Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Liquid water path”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

211 records · Page 12

Multifrequency radar observations of clouds and precipitation including the G-band

Abstract. Observations collected during the 25 February 2020 deployment of the Vapor In-Cloud Profiling Radar at the Stony Brook Radar Observatory clearly demonstrate the potential of G-band radars for cloud and precipitation research, something that until now was only discussed in theory. The field experiment, which coordinated an X-, Ka-, W- and G-band radar, revealed that the Ka–G pairing can generate differential reflectivity signal several decibels larger than the traditional Ka–W pairing underpinning an increased sensitivity to smaller amounts of liquid and ice water mass and sizes. The observations also showed that G-band signals experience non-Rayleigh scattering in regions where Ka- and W-band signal do not, thus demonstrating the potential of G-band radars for sizing sub-millimeter ice crystals and droplets. Observed peculiar radar reflectivity patterns also suggest that G-band radars could be used to gain insight into the melting behavior of small ice crystals. G-band signal interpretation is challenging, because attenuation and non-Rayleigh effects are typically intertwined. An ideal liquid-free period allowed us to use triple-frequency Ka–W–G observations to test existing ice scattering libraries, and the results raise questions on their comprehensiveness. Overall, this work reinforces the importance of deploying radars (1) with sensitivity sufficient enough to detect small Rayleigh scatters at cloud top in order to derive estimates of path-integrated hydrometeor attenuation, a key constraint for microphysical retrievals; (2) with sensitivity sufficient enough to overcome liquid attenuation, to reveal the larger differential signals generated from using the G-band as part of a multifrequency deployment; and (3) capable of monitoring atmospheric gases to reduce related uncertainty.

54 ENVIRONMENTAL SCIENCES↗

LeaPP: Learning Pathways to Polymorphs through Machine Learning Analysis of Atomic Trajectories

Understanding the mechanisms underlying crystal nucleation and growth is crucial for many technological applications. Due to the short length and time scales involved, crystal nucleation is often studied using molecular simulations. Most existing approaches to extract the nucleation mechanism from simulations focus on the analysis of static snapshots of the configurations, potentially overlooking subtle local fluctuations and the history of the particles involved in the formation of solid nuclei. Here, in this work, we propose a novel methodology called LeaPP that categorizes nucleation trajectories based on the temporal information of their constituent particles. We leverage the time evolution of the local environment of the crystallizing particles to encapsulate the relationship between the structure and dynamics and distinguish between different evolving particle paths. Identification of the distinct particle paths further enables characterizing the nucleation trajectories into different pathways. Collectively, LeaPP provides a more nuanced understanding of nucleation through an unsupervised approach with lesser dependence on traditional order parameters. Furthermore, the pathways identified by LeaPP are predictive of the resulting polymorph. We demonstrate LeaPP on three different systems─Lennard-Jones-like particles, Ni 3 Al, and water on surfaces. The general methodology underlying LeaPP─considering the time evolution of the building blocks─applies to a wide range of self-assembly problems.

36 MATERIALS SCIENCE↗

Assessing parallel path cooling tower performance via artificial neural networks

Real-time monitoring of a research nuclear reactor, a system in which all generated power is dissipated to the environment, can be performed via analysis of the heat rejection from the cooling system. Given an inlet water temperature and flow rate, the reactor power can be well-approximated from the outlet water temperature; however, the instrumentation to measure outlet conditions may not be robust or accurate. If we know how a cooling tower performs from historical data, but cannot measure the outlet temperature, a mathematical representation of the system can be inverted to obtain the outlet water temperature that describes the cooling capacity. Unfortunately, model inversion processes are computationally expensive. To address this, an artificial neural network (ANN) is implemented to assess the performance of a multi-cell cooling tower for a nuclear reactor. This approach leverages the Merkel model to obtain an extensive data set describing performance of the cooling tower cells throughout a wide array of potential operating conditions. The Merkel model is expressed as a function of four parameters: the inlet and outlet water temperatures, inlet air wet bulb temperature, and ratio of liquid-to-gas mass flow rates (L/G), which together provide a non-dimensional number indicative of cooling tower performance, called the Merkel integral. Computing a 4-dimensional data structure that describes finite combinations of the Merkel integral, an inverse model is then generated using an ANN to determine the cell outlet water temperature from the other three model parameters along with the computed Merkel integral. Compared to traditional model inversion methods, the ANN reduces the computational time by approximately 4 orders of magnitude, with effectively no sacrifice to solution accuracy, and could be applied for different cooling towers in the event the performance curve is known. Finally, three use cases of the ANN are then reviewed: (1) determining the cell outlet water temperatures when gas flow at rated conditions (GFRC) is known, (2) performing the prior case without knowledge of the GRFC, and (3) assessing performance differences between the individual tower cells.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development and experimental verification of an active noise cancellation (ANC) method for non-invasive sensing

Ultrasonic wave propagation may be used in non-invasive sensing to identify the properties of a fluid in a container. An ultrasonic excitation can be coupled into the liquid or the gas through the walls of the container and detected by a receiver on the other side. However, in addition to this fluid path, another signal will also propagate through the structure and is referred as noise in this study. For most materials, this structural noise will be of higher amplitude compared to the fluid signal due to the large acoustic impedance difference between the solid container and the fluid. In this paper, an active noise cancellation (ANC) method is developed and demonstrated on an experimental setup. It was shown that this method cancels more than 90% of the noise signal in a given time window of interest. A sequential version of this cancellation method is also proposed, and it was shown that its performance improves as the number of canceling excitations is increased. The performance was found to be independent of the location of canceling transducers and position of the silence window but dependent on the width of the silence window. As an example, the ANC method was applied to noise cancellation of a signal travelling through water in a stainless-steel container. The signal-to-noise ratio (SNR) of the water signal in the window of interest was increased by 148% from 13.98 dB to 34.68 dB by using the proposed ANC method.

42 ENGINEERING↗

Drop Interactions with the Conical Shock Structure Generated by a Mach 4.5 Projectile

This work presents measurements of liquid drop deformation and breakup time behind approximately conical shock waves and evaluates the predictive capabilities of low-order models and correlations developed using planar shock experiments. A conical shock was approximated by firing a bullet at Mach 4.5 past a vertical column of water drops with a mean initial diameter of $192$ $\mu$m. The time-resolved drop position and maximum transverse dimension were characterized using backlit stereo images taken at 500 kHz. The gas density and velocity fields experienced by the drops were estimated using a Reynolds-averaged Navier–Stokes simulation of the bullet. Classical correlations predict drop breakup times and deformation in error by a factor of 3 or more. The Taylor analogy breakup (TAB) model predicts deformed drop diameters that agree within the confidence bounds of the ensemble-averaged experimental values using a dimensionless constant $C$ 2 = $2$ compared to the accepted value $C$ 2 = $2/3$. In conclusion, results demonstrate existing correlations are inadequate for predicting the drop response to the three-dimensional relaxation of the flowfield downstream of a conical-like shock and suggest the TAB model results represent a path toward improved predictions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Geophysical Characterization and Monitoring of the 200 Area Treated Effluent Disposal Facility to Support Permit Renewal; TEDF Geophysical Monitoring

The Treated Effluent Disposal Facility (TEDF), located in the 200 East Area of the Hanford Site, is a site where non-hazardous and non-radioactive liquid wastes are disposed into two state-permitted infiltration basins. In 2016, the Washington State Department of Ecology denied a permit renewal request for TEDF due to the inability to adequately assess the impact of TEDF discharge water on the underlying groundwater quality. TEDF overlies the relatively impermeable Ringold Lower Mud (RLM) unit, whose upper contact lies in the vadose zone approximately 30 m below ground surface and approximately 10 m above the water table boundary. The RLM is assumed to isolate TEDF discharge water from the natural groundwater aquifer, which is monitored using wellbores screened below the RLM. Therefore, samples collected from monitoring wells near TEDF are not considered representative of TEDF discharge water. Rather, TEDF discharge water is assumed to mound on top of the RLM to form a perched aquifer. To support permitting of the TEDF, a new monitoring well is required that can be used to sample water from the presumed perched water aquifer above the RLM. Ideally, the screened section of the well would be located at the peak of the perched water mound(s), which presumably occurs at the point of maximum vertical flux from TEDF to the RLM, or equivalently where the dominant infiltration flow paths reach the RLM. This report describes how time-lapse 3D electrical resistivity tomography (ERT) was used in conjunction with nominal TEDF discharge operations to image the dominant flow paths from each pond to the RLM. Results are summarized in Figure ES.1. Figure ES.1A shows a satellite image of the TEDF overlain by an array of surface ERT electrodes. The solid and dashed black circles denote the zones of maximum vertical flux at the RLM within the south and north ponds, respectively, and presumably the regions where perched water peaks during discharge. Figure ES.1B shows time-lapse difference imaging results approximately 15 days after switching discharge from the south pond to the north pond. Blue iso-surfaces beneath the north pond denote regions of increasing bulk electrical conductivity caused by increasing saturation due to infiltrating water. Red iso-surfaces beneath the south pond denote regions that were previously saturated during the south pond discharge and are now de-saturating, causing a decrease in bulk electrical conductivity. In both cases, the zones of maximum change mark the dominant flow paths to the RLM. Figure ES.1C shows time-lapse imaging results approximately 15 days after switching discharge from the north pond to the south pond. In this case, blue iso-surfaces mark the dominant flow paths to the RLM from the south pond. The red iso-surfaces mark the dominant flow paths that existed during discharge to the north pond. The regions of maximum change in bulk conductivity (due to saturation or desaturation) that mark the primary flow paths are equivalent in both cases and denoted by the dashed solid and black circles. If a perched water zone forms on the RLM, it is likely to mound within or near the dashed circle during discharge to the north pond, and in the solid circle during discharge to the south pond. In other words, if perched water mounding occurs, the circles mark the optimum locations suggested by the ERT imaging for monitoring boreholes to be placed, enabling samples to be collected that are representative of TEDF discharge impacts on groundwater quality.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Numerical modeling and performance analysis of a membrane-based air dehumidifier using ionic liquid desiccant

Membrane-based Liquid Desiccant Air Dehumidifier (MLDAD) has the potential to overcome the shortcomings of the conventional open-tower liquid desiccant air dehumidifier. The MLDAD uses membranes with high water vapor permeability to separate air stream from the liquid desiccant and thus eliminates carry-over and the resulting corrosion issues. Recently, the ionic liquid desiccant becomes a promising alternative to conventional liquid desiccant. The ionic liquid desiccant has a large potential of dehumidification, which is also non-corrosive to metals and non-crystallizable. A two-dimensional numerical heat and mass transfer model of the MLDAD using a recently identified ionic liquid desiccant, [EMIM]OAc, is presented here. This model can simulate the performance of the MLDAD with various designs, including different selections of liquid desiccant and membrane materials, dimensions of the MLDAD, and flow patterns. For porous membranes, this model accounts for several micro-scale mass transfer mechanisms of vapor transportation across the membrane. It can also model the mass transfer performance of dehumidifiers using non-porous membranes based on the experimentally measured membrane permeance. The numerical model was validated against the performance data available from literature and experimental tests. The maximum discrepancy of the latent effectiveness between the measured and the model-predicted results was about 6% when porous membranes were used. A parametric study was conducted with the numerical model. Finally, the results indicated that the membrane permeability, air path height, and solution to air mass ratio were the most critical parameters, determining the dehumidification performance of the MLDAD.

42 ENGINEERING↗

Numerical modeling and performance analysis of a membrane-based air dehumidifier using ionic liquid desiccant

Membrane-based Liquid Desiccant Air Dehumidifier (MLDAD) has the potential to overcome the shortcomings of the conventional open-tower liquid desiccant air dehumidifier. The MLDAD uses membranes with high water vapor permeability to separate air stream from the liquid desiccant and thus eliminates carry-over and the resulting corrosion issues. Recently, the ionic liquid desiccant becomes a promising alternative to conventional liquid desiccant. The ionic liquid desiccant has a large potential of dehumidification, which is also non-corrosive to metals and non-crystallizable. A two-dimensional numerical heat and mass transfer model of the MLDAD using a recently identified ionic liquid desiccant, [EMIM]OAc, is presented in this paper. We report this model can simulate the performance of the MLDAD with various designs, including different selections of liquid desiccant and membrane materials, dimensions of the MLDAD, and flow patterns. For porous membranes, this model accounts for several micro-scale mass transfer mechanisms of vapor transportation across the membrane. It can also model the mass transfer performance of dehumidifiers using non-porous membranes based on the experimentally measured membrane permeance. The numerical model was validated against the performance data available from literature and experimental tests. The maximum discrepancy of the latent effectiveness between the measured and the model-predicted results was about 6% when porous membranes were used. A parametric study was conducted with the numerical model. The results indicated that the membrane permeability, air path height, and solution to air mass ratio were the most critical parameters, determining the dehumidification performance of the MLDAD.

42 ENGINEERING↗

Spectroscopic features of dissolved iodine in pristine and gamma-irradiated nitric acid solutions

While iodine speciation is important for a wide range of nuclear activities, understanding the mechanisms of the transformations of iodine between chemical forms and the sensitivity of these transitions to solution conditions and exposure to radiation remains an active area of research. This work curates spectroscopic data from several experimental techniques and establishes their sensitivity and limitations in detecting changes in iodine speciation in both neutral and acidic regimes. The techniques include Raman spectroscopy, Fourier Transform Infrared (FTIR) spectroscopy, 127 I NMR spectroscopy, and ultraviolet-visible (UV-Vis) spectroscopy. Analysis of these data indicates that these commonly accessible spectroscopies often have dynamic ranges of measurable concentrations that do not always overlap between all techniques. The experimental techniques are disparately sensitive to iodide (I - ), molecular iodine (I 2 ), iodate (IO 3 - ), and periodate (IO 4 - ) species. Raman, FTIR, and NMR spectra were subsequentially analyzed using two-dimensional correlation analyses to generate high-resolution autocorrelation spectra. Here, the use of these spectroscopies is then extended to tracking acidification-induced and gamma irradiation-induced transformations of dissolved sodium iodate in deionized water and concentrated nitric acid. Both dissolution into nitric acid and irradiation with a gamma source are demonstrated to perturb the iodine speciation promoting their assembly into molecular iodine (I 2 ) and/or triiodide (I 3 - ). While I 2 and I 3 - species are undetectable with FTIR spectroscopy and 127 I NMR spectroscopy, the species can be detected with UV-Vis spectroscopy, and in some instances, I 3 - can be detected with Raman spectroscopy in the low wavenumber region. Ultimately, the results of this work provide a path to designing optimal combinations of techniques to detect forms of iodine across a wide range of concentrations and conditions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Plasma breakdown in bubbles passing between two pin electrodes

The ignition of plasmas in liquids has applications from medical instrumentation to manipulation of liquid chemistry. Formation of plasmas directly in a liquid often requires prohibitively large voltages to initiate breakdown. Producing plasma streamers in bubbles submerged in a liquid with higher permittivity can significantly lower the voltage needed to initiate a discharge by reducing the electric field required to produce breakdown. The proximity of the bubble to the electrodes and the shape of the bubbles play critical roles in the manner in which the plasma is produced in, and propagates through, the bubble. In this paper, we discuss results from a three-dimensional direct numerical simulation (DNS) used to investigate the shapes of bubbles formed by injection of air into water. Comparisons are made to results from a companion experiment. A two-dimensional plasma hydrodynamics model was then used to capture the plasma streamer propagation in the bubble using a static bubble geometry generated by the DNS The simulations showed two different modes for streamer formation depending on the bubble shape. In an elliptical bubble, a short electron avalanche triggered a surface ionization wave (SIWs) resulting in plasma propagating along the surface of the bubble. In a circular bubble, an electron avalanche first traveled through the middle of the bubble before two SIWs began to propagate from the point closest to the grounded electrode where a volumetric streamer intersected the surface. In an elliptical bubble approaching a powered electrode in a pin-to-pin configuration, we experimentally observed streamer behavior that qualitatively corresponds with computational results. Optical emission captured over the lifetime of the streamer curve along the path of deformed bubbles, suggesting propagation of the streamer along the liquid/gas boundary interface. Plasma generation supported by the local field enhancement of the deformed bubble surface boundaries is a mechanism that is likely responsible for initiating streamer formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

RELAP-7 Application and Enhancement for FLEX Strategies and ATF Behavior under Extended Loss of AC Power Conditions

This report summarizes the results of a three-year research project sponsored by the U.S. Department of Energy (DOE) Nuclear Energy University Program (NEUP) to enhance and apply the RELAP-7 code by adding and improving several important components (e.g., a mechanistic Reactor Core Isolation Cooling (RCIC) system model) for thermal hydraulic studies of LWRs under ELAP conditions and evaluating the time available for transition to portable FLEX equipment. The project team included University of Massachusetts–Lowell, The Ohio State University, Texas A&M University, Idaho National Laboratory and Oak Ridge National Laboratory. In the Fukushima accident, it was found that the RCIC system played a crucial role in delaying core meltdown by almost three days in Fukushima Daiichi Unit 2, because of self-regulated operation of the steam driven RCIC turbine-pump injection system. Steam flow in the convergent-divergent nozzles of the RCIC Terry turbine is two-phase non-equilibrium transonic flow with homogenous nucleation condensation. To more accurately predict the dynamic process and behavior of the transonic compressible steam flow, a one-dimensional transient two-phase analytical model is presented. A simplified four-fluid model was employed in the present work with the consideration of four separate fluid fields: vapor, liquid film, entrained droplets and condensed droplets. The mass, momentum and energy interactions between the fluids were considered and modeled. An extended seven-equation non-equilibrium critical flow model was developed to obtain the critical pressure and velocities of each phase at the nozzle throat. To predict the wetness in the divergent section, a mechanistic nucleation condensation model was integrated in the nozzle analysis model, considering the generation and consequent growth of droplets. The governing differential equations on a staggered grid were discretized using the second-order Lax-Wendroff scheme with a flux limiter, and the Semi-Implicit Method for Pressure-Linked Equation (SIMPLE) algorithm was employed to solve the discrete linear system. To demonstrate the predictability and reliability of the physical models and the numerical method proposed in the present work, three representative nozzles were modeled and simulated. The results show good agreement with the available experimental data, even for condensation shock. Then, the 1D nozzle model was employed to obtain nozzle flow tables of the Terry turbine nozzle for different working pressures which can cover the operation pressure range of the RCIC system. A mechanistic RCIC turbine-pump system model was developed and implemented in the system code TRACE to simulate dynamic responses of the RCIC system under Beyond Design Basis Accident (BDBA) conditions. The turbine-pump governing equations are based on the control volume approach of the angular momentum balance. The physics based mechanistic RCIC model was developed using the TRACE control system components (i.e., signal variables, control blocks, and tables), and incorporated into a TRACE boiling water reactor (BWR) model. The TRACE model in this report has a detailed nodalization of the reactor pressure vessel (RPV), and all of the major flow paths and system components, including the safety relief valves (SRVs) and the containment suppression pool and drywell. Based on the nozzle flow tables generated from the 1D nozzle model developed, the turbine drive torque can be calculated from table lookup. Since the detailed specifications of the RCIC pump are unavailable, the homologous curves for a Bingham pump were used in the current pump component. A station black-out (SBO) accident test problem was selected to demonstrate the TRACE RCIC model. The short-term SBO simulations were performed for two cladding materials: Zircaloy and FeCrAl, to demonstrate the effect of the accident tolerant fuel cladding on fuel heat-up under BDBA accident conditions. The wetwell plays a vital safety role in SBO and other BWR accident scenarios in that it can reduce containment pressure and supply additional core make-up water. The suppression pool temperature distribution has a very large impact on both RPV and containment pressure. Thus, another novel contribution of the project comes mainly from an improved, systems-level wetwell model which can capture buoyancy-induced thermal stratification effects due to steam injection and condensation. A two-zone stratified wetwell model has been implemented in RELAP-7 and some results from that model are presented. This wetwell model is capable of simulating thermal stratification due to a low steam mass injection rate. With a low mass flow rate, the model assumes that all the steam condenses within the pipe and the resulting plume can be approximated with a purely buoyant, heat-source driven model. The wetwell model developed with these assumptions is adequate to simulate slow transients such as extended SBO transients.

42 ENGINEERING↗

High Efficiency and Transient Air Systems for Affordable Load-Following Heavy Duty Truck Fuel Cells

Hydrogen fuel cell powered vehicles are one of the potential paths to reducing vehicle emissions. An important subsystem of the hydrogen fuel cell system is an air handling system that provides the needed oxygen (in air) to react with hydrogen in the fuel cell stack for electric power generation. Today’s systems use an electric motor to power an air compressor that supplies oxygen to the fuel cell stack. This process requires significant electrical power and is the largest parasitic power loss in hydrogen fuel cell vehicles. In addition to parasitic power loss, hydrogen fuel cell systems often have reliability issues associated with the air handling system. Reliability is of significant concern for heavy duty applications (especially long-haul applications). This project aims to improve both the electrical power consumption and reliability of hydrogen fuel cell air handling systems to meet the needs of heavy duty on-highway vehicle applications.

08 HYDROGEN↗

Report on Year-4 of Water NSTF Matrix Testing: Facility Maintenance and Accident Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report serves as a summary of maintenance and experimental activities during the program’s fourth year of water-based operation. A planned six-month maintenance period began in August 2021, during which major inspections, repairs, cleaning, and installation of new instrumentation and data acquisition hardware were conducted. Most significantly, two heaters that faulted during Year-3 were repaired, allowing the facility to resume use of the full heated section area and full range of available electric power. The remainder of the year consisted of eight months of test operations, during which the facility logged 211 hours of active heating across one bake-out (following the maintenance period) and seven matrix tests; five classifieds as Accepted per NQA-1, one as Trending, and one as Failed. Testing began by performing two repeat cases to confirm expected facility response and behavior during both single- and two-phase flow conditions, ensuring no changes were introduced during the maintenance period that might have altered the thermal-hydraulic characteristics of the facility. In continuation of the power parametric series initiated in previous years, a high-power test case was then performed examining heat removal performance at a decay heat load equivalent to 2.4 MWt, full-scale, a level exceeding maximum design targets. Additional testing then introduced various blockage scenarios along the network piping, examining the effects of partial and complete blockages of the flow paths on the system behavior and heat removal performance. A study of static boiling tests directed at understanding the geysering two-phase instability was also conducted. The loop was filled only to the bottom of the tank outlet, creating an open loop configuration that prevents any natural circulation flow from occurring, and the heaters were powered on until the facility reached saturation conditions. Following, a series of quasi-steady-state conditions were introduced by adjusting the inventory level in the adiabatic chimney piping at decreasingly lower elevations above the heated region. A strong correlation of geysering characteristics and loop level was observed, with flow and temperature excursions decreasing in intensity, but increasing in frequency, as the fill were reduced to lower elevations along the chimney piping. Once the level fell very low in the chimney, at points near the top of the heated section, the system reached a stable state of continuous boiling without any occurrence of geysering eruptions. A final significant testing accomplishment this year was successful completion of an “accident scenario” test, whose operating conditions were based on a prototypic decay heat curve provided by Framatome and scaled for the NSTF. This test began by establishing steady-state, single-phase “normal operation” conditions, before simulating an accident trip where the availability of active cooling systems was lost. Loop temperatures gradually increased until reaching saturation and subsequent two-phase boiling flow. Over the course of an extended operational period along the defined decay heat curve, steam boil-off caused gradual but continued depletion of liquid inventory until reaching a critically low level causing flow stagnation and cessation of natural circulation heat removal. At this point, after nearly 72 hours of continuous operation, a cold refill was performed to replenish the system inventory and allow the facility to re-establish closed loop natural circulation flow and return to a safe operational state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗