At least 217 records · Page 12

Aircraft instrumentation system for the remote sensing of carbon monoxide

A light twin-engine aircraft has been instrumented with a carbon monoxide remote gas sensor system and test flown over the Southern Lake Michigan basin during August, 1976. The remote sensor is based on the gas filter correlation technique. The radiance levels from the sensor along with the data on the surface temperature, air temperature, dewpoint, and altitude were digitized and recorded on seven-track magnetic tape. Air samples were collected at various altitudes over selected sites for later analysis of carbon monoxide concentration and comparison with the inferred concentration from the remote sensor. The values of carbon monoxide obtained from the air samples and the values inferred from the remote sensor for data collected over water are in good agreement.

Beck, S. M.↗

Digital tape unit test facility software

Two computer programs are described which are used for the collection and analysis of data from the digital tape unit test facility (DTUTF). The data are the recorded results of skew tests made on magnetic digital tapes which are used on computers as input/output media. The results of each tape test are keypunched onto an 80 column computer card. The format of the card is checked and the card image is stored on a master summary tape via the DTUTF card checking and tape updating system. The master summary tape containing the results of all the tape tests is then used for analysis as input to the DTUTF histogram generating system which produces a histogram of skew vs. date for selected data, followed by some statistical analysis of the data.

Jackson, J. T.↗

Recovery and Calibration of Legacy Underground Nuclear Test Seismic Data from the Leo Brady Seismic Network

The Leo Brady Seismic Network (LBSN, originally the Sandia Seismic Network) was established in 1960 by Sandia National Laboratories to monitor underground nuclear tests (UGTs) at the Nevada National Security Site (NNSS, formerly named the Nevada Test Site). The LBSN has been in various configurations throughout its existence, but it has generally been comprised of four to six stations at regional distances (~150–400 km) from the NNSS with approximately evenly spaced azimuthal coverage. Between 1962 and the end of nuclear testing in 1992, the LBSN—and a sister network operated by Lawrence Livermore National Laboratories—was the most comprehensive United States source of regional seismic data of UGTs. Approximately 75% of all UGTs performed by the United States occurred in the predigital era. At that time, LBSN data were transmitted as frequency-modulated (FM) audio over telephone lines to a central location and recorded as analog waveforms on high-fidelity magnetic audio tapes. These tapes have been in dry temperature-stable storage for decades and contain the sole record of this irreplaceable data; full waveforms of LBSN-recorded UGTs from this era were not routinely digitized or otherwise published. We have developed a process to recover and calibrate data from these tapes. First, we play back and digitize the tapes as audio. Next, we demodulate the FM “audio” into individual waveforms. We then estimate the various instrument constants through careful measurement of “weight-lift” tests performed prior to each UGT on each instrument. Finally, these coefficients allow us to scale and shape the derived instrument response of the seismographs and compute poles and zeros. Finally, the result of this process is a digital record of the recorded seismic ground motion in a modern data format, stored in a searchable database. To date, we have digitized tapes from 592 UGTs.

58 GEOSCIENCES↗

Use of thermal-infrared imagery in ground-water investigations in Montana

Thermal infrared imagery was used to locate ground-water inflow along three streams and one lake in Montana. The thermal scanner used in May 1972, March 1973, and November 1975 was mounted in a twin-engined aircraft. On the 1973 and 1975 flights, the data were recorded in an analog format on magnetic tape in flight, later were converted to digital format, and were computer processed using an assignment of patterns to indicate differences in water temperature. Output from the image processing program was converted to a temperature map having an isotherm spacing of 0.5 C. Computerization was found to be the most efficient method to manipulate data from lakes, large rivers, and narrow sinuous streams.

Boettcher, A. J.↗

Results of a Loran-C flight test using an absolute data reference

A closed circuit flight test was conducted in the Boston area using VOR's and NDB's as reference points. The Loran-C data collected during the flight was then compared against a reference provided by the Discrete Address Beacon System (DABS) facility at Lincoln Laboratories. A MIT crew used a commercial receiver and recorded Loran-C time differences which would also be compared with the data provided by the DABS facility and eventually with the data collected by Ohio University. The Ohio University low-cost receiver was used for this test which was conducted in the Ohio University DC-3 flying laboratory. The Loran-C time-difference data was recorded with a microcomputer data collection system and stored on magnetic tape for subsequent analysis. The MIT receiver was also on board the DC-3, and recorded its data on a cassette tape which was later used by the MIT crew for data analysis. The equipment configuration in the aircraft, the flight procedure and the results obtained from the data collected with Ohio University's receiver and recording system are described.

Fischer, J. P.↗

The reduction, verification and interpretation of MAGSAT magnetic data over Canada

Procedures were established to select quiet, least-disturbed MAGSAT data in an effort to study the magnetic field originating in the solid Earth. A preliminary map of scalar field anomalies over Canada and adjacent regions was produced. Data from Fort Churchill magnetic observatory (an auroral zone station) were used in classifying MAGSAT passes as quiet, unsettled, or disturbed. Determinations of long-term quiet levels at Canadian magnetic observatories are being made. For the time interval of each MAGSAT pass, the deviations of the mean hourly values of the magnetic field components are determined from these quiet levels, in particular for Fort Churchill. Primary processing all CHRONINT tapes received to date, involved decoding orbit records, decimating data records, selecting time intervals and latitude intervals, and producing output tapes carrying records with data point time, position and magnetic information. Subsequent processing converts the coordinate system from geocentric to geodetic and removes a reference field.

Coles, R. L.↗

Magnetic tape transport for high reliability in space

Studies of tape recorder failure modes in spacecraft tape-recorder applications reveal that failures within the mechanical transport package far outnumber those of the associated electronics. It would, therefore, be desirable to simplify the transport mechanism and to separate the moving parts with a continuously fresh supply of a single inert lubricant medium. The suggestion is made to replace the ball bearings with hydrostatically pressurized fluid film bearings.

Hoffman, J. K.↗

Wind tunnel investigation of a simulated gunship helicopter engine-exhaust-windstream interaction

A wind tunnel investigation of the engine exhaust and windstream flow interaction on a gunship helicopter model was conducted in the Langley V/STOL tunnel. The investigation utilized a flow visualization technique employing neutrally buoyant helium filled bubbles to determine the cause of exhaust shield overheating during cruising flight and to evaluate means of eliminating the problem. The flow patterns were recorded with still cameras and on television magnetic tape. Exhaust flow impingement on the exhaust shield during cruise was found to cause the problem. Several flow altering devices were evaluated to find suitable ways to correct the problem. A flow deflector located on the model cowling upstream of the exhaust provides an effective solution.

Wilson, J. C.↗

Process air quality data

Air quality sampling was conducted. Data for air quality parameters, recorded on written forms, punched cards or magnetic tape, are available for 1972 through 1975. Computer software was developed to (1) calculate several daily statistical measures of location, (2) plot time histories of data or the calculated daily statistics, (3) calculate simple correlation coefficients, and (4) plot scatter diagrams. Computer software was developed for processing air quality data to include time series analysis and goodness of fit tests. Computer software was developed to (1) calculate a larger number of daily statistical measures of location, and a number of daily monthly and yearly measures of location, dispersion, skewness and kurtosis, (2) decompose the extended time series model and (3) perform some goodness of fit tests. The computer program is described, documented and illustrated by examples. Recommendations are made for continuation of the development of research on processing air quality data.

Butler, C. M.↗

The Mees CCD imaging spectrograph

The Mees CCD (MCCD0 instrument is an imaging spectroscopy device which uses the 25-cm coronagraph telescope and the 3.0-m Coude spectrograph at Mees Solar Observatory on Haleakala, Maui. The instrument works with resolving power up to about 200,000 with significant throughput from 3934 A (Ca II K) to about 10,000 A. A fast guiding active mirror stabilizes the image during observations. A rapidly writing magnetic tape storage system allows observations to be recorded at 256 kbytes/s. Currently, the MCCD is used for imaging spectroscopy of solar flares at 6563 A (H-alpha), and velocity measurements of umbral oscillations; future plans include emission line studies of active region coronae, and photospheric studies of solar oscillations.

Penn, Matthew J.↗

Design of Fluxgate Sensors for Different Applications from Geology to Medicine

In this study, we have shown that fluxgate sensors can be used for different application areas. Alternative sensor configurations have been developed for three different application areas. These are mainly rod- and ring-type fluxgate sensors. In the first study, a measurement system with the rod-type fluxgate sensor has been developed in order to monitor the local magnetic field distributions on a magnetic tape (e.g., credit card). With this system, the magnetic recording data on the credit card were measured and imaged successfully. The second and the third application areas, which are monitoring the influence of solar storms on the earth field and heartbeat analysis of mankind, were carried out by using a ring-core fluxgate sensor geometry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of an airborne laser bathymeter

An airborne laser depth sounding system was built and taken through a complete series of field tests. Two green laser sources were tried: a pulsed neon laser at 540 nm and a frequency-doubled Nd:YAG transmitter at 532 nm. To obtain a depth resolution of better than 20 cm, the pulses had a duration of 5 to 7 nanoseconds and could be fired up to at rates of 50 pulses per second. In the receiver, the signal was detected by a photomultiplier tube connected to a 28 cm diameter Cassegrainian telescope that was aimed vertically downward. Oscilloscopic traces of the signal reflected from the sea surface and the ocean floor could either be recorded by a movie camera on 35 mm film or digitized into 500 discrete channels of information and stored on magnetic tape, from which depth information could be extracted. An aerial color movie camera recorded the geographic footprint while a boat crew of oceanographers measured depth and other relevant water parameters. About two hundred hours of flight time on the NASA C-54 airplane in the area of Chincoteague, Virginia, the Chesapeake Bay, and in Key West, Florida, have yielded information on the actual operating conditions of such a system and helped to optimize the design. One can predict the maximum depth attainable in a mission by measuring the effective attenuation coefficient in flight. This quantity is four times smaller than the usual narrow beam attenuation coefficient. Several square miles of a varied underwater landscape were also mapped.

Kim, H., H.↗

Low resolution radar digital interface

This document describes the design and operation of a low resolution radar data recording system for precipitation measurements. This system records a full azimuth scan on seven track magnetic tapes every five minutes. It is designed to operate on a continuous basis with operator intervention required only for changing tape reels and calibration.

Source record↗