Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Lower Body Negative Pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Biomedical technical transfer. Applications of NASA science and technology

Lower body negative pressure testing in cardiac patients has been completed as well as the design and construction of a new leg negative unit for evaluating heart patients. This technology is based on NASA research, using vacuum chambers to stress the cardiovascular system during space flight. Additional laboratory tests of an intracranial pressure transducer, have been conducted. Three new biomedical problems to which NASA technology is applicable are also identified. These are: a communication device for the speech impaired, the NASA development liquid-cooled garment, and miniature force transducers for heart research.

Source record↗

Effect of prolonged space flight on cardiac function and dimensions

By taking advantage of the capabilities of echocardiography to measure noninvasively left ventricular volume, stroke volume, and ejection fraction, and of the fact that the astronauts were routinely subjected to lower body negative pressure (whereby cardiac filling is progressively decreased), it was possible to construct classic ventricular function curves noninvasively, thereby obviating the difficulties encountered in comparing cardiac function at different end-diastolic volumes preflight and postflight. In this manner, the effect of an 84-day period of weightlessness on cardiac structure and function was evaluated in the Skylab 4 astronauts.

Henry, W. L.↗

Determination of cardiac size from chest roentgenograms following Skylab missions

The majority of crewmembers who exhibited postflight decreases in the cardiac silhouette size also showed a decreased orthostatic tolerance to lower body negative pressure. Similar findings were also reported by the Soviet investigators following 30-day bedrest studies and in cosmonauts upon return from space missions. Further radiological data from all three Skylab manned missions are presented and the physiological factors possibly involved in the cardiac silhouette changes are discussed.

Nicogossian, A. E.↗

Vectorcardiograph

A system for quantitating the cardiac electrical activity of Skylab crewmen was required for three medical experiments (M092, Lower Body Negative Pressure; M171, Metabolic Activity; and M093, In-flight Vectorcardiogram) designed to evaluate the effects of space flight on the human cardiovascular system. A Frank lead vectorcardiograph system was chosen for this task because of its general acceptability in the scientific community and its data quantification capabilities. To be used effectively in space flight, however, the system had to meet certain other requirements. The system was required to meet the specifications recommended by the American Heart Association. The vectorcardiograph had to withstand the extreme conditions of the space environment. The system had to provide features that permitted ease of use in the orbital environment. The vectorcardiograph system performed its intended function throughout all the Skylab missions without a failure. A description of this system follows.

Lintott, J.↗

Cardiovascular studies using the chimpanzee (Pan troglodytes)

Despite the phylogenetic similarities between chimpanzees and man, there exists a paucity of reliable data on normal cardiovascular function and the physiological responses of the system to standard interventions. Totally implanted biotelemetry systems or hardwire analog techniques were used to examine the maximum number of cardiovascular variables which could be simultaneously monitored without significantly altering the system's performance. This was performed in order to acquire base-line data not previously obtained in this species, to determine cardiovascular response to specific forcing functions such as ventricular pacing, drug infusions, and lower body negative pressure. A cardiovascular function profile protocol was developed in order to adjust independently the three major factors which modify ventricular performance, namely, left ventricular performance, left ventricular preload, afterload, and contractility. Cardiac pacing at three levels above the ambient rate was used to adjust end diastolic volume (preload). Three concentrations of angiotensin were infused continuously to evaluate afterload in a stepwide fashion. A continuous infusion of dobutamine was administered to raise the manifest contractile state of the heart.

Hinds, J. E.↗

Application and effectiveness of prophylactic devices in model experiments

Material is presented for evaluating the effectiveness of prophylactic devices intended for maintaining: a relatively high functional level of the cardiovascular system; the nerve and muscle apparatus; and the water and salt status. The effects of the following are analyzed: physical training, lower body negative pressure, regulation of water and salt consumption, pharmacological preparations, and a combination of these. The author points out the need for further research.

Kakurin, L. I.↗

Specialized physiological studies in support of manned space flight

Breath-by-breath measurements of pulmonary capillary O2 transfer and ventilation with a box-balloon spirometer and mass spectrometer were made on 3 subjects before, during and after 10 min of lower body negative pressure (LBNP) at -20, -40 and -60 Torr with arterial samples at -60 Torr. Deficits in blood O2 stores (O2B) were noted during LBNP with repayment of O2B during recovery being related to the intensity of LBNP stress. Concurrent calf volume, measured with a Hg strain gauge, decreased towards baseline well before the peak rise in pulmonary capillary O2 transfer after the release of LBNP which signified that O2B changes were related to blood volume shifts. The return of O2-depleted pooled blood to the central circulation during the first min. of recovery caused significant stress-related hyperpnea which peaked near 30 sec. and returned to near baseline after the first min. Three-compartment lung model analyses indicated an increase in the ventilated unperfused lung fraction from 0.09 to 0.17 with the effective compartment decreasing from 0.83 to 0.77. It appears that the 30% increase in ventilation equivalent was primarily the result of less effective lung perfusion during the LBNP.

Source record↗

Physiological responses of women to simulated weightlessness: A review of the first female bed-rest study

Subjects were exposed to centrifugation, to lower body negative pressure (LBNP), and to exericse stress both before and after bed rest. Areas studied were centrifugation tolerance, fluid electrolyte changes and hematology, tolerance to LBNP, physical working capacity, biochemistries, blood fibrinolytic activity, female metabolic and hormonal responses, circadian alterations, and gynecology. Results were compared with the responses observed in similarly bed-rested male subjects. The bed-rested females showed deconditioning responses similar to those of the males, although with some differences. Results indicate that women are capable of coping with exposure to weightlessness and, moreover, that they may be more sensitive subjects for evaluating countermeasures to weightlessness and developing criteria for assessing applicants for shuttle voyages.

Sandler, H.↗

User's instructions for the GE cardiovascular model to simulate LBNP and tilt experiments, with graphic capabilities

The present form of this cardiovascular model simulates both 1-g and zero-g LBNP (lower body negative pressure) experiments and tilt experiments. In addition, the model simulates LBNP experiments at any body angle. The model is currently accessible on the Univac 1110 Time-Shared System in an interactive operational mode. Model output may be in tabular form and/or graphic form. The graphic capabilities are programmed for the Tektronix 4010 graphics terminal and the Univac 1110.

Source record↗

Fluid volumes changes induced by spaceflight

The blood volume (BV), plasma volume (PV), and extracellular fluid volume changes produced in crewmembers during spaceflights of 11-84 days were compared to changes after 14 or 28 days of bedrest. Spaceflight and bedrest produce approximately equal BV changes but the recorded PV change after spaceflight was less. However, the diurnal change in PV may explain the smaller decreases recorded after spaceflight. The cardiovascular deconditioning caused by spaceflight and bedrest was compared using the mean heart rate response to lower body negative pressure (LBNP) testing at -50 mmHg pressure. These tests show approximately equal LBNP produced heart rate changes after bedrest and spaceflight. A countermeasure which includes 4 hr of LBNP treatment at -30 mmHg and the ingestion of one l. of saline was studied and found capable of returning the heart rate response and the PV of bedrested subjects to control (prebedrest) levels suggesting that it would be useful to the crewmembers after a spaceflight.

Johnson, P. C.↗

Interactions between surface cooling and LBNP-induced central hypovolemia

The paper describes a study carried out to determine the extent to which whole body surface cooling (WBSC) modifies the effects of the central hypovolemia produced by lower body negative pressure (LBNP) at normal skin temperatures. It is shown that WBSC produces a central displacement of cutaneous venous volume resulting in an increase in stroke volume.

Raven, P. B.↗

Instantaneous stroke volume by PDE during and after constant LBNP (-50 torr)

Six male subjects were exposed to -50 torr lower body negative pressure (LBNP) for 10 min while stroke volume was recorded beat by beat at regular intervals before, during and after release of LBNP. Stroke volume was calculated from the systolic velocity integral in the ascending aorta by pulsed Doppler echocardiography (PDE) and the cross sectional area of the vessel by M mode echocardiography. Changes in leg volume were recorded continuously and blood pressure was taken every minute. Stroke volume dropped by 51% of the control in the first 33 sec of LBNP and continued to decline slowly to -62% toward the end. Heart rate increased by 15% in the first 10 sec and was 22% above control at the end of exposure. The resulting cardiac output closely followed the course of stroke volume (-47% at 33 sec, -53% at 8 min) showing that the modest increase in heart rate did little to offset the drop in stroke volume. Leg volume increased markedly within the first 10 sec with a more gradual rise reaching +3.5% at the end. Upon sudden release of LBNP, leg volume dropped significantly during the first 3 sec simultaneously with an increase in stroke volume followed by a substantial decline in heart rate below the baseline.

Source record↗

Changes in cardiac output and tibial artery flow during and after progressive LBNP

A 3.0 MHz Pulsed Doppler velocity meter (PD) was used to determine blood velocities in the ascending aorta from the suprasternal notch before, during and after progressive 5 min stages of lower body negative pressure (LBNP) in 7 subjects. Changes in stroke volume were calculated from the systolic velocity integrals. A unique 20 MHz PD was used to estimate bloodflow in the posterior tibial artery. With -20 torr mean stroke volume fell 11% and then continued to decline by 48% before LBNP was terminated. Mean tibial flow fell progressively with LBNP stress, due to an increase in reverse flow component and a reduction in peak forward flow and diameter. Stroke volume increased and heart rate fell dramatically during the first 15 sec of recovery. The LBNP was terminated early in 2 subjects because of vasovagal symptons (V). During V the stroke volume rose 86% which more than compensated for the drop in heart rate. This implies that V is accompanied by a paradoxical increase in venous return and that the reduction in HR is the primary cardiovascular event. During the first 15 sec of recovery these 2 subjects had a distinctive marked rise to heart rate reminiscent of the Bainbridge reflex.

Source record↗

Cardiovascular adaptations in weightlessness: The influence of in-flight exercise programs on the cardiovascular adjustments during weightlessness and upon returning to Earth

The effect of in-flight exercise programs on astronauts' cardiovascular adjustments during spaceflight weightlessness and upon return to Earth was studied. Physiological changes in muscle strength and volume, cardiovascular responses during the application of lower body negative pressure, and metabolic activities during pre-flight and flight tests were made on Skylab crewmembers. The successful completion of the Skylab missions showed that man can perform submaximal and maximal aerobic exercise in the weightless enviroment without detrimental trends in any of the physiologic data. Exercise tolerance during flight was unaffected. It was only after return to Earth that a tolerance decrement was noted. The rapid postflight recovery of orthostatic and exercise tolerance following two of the three Skylab missions appeared to be directly related to total in-flight exercise as well as to the graded, regular program of exercise performed during the postflight debriefing period.

Bennett, C. H.↗

Cardiovascular responses to weightlessness and ground-based simulations

Mission experience, from NASA and Soviet programs, on human cardiovascular responses to weightlessness, and the ability of bed rest studies to simulate these are discussed. In-flight effects include fluid shift to the upper body, decreased heart size, bone demineralization, orthostatic intolerance, and loss of exercise tolerance. All the cardiovascular changes that occur with weightlessness also occur with prolonged bed rest. They are most manifest when subjects stand suddenly, or undergo tilting or lower body negative pressure. The mechanisms which control these responses, e.g., the role of the central nervous system, are unclear.

Sandler, H.↗

Evaluation of a Reverse Gradient Garment for prevention of bed-rest deconditioning

A Reverse Gradient Garment (RGG) was used to intermittently induce venous pooling in the extremities of a magnitude similar to that seen in going from a lying to standing position during the course of a 15-d period of horizontal bed rest. Venous pooling failed to improve bed-rest-induced losses in +2.5 Gz and +3.0 Gz centrifugation tolerance or to prevent increased heart-rate responses to lower-body negative pressure (LBNP). Four subjects served as controls, four were treated. Tests during the 7-d recovery period showed fluid/electrolyte and body composition values to have returned to pre-bed-rest levels with continued depression of acceleration tolerance times (56% decreased at +2.5 Gz and 74% decreased at +3.0 Gz compared to pre-bed-rest levels) and exaggerated blood insulin response on glucose tolerance testing (blood insulin for treated group increased 95% at 1 h before bed rest and 465% during recovery). This study demonstrates that the physiologic changes after bed rest persist for significant periods of time. Acceleration tolerance time proved to be a sensitive test for the deconditioning process.

Sandler, H.↗

Increased hematuria following hypergravic exposure in middle-aged women

The effects of simulated weightlessness on orthostatic tolerance were studied in 9 women (55 to 65 years old) who underwent acceleration and lower body negative pressure before and after 10 days of horizontal bed rest. The results of this study show the first known association of microscopic hematuria with hypergravic and orthostatic stress which suggests similarities to the 'stress hematuria syndrome' previously seen with heavy exercise (Boileau et al., 1980). In addition, the sporadic occurrence of this phenomenon indicates a multifactorial etiology in predisposed individuals. Bedrest or weightlessness simulation per se does not seem to significantly alter renal function, but may decrease microscopic hematuria with an orthostatic component.

Goldwater, D. J.↗

Cardiovascular responses to hypogravic environments

The cardiovascular deconditioning observed during and after space flight is characterized in a review of human space and simulation studies and animal simulations. The various simulation techniques (horizontal bed rest, head-down tilt, and water immersion in man, and immobilization of animals) are examined, and sample results are presented in graphs. Countermeasures such as exercise regimens, fluid replacement, drugs, venous pooling, G-suits, oscillating beds, electrostimulation of muscles, lower-body negative pressure, body-surface cooling, and hypoxia are reviewed and found to be generally ineffective or unreliable. The need for future space experimentation in both humans and animals is indicated.

Sandler, H.↗