Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIFE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Experimental study of the {beta}-delayed neutron decay of {sup 21}N

The first spectroscopic study for the {beta} decay of {sup 21}N is carried out based on {beta}-n, {beta}-{gamma}, and {beta}-n-{gamma} coincidence measurements. The neutron-rich {sup 21}N nuclei are produced by the fragmentation of the E/A=68.8 MeV {sup 26}Mg primary beam on a thick {sup 9}Be target and are implanted into a thin plastic scintillator that also plays the role of {beta} detector. The time of flight of the emitted neutrons following the {beta} decay are measured by the surrounding neutron sphere and neutron wall arrays. In addition, four clover germanium detectors are used to detect the {beta}-delayed {gamma} rays. Thirteen new {beta}-delayed neutron groups are observed with a total branching ratio of 90.5{+-}4.2%. The half-life for the {beta} decay of {sup 21}N is determined to be 82.9{+-}7.5 ms. The level scheme of {sup 21}O is deduced up to about 9 MeV excitation energy. The experimental results for the {beta} decay of {sup 21}N are compared to the shell-model calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prompt and delayed spectroscopy of {sup 199}At

The neutron-deficient nucleus {sup 199}At has been studied through {gamma}-ray and electron spectroscopy, using the recoil-decay tagging technique. Two experiments were conducted, using a gas-filled recoil separator with a focal-plane spectrometer alone and together with a germanium-detector array at the target position. The resulting level scheme for {sup 199}At includes a new isomer with a half-life of 0.80(5) {mu}s and a spin and parity of (29/2{sup +}). The 13/2{sup +} isomer, which de-excites via an M2 transition to the 9/2{sup -} ground state, was measured to have a half-life of 70(20) ns. Our earlier version of the level scheme for {sup 197}At has been updated as well.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Report on the Depth Requirements for a Massive Detector at Homestake

This report provides the technical justification for locating a large detector underground in a US based Deep Underground Science and Engineering Laboratory. A large detector with a fiducial mass greater than 100 kTon will most likely be a multipurpose facility. The main physics justification for such a device is detection of accelerator generated neutrinos, nucleon decay, and natural sources of neutrinos such as solar, atmospheric and supernova neutrinos. The requirement on the depth of this detector will be guided by the rate of signals from these sources and the rate of backgrounds from cosmic rays over a very wide range of energies (from solar neutrino energies of 5 MeV to high energies in the range of tens of GeV). For the present report, we have examined the depth requirement for a large water Cherenkov detector and a liquid argon time projection chamber. There has been extensive previous experience with underground water Cherenkov detectors such as IMB, Kamioka, and most recently, Super-Kamiokande which has a fiducial mass of 22 kTon and a total mass of 50 kTon at a depth of 2700 meters-water-equivalent. Projections for signal and background capability for a larger and deeper (or shallower) detectors of this type can be scaled from these previous detectors. The liquid argon time projection chamber has the advantage of being a very fine-grained tracking detector, which provides enhanced capability for background rejection. In the current work we have taken the approach that the depth should be sufficient to suppress the cosmogenic background below predicted signal rates for either of the above two technologies. Nevertheless, it is also clear that the underground facility that we are examining must have a long life and will most likely be used either for future novel uses of the currently planned detectors or new technologies. Therefore the depth requirement also needs to be made on the basis of sound judgment regarding possible future use. In particular, the depth should be sufficient for any possible future use of these cavities or the level which will be developed for these large structures. Along with these physics justifications there are practical issues regarding the existing infrastructure at Homestake and also the stress characteristics of the Homestake rock formations. In this report we will examine the various depth choices at Homestake from the point of view of the particle and nuclear physics signatures of interest. We also have sufficient information about the existing infrastructure and the rock characteristics to narrow the choice of levels for the development of large cavities with long lifetimes. We make general remarks on desirable ground conditions for such large cavities and then make recommendations on how to start examining these levels to make a final choice. In the appendix we have outlined the initial requirements for the detectors. These requirements will undergo refinement during the course of the design. Finally, we strongly recommend that the geotechnical studies be commenced at the 4850 ft level, which we find to be the most suitable, in a timely manner.

43 PARTICLE ACCELERATORS↗

First Decay Spectroscopy Experiment at RIBF

A first RIBF experiment for decay spectroscopy was performed. Neutron-rich nuclei with mass number A {approx} 110 were produced using in-flight fission of {sup 238}U. A new beta-counting system consisting of nine layers of double-sided-silicon-strip detector (DSSSD) was employed to detect beta-rays from the neutron-rich nuclei stopped in the beta-counting system. The {beta}-decay curves of neutron-rich nuclei were successfully reconstructed. As a complementary device, a super-segmented scintillation detector (CAITEN) has been prepared for future decay experiment. Its fast counting capability dedicated for half-life measurement was confirmed using radioactive beam produced by the fragmentation of Ca-beam.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Differential Phase Contrast with a Segmented Detector in a Scanning X-ray Microprobe

Scanning X-ray microprobes are unique tools for the nanoscale investigation of specimens from the life, environmental, materials and other fields of sciences. Typically they utilize absorption and fluorescence as contrast mechanisms. Phase contrast is a complementary technique that can provide strong contrast with reduced radiation dose for weakly absorbing structures in the multi-keV range. In this paper the development of a segmented charge-integrating silicon detector which provides simultaneous absorption and differential phase contrast is reported. The detector can be used together with a fluorescence detector for the simultaneous acquisition of transmission and fluorescence data. It can be used over a wide range of photon energies, photon rates and exposure times at third-generation synchrotron radiation sources, and is currently operating at two beamlines at the Advanced Photon Source. Images obtained at around 2 keV and 10 keV demonstrate the superiority of phase contrast over absorption for specimens composed of light elements.

43 PARTICLE ACCELERATORS↗

Neutron and X-ray Detectors

The Basic Energy Sciences (BES) X-ray and neutron user facilities attract more than 12,000 researchers each year to perform cutting-edge science at these state-of-the-art sources. While impressive breakthroughs in X-ray and neutron sources give us the powerful illumination needed to peer into the nano- to mesoscale world, a stumbling block continues to be the distinct lag in detector development, which is slowing progress toward data collection and analysis. Urgently needed detector improvements would reveal chemical composition and bonding in 3-D and in real time, allow researchers to watch “movies” of essential life processes as they happen, and make much more efficient use of every X-ray and neutron produced by the source The immense scientific potential that will come from better detectors has triggered worldwide activity in this area. Europe in particular has made impressive strides, outpacing the United States on several fronts. Maintaining a vital U.S. leadership in this key research endeavor will require targeted investments in detector R&D and infrastructure. To clarify the gap between detector development and source advances, and to identify opportunities to maximize the scientific impact of BES user facilities, a workshop on Neutron and X-ray Detectors was held August 1-3, 2012, in Gaithersburg, Maryland. Participants from universities, national laboratories, and commercial organizations from the United States and around the globe participated in plenary sessions, breakout groups, and joint open-discussion summary sessions. Sources have become immensely more powerful and are now brighter (more particles focused onto the sample per second) and more precise (higher spatial, spectral, and temporal resolution). To fully utilize these source advances, detectors must become faster, more efficient, and more discriminating. In supporting the mission of today’s cutting-edge neutron and X-ray sources, the workshop identified six detector research challenges (and two computing hurdles that result from the corresponding increase in data volume) for the detector community to overcome in order to realize the full potential of BES neutron and X-ray facilities. Resolving these detector impediments will improve scientific productivity both by enabling new types of experiments, which will expand the scientific breadth at the X-ray and neutron facilities, and by potentially reducing the beam time required for a given experiment. These research priorities are summarized in the table below. Note that multiple, simultaneous detector improvements are often required to take full advantage of brighter sources. High-efficiency hard X-ray sensors: The fraction of incident particles that are actually detected defines detector efficiency. Silicon, the most common direct-detection X-ray sensor material, is (for typical sensor thicknesses) 100% efficient at 8 keV, 25%efficient at 20 keV, and only 3% efficient at 50 keV. Other materials are needed for hard X-rays. Replacement for 3He for neutron detectors: 3He has long been the neutron detection medium of choice because of its high cross section over a wide neutron energy range for the reaction 3He + n —> 3H + 1H + 0.764 MeV. 3He stockpiles are rapidly dwindling, and what is available can be had only at prohibitively high prices. Doped scintillators hold promise as ways to capture neutrons and convert them into light, although work is needed on brighter, more efficient scintillator solutions. Neutron detectors also require advances in speed and resolution. Fast-framing X-ray detectors: Today’s brighter X-ray sources make time-resolved studies possible. For example, hybrid X-ray pixel detectors, initially developed for particle physics, are becoming fairly mature X-ray detectors, with considerable development in Europe. To truly enable time-resolved studies, higher frame rates and dynamic range are required, and smaller pixel sizes are desirable. High-speed spectroscopic X-ray detectors: Improvements in the readout speed and energy resolution of X-ray detectors are essential to enable chemically sensitive microscopies. Advances would make it possible to take images with simultaneous spatial and chemical information. Very high-energy-resolution X-ray detectors: The energy resolution of semiconductor detectors, while suitable for a wide range of applications, is far less than what can be achieved with X-ray optics. A direct detector that could rival the energy resolution of optics could dramatically improve the efficiency of a multitude of experiments, as experiments are often repeated at a number of different energies. Very high-energy-resolution detectors could make these experiments parallel, rather than serial. Low-background, high-spatial-resolution neutron detectors: Low-background detectors would significantly improve experiments that probe excitations (phonons, spin excitations, rotation, and diffusion in polymers and molecular substances, etc.) in condensed matter. Improved spatial resolution would greatly benefit radiography, tomography, phase-contrast imaging, and holography. Improved acquisition and visualization tools: In the past, with the limited variety of slow detectors, it was straightforward to visualize data as it was being acquired (and adjust experimental conditions accordingly) to create a compact data set that the user could easily transport. As detector complexity and data rates explode, this becomes much more challenging. Three goals were identified as important for coping with the growing data volume from high-speed detectors: Facilitate better algorithm development. In particular, algorithms that can minimize the quantity of data stored. Improve community-driven mechanisms to reduce data protocols and enhance quantitative, interactive visualization tools. Develop and distribute community-developed, detector-specific simulation tools. Aim for parallelization to take advantage of high-performance analysis platforms. Improved analysis work flows: Standardize the format of metadata that accompanies detector data and describes the experimental setup and conditions. Develop a standardized user interface and software framework for analysis and data management. The diversity of detector improvements required is necessarily as broad as the range of scientific experimentation at BES facilities. This workshop identified a variety of avenues by which detector R&D can enable enhanced science at BES facilities. The Research Directions listed above will be addressed by focused R&D and detector engineering, both of which require specialized infrastructure and skills. While U.S. leadership in neutron and X-ray detectors lags behind other countries in several areas, significant talent exists across the complex. A forum of technical experts, facilities management, and BES could be a venue to provide further definition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

End of Life Decisions for Sealed Radioactive Sources

Sealed radioactive sources are encountered in a wide variety of settings – from household smoke detectors and instrument check sources, through fixed industrial gauges, industrial radiography and well logging sources, to irradiators and medical teletherapy devices. In general, the higher the level of activity in the sealed source, the stricter the regulatory control that is applied to its use, control and ultimate disposition. Lower levels of attention and oversight can and do lead to sources ending up in the wrong place – as orphan sources in uncontrolled storage, disposed in a sanitary landfill, melted down in metal recycling operations and incorporated into consumer products, or handled by an unsuspecting member of the public. There are a range of issues that contribute to the problem of improper disposal of sealed sources, and, in particular, to disused source disposal. General licensed sources and devices are particularly at risk of being disposed incorrectly. Higher activity general licensed sources, although required to be registered with the Nuclear Regulatory Commission (NRC) or Agreement State, receive limited regulatory oversight and are not tracked on a national scale. Users frequently do not consider the full life-cycle costs when procuring sources or devices and discover that they cannot afford to package, transport and dispose of their sources properly. The NRC requirements for decommissioning funding plans and financial assurance are not adequate to cover sealed source transport and disposal costs fully. While there are regulatory limits for storage of disused sources, enforcement is limited and there is no financial incentive for owners to dispose of the sources. In some cases, the lack of availability of approved Department of Transportation (DOT) Type B shipping casks also presents a barrier to sealed source disposal. The report of the Disused Sources Working Group does an excellent job of framing these issues. This article reviews both the issues and the report’s recommendations, which are designed to improve sealed source control and encourage proper disposal of disused sources.

disused source↗

Near-yrast, medium-spin, excited states of {sup 91}Rb, {sup 93}Rb, and {sup 95}Rb

The medium-spin structure of the nuclei {sup 93}Rb and {sup 95}Rb is studied following the neutron-induced fission of {sup 235}U at the PF1B neutron guide, using the FIFI spectrometer, and at the Lohengrin mass spectrometer of the Institut Laue-Langevin Grenoble. These nuclei, plus {sup 91}Rb, are also studied following the spontaneous fission of {sup 248}Cm and {sup 252}Cf sources, using the EUROGAM-II and Gammasphere detector arrays, respectively. A high-spin isomeric state, with a half-life of 111(11) ns, is found in {sup 93}Rb at an excitation energy of 4422.4 keV, which most likely corresponds to the fully aligned [{pi}(g{sub 9/2}) x {nu}(g{sub 7/2}h{sub 11/2})]{sub 27/2}{sup -} configuration. An analogous configuration is proposed for the 5297.9-keV level observed in {sup 91}Rb. A new E3 decay branch of the 1133.9-keV isomer in {sup 91}Rb is found, for which the rather low transition rate of B(E3)=3.8(10) W.u. is determined. The energy of the isomeric state of {sup 95}Rb is now proposed to be at 810.6 keV, with a spin of (9/2{sup +}), and its half-life determined to be T{sub 1/2}=94(7) ns. A cascade of prompt transitions is observed on top of the 810.6-keV isomer in {sup 95}Rb. The near-yrast structures of {sup 91}Rb, {sup 93}Rb, and {sup 95}Rb are compared to the results of shell-model calculations, which support the proposed 27/2{sup -} interpretation of states in {sup 91}Rb and {sup 93}Rb. An analogous 27/2{sup -} state is expected to occur in {sup 95}Rb, as a long-lived isomer at 3.24 MeV. No such isomeric decay could be observed in a measurement using the Lohengrin spectrometer, which shows that, if it exists, its population, following the fission of {sup 235}U, is at least four times lower than that of the analogous 27/2{sup -} isomer in {sup 97}Y.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Wavelength Shifting Plate on the LEGEND Experiment

Majorana-type neutrinos lead to a neutrinoless double beta decay with the emission of only two electrons. (Lepton Number Violation). LEGEND experiment is proposed to search for this transition from ⁷⁶Ge to ⁷⁶Se. The goal is to reach the half-life sensitivity of about 10²⁸ years in a 5 kton٠year exposure of a detector with 1 ton of isotopic ⁷⁶Ge mass.

Bae, Wonseok↗

Spacelab 2 - A preview

The Spacelab 2 mission, which is scheduled for Space Shuttle Challenger launch in July of 1985, will carry four telescopes for solar study, a dual X-ray telescope for observation of galaxy clusters, and a helium-cooled IR telescope for studies of interstellar clouds and other extended sources. The largest cosmic ray detector carried to space thus far will also be part of the payload. Life science experiment packages will examine the vitamin D chemistry of human blood under zero-G conditions, and the manner in which pine tree seedlings sense gravity and respond to it. Spacelab 2 will carry a crew of seven, including three mission specialists and two payload specialists.

Henize, K. G.↗

Charcoal/Nitrogen Adsorption Cryocooler

Refrigerator with no wear-related moving parts produces 0.5 W of cooling at 118 K. When fully developed, refrigerator needs no electrical power, and life expectancy of more than 10 yr, operates unattended to cool sensitive infrared detectors for long periods. Only moving parts in adsorption cryocooler are check valves. As charcoal is cooled in canister, gas pressure drops, allowing inlet check valve to open and admit more nitrogen. When canister is heated, pressure rises, closing inlet valve and eventually opening outlet valve.

Bard, Steven↗

Low power, lightweight vapor sensing using arrays of conducting polymer composite chemically-sensitive resistors

Arrays of broadly responsive vapor detectors can be used to detect, identify, and quantify vapors and vapor mixtures. One implementation of this strategy involves the use of arrays of chemically-sensitive resistors made from conducting polymer composites. Sorption of an analyte into the polymer composite detector leads to swelling of the film material. The swelling is in turn transduced into a change in electrical resistance because the detector films consist of polymers filled with conducting particles such as carbon black. The differential sorption, and thus differential swelling, of an analyte into each polymer composite in the array produces a unique pattern for each different analyte of interest, Pattern recognition algorithms are then used to analyze the multivariate data arising from the responses of such a detector array. Chiral detector films can provide differential detection of the presence of certain chiral organic vapor analytes. Aspects of the spaceflight qualification and deployment of such a detector array, along with its performance for certain analytes of interest in manned life support applications, are reviewed and summarized in this article.

NASA Discipline Life Sciences Technologies↗

Investigation of Double Beta Decay of 100Mo to Excited States of 100Ru

Double beta decay of 100Mo to the excited states of daughter nuclei has been studied using a 600 cm3 low-background HPGe detector and an external source consisting of 2588 g of 97.5% enriched metallic 100Mo, which was formerly inside the NEMO-3 detector and used for the NEMO-3 measurements of 100Mo. The half-life for the two-neutrino double beta decay of 100Mo to the excited View the MathML source state in 100Ru is measured to be T1/2=[7.5±0.6(stat)±0.6(syst)]·1020 yr. For other (0?+2?) transitions to the View the MathML source, View the MathML source, View the MathML source, View the MathML source and View the MathML source levels in 100Ru, limits are obtained at the level of ~(0.25–1.1)·1022 yr.

100Mo↗

SU-E-T-231: Measurements of Gold Nanoparticle-Mediated Proton Dose Enhancement Due to Particle-Induced X-Ray Emission and Activation Products Using Radiochromic Films and CdTe Detector

Purpose: There have been several reports of enhanced cell-killing and tumor regression when tumor cells and mouse tumors were loaded with gold nanoparticles (GNPs) prior to proton irradiation. While particle-induced xray emission (PIXE), Auger electrons, secondary electrons, free radicals, and biological effects have been suggested as potential mechanisms responsible for the observed GNP-mediated dose enhancement/radiosensitization, there is a lack of quantitative analysis regarding the contribution from each mechanism. Here, we report our experimental effort to quantify some of these effects. Methods: 5-cm-long cylindrical plastic vials were filled with 1.8 mL of either water or water mixed with cylindrical GNPs at the same gold concentration (0.3 mg Au/g) as used in previous animal studies. A piece of EBT2 radiochromic film (30-µm active-layer sandwiched between 80/175-µm outer-layers) was inserted along the long axis of each vial and used to measure dose enhancement due to PIXE from GNPs. Vials were placed at center-of-modulation (COM) and 3-cm up-/down-stream from COM and irradiated with 5 different doses (2–10 Gy) using 10-cm-SOBP 160-MeV protons. After irradiation, films were cleaned and read to determine the delivered dose. A vial containing spherical GNPs (20 mg Au/g) was also irradiated, and gamma-rays from activation products were measured using a cadmium-telluride (CdTe) detector. Results: Film measurements showed no significant dose enhancement beyond the experimental uncertainty (∼2%). There was a detectable activation product from GNPs, but it appeared to contribute to dose enhancement minimally (<0.01%). Conclusion: Considering the composition of EBT2 film, it can be inferred that gold characteristic x-rays from PIXE and their secondary electrons make insignificant contribution to dose enhancement. The current investigation also suggests negligible dose enhancement due to activation products. Thus, previously-reported GNP-mediated proton dose enhancement/radiosensitization needs to be attributed to one or more of the other mechanisms listed earlier. Supported in part by NIH/NCI grant R01CA155446;This investigation was supported in part by NIH/NCI grant R01CA155446.

60 APPLIED LIFE SCIENCES↗

Distribution of polychlorinated biphenyls and organochlorine pesticides in human breast milk from various locations in Tunisia: Levels of contamination, influencing factors, and infant risk assessment

The concentrations of dichlorodiphenytrichloroethane and its metabolites (DDTs), hexachlorobenzene (HCB), hexachlorocyclohexane isomers (HCHs), dieldrin, and 20 polychlorinated biphenyls (PCBs) were determined in 237 human breast milk samples collected from 12 locations in Tunisia. Gas chromatography with electron capture detector (GC-ECD) was used to identify and quantify residue levels on a lipid basis of organochlorine compounds (OCs). The predominant OCs in human breast milk were PCBs, p,p'-DDE, p,p'-DDT, HCHs, and HCB. Concentrations of DDTs in human breast milk from rural areas were significantly higher than those from urban locations (p<0.05). With regard to PCBs, we observed the predominance of mid-chlorinated congeners due to the presence of PCBs with high K{sub ow} such as PCB 153, 138, and 180. Positive correlations were found between concentrations of OCs in human breast milk and age of mothers and number of parities, suggesting the influence of such factors on OC burdens in lactating mothers. The comparison of daily intakes of PCBs, DDTs, HCHs, and HCB to infants through human breast milk with guidelines proposed by WHO and Health Canada shows that some individuals accumulated OCs in breast milk close to or higher than these guidelines.

60 APPLIED LIFE SCIENCES↗

SuperNEMO Project Status

The SuperNEMO experiment aims to reach a sensitivity up to 10{sup 26} years on the half-life of neutrinoless double beta decay. The chosen way is to build a 'tracko-calo' detector with at least 100 kg of betabeta isotope. The current status of the main R and D tasks will be presented: enrichment and production of source foil, radiopurity control, tracker and calorimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Report on the Depth Requirements for a Massive Detector at Homestake

This report provides the technical justification for locating a large detector underground in a US based Deep Underground Science and Engineering Laboratory. A large detector with a fiducial mass greater than 100 kTon will most likely be a multipurpose facility. The main physics justification for such a device is detection of accelerator generated neutrinos, nucleon decay, and natural sources of neutrinos such as solar, atmospheric and supernova neutrinos. The requirement on the depth of this detector will be guided by the rate of signals from these sources and the rate of backgrounds from cosmic rays over a very wide range of energies (from solar neutrino energies of 5 MeV to high energies in the range of hundreds of GeV). For the present report, we have examined the depth requirement for a large water Cherenkov detector and a liquid argon time projection chamber. There has been extensive previous experience with underground water Cherenkov detectors such as IMB, Kamioka, and most recently, Super-Kamiokande which has a fiducial mass of 22 kTon and a total mass of 50 kTon at a depth of 2700 meters-water-equivalent in a mountain. Projections for signal and background capability for a larger and deeper(or shallower) detectors of this type can be scaled from these previous detectors. The liquid argon time projection chamber has the advantage of being a very fine-grained tracking detector, which should provide enhanced capability for background rejection. We have based background rejection on reasonable estimates of track and energy resolution, and in some cases scaled background rates from measurements in water. In the current work we have taken the approach that the depth should be sufficient to suppress the cosmogenic background below predicted signal rates for either of the above two technologies. Nevertheless, it is also clear that the underground facility that we are examining must have a long life and will most likely be used either for future novel uses of the currently planned detectors or new technologies. Therefore the depth requirement also needs to be made on the basis of sound judgment regarding possible future use. In particular, the depth should be sufficient for any possible future use of these cavities or the level which will be developed for these large structures.Along with these physics justifications there are practical issues regarding the existing infrastructure at Homestake and also the stress characteristics of the Homestake rock formations. In this report we will examine the various depth choices at Homestake from the point of view of the particle and nuclear physics signatures of interest. We also have sufficient information about the existing infrastructure and the rock characteristics to narrow the choice of levels for the development of large cavities with long lifetimes. We make general remarks on desirable ground conditions for such large cavities and then make recommendations on how to start examining these levels to make a final choice. In the appendix we have outlined the initial requirements for the detectors. These requirements will undergo refinement during the course of the design. Finally, we strongly recommend that the geotechnical studies be commenced at the 4850 ft level, which we find to be the most suitable, in a timely manner.

43 PARTICLE ACCELERATORS↗

Utilization of Unsupervised Anomalies Detector as a Tool for Managing the TDRS Constellation at GSFC

NASA’s Goddard Space Flight Center (GSFC) operates a constellation of ten geosynchronous Tracking and Data Relay Satellites (TDRS). The mission of the TDRS constellation is to provide relay communications from low-earth orbiting spacecraft to the primary ground station at the White Sands Complex in Las Cruces, New Mexico. Major customers include the International Space Station and Hubble Space Telescope. The NASA Space Network project office at GSFC manages the constellation of spacecraft. The constellation is over 30 years old, and a wide range of technologies and manufacturing techniques are represented on-orbit. Since 1983, the TDRS constellation has recorded thousands of gigabytes of telemetry data. Spacecraft telemetry data has changed throughout the three generations of TDRS spacecraft, however each spacecraft has the same basic functions with some generational enhancements. The constellation includes several spacecraft that have significantly outlived the manufacturer's projected lifetime. This has provided NASA with a significant benefit in terms of return on investment, however it places a burden on efficient management of the assets for maximum life without permitting a TDRS spacecraft to become stranded in its geosynchronous orbital slot. Consequently, the highest level of attention is paid to systems whose failure could strand a TDRS spacecraft in orbit. In this paper, we proposed two stages of analyzing spacecraft anomalies using data mining (DM) to enhance on-going predictions of spacecraft life, subsystem performance, and analysis of subsystem anomalies. The first stage conducts the unsupervised anomaly detector to detect potential anomalies in real-time telemetry data. The second stage introduced telemetry weight (TW) to each telemetry parameter to determine which parameter caused the strongest anomaly. We will present case studies of some of these analyses and how the data can impact decisions on the management of the constellation.

Ma, Kenneth Y.↗