Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Levelized Cost of Electricity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Antenna optimization of single beam microwave systems for the solar power satellite

A generalized antenna design technique is applied to the unique environmental requirements pertaining to solar power satellite (SPS) systems. Optimal illumination tapers and antenna/rectenna sizings are generated which allow increased transmit powers and lower electricity costs while minimizing sidelobe levels to meet a 0.01 mW/sq cm environmental standard. These optimal tapers also provide other advantages over the 10 dB Gaussian reference system.

Kerwin, E. M.↗

Thermal and Well Flow Performance of Closed-Loop Geothermal in the Wattenberg Area: Preprint

Closed-loop geothermal systems provide an alternative to resource-constrained hydrothermal systems and stimulation-intensive enhanced geothermal systems. In this work, we apply the slender-body theory (SBT) model, to simulate the well flow and heat transfer performance of U-loop well designs drilled in the Wattenberg area of the Denver-Julesburg Basin. Three U-loop well patterns are investigated including a single, double, and multi-lateral design. The subsurface within area is characterized by deep, hot (> 200degreesC) igneous/metamorphic basement rock underlying multiple sedimentary formations. The lateral section(s) of the U-loop lies within a target depth of 6 km where temperatures are estimated to approach 300degreesC. As a base case, conduction-only heat transfer is investigated through simulations with the SBT model within U-loops with open-hole laterals that exchange heat directly with the hot dry rock using water as a working fluid. The utilization of supercritical CO2 as a heat transfer fluid is also considered. For each scenario, the system performance in terms of annual heat production and temperature profile over a 20-year project lifetime are assessed. Also, the levelized costs of heat and electricity (LCOH and LCOE) are determined using a top-down technoeconomic analysis model. The results show that the performance and cost optimized U-loop design is one having an injection-production well spacing of 1,000 meters with ten 50-meter-spaced laterals that traverse a subsurface system with a temperature gradient of 60degreesC/km. By injecting 20 degreesC-water at a rate of 60 kg/s through this loop, an average heat production of 19 MWth can be achieved, resulting in an LCOE and LCOH of $136/MWh and $1.53/GJ, respectively, over a 20-year project life.

closed-loop geothermal↗

Quantifying Investment Risk: Analysis of the Purchase Decision of a Nuclear Power Plant

Cost overruns are an ill-fated part of the deployment history of nuclear power plants (NPPs) in the United States, and yet studies increasingly show the important role nuclear technologies must play in decarbonizing the U.S. economy. Paradoxically, then, a key piece of a coherent decarbonization strategy depends on attracting investor action to a purchase where historical cost overruns have been sizeable. To address this challenge, this study aims to develop a financial model that quantifies risk of cost overruns in the decision-making process for purchasing advanced reactor concepts. Using the concept of Value at Risk (VaR), the model is built to evaluate financial risk nuclear construction with the aim to identify risk mitigation strategies. The objective is to identify strategies to mitigate cost-risk challenges and to assess the potential reduction in investor risk exposure. The paper presents the initial development and preliminary verification of the financial risk analysis model. The development of this model involved a comprehensive approach to estimating financial risk over the operating life of NPP that stems from construction uncertainties. By utilizing net present value (NPV) with discounted cash flows, the model captures the complex interconnections of project costs, construction timelines, revenue, and uncertainties. Verification of the model involved testing historical data from previous reactor construction projects against the construction project of Vogtle 3 and 4. The results of this paper present the comparison of the preconstruction cost overrun prediction with the current cost estimates from a nearly complete Vogtle 3 and 4.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Thermal and Well Flow Performance of Closed-Loop Geothermal in the Wattenberg Area

Closed-loop geothermal systems provide an alternative to resource-constrained hydrothermal systems and stimulation-intensive enhanced geothermal systems. In this work, we apply the slender-body theory (SBT) model, to simulate the well flow and heat transfer performance of U-loop well designs in the Wattenberg area of the Denver-Julesburg Basin. Three U-loop well patterns are investigated, including a single-, double-, and multi-lateral design. The subsurface within the area of interest is characterized by deep, hot (> 200 degrees C) igneous/metamorphic basement rock underlying multiple sedimentary formations. The lateral section(s) of the U-loop lie(s) within a target depth of 6 km, where temperatures are estimated to approach 300 degrees C. As a base case, conduction-only heat transfer is investigated through simulations with the SBT model within U-loops with open-hole laterals that exchange heat directly with the hot, dry rock using water as a working fluid. The utilization of supercritical CO2 as a heat transfer fluid is also considered. For each scenario, the system performance in terms of annual heat production and temperature profile over a 20-year project lifetime are assessed. Also, the levelized costs of heat and electricity (LCOH and LCOE) are determined using a top-down techno-economic analysis model. The results show that the performance- and cost-optimized U-loop design is one having an injection-production well spacing of 1,000 meters with ten 50-meter-spaced laterals that traverse a subsurface system with a temperature gradient of 60 degrees C/km. By injecting 20 degrees C-water at a rate of 60 kg/s through this loop, an average heat production of 19 MWth (i.e., 2.2 MWe net plant output) can be achieved, resulting in an LCOE and LCOH of $136/MWhe and $1.53/GJ, respectively, over a 20-year project life.

closed-loop geothermal↗

Cost-effective technology advancement directions for electric propulsion transportation systems in earth-orbital missions

This paper presents the results of a study to determine the directions that electric propulsion technology should take to meet the primary propulsion requirements for earth-orbital missions of the next three decades in the most cost-effective manner. Discussed are the mission set requirements, state-of-the-art electric propulsion technology and the baseline system characterized by it, adequacy of the baseline system to meet the mission set requirements, cost-optimum electric propulsion system characteristics for the mission set, and sensitivities of mission costs and design points to system-level electric propulsion parameters. It is found that the efficiency-specific impulse characteristic generally has a more significant impact on overall costs than specific masses or costs of propulsion and power systems.

Regetz, J. D., Jr.↗

Using Concentrating Solar Power to Create a Geological Thermal Energy Reservoir for Seasonal Storage and Flexible Power Plant Operation

Abstract We propose a hybrid renewable energy system—a geothermal energy storage system (GeoTES) with solar—to provide low-cost dispatchable power at various timescales from daily, to weekly, to seasonally. GeoTES with solar uses a concentrating solar power collector field to produce hot water that is injected into a sedimentary basin to create a synthetic geothermal resource. The stored geothermal heat can then be dispatched when required by the electrical grid. GeoTES is particularly valuable for a grid with a high penetration of non-flexible renewable technologies such as photovoltaic and wind power. In this work, a sophisticated hybrid model is developed to assess the technical and economic potential of GeoTES by combining IPSEpro, which is a power-cycle simulation tool, and SAM, an economic analysis tool by National Renewable Energy Laboratory (NREL). The analysis shows with proper initial charging period that the heat loss in storage is almost negligible and is a suitable technology for long-term energy storage. Various power-cycle options are evaluated, and the most suitable power cycle is selected for further study. Annual calculations of the GeoTES system indicate that a levelized cost of storage (LCOS) of 12.4 ¢/kWh e can be achieved for seasonal storage of 4000 h; this value is much lower than the existing long-term storage. The LCOS of GeoTES is insensitive to the storage duration above 8 h, unlike battery and molten-salt thermal storage systems. This result demonstrates that GeoTES can be a competitive seasonal storage technology in the future electricity market. The levelized cost of electricity of the GeoTES system is also carefully analyzed and can vary between 10.0 and 16.4 ¢/kWh e , depending on solar-collector prices.

25 ENERGY STORAGE↗

Comparative techno-economic assessment of osmotically-assisted reverse osmosis and batch-operated vacuum-air-gap membrane distillation for high-salinity water desalination

New developments in pressure- and thermally driven membrane desalination technologies offer the potential to cost-effectively treat high-salinity waters, especially when powered by low-cost solar electricity and thermal energy. This paper presents a comparative techno-economic assessment of the state-of-the-art most promising pressure- and thermally driven membrane technologies for high recovery desalination, namely, osmotically-assisted reverse osmosis (OARO) and batch-operated vacuum-air-gap membrane distillation (batch V-AGMD), to produce potable water while concentrating brine within the range of 140–290 g/L TDS for minimum-liquid-discharge (MLD) and zero-liquid-discharge (ZLD) applications. It is shown that both OARO and batch V-AGMD can treat feedwater and brines with TDS in the range of 30–125 g/L with corresponding fresh water recovery rates of 85–25%. When low cost solar electricity and thermal energy are used, the resulting levelized cost of water (LCOW) from OARO is in the range of 0.70–6.28 $/m 3 , and that from batch-V-AGMD is in the range of 1.74–2.77 $/m 3 . OARO is more cost-effective than batch V-AGMD when feedwater salinity is below 70 g/L and recovery below 75%, whereas batch V-AGMD is more cost-effective at higher recovery rates and salinity levels. Finally, the sensitivity of this comparison on energy prices and module costs is discussed.

42 ENGINEERING↗

Photovoltaic power - An important new energy option

A review of photovoltaic (PV) power technology is presented with an emphasis of PV as an economical and technically feasible alternative source of energy. The successful completion of the development and transfer of emerging low-cost technologies into a fully commercialized status are identified as the means to the realization of this option's full potential. The DOE National Photovoltaics Program, a significant sponsor of PV R&D, expects both flat-plate and concentrator collectors to meet established cost targets. Citing the DOE large flat-plate grid-connected system project of the Sacramento Municipal Utility District, current technology modules priced at near $5/Wp (1983 dollars) are steadily reducing costs. A recent DOE study suggests that PV-generated electricity produced at a 30-year levelized cost of 15 cents per kWh would represent a viable energy supply alternative for the nation.

Ferber, R. R.↗

Community-scale interaction of energy efficiency and demand flexibility in residential buildings

Demand-side management (DSM) strategies, including energy efficiency (EE) and demand flexibility (DF), contribute to cost-effective operation of the electricity grid. From a system-level perspective, such programs reduce costs, enhance reliability, and reduce network issues. Similarly, DSM programs help participating customers reduce utility bills while maintaining occupant comfort. Understanding the relationship between EE and DF is key to realizing the full potential of DSM programs. In this study, we modeled an all-electric residential community based on a 498-home community that is planned for construction in Fort Collins, Colorado in the United States. We used this community model to study the relationship between different EE measures, including building envelope upgrades and smart appliances, and DF enabled by a home energy management system (HEMS) responding to a time-varying tariff. Various EE levels in the homes – code-minimum, zero energy ready, and even higher levels of envelope efficiency – were simulated. DF is enabled by the HEMS, which coordinates behind-the-meter resources, including flexible building loads, PV, and home battery systems, to minimize utility bills while maintaining occupant comfort. When comparing to the code-minimum homes, EE upgrades alone reduce HVAC energy use during peak hours by up to 50% and the HVAC utility bill by up to $312/year. With the addition of HEMS, the average daily peak demand can be reduced by up to 0.58 MW or 1.2 kW/home in the higher envelope efficiency homes. The combination of EE upgrades, HEMS, and home battery systems is expected to save homeowners up to $590/year while increasing community load flexibility. However, HEMS and home battery systems are less effective in increasing the DF in the more efficient homes due to the lower load.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploring Renewable Energy Opportunities in Select Southeast Asian Countries: A Geospatial Analysis of the Levelized Cost of Energy of Utility-Scale Wind and Solar Photovoltaics

The costs of renewable energy-based electricity generation have fallen precipitously in recent years to levels that are increasingly competitive with traditional generation such as fossil fuel-based generation. As these costs become increasingly competitive, private developers, policymakers, and energy system planners are searching for opportunities to harness high-quality renewable energy resources. Developing economies are setting ambitious targets and exploring how cost-effective, grid-connected renewable energy options can help power economic growth and meet growing electricity demands. This includes the member states of the Association of Southeast Asian Nations (ASEAN) that are determined to reach a target of 23% of renewable energy in the region's total primary energy supply by 2025. A critical gap to identifying opportunities and scaling up renewable energy is the lack of quality data and analyses to support decisions on the investment and deployment of renewables - including wind and solar photovoltaics (PV). This work supports decision making by providing high-quality data and spatial analysis of the cost of utility-scale wind and solar PV generation in select countries of Southeast Asia - specifically, the ASEAN member states. Generation costs are expressed as the levelized cost of energy (LCOE) - a commonly used metric that represents the net present value of the unit cost of electricity during the lifetime of a particular electricity generation technology. This is the first spatial estimate of LCOE for these technologies within the ASEAN member states - providing insights into the roles that renewable energy resource quality and other factors may play in generation costs.

14 SOLAR ENERGY↗

Thermoelectric System Economics - The Apex: New Paradigms in Manufacturing and Interface Performance Relationships Driving System Cost Optimizations

Thermoelectric energy recovery systems require cost-optimized designs with high thermal and thermoelectric (TE) performance to surmount common commercialization barriers controlling the acceptance of thermoelectric generator (TEG) systems. Recent work has addressed this requirement with new analytic tools and paradigms that allow integrated TEG cost-performance analysis and optimization. New work herein has identified the existence of optimized TE element design (i.e., TE element length) for minimizing TEG cost and provides design guidelines associated with critical thermal and electrical contact resistance effects and TE manufacturing sensitivities. Once optimum hot-side heat flux criteria are satisfied, this work highlights the tradeoffs between interface resistance effects and manufacturing cost effects in determining optimum-cost TE element lengths, and then quantifies the increase in optimum-cost TE lengths as manufacturing costs become more sensitive to TE element lengths. Optimized TE element design criteria and key non-dimensional design parameters (i.e., [𝐶′′′LTE/𝐶′′], [TE/con], [con/(TE,aveLTE)]) driving the design are presented and explained showing the interdependencies between manufacturing cost parameters and thermal and electrical interface impacts on integrated TE cost-performance analysis and design. Comprehensive TEG system cost-performance relationships clearly demonstrate the two parameters that most greatly impact the TEG system cost are heat exchanger costs ($/(W/K)) and TE hot side heat flux. Reducing heat exhanger cost from $1/(W/K) to $0.5/(W/K) can decrease TEG system cost by $2/W to $4/W depending on TE hot side heat fluxes from 4-10 W/cm2. The impact of TE hot side heat flux on TEG system cost is larger; reducing TE system cost by factors of 2-4 as TE hot side heat flux increases from 4 W/cm2 to high levels around 18 W/cm2. The levels of thermal contact resistance and electrical contact resistance required to even approach the critical TEG system cost level of $1/W are characterized by con = 1.0 x 10-10 -m2 and r = 0.1, respectively. This not only lowers TEG costs, but it also makes the TEG system costs less sensitive to TE manufacturing dependences on TE element length. New design paradigms and relationships create holistic, integrated TE performance-cost models that enhance understanding of crucial interrelationships between component costs, TE design parameters and material properties, heat exchanger design parameters, interfacial heat flux, and now thermal and electrical interface effects in minimizing TEG system costs.

Hendricks, Terry J.↗

Development of Energy Storage: Cost models

Energy storage technologies offer a promising solution to electric grid stability issues associated with the integration of variable renewable generators. The capability to match the electrical power output to instantaneous fluctuations in grid demand is crucial to ensure continuity of service. Including energy storage capability in an integrated energy system (IES) can provide the flexibility needed to meet variable electric demand and reduce the load following demands place on the reactor. In this report, economic data collected for energy storage (ES) technologies are described to support the objective of assessing the profitability of ES integration within the IES framework. In particular, there is a growing interest in thermal energy storage (TES) given its unique capability for long-duration storage for improving electricity reliability at a low levelized cost. It is common practice to evaluate the total lifetime cost and profitability before commercializing new technologies. In this report we identify and examine the models needed to better understand the economics of thermal energy storage. We extend the TES cost model in RAVEN in the context of a balance of plant (BOP) that incorporates thermal storage. To focus the discussion, following a general overview of the most promising TES technologies, we consider a use case that involves a sensible heat, two-tank, molten-salt system. Structural and operational details are reported to identify the source of construction capital expenditure and operation and maintenance cost. A detailed description of the different cost items is provided as well as the cost scaling with different storage capacity and power ratings for capacity optimization purpose. In addition, the capital expenditure and the recurring cost of representative two-tank, molten salt coupled with concentrated solar plants are provided for readers’ reference. The ES use case is noteworthy as it is in the pilot stage of commercialization. We identify those areas that would benefit from an increased economic focus to obtain a more complete compilation of cost data. We also describe the thermal coupling issues that arise from integration of the two-tank molten salt thermal energy storage system with a BOP, which is the subject of our current research. Some components of costs will need to be evaluated through dedicated technoeconomic analysis in future modeling activities using modeling procedures proposed in this report. With the data presented and the procedures described in this report, sufficiently accurate models can be implemented for the solution of both the power dispatch and the capacity expansion problems within the RAVEN-based HYBRID framework.

25 ENERGY STORAGE↗

Decarbonization scenarios of the U.S. Electricity system and their costs

Decarbonizing the electricity system to zero-carbon emission is crucial for climate change mitigation. Previous studies have shown that such a transition in the United States (U.S.) may lead to higher system cost compared to a business-as-usual case, but it is not well-known how the cost of electricity generation varies at sub-regional level under the transition, and studies have rarely evaluated the trade-off between the cost and avoided climate damages, as well as the potential roles of negative emission technologies (NETs) in the electricity decarbonization. In this work, we present a regionally resolved national model to quantify the cost of decarbonizing the U.S. electricity system under a set of possible scenarios. The results show that, compared to the reference scenario without a decarbonization policy, reaching zero CO 2 emission by 2050 would incur, depending on the scenarios, 335-494 billion USD additional cost to the U.S. electric power sector during 2020-2050. The regional costs of electricity generation ranges from 2.4 to 4.7 cent/kWh, largely due to the generation profiles and renewable resources availability of those regions. The additional costs can be translated to an average CO 2 abatement cost of 29-59 USD/metric ton CO 2 (with 2%-7% discount rates), which are comparable to the social cost of carbon in the literature at around 4% discount rate. The results also show that the cost of mitigating the last few percent CO 2 emission from the U.S. electricity system may exceed the costs of NETs, indicating an opportunity for NETs to contribute to electricity decarbonization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mitigation of Molten Salt Corrosion

The desire to increase the peak operational temperature of Concentrated Solar Power (CSP) plants to lower the levelized cost of CSP-derived electricity, has led to consideration of an earth-abundant, low-cost, thermally-stable, molten MgCl 2 -KCl-NaCl (40-40-20 mole%) salt for high-temperature thermal energy storage and heat transfer. The reliable, long-term containment of such a molten salt is challenging, however, due to the corrosion of cost-effective, high-temperature structural metal alloys in this salt (particularly if this salt is contaminated with oxygen-bearing species). This project has been focused on: i) development of equipment for evaluating corrosion kinetics in molten chlorides under well-controlled thermal, fluid dynamic, and atmospheric conditions at CSP-relevant temperatures, ii) use of such equipment to evaluate the influence of forced convection on corrosion kinetics (to determine the role of liquid phase diffusion on such corrosion), and iii) identifying a corrosion-mitigation strategy that can be industrially applied to achieve a projected annual corrosion ≤30 μm at CSP-relevant temperatures. The overall goals of this project have been: i) to understand the rate-limiting step(s) and associated kinetic laws governing corrosion in molten chlorides at 750°C, ii) to determine key operational parameters affecting the corrosion kinetics in molten salts, and iii) to demonstrate the tailoring of such parameters to appreciably reduce such corrosion.

14 SOLAR ENERGY↗

The dish-Rankine SCSTPE program (Engineering Experiment no. 1)

Activities planned for phase 2 Of the Small Community Solar Thermal Power Experiment (PFDR) program are summarized with emphasis on a dish-Rankine point focusing distributed receiver solar thermal electric system. Major design efforts include: (1) development of an advanced concept indirect-heated receiver;(2) development of hardware and software for a totally unmanned power plant control system; (3) implementation of a hybrid digital simulator which will validate plant operation prior to field testing; and (4) the acquisition of an efficient organic Rankine cycle power conversion unit. Preliminary performance analyses indicate that a mass-produced dish-Rankine PFDR system is potentially capable of producing electricity at a levelized busbar energy cost of 60 to 70 mills per KWh and with a capital cost of about $1300 per KW.

Pons, R. L.↗

Characterizing electrical demand and load diversity of low-power water and space heating appliances in US homes

Home renovation and remodeling projects can involve costly and time consuming electrical infrastructure upgrades at the household level. From the grid perspective they also lead to costly replacement of local infrastructure, such as transformers, and can add stress to the grid at peak times. The emergence of innovative, power-efficient household appliances offers a way to minimize these problems. These appliances are designed for lower power consumption, simplifying installation through standard plug-in connections, reducing the need for new electric circuits/panels/service, and minimizing the peak power demand for the home. Key examples include low-power heat pump water heaters (HPWHs) and cold climate window heat pumps that operate on standard 120V outlets. To assess the real-world impact of these solutions, we compiled and analyzed power metering data from several US field studies. This data provides insights into the effects on peak power demand of selecting lower-power appliances. Our analysis focuses on several key metrics, including the maximum power demand of individual appliances, their operational runtime, continuous operation and load diversity. While individual low-power 120V space and water heating appliances offer significant peak demand reductions compared to 240V heat pump or resistance alternatives, their longer runtimes might increase the likelihood of operation during whole-dwelling peak events, albeit at lower power levels.

Less, Brennan↗

Direct Air Capture Using Trapped Small Amines in Hierarchical Nanoporous Capsules on Porous Electrospun Fibers (Final Technical Report)

This report summarizes the carbon capture research and development conducted by The State University of New York at Buffalo (UB) and GTI Energy (GTI) for award “DE-FE0031969: Direct Air Capture Using Trapped Small Amines in Hierarchical Nanoporous Capsules on Porous Electrospun Fibers” sponsored by the U.S. Department of Energy (DOE). The objective of this project is to develop an innovative sorbent structure of trapped small amines in HNC embedded in PEF for DAC. This involves tailoring both sorbent and PEF materials to achieve a compact system for DAC with high capacity for CO 2 at concentrations typically available in air and at near ambient conditions. An innovative sorbent structure of trapped small amines in hierarchical nanoporous capsules (HNC) embedded in porous electrospun fibers (PEF) was developed for direct air capture (DAC). This involves tailoring both sorbent and PEF materials to achieve a compact system for DAC with high capacity for CO 2 at concentrations typically available in air and at near ambient conditions. An interfacial polymerization process was developed, which utilized loaded amines inside mesoporous silica and trimesoyl chloride (TMC) dissolved in organic solvents as the precursors, to generate a polyamide (PA) coating layer on mesoporous silica and thus trap amines. Reaction conditions, including TMC concentration, organic solvents, reaction time, etc., for interfacial polymerization were optimized to effectively trap loaded amines, and cyclic heating-cooling operation was conducted to evaluate the coating quality. Larger pore volume mesoporous silica was also synthesized to increase amine loading and thus increase CO 2 capacity. The optimized sorbent material exhibited CO 2 capacity as high as 4.88 mmol/g under humid DAC conditions and negligible loss (<1%) during 10 cyclic heating-cooling operations. The optimized PA-coated sorbent also showed fast adsorption and desorption kinetics, with <20% t1/2 increase compared to uncoated sorbent. PEF fabrication conditions, including organic solvents for dissolving core and shell polymers, voltage, distance from the nozzle to the collection panel, etc. were adjusted to better incorporate HNC. After incorporating the optimized sorbent material into PEF, the structured sorbent had a CO 2 capacity of approximately 4.0 mmol/g under humid DAC conditions, with capacity loss of 0.17% per cycle and t1/2 increase less than 10%. A techno-economic analysis (TEA) for the process design for a DAC system based on our developed sorbent structure of trapped small amines in HNC embedded in PEF was conducted. The process design included process description and major equipment sizing and energy and mass balances in addition to scale-up research results and estimated capture cost. Aspen Adsorption Simulator was used to fit the experimentally measured breakthrough curves and extract equilibrium and kinetic data of the optimized sorbent. Our results indicated that for a DAC plant with CO 2 productivity of 3,000 tonne/year, the levelized cost of CO 2 capture was $\$$612/tonne, with the largest contribution of 44.33% from the fixed operation cost. Increasing CO 2 productivity, while maintaining similar fixed operation cost, is expected to significantly reduce the CO 2 capture cost. A sensitivity study was also conducted to understand the influence of total plant cost, sorbent cost, CO 2 concentration in the feed, sorbent mat lifetime, sorbent regeneration electricity, and adsorption blower pressure drop on the levelized cost of CO 2 capture, revealing a capture cost range of $\$$520-870/tonne.

36 MATERIALS SCIENCE↗

EVI-LOCATE: One Stop Solution for Estimating Cost of Installing EV Charging Stations

EVI-LOCATE (Electric Vehicle Infrastructure-Locally Optimized Cost Assessment Tool and Estimator) is a site assessment tool to estimate costs to install EV charging stations. EVI-LOCATE enables users to generate site-specific, user-specific, and location-specific EV charging station installation designs and cost estimates. The tool integrates National Electrical Code, deep-learning pixel classification algorithm, and component-level costs to estimate the costs.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗