Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC SHIELDING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Neutronics analysis of spin-polarized fuel in spherical tokamaks

The effect of spin-polarized deuterium–tritium fuel on the blanket, magnets, and surrounding structures is analyzed for a spherical tokamak fusion power plant. The focus of this paper is the neutron flux distribution in the fusion device and the corresponding engineering considerations, such as tritium breeding ratio (TBR) and magnet fluence. Significant benefits were found for anti-aligned polarization: a 2.7% increase in the total TBR (which could increase significantly with further optimization) and an approximately 68% increase in the magnet lifetime. If the inboard breeding blanket can be replaced with extra shielding and magnets, then it could significantly increase fusion power with no loss of magnet lifetime. This would be accomplished by increasing the toroidal field strength.

fusion↗

Percolation theory and quantum critical systems: A new description of the critical behavior in Ce(Ru{sub 0.24}Fe{sub 0.76}){sub 2}Ge{sub 2}

The onset of ordering in quantum critical systems is characterized by a competition between the Kondo shielding of magnetic moments and the ordering of these moments. We show how a distribution of Kondo shielding temperatures—resulting from chemical doping—leads to critical behavior whose main characteristics are given by percolation physics. With the aid of Monte Carlo computer simulations, we are able to infer the low temperature part of the distribution of shielding temperatures in heavily doped quantum critical Ce(Ru{sub 0.24}Fe{sub 0.76}){sub 2}Ge{sub 2}. Based on this distribution, we show that the ordering dynamics—such as the growth of the correlation length upon cooling—can be understood by the spawning of magnetic clusters. Our findings explain why the search for universal exponents in quantum critical systems has been unsuccessful: the underlying percolation network associated with the chemical doping of quantum critical systems has to be incorporated in the modeling of these quantum critical systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Status of the plasma generator of the superconducting proton linac

In the framework of the superconducting proton linac (SPL) study at CERN, a new non-cesiated H{sup -} plasma generator driven by an external 2 MHz RF antenna has been developed and successfully operated at repetition rates of 50 Hz, pulse lengths of up to 3 ms, and average RF powers of up to 3 kW. The coupling efficiency of RF power into the plasma was determined by the cooling water temperatures and the analysis of the RF forward and reflected power and the antenna current and amounts to 50%-60%. The plasma resistance increases between 10 kW and 40 kW RF power from about 0.45 {Omega} to 0.65 {Omega}. Measurements of RF power dissipated in the ferrites and the magnets on a test bench show a 5-fold decrease of the power losses for the magnets when they are contained in a Cu box, thus validating the strategy of shielding the magnets with a high electrical conductivity material. An air cooling system was installed in the SPL plasma generator to control the temperatures of the ferrites despite hysteresis losses of several Watts.

43 PARTICLE ACCELERATORS↗

Molecular NMR shieldings, J -couplings, and magnetizabilities from numeric atom-centered orbital based density-functional calculations

This paper reports and benchmarks a new implementation of nuclear magnetic resonance shieldings, magnetizabilities, and J-couplings for molecules within semilocal density functional theory, based on numeric atom-centered orbital (NAO) basis sets. NAO basis sets are attractive for the calculation of these nuclear magnetic resonance (NMR) parameters because NAOs provide accurate atomic orbital representations especially near the nucleus, enabling high-quality results at modest computational cost. Moreover, NAOs are readily adaptable for linear scaling methods, enabling efficient calculations of large systems. Here, the paper has five main parts: (1) It reviews the formalism of density functional calculations of NMR parameters in one comprehensive text to make the mathematical background available in a self-contained way. (2) The paper quantifies the attainable precision of NAO basis sets for shieldings in comparison to specialized Gaussian basis sets, showing similar performance for similar basis set size. (3) The paper quantifies the precision of calculated magnetizabilities, where the NAO basis sets appear to outperform several established Gaussian basis sets of similar size. (4) The paper quantifies the precision of computed J-couplings, for which a group of customized NAO basis sets achieves precision of ~Hz for smaller basis set sizes than some established Gaussian basis sets. (5) The paper demonstrates that the implementation is applicable to systems beyond 1000 atoms in size.

74 ATOMIC AND MOLECULAR PHYSICS↗

An Investigation into the Electromagnetic Interactions between a Superconducting Torus and Solenoid for the Jefferson Lab 12 GeV Upgrade

The Jefferson Lab 12 GeV Upgrade in Hall B will need CLAS12 detector that requires two superconducting magnets. One is a magnet system consisting of six superconducting trapezoidal racetrack-type coils assembled in a Toroidal configuration (Torus) and the second is an actively shielded solenoidal magnet (Solenoid). Both the torus and solenoid are located in close proximity to one another and are surrounded by sensitive detectors. This paper investigates the electromagnetic interactions between the two systems during normal operation as well as during various fault scenarios as part of a Risk Assessment and Mitigation (RAM).

Torus, actively shielded, Solenoid, SSC-NbTi,Ruthe↗

Structural Design and Thermal Analysis for Thermal Shields of the MICE Coupling Magnets

A superconducting coupling magnet made from copper matrix NbTi conductors operating at 4 K will be used in the Muon Ionization Cooling Experiment (MICE) to produce up to 2.6 T on the magnet centerline to keep the muon beam within the thin RF cavity indows. The coupling magnet is to be cooled by two cryocoolers with a total cooling capacity of 3 W at 4.2 K. In order to keep a certain operating temperature margin, the most important is to reduce the heat leakage imposed on cold surfaces of coil cold mass assembly. An ntermediate temperature shield system placed between the coupling coil and warm vacuum chamber is adopted. The shield system consists of upper neck shield, main shields, flexible connections and eight supports, which is to be cooled by the first stage cold heads of two ryocoolers with cooling capacity of 55 W at 60 K each. The maximum temperature difference on the shields should be less than 20 K, so the thermal analyses for the shields with different thicknesses, materials, flexible connections for shields' cooling and structure design for heir supports were carried out. 1100 Al is finally adopted and the maximum temperature difference is around 15 K with 4 mm shield thickness. The paper is to present detailed analyses on the shield system design.

42 ENGINEERING↗

Compact ExB mass separator for heavy ion beams

A compact ExB mass separator that deflects beam by 30 deg. has been designed and built to prove its principle of operation. The main part of the separator is contained in a shielding box of 11 cm long, 9 cm wide, and 1.5 cm high. An electromagnet of 7 cm pole diameter produced variable magnetic field in the mass separation region instead of a couple of permanent magnets which is to be used in the final design. The experimental result agreed well with the theoretical prediction, and larger mass ions is bent with less magnetic field with the aid of the deflection electric field. The reduction in resolving power for mass separation due to the deflection electric field has been investigated experimentally.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FMEA on the superconducting torus for the Jefferson Lab 12 GeV accelerator upgrade

As part of the Jefferson Lab 12GeV accelerator upgrade project, Hall B requires two conduction cooled superconducting magnets. One is a magnet system consisting of six superconducting trapezoidal racetrack-type coils assembled in a toroidal configuration and the second is an actively shielded solenoidal magnet system consisting of 5 coils. Both magnets are to be wound with Superconducting Super Collider-36 NbTi strand Rutherford cable soldered into a copper channel. This paper describes the various failure modes in torus magnet along with the failure modes that could be experienced by the torus and its interaction with the solenoid which is located in close proximity.

43 PARTICLE ACCELERATORS↗

Jefferson Lab CLAS12 Superconducting Solenoid magnet Requirements and Design Evolution

As part of the Jefferson Lab 12GeV accelerator upgrade project, one of the experimental halls (Hall B) requires two superconducting magnets. One is a magnet system consisting of six superconducting trapezoidal racetrack-type coils assembled in a toroidal configuration and the second is an actively shielded solenoidal magnet system consisting of 5 coils. In this presentation the physics requirements for the 5 T solenoid magnet, design constraints, conductor decision, and cooling choice will be discussed. The various design iterations to meet the specification will also be discussed in this presentation.

Rajput-Ghoshal, Renuka↗

Options for Shielding Tokamak Cooling Water Electrical Components against High Magnetic Fields

The Tokamak Cooling Water System (TCWS) Instrumentation and Control (I&C) components of ITER will be located in areas of relatively high magnetic fields. Previous tests on electrical and I&C components have indicated that shielding will be required to protect these components from such magnetic fields. To accomplish this, studies were performed by AREVA Federal Services (AFS) in support of the TCWS Design project with the intent of identifying an optimal solution for shielding I&C components. This report presents a summary of these studies and presents design options for providing magnetic shielding to ITER TCWS I&C components and electrical equipment that are susceptible to the magnetic fields present.

Korsah, Kofi↗

A magnetic diagnostic suite for the Pegasus-III experiment

Pegasus-III is an ultralow aspect ratio spherical tokamak providing a dedicated US experiment for comparative solenoid-free startup studies. A new magnetic diagnostic suite for equilibrium and low frequency (<200 kHz) magnetohydrodynamic mode analysis has been installed. These new diagnostics address the significant challenges of measuring magnetic field in a high noise environment with the majority constrained to fit in an 8 mm diagnostic gap on the high field side. Electrostatic switching noise generated by the 16 independent current feedback-controlled power supplies produces dV cm /dt ~ 1 kV/μs and volt level common mode noise on the magnetics. Immunity to this switching noise is accomplished through differential signal runs and signal processing, along with end-to-end electromagnetic interference shielding. The magnetic measurements are simultaneously digitized at 1 MHz and conditioned by precision 8 pole Butterworth filters with a corner frequency of 200 kHz to prevent aliasing down to the 16-bit level over the full passband. Ex-vessel calibrations of the B p coils were completed with a typical uncertainty of <0.5%. Stray toroidal field pickup from coil misalignment or positioning errors is corrected using a physics-based model. Comparisons of the corrected measurements to modeling agree to within 1.3% on average. This is within the 1.5% measurement uncertainty that a sensitivity analysis determined is needed for accurate fast boundary and equilibrium reconstruction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase and Frequency Locked Magnetron

Phase and Frequency locked magnetrons have many important uses from phased array ground penetrating radars to SRF sources. We report on the recent progress in making such a magnetron. The ferrite/garnet material has passed bakeout and outgassi ng tests with outgassing rates well below the requirements. The magnetic field requirements for adjusting the frequency by changing the microwave properties of the ferrite/garnet have been determined. The design of the anode structure with ferrites, magne tic shielding, and magnetic bias has been completed for a low power test. We report on the design status. Muons, Inc. has negotiated an contract with a manufacturing firm, L-3 Electron Devices California Tube Laboratory, Inc., to be the Manufacturing Part ner for the commercialization of this technology and support these Phase II efforts.

43 PARTICLE ACCELERATORS↗

A co-axial electron gun to generate millimeter-wave RF using the two-stream instability

A novel source for broadband millimeter-wave RF is being designed at Los Alamos National Laboratory utilizing the two-stream instability. This RF source offers the potential for consistent output power over a large bandwidth on a single device. The source is designed to use two co-axial electron beams coupled into solenoidal magnetic fields. This is accomplished using two cathodes independently modulated nested in each other. The electron beam energy from the innermost cathode will fall in the range between 15 and 20 keV with the beam energy from the outer cathode being 75%–95% of the inner beam energy. In order to efficiently match the beam from the outer cathode into the solenoidal magnetic field, shields are used around the cathodes to shape the electric field in the gun region to extend the electrostatic focal length of the beams for better coupling into the magnetic field. As a result, we present the design of electron guns and expected performance using Trak simulations.

47 OTHER INSTRUMENTATION↗

Simulations for preliminary design of a multi-cathode DC electron gun for eRHIC

The proposed electron ion collider, eRHIC, requires a large average polarized electron current of 50 mA, which is more than 20 times higher than the present experimental output of a single, highly polarized electron source, based on cesiated super-lattice GaAs. To meet eRHIC's requirement for current, we designed a multicathode DC electron gun for injection. The twenty-four GaAs cathodes emit electrons in sequence, then are combined on axis by a rotating field (or 'funnelled'). In addition to its ultra-high vacuum requirements, the multicathode DC electron gun will place high demand on the electric field symmetry, the magnetic field shielding, and on preventing arcing. In this paper, we discuss our results from a 3D simulation of the latest model for this gun. The findings will guide the actual design in future. Their preliminary design of a multi-cathode electron source for eRHIC demonstrated tolerable fields and reasonable results in both field and particle simulations.

43 PARTICLE ACCELERATORS↗

Non-perturbative calculation of molecular magnetic properties within current-density functional theory

We present a novel implementation of Kohn–Sham density-functional theory utilizing London atomic orbitals as basis functions. External magnetic fields are treated non-perturbatively, which enable the study of both magnetic response properties and the effects of strong fields, using either standard density functionals or current-density functionals—the implementation is the first fully self-consistent implementation of the latter for molecules. Pilot applications are presented for the finite-field calculation of molecular magnetizabilities, hypermagnetizabilities, and nuclear magnetic resonance shielding constants, focusing on the impact of current-density functionals on the accuracy of the results. Existing current-density functionals based on the gauge-invariant vorticity are tested and found to be sensitive to numerical details of their implementation. Furthermore, when appropriately regularized, the resulting magnetic properties show no improvement over standard density-functional results. An advantage of the present implementation is the ability to apply density-functional theory to molecules in very strong magnetic fields, where the perturbative approach breaks down. Comparison with high accuracy full-configuration-interaction results show that the inadequacies of current-density approximations are exacerbated with increasing magnetic field strength. Standard density-functionals remain well behaved but fail to deliver high accuracy. The need for improved current-dependent density-functionals, and how they may be tested using the presented implementation, is discussed in light of our findings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of a weakly 3-D equilibrium on ideal magnetohydrodynamic instabilities

The effect of a small three-dimensional equilibrium distortion on an otherwise axisymmetric configuration is shown to be destabilizing to ideal magnetohydrodynamic modes. The calculations assume that the 3-D fields are weak and that shielding physics is present so that no islands appear in the resulting equilibrium. An eigenfunction that has coupled harmonics of different toroidal mode number is constructed using a perturbation approach. The theory is applied to the case of tokamak H-modes with shielded resonant magnetic perturbations (RMPs) present indicating RMPs can be destabilizing to intermediate-n peeling-ballooning modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Relativistic theory of nuclear spin-rotation tensor with kinetically balanced rotational London orbitals

Both kinetically balanced (KB) and kinetically unbalanced (KU) rotational London orbitals (RLO) are proposed to resolve the slow basis set convergence in relativistic calculations of nuclear spin-rotation (NSR) coupling tensors of molecules containing heavy elements [Y. Xiao and W. Liu, J. Chem. Phys. 138, 134104 (2013)]. While they perform rather similarly, the KB-RLO Ansatz is clearly preferred as it ensures the correct nonrelativistic limit even with a finite basis. Moreover, it gives rise to the same “direct relativistic mapping” between nuclear magnetic resonance shielding and NSR coupling tensors as that without using the London orbitals [Y. Xiao, Y. Zhang, and W. Liu, J. Chem. Theory Comput. 10, 600 (2014)].

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗