanism in the anthracene experiment is reported. PAH structure is found to impact the dust production yield, as seen by the greater yield for the anthracene compared to the phenanthrene experiment. PAH growth at low temperatures via barrierless routes involving the addition of alkyl- and phenyl-type radicals is suggested as a viable pathway to COMs. These results suggest that PAH growth and dust formation from PAHs are feasible at low temperatures in photon-dominated regions and circumstellar envelopes.

L Gavilan↗

Fourier Transform Ion Cyclotron Resonance Mass Spectrometry at the Cyclotron Frequency

The phenomenon of ion cyclotron resonance allows for determining mass-to-charge ratio, m/z, of an ensemble of ions by means of measurements of their cyclotron frequency, ω{sub c}. In Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), the ω{sub c} quantity is usually unavailable for direct measurements: the resonant state is located close to the reduced cyclotron frequency (ω{sub +}), whereas the ω{sub c} and the corresponding m/z values may be calculated via theoretical derivation from an experimental estimate of the ω{sub +} quantity. Here, we describe an experimental observation of a new resonant state, which is located close to the ω{sub c} frequency and is established because of azimuthally-dependent trapping electric fields of the recently developed ICR cells with narrow aperture detection electrodes. We show that in mass spectra, peaks close to ω{sub +} frequencies can be reduced to negligible levels relative to peaks close to ω{sub c} frequencies. Due to reduced errors with which the ω{sub c} quantity is obtained, the new resonance provides a means of cyclotron frequency measurements with precision greater than that achieved when ω{sub +} frequency peaks are employed. The described phenomenon may be considered for a development into an FT-ICR MS technology with increased mass accuracy for applications in basic research, life, and environmental sciences. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of submicron particles influenced by mixed biogenic and anthropogenic emissions using high-resolution aerosol mass spectrometry: results from CARES

The Carbonaceous Aerosols and Radiative Effects Study (CARES) took place in the Sacramento Valley of California in summer 2010. We present results obtained at Cool, CA, the T1 site of the project ({approx}40 km downwind of urban emissions from Sacramento), where we deployed an Aerodyne high resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) in parallel with complementary instrumentation to characterize the sources and processes of submicron particles (PM1). Cool is located at the foothill of the Sierra Nevada Mountains, where intense biogenic emissions are periodically mixed with urban outflow transported by daytime southwesterly winds from the Sacramento metropolitan area. The particle mass loading was low (3.0 {micro}gm{sup -3} on average) and dominated by organics (80% of the PM1 mass) followed by sulfate (9.9 %). Organics and sulfate appeared to be externally mixed, as suggested by their different time series (r2 = 0.13) and size distributions. Sulfate showed a bimodal distribution with a droplet mode peaking at {approx}400nm in vacuum aerodynamic diameter (Dva), and a condensation mode at {approx}150 nm, while organics generally displayed a broad distribution in 60-600nm (Dva). New particle formation and growth events were observed almost every day, emphasizing the roles of organics and sulfate in new particle growth, especially that of organics. The organic aerosol (OA) had a nominal formula of C{sub 1}H{sub 1.38}N{sub 0.004}O{sub 0.44}, thus an average organic mass-to-carbon (OM/OC) ratio of 1.70. Two different oxygenated OA (OOA, 90% of total OA mass) and a hydrocarbon-like OA (HOA, 10 %) were identified by Positive matrix factorization (PMF) of the high resolution mass spectra. The more oxidized MO-OOA (O/C = 0.54) corresponded to secondary OA (SOA) primarily influenced by biogenic emissions, while the less oxidized LO-OOA (O/C = 0.42) corresponded to SOA associated with urban transport. The HOA factor corresponded to primary emissions mainly due to local traffic. Twenty three periods of urban plumes from T0 (Sacramento) to T1 (Cool) were identified using the Weather Research and Forecasting model coupled with Chemistry (WRF-Chem). The average PM1 mass loading was much higher in urban plumes (3.9 {micro}gm{sup -3}) than in air masses dominated by biogenic SOA (1.8 {micro}gm{sup -3}). The change in OA mass relative to CO ({Delta}OA/{Delta}CO) varied in the range of 5-196 {micro}gm{sup -3} ppm{sup -1}, reflecting large variability in SOA production. The highest {Delta}OA/{Delta}CO were reached when urban plumes arrived at Cool in the presence of a high concentration of biogenic volatile organic compounds (BVOCs=isoprene+monoterpenes+2-methyl-3-buten-2- ol [MBO]+methyl chavicol). This ratio, which was 77 {micro}gm{sup -3} ppm{sup -1} on average when BVOCs > 2 ppb, is much higher than when urban plumes arrived in a low biogenic VOCs environment (28 {micro}gm{sup -3} ppm{sup -1} when BVOCs < 0.7 ppb) or during other periods dominated by biogenic SOA (40 {micro}gm{sup -3} ppm{sup -1}). The results from this study demon10 strate that SOA formation is enhanced when anthropogenic emissions interact with biogenic precursors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fast Eruption Desorption Ionization for Mass Spectrometric Analysis

Fast eruption desorption ionization (FEDI) technique was developed for simple, rapid, and sensitive analysis of various compounds. The FEDI allows three analytical modes each with the unique characteristic. The results demonstrated that non-assisted eruption was suitable for stable and volatile compounds, energetic material (EM)-assisted for nonvolatile molecules especially metal compounds, and solvent-assisted eruption for fragile molecules. High-quality mass spectra with intact ions of analytes were obtained in positive and negative ion modes. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The NASA/JPL Evaluation of Oxygen Interactions with Materials-3 (EOIM-3)

The deleterious effects of hyperthermal atomic oxygen (AO) found in low-earth-orbit (LEO) environments on critical flight materials has been known since early shuttle flights. This corrosive effect is of considerable concern because it compromises the performance and longevity of spacecraft/satellite materials deployed for extended periods in LEO. The NASA Evaluation of Oxygen Interactions with Materials-3 (EOIM-3) experiment served as a testbed for a variety of candidate flight materials for space assets. A total of 57 JPL test specimens were present in six subexperiments aboard EOIM-3. In addition to a number of passive exposure materials for flight and advanced technology programs, several subexperiments were included to provide data for understanding the details of atomic oxygen interactions with materials. Data and interpretations are presented for the heated tray, heated strips, solar ultraviolet exposure, and scatterometer subexperiments, along with a detailed description of the exposure conditions experienced by materials in the various experiments. Mass spectra of products emerging from identical samples of a (sup 13)C-enriched polyimide polymer (chemically equivalent to Kapton) under atomic oxygen bombardment in space and in the laboratory were collected. Reaction products unambiguously detected in space were (sup 13)CO, NO, (sup 12)CO2, and (sup 13)CO2. These reaction products and two others, H2O and (sup 12)CO, were detected in the laboratory, along with inelastically scattered atomic and molecular oxygen. Qualitative agreement was seen in the mass spectra taken in space and in the laboratory; the agreement may be improved by reducing the fraction of O2 in the laboratory molecular beam.

Brinza, David E.↗

Formaldehyde chemistry in cometary ices: on the prospective detection of NH{sub 2}CH{sub 2}OH, HOCH{sub 2}OH, and POM by the on-board ROSINA instrument of the Rosetta mission

The thermal reactivity of a water-dominated cometary ice analog containing H{sub 2}CO and NH{sub 3} is investigated by means of Fourier transform infrared spectroscopy, mass spectrometry, and B3LYP calculations. Three products are characterized by these techniques: aminomethanol (NH{sub 2}CH{sub 2}OH), methyleneglycol (HOCH{sub 2}OH), and polyoxymethylene (POM, HO-(CH{sub 2}-O) {sub n}-H). Their formation strongly depends on the initial NH{sub 3}/H{sub 2}CO ratio. In addition, the influence of the initial ice composition on the thermal stability of POM has also been investigated. It is shown that POM formed during warming of the ices consists of short-chain polymers (i.e., oligomers of formaldehyde HO-(CH{sub 2}-O) {sub n}-H, n < 5), which are volatile at temperatures higher than 200 K. This suggests that gas-phase detection by the ROSINA instrument on board the Rosetta mission would be the most appropriate method to detect POM. Moreover, the mass spectra presented in this work might help in the interpretation of data that will be recorded by this instrument. Finally, a new scenario to explain the distributed source of formaldehyde observed in comets is discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Desorption Dynamics, Internal Energies and Imaging of Organic Molecules from Surfaces with Laser Desorption and Vacuum Ultraviolet (VUV) Photoionization

There is enormous interest in visualizing the chemical composition of organic material that comprises our world. A convenient method to obtain molecular information with high spatial resolution is imaging mass spectrometry. However, the internal energy deposited within molecules upon transfer to the gas phase from a surface can lead to increased fragmentation and to complications in analysis of mass spectra. Here it is shown that in laser desorption with postionization by tunable vacuum ultraviolet (VUV) radiation, the internal energy gained during laser desorption leads to minimal fragmentation of DNA bases. The internal temperature of laser-desorbed triacontane molecules approaches 670 K, whereas the internal temperature of thymine is 800 K. A synchrotron-based VUV postionization technique for determining translational temperatures reveals that biomolecules have translational temperatures in the range of 216-346 K. The observed low translational temperatures, as well as their decrease with increased desorption laser power is explained by collisional cooling. An example of imaging mass spectrometry on an organic polymer, using laser desorption VUV postionization shows 5 mu m feature details while using a 30 mu m laser spot size and 7 ns duration. Applications of laser desorption postionization to the analysis of cellulose, lignin and humic acids are briefly discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Decomposition of cyclohexane ion induced by intense femtosecond laser fields by ion-trap time-of-flight mass spectrometry

Decomposition of cyclohexane cations induced by intense femtosecond laser fields at the wavelength of 800 nm is investigated by ion-trap time-of-flight mass spectrometry in which cyclohexane cations C{sub 6}H{sub 12}{sup +} stored in an ion trap are irradiated with intense femtosecond laser pulses and the generated fragment ions are recorded by time-of-flight mass spectrometry. The various fragment ion species, C{sub 5}H{sub n}{sup +} (n = 7, 9), C{sub 4}H{sub n}{sup +} (n = 5–8), C{sub 3}H{sub n}{sup +} (n = 3–7), C{sub 2}H{sub n}{sup +} (n = 2–6), and CH{sub 3}{sup +}, identified in the mass spectra show that decomposition of C{sub 6}H{sub 12}{sup +} proceeds efficiently by the photo-irradiation. From the laser intensity dependences of the yields of the fragment ion species, the numbers of photons required for producing the respective fragment ions are estimated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Congruence of Clusters Defined By Whole Genome Sequencing and MALDI-TOF for Bacteria Isolated From Cleanrooms

Introduction: Oligotrophic conditions can render cleanrooms inhospitable to microbes. Despite these constraints, fungi and bacteria are frequently isolated from surfaces in astromaterials cleanrooms at the Johnson Space Center. Bacillus species are of particular concern because endospores belonging to this genus are resilient and can affect astromaterials. Current monitoring programs rely on 16S rRNA sequencing and the VITEK2 Compact system. These methods have limited power to resolve Bacillus species. Matrix-assisted laser desorption - time of flight mass spectrometry (MALDI-TOF MS), provides a rapid, low cost, method of identifying bacterial isolates and has a higher resolution than 16S rRNA sequencing, particularly for Bacillus species; however, few studies have compared this method to the industry gold standard, whole genome sequencing (WGS). Methods: Based on 16S rRNA classification, we selected 14 isolates for analysis with MALDI-TOF and WGS. Mass spectra were generated with MALDI-TOF MS and processed with custom scripts to identify clusters of closely related isolates and calculate a matrix of pairwise cosine similarity scores. Hybrid Illumina and Nanopore sequencing were used to generate draft genomes. Pairwise similarity scores were calculated from these genomes based on the average amino acid identity (AAI) predicted from single copy core genes. Congruence of clustering between these methods, was assessed by calculating adjusted Rand and Wallace coefficients. Results: Clusters of species generated from MALDI-TOF MS showed good agreement of phylotypes generated with WGS. Pairs of strains that were > 94% similar to each other in terms of predicted amino acid sequences consistently showed cosine similarities of mass spectra > 0.65 and, of the 9 clusters identified with WGS, 8 were identical with MALDI-TOF. This corresponds to an adjusted Rand index of 0.95 and a 95% confidence interval of 0.80 – 1.00 for adjusted Wallace coefficients. The only discordance was for a pair of isolates that were classified as Paenibacillus species. This pair showed relatively high similarity (0.84) in terms of MALDI-TOF MS but only 85% similarity in terms of AAI. Conclusion: This study shows that MALDI-TOF and WGS exhibit a similar ability to delineate Bacillus species isolated from cleanrooms and taxonomic units described by these two methods are consistent with one another. Since MALDI-TOF MS is low in cost and high in throughput, this approach appears to be an ideal option for routine microbial monitoring and identifying Bacillus species.

Farnaz Mazhari↗

Elemental and isotopic analysis of inorganic salts by laser desorption ionization mass spectrometry

Laser desorption ionization mass spectrometry is applied for the analysis of elements as well as their isotopic composition in different inorganic salts. At very low laser energies the inorganic ions are desorbed and ionized from the thin layer of the sample surface. The naturally occurring isotopes of alkali and silver ions are resolved using time of flight mass spectrometer. Further increase in laser energy shows the appearance of Al, Cr, and Fe ions in the mass spectra. This indicates the penetration laser beam beyond the sample surface leading to the ablation of sample target at higher energies. The simultaneous appearance of atomic ions from the sample target at relatively higher laser energies hampers the unambiguous identification of amino acid residues from the biomolecular ions in MALDI-MS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GC/MS Method Development for Separating Lunar Volatile Ice Simulant Headspace Gases

Various investigators propose the lunar surface contains widely distributed volatiles, especially water- like species, i.e. OH and H2O. Surface volatiles are theorized to exist as a hydrated regolith layer, concentrated in extremely cold polar permanently shadowed regions (PSR), and/or solar wind implantation reservoirs in lunar glasses. The proposed sources of lunar surface volatiles range from cometary impacts, solar wind, or a supply present during moon formation. Future Artemis missions aim to collect and return the samples containing volatiles collected near lunar polar craters or PSRs. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving returned sample integrity as much as possible. Pristine volatile-bearing samples are invaluable to the scientific community seeking to unravel the history of the solar system. Realistically, a sample will experience alteration during collection, transportation back to earth, and storage. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on high-fidelity volatile-containing regolith simulants, the foundation for the future of cold curation. This abstract outlines the separation, identification, and quantification of headspace gases over volatile ice feed stock material using gas chromatography/mass spectrometry (GC/MS). Preliminary objectives concentrated on sample handling, reproducibility, and understanding the elution characteristics for each analyte. Initial GC/MS method development experiments utilized diluted static headspace sample preparation. Diluted samples were used because sampling headspace gases directly from a vial containing liquid analyte resulted in overloading of the column and detector. Overloading is evident based on chromatogram peak shapes and instrument contamination, or carry over, between experiments. A mixture of three alcohols were used for a majority of the sample handling and reproducibility studies. Reproducibility was tested via multiple users, calibration curves, and check standards. Stock solutions of condensed lunar volatile analytes included methanol, ammonia in methanol, hydrogen sulfide in water, and an equal volume mixture of methanol, ethanol, and isopropanol. Current samples use room air as the headspace sample matrix, however future experiments will incorporate an inert purge gas, such as argon or nitrogen. Three mL of each analyte solution were capped in separate 20 mL crimp top GC vials. Dilutions were carried out by removing an aliquot of headspace gases with a calibrated 1 mL gastight syringe and immediately transferring to a 20 mL capped crimp top vial. The GC/MS is a Thermo Fisher Trace 1310/ISQ 7000 with a TriPlus RSH autosampler and split/splitless injector module. The experiments outlined in this abstract use the following hardware: a 2.5 mL gastight headspace syringe tool, 1 mm ID x 78.5 mm length ultra-inert straight injection liner, and a TG-BondQ 30 m × 0.32 mm × 10 μm column. Various parameters, such as hardware selection and the temperature, pressure, and split ratio set points, continue to evolve as the overall experiment is refined. Diluted headspace chromatograms were collected for the individual stock solutions. Retention times, peak shapes, and mass spectra were evaluated and added to the data processing method for each molecule of interest. Figure 1 shows the total ion chromatograms for the three major lunar volatile simulant stock solutions: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. Tailing peak shapes for ammonia (2.98 min rt) and water (4.06 min rt) indicate the molecules are not properly eluting from the selected column with the current separation method. Additionally, hydrogen sulfide and ammonia have overlapping peak windows, which could impact quantification. Ongoing experiments aim to address the peak shape and overlapping via the separation method and hardware selection. Sample preparation reproducibility experiments used stock solution containing equal volumes of a non- interactive mixture of methanol, ethanol, and isopropanol. Mass spectrum ion traces were used to identify and quantify all three alcohols. Peaks were automatically detected, identified, and integrated through the mass spectra detection and processing parameters. Calibration response curves and check standards were used to evaluate the validity of the sample preparation procedure. Figure 2 shows the methanol chromatogram peak area versus total headspace dilution volume transferred from the alcohol mixture vial. The calibration response curves and check standards validate sample preparation procedure. Continuing data analysis efforts are working towards correlating the peak area and instrument response factor to the headspace analyte concentration and condensed phase composition. Static headspace gas chromatography theory relies on Dalton’s law, Raoult’s law, Henry’s Law, and the Kolb and Ettre equation to associate peak area to the analyte composition in a non-ideal solution. Equation 1 is a simplified expression derived from the aforementioned theories. Future experiments involve liquid injections of the individual stock solutions, liquid and headspace analysis of various stock solution combinations, and the addition of regolith simulants to the mixtures. Temperature is another variable expected to affect reaction rates and will be explored.

Cecilia L. Amick↗

Photo-stability of super-hydrogenated PAHs determined by action spectroscopy experiments

We have investigated the photo-stability of pristine and super-hydrogenated pyrene cations (C{sub 16}H{sub 10+m}{sup +},m=0,6, or 16) by means of gas-phase action spectroscopy. Optical absorption spectra and photo-induced dissociation mass spectra are presented. By measuring the yield of mass-selected photo-fragment ions as a function of laser pulse intensity, the number of photons (and hence the energy) needed for fragmentation of the carbon backbone was determined. Backbone fragmentation of pristine pyrene ions (C{sub 16}H{sub 10}{sup +}) requires absorption of three photons of energy just below 3 eV, whereas super-hydrogenated hexahydropyrene (C{sub 16}H{sub 16}{sup +}) must absorb two such photons and fully hydrogenated hexadecahydropyrene (C{sub 16}H{sub 26}{sup +}) only a single photon. These results are consistent with previously reported dissociation energies for these ions. Our experiments clearly demonstrate that the increased heat capacity from the additional hydrogen atoms does not compensate for the weakening of the carbon backbone when pyrene is hydrogenated. In photodissociation regions, super-hydrogenated Polycyclic Aromatic Hydrocarbons (PAHs) have been proposed to serve as catalysts for H{sub 2} formation. Our results indicate that carbon backbone fragmentation may be a serious competitor to H{sub 2} formation at least for small hydrogenated PAHs like pyrene.

79 ASTRONOMY AND ASTROPHYSICS↗