Performance of deformed steel fibers embedded in ultra-high performance concrete subjected to various pullout rates

Fiber-matrix bond properties are typically evaluated using a single-fiber pullout test. Such tests for ultra-high performance concrete (UHPC) are few in the literature and, in particular, those that focus on high pullout rates are exceedingly rare. In this research program, different types of high-strength steel fibers (twisted, straight and hooked) are embedded in two UHPC matrices with varying amounts of glass powder, which is a key ingredient of UPHC. The specimens are subjected to loading rates ranging from 0.018 mm/s (representing quasi-static loading) to 1800 mm/s (representing impact loading). Experimental results show that the pullout response of all of the fiber types exhibit progressively increasing rate sensitivity as the pullout speed increases and becomes significant during impact loading. It is most prominent in the smooth and twisted fibers and least in the hooked fibers. Additionally, scanning electron microscope studies are presented and used to explain the mechanism of rate enhancement from a microscopic perspective.

36 MATERIALS SCIENCE↗

Correlation of Tensile Deformation-Induced Strain in HSLA Steel with Residual Stress Distribution

During service, due to the dynamic loading rates encountered, structural components experience varying levels of plastic deformation which leads to changes in the mechanical behavior of materials. The dynamic loading leads to non-homogenous plastic deformation which changes the residual stress distribution. In this study, the magnitude and distribution of residual stress in tensile tested specimens of high-strength low-alloy steel were investigated using x-ray diffraction technique, by varying the deformation rate. Tensile testing was performed at four different strain rates, and residual stress measurement was done along the length of the fractured specimens. Distribution of residual stress was observed all along the length of the specimens which is attributed to the varying levels of plastic deformation. Measured residual stresses are correlated with elastic strain and plastic strain obtained from the tensile tests. Consistent decrease in the magnitude of residual stress with an increase in plastic strain is observed with decreasing strain rate at the necking region. Specimen with lower yield strength experienced higher plastic strains, hence lower elastic residual stresses. The reasons for the observed distribution of residual stress are discussed with XRD peak broadening associated with plastic deformation.

36 MATERIALS SCIENCE↗

Stochastic Dual Algorithm for Voltage Regulation in Distribution Networks with Discrete Loads: Preprint

This paper considers distribution networks with distributed energy resources and discrete-rate loads, and designs an incentive-based algorithm that allows the network operator and the customers to pursue given operational and economic objectives, while concurrently ensuring that voltages are within prescribed limits. Four major challenges include: (1) the non-convexity from discrete decision variables, (2) the non-convexity due to a Stackelberg game structure, (3) unavailable private information from customers, and (4) different update frequency from two types of devices. In this paper, we first make convex relaxation for discrete variables, then reformulate the non-convex structure into a convex optimization problem together with pricing/reward signal design, and propose a distributed stochastic dual algorithm for solving the reformulated problem while restoring feasible power rates for discrete devices. By doing so, we are able to statistically achieve the solution of the reformulated problem without exposure of any private information from customers. Stability of the proposed schemes is analytically established and numerically corroborated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Strain Rate Mechanical Characterization of Carbon Fiber Reinforced Polymer Composites Using Digital Image Correlations

We present that the introduction of carbon fiber reinforced polymer (CFRP) composites to structural components in lightweight automotive structures necessitates an assessment to evaluate that their crashworthiness dynamic response provides similar or higher levels of safety compared to conventional metallic structures. In order to develop, integrate and implement predictive computational models for CFRP composites that link the materials design, molding process and final performance requirements to enable optimal design and manufacturing vehicle systems for this study, the dynamic mechanical response of unidirectional (UD) and 2x2 twill weave CRFP composites was characterized at deformation rates applicable to crashworthiness performance. Non-standardized specimen geometries were tested on a standard uniaxial frame and an intermediate-to-high speed dynamic testing frame, equipped with high speed cameras for 3D digital image correlation (DIC). Specimen cross-sections, according to each fiber orientation tested, were consistent across strain rates to ensure results were comparable. Tensile strength and modulus were experimentally investigated over a wide range of strain rates (0.0001 to 200 s -1 ). DIC was used to estimate strain profiles on composites surfaces, and the modulus was calculated from those strain measurements. Experimental results demonstrated an increase in the tensile strength of UD CFRP composites in the longitudinal (0°) and transverse (90°) direction with increasing strain rates. In contrast, the tensile strength of 2x2 woven composites and the tensile modulus of the UD material were insensitive to increasing strain rates. Finally, comparison of failure modes provided insights on how loading rates influenced failure mechanisms.

36 MATERIALS SCIENCE↗

High-speed X-ray visualization of dynamic crack initiation and propagation in bone

The initiation and propagation of physiological cracks in porcine cortical and cancellous bone under high rate loading were visualized using high-speed synchrotron X-ray phase-contrast imaging (PCI) to characterize their fracture behaviors under dynamic loading conditions. A modified Kolsky compression bar was used to apply dynamic three-point flexural loadings on notched specimens and images of the fracture processes were recorded using a synchronized high-speed synchrotron X-ray imaging set-up. Three-dimensional synchrotron X-ray tomography was conducted to examine the initial microstructure of the bone before high-rate experiments. The experimental results showed that the locations of fracture initiations were not significantly different between the two types of bone. However, the crack velocities in cortical bone were higher than in cancellous bone. Crack deflections at osteonal cement lines, a prime toughening mechanism in bone at low rates, were observed in the cortical bone under dynamic loading in this study. Fracture toughening mechanisms, such as untracked ligament bridging and bridging in crack wake were also observed for the two types of bone. The results also revealed that the fracture toughness of cortical bone was higher than cancellous bone. The crack was deflected to some extent at osteon cement line in cortical bone instead of comparatively penetrating straight through the microstructures in cancellous bone. Statement of Significance Fracture toughness is with great importance to study for crack risk prediction in bone. For those cracks in bone, most of them are associated with impact events, such as sport accidents. Consequently, we visualized, in real-time, the entire processes of dynamic fractures in notched cortical bone and cancellous bone specimens using synchrotron X-ray phase contrast imaging. The onset location of crack initiation was found independent on the bone type. We also found that, although the extent was diminished, crack deflections at osteon cement lines, a major toughening mechanism in transversely orientated cortical bone at quasi-static rate, were still played a role in resisting cracking in dynamically loaded specimen. Furthermore, these finding help researchers to understand the dynamic fracture behaviors in bone.

59 BASIC BIOLOGICAL SCIENCES↗

A Biomechanical Comparison of 1-G and Fully-Loaded Simulated Zero-Gravity Locomotion

Exercise will almost certainly play an integral part in minimizing the bone mineral loss and muscular atrophy that occur during spaceflight. It has been hypothesized that an effective exercise regimen can be developed to elicit loads on the lower extremities and require muscle actions which resemble those encountered on Earth. The Penn State Zero-Gravity Simulator (PSZS) is a device which suspends subjects horizontally from multiple latex cords, with each cord negating the weight of a limb segment. A treadmill mounted on the wall under the PSZS enables subjects to run in simulated 0G. Subjects wear a harness to which a number of springs, which provide a gravity replacement load, are connected. The opposite end of each spring is connected to the side of the treadmill. During exercise, astronauts currently wear a similar harness in which the spring tethering load pulls at both the waist and shoulders. Ground reaction forces, muscular activations, and joint angles of the left leg during overground, treadmill, and fully-loaded zero-gravity simulated (ZLS) locomotion were assessed in order to gain insight into the effectiveness of the exercise regimen used by NASA to prevent the muscular atrophy and bone demineralization which occur in weightlessness. There were three hypotheses to this research. It was hypothesized that there will be no differences in peak ground reaction forces and peak loading rates between overground gait and gait in the full body weight loaded conditions in the ZLS. A second hypothesis was that that there will be no differences in hip, knee, and ankle joint positions between walking or running overground, on a standard treadmill, and in full bodyweight loaded conditions in the ZLS. The third hypothesis was that the muscular activations, as a percentage of maximal voluntary contraction, will be similar between walking or running overground, on a standard treadmill, and in full body-weight loaded conditions in the ZLS.

McCrory, Jean L.↗

NASA/University JOint VEnture (JOVE) Program: Transverse Shear Moduli Using the Torsional Responses of Rectangular Laminates

The first year included a study of the non-visible damage of composite overwrapped pressure vessels with B. Poe of the Materials Branch of Nasa-Langley. Early determinations showed a clear reduction in non-visible damage for thin COPVs when partially pressurized rather than unpressurized. Literature searches on Thicker-wall COPVs revealed surface damage but clearly visible. Analysis of current Analytic modeling indicated that that current COPV models lacked sufficient thickness corrections to predict impact damage. After a comprehensive study of available published data and numerous numerical studies based on observed data from Langley, the analytic framework for modeling the behavior was determined lacking and both Poe and Bogan suggested any short term (3yr) result for Jove would be overly ambitious and emphasis should be placed on transverse shear moduli studies. Transverse shear moduli determination is relevant to the study of fatigue, fracture and aging effects in composite structures. Based on the techniques developed by Daniel & Tsai, Bogan and Gates determined to verify the results for K3B and 8320. A detailed analytic and experimental plan was established and carried out that included variations in layup, width, thickness, and length. As well as loading rate variations to determine effects and relaxation moduli. The additional axial loads during the torsion testing were studied as was the placement of gages along the composite specimen. Of the proposed tasks, all of tasks I and 2 were completed with presentations given at Langley, SEM conferences and ASME/AIAA conferences. Sensitivity issues with the technique associated with the use of servohydraulic test systems for applying the torsional load to the composite specimen limited the torsion range for predictable and repeatable transverse shear properties. Bogan and Gates determined to diverge on research efforts with Gates continuing the experimental testing at Langley and Bogan modeling the apparent non-linear behavior at low torque & angles apparent from the tests.

Bogan, Sam↗

Electric Grid Simulator For Human Factor Research

The developed code simulates real-time monitor and control for west area of IEEE 118-bus system. The 24-hour load profile for each bus is derived by scaling the system’s rated load in the PSSE sav file according to the California Independent System Operator’s Day-ahead load forecast for May 1, 2024. This simulator performs several critical functions: (1) Calculating time-series power flow every 4 seconds; (2) Updating and dispatching AGC signals every minute; (3) Conducting N-1 contingency analysis every 5 minutes. Additionally, the simulator can trip lines and subsequently update and dispatch AGC signals, running power flow analysis after each tripping event.

Huang, Jianqiao [Idaho National Laboratory (INL), ↗

Unified Creep Plasticity Damage (UCPD) Model for Rigid Polyurethane Foams

Numerous experiments were performed to characterize the mechanical response of several different rigid polyurethane foams (FR3712, PMDI10, PMDI20, and TufFoam35) to large deformation. In these experiments, the effects of load path, loading rate, and temperature were investigated. Results from these experiments indicated that rigid polyurethane foams exhibit significant volumetric and deviatoric plasticity when they are compressed. Rigid polyurethane foams were also found to be very strain-rate and temperature dependent. These foams are also rather brittle and crack when loaded to small strains in tension or to larger strains in compression. Thus, a new Unified Creep Plasticity Damage (UCPD) model was developed and implemented into SIERRA with the name Foam Damage to describe the mechanical response of these foams to large deformation at a variety of temperatures and strain rates. This report includes a description of recent experiments and experimental findings. Next, development of a UCPD model for rigid, polyurethane foams is described. Selection of material parameters for a variety of rigid polyurethane foams is then discussed and finite element simulations with the new UCPD model are compared with experimental results to show behavior that can be captured with this model.

36 MATERIALS SCIENCE↗

Foot Forces during Treadmill Exercise on the International Space Station

Exercise has been the primary countermeasure to combat musculoskeletal changes during the approximately 6 month missions to the International Space Station (ISS). However, these countermeasures have not been successful in preventing loss of bone mineral density in the spine and hip of astronauts. We examined lower extremity loading during typical bouts of on-orbit exercise performed by 4 ISS crew members on the ISS treadmill (TVIS) and during locomotor activities on earth (1g). In-shoe forces were monitored at 128Hz using force-measuring insoles placed inside the shoes of the exercising crewmember, stored temporarily on Flash cards, and down-linked via satellite for analysis. Custom software extracted peak forces from up to 30 minutes of locomotor activity. All on-orbit loading conditions for walking and running resulted in peak forces and impact loading rates that were significantly less than those measured in 1g. Typical single leg loads on-orbit in walking and running were 0.860 plus or minus 0.04 body weights (BW) and 1.339 plus or minus 0.07 BW compared to 1.2 plus or minus 0.036 BW and 2.36 plus or minus 0.07 BW in 1g BW respectively. These results indicate that typical exercise on the ISS treadmill does not generate 1g-like loading conditions. This may be partly responsible for the loss of bone mineral density that has been observed in these and other crew members. Since on-orbit treadmill exercise requires a restraining load to return the crew member to the treadmill surface, more studies are required to enable comfortable full body weight loading to be applied.

Cavanagh, Peter R.↗

Study of a High Voltage Ion Engine Power Supply

A complete laboratory breadboard version of a ion engine power converter was built and tested. This prototype operated on a line voltage of 80-120 Vdc, and provided output ratings of 1100 V at 1.8 kW, and 250 V at 20 mA. The high-voltage (HV) output voltage rating was revised from the original value of 1350 V at the beginning of the project. The LV output was designed to hold up during a 1-A surge current lasting up to 1 second. The prototype power converter included a internal housekeeping power supply which also operated from the line input. The power consumed in housekeeping was included in the overall energy budget presented for the ion engine converter. HV and LV output voltage setpoints were commanded through potentiometers. The HV converter itself reached its highest power efficiency of slightly over 93% at low line and maximum output. This would dip below 90% at high line. The no-load (rated output voltages, zero load current) power consumption of the entire system was less than 13 W. A careful loss breakdown shows that converter losses are predominately Metal-Oxide-Semiconductor Field Effect Transistor (MOSFET) conduction losses and HV rectifier snubbing losses, with the rectifier snubbing losses becoming predominant at high line. This suggests that further improvements in power efficiency could best be obtained by either developing a rectifier that was adequately protected against voltage overshoot with less snubbing, or by developing a pre-regulator to reduced the range of line voltage on the converter. The transient testing showed the converter to be fully protected against load faults, including a direct short-circuit from the HV output to the LV output terminals. Two currents sensors were used: one to directly detect any core ratcheting on the output transformer and re-initiate a soft start, and the other to directly detect a load fault and quickly shut down the converter for load protection. The finished converter has been extensively fault tested without failure. The finished converter has been packaged suitable for use as a laboratory prototype for further testing. The finished converter is readily transportable. An article on design issues for high voltage converters for ion engines is included as an attachement.

Stuart, Thomas A.↗

The effect of temperature and microstructure on dynamic deformation of iron, tantalum, and titanium

Laser-driven shock loading was performed on thin samples of iron, tantalum, and titanium at strain-rates up to 10 7 s –1 , and over a range of temperatures extending from 120 through 800 K, to investigate the influence of temperature on the early stages of yielding and plastic flow in materials of distinct crystal structure and initial defect density. The onset of yielding was identified using time-resolved velocimetry of the target rear surface to reveal the peak elastic state in the precursor wave front. Measurements on as-received iron reveal a trend of decreasing peak elastic stress (σE) with increasing temperature and electron microscopy of the recovered material revealed evidence of mobile dislocations coalescing into subgrains. This is in contrast to the results for the annealed iron where theσEremains constant with increasing temperature and recovered samples showed indications of deformation twinning. For tantalum, the yield strength remains constant for the most part, but has a jump in yield strength at 815 K, indicative of a possible twinning to slip transition with increasing temperature. For titanium, the yield strength was generally constant with temperature. Here, these results provide insight into studying deformation mechanisms, such as slip and twinning, in high rate loading of materials.

36 MATERIALS SCIENCE↗

Modified formulation of a rate-dependent damage model for ductile materials

A modification to the rate-dependent damage and failure model developed by Addessio and Johnson [J. Appl. Phys. 74, 1640 (1993)] for ductile materials under high-rate loading is presented. In the current formulation the equilibrium stress, which is used to calculate the plastic strain rate and damage in the material, is defined as the orthogonal projection of the final stress onto an equilibrium yield surface, instead of being a projection of the trial stress onto the yield surface as is done in the original formulation. The modification makes the current formulation fully consistent with the viscoplasticity theory. An implicit algorithm is also presented for the modified model and numerical results of copper under uniaxial strain loading are given to show the features of the model and the algorithm. Comparisons with the results of the original formulation are also presented.

36 MATERIALS SCIENCE↗

Dynamic Tensile Characterization of Thin-Sheet Brittle Metallic Materials

Refractory metals are favorable materials in applications where high strength and ductility are needed at elevated temperatures. In some cases, operating temperatures may be near the melting point of the material. However, as temperature drops, refractory metals typically undergo a significant mechanical response change - ductile-to-brittle transition. These materials may be subjected to high strain rate loading at an ambient temperature state, such as an impact or crash. Knowledge of the high rate material properties are essential for design as well as simulation of impact events. The high rate stress-strain behavior of brittle metallic materials at ambient temperature is rarely studied because of experimental challenges, particularly when failure is involved. Failure typically occurs within the non-gage section of the material, which invalidates any collected stress-strain information. Here, a method to determine a specimen geometry which will produce failures in the gage section is presented. Pure tungsten in thin-sheet form was used as a trial material to select a specimen geometry for high rate Kolsky tension bar experiments. A finite element simulation was conducted to derive a strain correction for more accurate results. The room temperature stress-strain behavior of pure tungsten at a strain rate of 24 s –1 is presented. The outcome of this experimental technique can be applied to other brittle materials for dynamic tensile characterization.

36 MATERIALS SCIENCE↗

Controlling Strain Bursts and Avalanches at the Nano- to Micrometer Scale

We demonstrate, through three-dimensional discrete dislocation dynamics simulations, that the complex dynamical response of nano- and microcrystals to external constraints can be tuned. Under load rate control, strain bursts are shown to exhibit scale-free avalanche statistics, similar to critical phenomena in many physical systems. For the other extreme of displacement rate control, strain burst response transitions to quasiperiodic oscillations, similar to stick-slip earthquakes. External load mode control is shown to enable a qualitative transition in the complex collective dynamics of dislocations from self-organized criticality to quasiperiodic oscillations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Endpoint Use Efficiency Comparison for AC and DC Power Distribution in Commercial Buildings

Advances in power electronics and their use in Miscellaneous Electric Loads (MELs) in buildings have resulted in increased interest in using low-voltage direct current (DC) power distribution as a replacement for the standard alternating current (AC) power distribution in buildings. Both systems require an endpoint converter to convert the distribution system voltage to the MELs voltage requirements. This study focused on the efficiency of these endpoint converters by testing pairs of AC/DC and DC/DC power converters powering the same load profile. In contrast to prior studies, which estimated losses based on data sheet efficiency and rated loads, in this study, we used part load data derived from real-world time-series load measurements of MELs and experimentally characterized efficiency curves for all converters. The measurements performed for this study showed no systematic efficiency advantage for commercially available DC/DC endpoint converters relative to comparable, commercially available AC/DC endpoint converters. For the eight appliances analyzed with the pair of converters tested, in 50%, the weighted energy efficiency of the DC/DC converter was higher, while, for the other 50%, the AC/DC converter was. Additionally, the measurements indicated that the common assumption of using either data sheet efficiency values or efficiency at full load may result in substantial mis-estimates of the system efficiency.

AC/DC converters↗

Optimization of conical hydrostatic bearing for minimum friction.

Equations for the flow rate, load capacity, and friction torque for a conical hydrostatic bearing were developed. These equations were solved by a digital computer program to determine bearing configurations for minimum friction torque. Design curves are presented that show optimal bearing dimensions for minimum friction torque as a function of dimensionless flow rate for a range of dimensionless load capacity. Results are shown for both laminar and turbulent flow conditions. The results indicate that hydrostatic pocket friction is a significant portion of the total friction torque. However, the bearing dimensions for a minimum friction design are affected very little by inclusion of pocket friction in the analysis. For laminar flow the values of the outer-land radius ratio X3 and outer bearing radius ratio X4 did not change significantly with increasing friction factor. For turbulent flow, the outer bearing radius ratio X4 did not change with increasing friction factor; therefore the value determined for X4 in the laminar flow case is valid for all turbulent flows.

Nypan, L. J.↗

The 30-cm ion thruster power processor

A power processor unit for powering and controlling the 30 cm Mercury Electron-Bombardment Ion Thruster was designed, fabricated, and tested. The unit uses a unique and highly efficient transistor bridge inverter power stage in its implementation. The system operated from a 200 to 400 V dc input power bus, provides 12 independently controllable and closely regulated dc power outputs, and has an overall power conditioning capacity of 3.5 kW. Protective circuitry was incorporated as an integral part of the design to assure failure-free operation during transient and steady-state load faults. The implemented unit demonstrated an electrical efficiency between 91.5 and 91.9 at its nominal rated load over the 200 to 400 V dc input bus range.

Herron, B. G.↗