Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETOMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Impact of remanent magnetic field on the heat load of original CEBAF cryomodule

The heat load of the original cryomodules for the CEBAF accelerator is ~50% higher than the target value of 100 W at 2.07 K for refurbished cavities operating at an accelerating gradient of 12.5 MV/m. This issue is due to the quality factor of the cavities being ~50% lower in the cryomodule than when tested in a vertical cryostat, even at low RF field. Previous studies were not conclusive about the origin of the additional losses. We present the results of a systematic study of the additional losses in a five-cell cavity from a decommissioned cryomodule after attaching components, which are part of the cryomodule, such as the cold tuner, the He tank and the cold magnetic shield, prior to cryogenic testing in a vertical cryostat. Flux-gate magnetometers and temperature sensors are used as diagnostic elements. Different cool-down procedures and tests in different residual magnetic fields were investigated during the study. Here, three flux-gate magnetometers attached to one of the cavities installed in the refurbished cryomodule C50-12 confirmed the hypothesis of high residual magnetic field as a major cause for the increased RF losses.

43 PARTICLE ACCELERATORS↗

X-ray magnetic circular dichroism and small angle neutron scattering study of thiol capped gold nanoparticles.

X-ray magnetic circular dichroism (XMCD) and Small Angle Neutron Scattering (SANS) measurements were performed on thiol capped Au nanoparticles (NPs) embedded into polyethylene. An XMCD signal of 0.8 {center_dot} 10{sup -4} was found at the Au L{sub 3} edge of thiol capped Au NPs embedded in a polyethylene matrix for which Superconducting Quantum Interference Device (SQUID) magnetometry yielded a saturation magnetization, M{sub s}, of 0.06 emu/g{sub Au}. SANS measurements showed that the 3.2 nm average-diameter nanoparticles are 28% polydispersed, but no detectable SANS magnetic signal was found with the resolution and sensitivity accessible with the neutron experiment. A comparison with previous experiments carried out on Au NPs and multilayers, yield to different values between XMCD signals and magnetization measured by SQUID magnetometer. We discuss the origin of those differences.

42 ENGINEERING↗

A Multimodal Event Catalog and Waveform Data Set That Supports Explosion Monitoring from Nevada, U.S.A.

Multimodal, curated data sets and nuisance event catalogs remain rare in the explosion monitoring community relative to curated seismic data sets. The source of this relative absence is the difficultly in deploying multimodal receivers that sense the seismic, acoustic, and other modalities from multiphysics sources. We provide such a data set in this study that delivers seismic, infrasound, and electromagnetic (magnetometer) sensor records collected over a two–week period, within 255 km of a 10 ton buried chemical explosion called DAG–4 that was located at 37.1146°, –116.0693° on 22 June 2019 21:06:19.88 UTC. This catalog includes 485 seismic, seismoacoustic, and infrasound–only events that an expert analyst manually built by reviewing waveforms from 29 seismic and infrasound sensors. Our data release includes waveforms from these 29 seismic, infrasound, and seismoacoustic stations and two magnetometer stations and their station metadata. We deliver these waveforms in NNSA KB Core CSS.w format (i4) with a corresponding wfdisc table that provides the header information. Here, we expect that this data set will provide a valuable, benchmark resource to develop signal processing algorithms and explosion monitoring methods against manual, human observations.

58 GEOSCIENCES↗

Sensitivity of Surface Resistance to Trapped Flux in High-Purity Large-Grain Niobium

Surface resistance arising from trapped flux is experimentally measured, by which the sensitivity to trapped flux is derived. Measurements are carried out with single-cell L-band SRF cavities made of high-purity large-grain niobium materials, immersed in a uniform externally applied magnetic field generated by a solenoid with its axis overlapping the cavity axis. The surface resistance is found by using the standard technique for Q0 measurement and the customary G/Q0 analysis. Q0 values at a fixed low surface field are used. The trapped flux is found by measuring flux densities at a selected location using a single-axis fluxgate magnetometer attached to the cavity outer surface: Ba*[1-(Bsc-Bnc)/(Bsc0-Bnc)], where Ba is the applied external field, Bnc and Bsc is the local flux density measured just above and below Tc, respectively, during a field-cooling of the cavity and afterwards its Q0 is measured, Bsc0 is measured in a separate zero-field-cooling while the cavity being kept in the same location after turning on the identical applied field Ba at a temperature well below Tc . Several magnetometers are placed at various locations. It is found that the sensitivity to trapped flux in high-purity large-grain niobium to be 1.9 n?/µT on average. This is to be compared to 3-9 n?/µT in high purity fine-grain niobium and 10-50 n?/µT in nitrogen-doped high-purity niobium reported by other groups. We will discuss the measurement results as well as the measurement techniques.

Geng, Rongli↗

Rotating-Coil Measurement System for Small-Bore-Diameter Magnet Characterization

Rotating-coil measurement systems are widely used to measure the multipolar fields of particle accelerator magnets. This paper presents a rotating-coil measurement system that aims at providing a complete data set for the characterization of quadrupole magnets with small bore diameters (26 mm). The PCB magnetometer design represents a challenging goal for this type of transducer. It is characterized by an aspect ratio 30% higher than the state of the art, imposed by the reduced dimension of the external radius of the rotating shaft and the necessity of covering the entire magnet effective length (500 mm or higher). The system design required a novel design for the mechanical asset, also considering the innovation represented by the commercial carbon fiber tube, housing the PCB magnetometer. Moreover, the measurement system is based primarily on standard and commercially available components, with simplified control and post-processing software applications. The system and its components are cross-calibrated using a stretched-wire system and another rotating-coil system. The measurement precision is established in a measurement campaign performed on a quadrupole magnet characterized by an inner bore diameter of 45 mm.

42 ENGINEERING↗

Atomic magnetic gradiometer for room temperature high sensitivity magnetic field detection

A laser-based atomic magnetometer (LBAM) apparatus measures magnetic fields, comprising: a plurality of polarization detector cells to detect magnetic fields; a laser source optically coupled to the polarization detector cells; and a signal detector that measures the laser source after being coupled to the polarization detector cells, which may be alkali cells. A single polarization cell may be used for nuclear magnetic resonance (NMR) by prepolarizing the nuclear spins of an analyte, encoding spectroscopic and/or spatial information, and detecting NMR signals from the analyte with a laser-based atomic magnetometer to form NMR spectra and/or magnetic resonance images (MRI). There is no need of a magnetic field or cryogenics in the detection step, as it is detected through the LBAM.

47 OTHER INSTRUMENTATION↗

In-Situ Magnetic Field Reconstruction in the MAGIS-100 Experiment

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.; Ferm↗

In-situ synthesis of magnetic (NiFe{sub 2}O{sub 4}/CuO/FeO) nanocomposites

In-situ synthesis of magnetic nanocomposites with (NiFe{sub 2}O{sub 4}/CuO/FeO) crystal phases has been done using a sol-gel method by taking a non-stoichiometric composition of the precursors. The average particle size of the nanocomposites was calculated using X-ray diffraction (XRD) and high resolution tunneling electron microscope (HR-TEM) and it turns out to be {approx}20 nm. The vibrating sample magnetometer (VSM) measurements demonstrate the ferromagnetic nature of the nanocomposites. The synthesized nanocomposite was used to prepare magnetic fluid using tetramethylammonium hydroxide as a surfactant and its stability in the solution was also discussed. -- Graphical abstract: Magnetic nanocomposites containing (NiFe{sub 2}O{sub 4}/CuO/FeO) phases having particle size {approx}17 nm were synthesized by a sol-gel method. The synthesized nanocomposites exhibit ferromagnetic nature with small value of coercivity.

36 MATERIALS SCIENCE↗

Preparation, characterization, magnetic susceptibility (Eu, Gd and Sm) and XPS studies of Ln{sub 2}ZrTiO{sub 7} (Ln=La, Eu, Dy and Gd)

Bulk and nanosized pyrochlore materials Ln{sub 2}ZrTiO{sub 7} (Ln=La, Eu, Dy, Gd and Sm) have been prepared by the sol-gel method. All the samples were characterized by powder X-ray diffraction, Raman and X-ray photoelectron spectroscopy. Magnetic susceptibility ({chi}) measurements of Gd{sub 2}ZrTiO{sub 7}, Sm{sub 2}ZrTiO{sub 7} and Eu{sub 2}ZrTiO{sub 7} were carried out by vibrating sample magnetometer in the temperature range 2-320 K. The variation of {chi}{sup -1} (or {chi}) with temperature of Gd{sub 2}ZrTiO{sub 7}, Sm{sub 2}ZrTiO{sub 7} and Eu{sub 2}ZrTiO{sub 7} follows the Curie law, intermediate formula and the Curie-Weiss law, respectively. From the linear portion of {chi}T vs. T{sup -1} plot of Eu{sub 2}ZrTiO{sub 7} from 2 to 15 K, the classical nearest neighbor exchange (J{sup cl}) and dipolar interactions (D{sub nn}) are obtained. The XPS of Ln{sub 2}ZrTiO{sub 7} (Ln=La, Eu, Dy and Gd) gave characteristic peaks for Ln, Ti, Zr and O. The satellite peaks are observed only for 3d La of La{sub 2}ZrTiO{sub 7}. -- Graphical abstract: Sm{sub 2}ZrTiO{sub 7} does not follow the Curie or the Curie-Weiss law. The effective magnetic moment is found to be 0.768 BM (at 300 K), which is smaller than the free ion moment 1.3-1.4 BM. Display Omitted Research Highlights: {yields} Bulk and nano Ln{sub 2}ZrTiO{sub 7} (Ln=La, Eu, Dy, Gd and Sm) have been prepared by the sol-gel method. {yields} The broad Raman lines are attributed to cation disorder and small crystallite size. {yields} XPS of Ln{sub 2}ZrTiO{sub 7} exhibit characteristic X-ray photoelectron spectral features. {yields} Magnetic moment of Gd{sub 2}ZrTiO{sub 7} is obtained from magnetic susceptibility and ESR spectra.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Influence of annealing atmosphere on the magnetic properties of SiO{sub 2}/Fe/SiO{sub 2} sandwiched nanocomposite films

The magnetic properties of SiO{sub 2}/Fe/SiO{sub 2} nanocomposite films are studied by magnetic force microscopy and vibrating sample magnetometer. The films were fabricated by alternately depositing SiO{sub 2}, Fe, and SiO{sub 2} on Si substrates with magnetron sputtering followed by thermal annealing. It is found that the annealing atmosphere significantly influences the sample structure, composition, and magnetic properties. The samples annealed in forming gas show much better magnetic properties than those annealed in vacuum and in N{sub 2}. The saturation magnetization can reach 200 emu/g, fairly close to the value of bulk Fe, and the coercivity can reach 400 Oe, much higher than 10 Oe of the bulk Fe. X-ray photoelectron spectroscopic depth profile measurement was carried out to study the mechanism of the strong influence of annealing atmosphere. For the samples annealed in forming gas, Fe nanoparticles are mildly oxidized, forming thin shells of Fe{sub 2}O{sub 3} surrounding them, which is beneficial for maintaining the ferromagnetic behavior and enhancing the coercivity of nanoparticles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Chemical stability of highly (0001) textured Sm(CoCu){sub 5} thin films with a thin Ta capping layer

With the highest magnetocrystalline anisotropy constant (Ku) among practical magnetic materials, SmCo{sub 5} could be a very attractive candidate for future high areal density magnetic recording. However, its corrosion resistance is always a concern in recording media applications. In this paper, the chemical stability and microstructures of highly (0001) textured Sm(CoCu){sub 5} thin films with and without a 3 nm Ta capping layer were reported. For Sm(CoCu){sub 5} thin films without a capping layer, the coercivity decreases significantly (from 8kOe to 1kOe) within one month. Sm(CoCu){sub 5} thin films capped with a thin Ta layer (3 nm) behave differently. Even exposed to a laboratory environment (25 deg. C) over 3 years, the Ta-capped Sm(CoCu){sub 5} thin films are stable in terms of structural and magnetic properties, i.e., there were no changes in X-ray diffraction peaks and vibrating sample magnetometer hysteresis loops. Microstructure of Ta-capped Sm(CoCu){sub 5} thin films showed that Sm(CoCu){sub 5} formed a domelike particle assembly structure on a smooth Ru underlayer and were well covered by partially oxidized Ta capping layer, as shown by TEM cross-section micrographs. Accelerated corrosion treatment (130 deg. C, 95% relative humidity, 6 h) was performed on Ta-capped Sm(CoCu){sub 5} thin films. X-ray photoelectron spectroscopy (XPS) results showed that no Co was detected on the sample surface before the corrosion treatment, but strong XPS signals of CoOx and Co(OH)x were observed after treatment. Therefore, none of our Sm(CoCu){sub 5} thin films can pass the accelerated corrosion test. Hcp-phased CoPt-alloys are proposed as better capping materials for Sm(CoCu){sub 5} thin films in future high-density magnetic recording applications.

36 MATERIALS SCIENCE↗

Electroplating hard magnetic SmCo for magnetic microactuator applications

Patterned SmCo thin films were electroplated from an aqueous solute containing glycine by using dc and pulse dc current on the beaker level. Micromolds prepared by photolithography allow an accurate pattern transfer for patterned deposition of the material. A flux guide of a magnetic microactuator was chosen as a pattern, and Al{sub 2}O{sub 3} was used as the substrate. Au and Cr were investigated as seed layer materials. The content of Sm in the SmCo films is strongly dependent on the applied cathodic current density. A relative Sm content of up to 13.8 at. % could be determined by energy dispersive x-ray (EDX) spectroscopy. The SmCo thin films were annealed at 560 deg. C in a vacuum oven. Vibrating sample magnetometer (VSM) measurements were applied to characterize the magnetic properties. This film features hard magnetic properties with an intrinsic coercivity H{sub ci} of up to 44 kA/m. Electron probe microanalysis (EPMA) measurements showed that up to 40 at. % of O may be integrated in these films. The phases in the deposited films were determined by applying X-ray diffraction (XRD) measurements. These films consist of a mixture of SmCo alloy, Sm oxide, and Co.

36 MATERIALS SCIENCE↗

A strong magneto-optical activity in rare-earth La{sup 3+} substituted M-type strontium ferrites

M-type strontium ferrites with substitution of Sr{sup 2+} by rare-earth La{sup 3+} were prepared by conventional ceramic technology. The structure, magnetic properties, and magneto-optical Kerr activity of Sr{sub 1-x}La{sub x}Fe{sub 12}O{sub 19} (x = 0, 0.05, 0.10, 0.15, 0.20) were investigated by x-ray diffraction (XRD), vibrating sample magnetometer (VSM), and magneto-optical ellipsometry, respectively. X-ray diffraction showed that the samples sintered at 1290 deg. C for 3 h were single M-type hexagonal ferrites. The magnetic properties were remarkably changed due to the valence change of Fe ions induced by the substitution of La ions. Most significantly, an important magneto-optical activity was induced in the La{sup 3+} substituted M-type strontium ferrites around 3 eV.

36 MATERIALS SCIENCE↗

Magnetic Properties of Electroformed Ni and Ni-Fe for Micromagnetic MEMS Applications

This paper reports a new technique which is based on electroforming process for high permeability Ni and Ni-Fe alloy. The magnetic properties of Ni and Ni-Fe alloy are investigated as a function of plating current density via scanning electron microscope (SEM), energy dispersive spectroscopy (EDS), and vibrating sample magnetometer (VSM). Concentration-dependent kinetics is used to formulate the deposition rate and also the same is verified by using finite element analysis tool COMSOL Multiphysics. Several experiments are performed to derive the relation between electroplating parameters and magnetic properties. The process conditions are optimized to develop high permeability (∼16000) Ni-Fe alloy (85.71–14.29 %). The higher current density shows a monotonically increasing behavior of relative permeability (μ{sub r}). In addition, the B-H curves indicate that the saturation magnetization (B{sub sat}) increases and coercivity decreases with increasing plating current density. Our experimental data confirms that the higher current density increase the softness of Ni. The observed properties of Ni and Ni-Fe based on experimental results can be used to study the magnetic behavior of micromagnetic sensors and large force actuators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural and Magnetic Studies of Nano-crystalline Ferrites MFe{sub 2}O{sub 4} (M = Zn, Ni, Cu, and Co) Synthesized Via Citrate Gel Autocombustion Method

Nano-crystalline ferrites with the chemical formula MFe{sub 2}O{sub 4} (M = Zn, Ni, Cu, and Co) were synthesized via autocombustion route with citric acid as fuel. The ratio of citric acid to metal nitrate was taken as 1:1. The synthesized samples were characterized by powder X-ray diffraction and far-IR spectroscopy. The measured lattice constants and observed characteristic IR absorption bands of all samples were in good agreement with the reported values and showed the formation of a cubic spinel structure. The crystallite sizes of all samples were determined using high-intensity peaks and a W-H plot. The crystallite sizes of all samples were observed to be in the range of 16–26 nm with the least crystallite size of 16.8 nm for copper ferrite. All structural parameters were calculated using an experimental lattice constant and an oxygen positional parameter and correlated with far-IR results. Zinc and copper owing to their large cation radii showed the expansion of the lattice in view of the oxygen positional parameter. Magnetic measurements were carried out using a vibrating sample magnetometer at room temperature, and parameters such as saturation magnetization, coercivity, remanence, squareness ratio, and Bohr magnetons were calculated. Among all synthesized nano-ferrites, cobalt nano-ferrite showed the highest saturation magnetization of 41 emu/g, whereas zinc ferrite displayed a low saturation magnetization value of 12.87 emu/g.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanostructural Characterization of the Fe{sub 3}O{sub 4}/ZnO Magnetic Nanocomposite as an Application in Medicine

In the present work, we synthesize Fe{sub 3}O{sub 4}/ZnO nanocomposite by sol-gel method using iron nitrate, ethylene glycol, zinc acetate dehydrate, and ammonium carbonate as precursors. Amorphous matrix and crystalline grains were formed in composite as well. The nanostructural properties of the nanocomposite were characterized by X-ray diffraction (XRD), Fourier transform infrared (FTIR), X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), transmission electron microscopy (TEM), vibrating sample magnetometer (VSM), and colloidal stability was checked out by Zeta potential. The biological effects of Fe{sub 3}O{sub 4}/ZnO nanocomposite were investigated by microculture tetrazolium test (MTT) against MCF-7 breast cancer cells as usage in medicine. Crystallite size, lattice strain, and dislocation density of the nanoparticles were estimated with Williamson-Hall method. The obtained results show that the highest death rate of Michigan Cancer Foundation-7 (MCF-7) cancer cells was for Fe{sub 3}O{sub 4}/ZnO nanocomposite with the molar ratio is 1:10 in the lower concentration (49 μ g/ml). Therefore, these nanocomposites due to their small size, colloidal stability, magnetic properties, and nontoxicity can be a good candidate as option in medicine application.

60 APPLIED LIFE SCIENCES↗

Study on Microwave Performance of Low-Temperature Sintered, Ba(CoTi){sub 1.5}Fe{sub 9}O{sub 19} Ferrite for Application at UHF Frequency

M-type barium ferrite, Ba(CoTi){sub 1.5}Fe{sub 9}O{sub 19}, was synthesized via the solid-state reaction method. BBSZ, i.e., B{sub 2}O{sub 3} −Bi{sub 2}O{sub 3} −SiO{sub 2} −ZnO, was added to adjust the sintering temperature to values lower than that of silver (i.e., ∼961 °C). The phase formation characteristics, microstructure, magnetic, and microwave properties were characterized by x-ray diffraction, scanning electron microscope, vibrating sample magnetometer, and impedance analyzer, respectively. The results show that densification of samples were enhanced by increasing the amount of BBSZ with corresponding gains realized in magnetic properties. Such enhanced properties in Ba(CoTi){sub 1.5}Fe{sub 9}O{sub 19} are attributed to the low-melting point experienced as the result of BBSZ glass additives which gave rise to the stabilization of a liquid phase during sintering.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of Chromium Substitution on Structural and Magnetic Properties of Nickel-Cobalt Ferrite Nanoparticles Synthesized by Co-precipitation Method

Ni{sub 0.3}Co{sub 0.7}Cr{sub x}Fe{sub 2−x}O{sub 4} (x = 0, 0.2, 0.4, and 0.6) nanoparticles were synthesized by co-precipitation method followed by annealing treatment. The structural and magnetic properties of the samples were determined by X-ray diffraction (XRD), Fourier transform infrared (FT-IR) spectroscopy, thermogravimetric and differential scanning calorimetry (TG-DSC) analysis, and a vibrating sample magnetometer (VSM) at room temperature. The XRD patterns revealed a single-phase cubic spinel structure for all the annealed products. The average crystallite size is in the range of 45–60 nm. Cation distribution by XRD analysis indicated that Cr{sup 3+} ions preferentially replace Fe{sup 3+} ions from the octahedral sites due to their favorable crystal field effects; with increasing Cr content, it was observed that Co{sup 2+} migrated from octahedral sites to tetrahedral sites. The decrease in saturation magnetization with the increase in Cr concentration could be attributed to reduction in the super-exchange interaction between the A and B sublattices. The observed decrease in coercivity can be explained by reduction in magneto-crystalline anisotropy that resulted from migration of Co{sup 2+} ions from B sites to A sites with the increase in Cr content.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗