Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASS RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Auroral zone ion composition

Some recent observations of auroral ion composition that are relevant to magnetospheric and ionospheric models are discussed. The auroral zone and its role as the region of exchange of warm and hot plasmas between the magetosphere and ionosphere are described, and the ion masss, energy, and angle distributions observed on a typical midaltitude auroral zone crossing are presented and discussed. The central role of oxygen ions as a tracer of the processses involved in coupling of ionospheric and magnetospheric plasmas is addressed. Some recent observations using very high resolution ion mass spectrometer data that have improved understanding of magnetosphere-ionosphere interactions are reviewed.

Peterson, W. K.↗

Testing models of low-mass star formation - High-resolution far-infrared observations of L1551 IRS 5

A 50 and 100 micron wavelength study of L151 IRS 5 has yielded data consistent with the Adams et al. (1987) theoretical model prediction. It has proven possible to constrain a range of possible density gradients through source-emission modeling on the basis of the spherically-symmetric radiative transfer program of Egan et al. (1988) and a comparison of the observed scans at 50 and 100 microns. Attention is given to the effects of varying the dust grain properties of the spherical energy distribution of the source; the amount of mid-IR emission is highly sensitive to dust opacity and, because of poorly understood dust properties, is not a sensitive test for the presence of disks.

Butner, Harold M.↗

Bursts of transverse ion acceleration at rocket altitudes

High-time-resolution ion mass spectrometer distribution function measurements and wave data from a sounding rocket flight over an aurora have revealed the fine structure of the transverse ion acceleration mechanism in the upper ionosphere. The transversely accelerated ion (TAI) events can occur in a volume with a cross-field dimension as small as several tens of meters and thus appear as 50-100 ms ion bursts due to the rocket payload motion. Bulk heating to a characteristic energy of several eV and tail heating in the direction perpendicular to B of a few percent of ambient ions to a characteristic energy the order of 10 eV occur for both hydrogen and oxygen ions. The TAI at 90 deg pitch angle occur in localized regions of intense lower hybrid waves and in regions of density depletion. On close examination of the correlation between the wave bursts and the TAI it is believed that the waves produce the ion acceleration. The TAI occur during periods of field-aligned auroral electron bursts. Finally, near 1000 km altitude they occur about once every second. If the event presented here is considered average, the flux of TAI oxygen ions above 7 eV could account for the ion conic fluxes measured by the ISIS spacecraft.

Arnoldy, R. L.↗

Investigation of Pyridine Carboxylic Acids in CM2 Carbonaceous Chondrites: Potential Precursor Molecules for Ancient Coenzymes

The distribution and abundances of pyridine carboxylic acids (including nicotinic acid) in eight CM2 carbonaceous chondrites (ALH 85013, DOM 03183, DOM 08003, EET 96016, LAP 02333, LAP 02336, LEW 85311, and WIS 91600) were investigated by liquid chromatography coupled to UV detection and high resolution Orbitrap mass spectrometry. We find that pyridine monocarboxylic acids are prevalent in CM2-type chondrites and their abundance negatively correlates with the degree of pre-terrestrial aqueous alteration that the meteorite parent body experienced. We also report the first detection of pyridine dicarboxylic acids in carbonaceous chondrites. Additionally, we carried out laboratory studies of proton-irradiated pyridine in carbon dioxide-rich ices (a 1:1 mixture) to serve as a model of the interstellar ice chemistry that may have led to the synthesis of pyridine carboxylic acids. Analysis of the irradiated ice residue shows that a comparable suite of pyridine mono- and dicarboxylic acids was produced, although aqueous alteration may still play a role in the synthesis (and ultimate yield) of these compounds in carbonaceous meteorites. Nicotinic acid is a precursor to nicotinamide adenine dinucleotide, a likely ancient molecule used in cellular metabolism in all of life, and its common occurrence in CM2 chondrites may indicate that meteorites may have been a source of molecules for the emergence of more complex coenzymes on the early Earth.

precursor molecules↗

Investigation of Pyridine Carboxylic Acids in CM2 Carbonaceous Chondrites: Potential Precursor Molecules for Ancient Coenzymes

The distribution and abundances of pyridine carboxylic acids (including nicotinic acid) in eight CM2 carbonaceous chondrites (ALH 85013, DOM 03183, DOM 08003, EET 96016, LAP 02333, LAP 02336, LEW 85311, and WIS 91600) were investigated by liquid chromatography coupled to UV detection and high resolution Orbitrap mass spectrometry. We find that pyridine monocarboxylic acids are prevalent in CM2-type chondrites and their abundance negatively correlates with the degree of pre-terrestrial aqueous alteration that the meteorite parent body experienced. We lso report the first detection of pyridine dicarboxylic acids in carbonaceous chondrites. Additionally, we carried out laboratory studies of proton-irradiated pyridine in carbon dioxide-rich ices (a 1:1 mixture) to serve as a model of the interstellar ice chemistry that may have led to the synthesis of pyridine carboxylic acids. Analysis of the irradiated ice residue shows that a comparable suite of pyridine mono- and dicarboxylic acids was produced, although aqueous alteration may still play a role in the synthesis (and ultimate yield) of these compounds in carbonaceous meteorites. Nicotinic acid is a precursor to nicotinamide adenine dinucleotide, a likely ancient molecule used in cellular metabolism in all of life, and its common occurrence in CM2 chondrites may indicate that meteorites may have been a source of molecules for the emergence of more complex coenzymes on the early Earth.

Pyridine Carboxylic↗

Enceladus Life Finder: the Search for Life in a Habitable Moon

Enceladus is one of the most intriguing bodies in the solar system. In addition to having one of the brightest and youngest surfaces, this small Saturnian moon was recently discovered to have a plume erupting from its south polar terrain and a global subsurface ocean. The Cassini Mission discovered organics and nitrogen-bearing molecules in the plume, as well as salts and silicates that strongly suggest ocean water in contact with a rocky core. However, Cassini's instruments lack sufficient resolution and mass range to determine if these organics are of biotic origin. The Enceladus Life Finder (ELF) is a Discovery-class mission that would use two state-of-the-art mass spectrometers to target the gas and grains of the plume and search for evidence of life in this alien ocean.

Saturn↗

SIMS Studies of Allende Projectiles Fired into Stardust-type Aluminum Foils at 6 km/s

We have explored the feasibility of C-, N-, and O-isotopic measurements by NanoSIMS and of elemental abundance determinations by TOF-SIMS on residues of Allende projectiles that impacted Stardust-type aluminum foils in the laboratory at 6 km/s. These investigations are part of a consortium study aimed at providing the foundation for the characterization of matter associated with micro-craters that were produced during the encounter of the Stardust space probe with comet 81P/Wild 2. Eleven experimental impact craters were studied by NanoSIMS and eighteen by TOF-SIMS. Crater sizes were between 3 and 190 microns. The NanoSIMS measurements have shown that the crater morphology has only a minor effect on spatial resolution and on instrumental mass fractionation. The achievable spatial resolution is always better than 200 nm, and C- and O-isotopic ratios can be measured with a precision of several percent at a scale of several 100 nm, the typical size of presolar grains. This clearly demonstrates that presolar matter, provided it survives the impact into the aluminum foil partly intact, is recognizable even if embedded in material of Solar System origin. TOF-SIMS studies are restricted to materials from the crater rim. The element ratios of the major rockforming elements in the Allende projectiles are well characterized by the TOF-SIMS measurements, indicating that fractionation of those elements during impact can be expected to be negligible. This permits information on the type of impactor material to be obtained. For any more detailed assignments to specific chondrite groups, however, information on the abundances of the light elements, especially C, is crucial.

Hoppe, Peter↗

The ion mass spectrometer on Giotto

The design of the Giotto ion mass spectrometer (IMS) system, its calibration, and the initial flight performance are discussed. The IMS system consists of two sensors: one optimized for the outer coma, the other for the inner coma, with each sensor obtaining complementary information in the region for which it was not optimized. Both sensors feature mass-imaging characteristics, permitting simultaneous measurements of several ion species by means of multi-detector arrays, with resultant mass per charge resolution of not less than 20. In addition to mass per charge, the energy per charge and the elevation and azimuth of the incident ions were measured during the Giotto flight.

Balsiger, H.↗

Pyrolysis-high resolution gas chromatography and pyrolysis gas chromatography-mass spectrometry of kerogens and kerogen precursors

A series of kerogens and kerogen precursors isolated from DSDP samples, oil shales and recent algal mats have been examined by Curie point pyrolysis-high resolution gas chromatography and gas chromatography-mass spectrometry. This study has shown that the three main types of kerogens (marine, terrestrial and mixtures of both) can be characterized using these techniques. The marine (algal) kerogens yield principally aliphatic products and the terrestrial kerogens yield more aromatic and phenolic products with some n-alkanes and n-alkenes. The yields of n-alkanes and n-alkenes increase and phenols decrease with increasing geologic age, however, pyrolysis-GC cannot be used to characterize the influence of short term diagenesis on the kerogen structure.

Van De Meent, D.↗

Cometary particulate analyzer design definition study

A concept for remotely determining the relative abundance of elements contained in cometary particulates collected by a spacecraft was conducted with very encouraging results. The technique utilizes a short high intensity burst of laser radiation to vaporize and ionize collected particulate material. Ions extracted from this laser-produced plasma are analyzed in a time of flight mass spectrometer to yield an atomic mass spectrum representative of the relative abundance of elements in the particulates. A prototype analyzer system was designed, constructed, and tested. Results show that: (1) energy-time focus performs as predicted in improving resolution; (2) power densities sufficient to produce usable ionization efficiencies can be obtained; (3) complex alloys such as stainless steel can be analyzed; and (4) a tiny, simple and reliable laser used in the demonstration easily meets spacecraft power and mass limitations. A mass resolution of 150 was experimentally demonstrated at mass 108, and an analytical extrapolation predicts a resolution sufficient to separate masses 250 and 251.

Utterback, N. G.↗

Separation of isobaric Amino Acids and Small Molecule Metabolites Using Multipass Ion Mobility Analysis

Amino acids along with small molecule metabolites are important biomarkers for the study and detection of diseases that are initially analyzed in untargeted omics fashion. Amino acids and many metabolites are isomeric, and their specific form can have a significant impact on biological function. Chromatographic separation of isomers is challenging, and they cannot be resolved by mass spectrometry alone. Ion mobility is a technique that allows the separation of ions based on their size, shape, and charge. Here we present the results of the separation of isobaric amino acids and small molecule metabolites using a system that allows for multi-pass ion mobility separation which, in turn, enhances the ion mobility resolution of the separation. Amino acid standards and small molecule metabolites commercially available were infused directly into a SELECT SERIES™ Cyclic™ IMS system. Solutions of individual and mixture of the isobaric species were used and the mobility conditions were optimized for multiple passes for each corresponding set of isobaric species. Both ionization polarities and various solvent adducts were tested to provide the best signal intensity and separation. Amino acids such as leucine and isoleucine have previously been separated with ion mobility in a system with lower ion mobility resolution (SYNAPT™ G2 mass spectrometer) rendering about 90% of valley and mobility resolution of around 40 Ω/ΔΩ. With the enhanced ion mobility resolution using the cyclic IMS technique we have obtained almost complete separation of those amino acids rendering a valley of about 10% after 15 passes. For this case, the mobility resolution is around 250 Ω/ΔΩ. Another example is the separation of glucose-6-phosphate from glucose-1-phosphate, and fructose-6phosphate which were separated after 10 passes. For this case, the mobility resolution is around 205 Ω/ΔΩ.

Hernando J Olivos↗

Research in particles and fields

The astrophysical aspects of cosmic rays and gamma rays and the radiation and electromagnetic field environment of the Earth and other planets are investigated. These investigations are carried out by means of energetic particle and photon detector systems flown on spacecraft and balloons. Particle astrophysics is directed toward the investigation of galactic, solar, interplanetary, and planetary energetic particles and plasmas. The emphasis is on precision measurements with high resolution in charge, mass, and energy. Gamma ray research is directed toward the investigation of galactic, extragalactic, and solar gamma rays with spectrometers of high angular resolution and moderate energy resolution carried on spacecraft and balloons.

Stone, E. C.↗

Design of An Improved Miniature Ion Neutral Mass Spectrometer for NASA Applications

The ion optics of NASA's Ion Neutral Mass Spectrometer (INMS) sensor was simulated with three dimensional models of the open source, the quadrupole deflector, the exit lens system and the quadrupole mass analyzer to design more compact models with lower weight. Comparison of calculated transmission with experimental results shows good agreement. Transmission analyses with varying geometrical parameters and voltages throw light on possible ways of reducing the size of the sensor. Trajectories of ions of mass 1-99 amu were simulated to analyze and optimize transmission. Analysis of open source transmission with varying angle of attack shows that the angular acceptance can be considerably increased by programming the voltages on the ion trap/ collimator. Analysis of transmission sensitivity to voltages and misalignments of the quadrupole deflector rods indicate that increased transmission is possible with a geometrically asymmetrical deflector and a deflector can be designed with much lower sensitivities of transmission. Bringing the disks closer together can decrease the size of the quadrupole deflector and also increase transmission. The exit lens system can be redesigned to be smaller by eliminating at least one electrode entirely without loss of transmission. Ceramic materials were investigated to find suitable candidates for use in the construction of lighter weight mass spectrometer. A high-sensitivity, high-resolution portable gas chromatograph mass spectrometer with a mass range of 2-700 amu has been built and will be commercialized in Phase 3.

Swaminathan, Viji K.↗

Advanced Imaging for Space Science

Future NASA interferometric missions will realize high-resolution with less mass and volume compared to filled-apertures thus saving in cost over comparable filled-aperture systems. However, interferometeric aperture systems give reduced sensitivity requiring longer integration times to achieve a desired signal-to-noise ratio but is likely the only cost effective path forward for high-resolution space imaging.

Lyon, Richard G.↗