Aircraft instrumentation system for the remote sensing of carbon monoxide
A light twin-engine aircraft has been instrumented with a carbon monoxide remote gas sensor system and test flown over the Southern Lake Michigan basin during August, 1976. The remote sensor is based on the gas filter correlation technique. The radiance levels from the sensor along with the data on the surface temperature, air temperature, dewpoint, and altitude were digitized and recorded on seven-track magnetic tape. Air samples were collected at various altitudes over selected sites for later analysis of carbon monoxide concentration and comparison with the inferred concentration from the remote sensor. The values of carbon monoxide obtained from the air samples and the values inferred from the remote sensor for data collected over water are in good agreement.