Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LEAKAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Advanced Zonal Infiltration Measurement Method for Multifamily Buildings: A Novel Test Procedure to Determine Air Leakage Through External and Internal Surfaces

Measuring air infiltration through the external building envelope as well as between adjacent zones within a building is important since air leakage is related to increased energy use and poor indoor air quality (IAQ). State of the art methods can determine both leakages, however it can be both time consuming and labor intensive as it requires running both guarded and compartmentalization tests. This paper presents our work on developing a simplified testing procedure to determine power law flow equation leakage parameters of both external and internal boundaries of tested zones. The proposed Zonal Multipoint Pressure Test (ZMPT) method modulates airflow in the zone using a variable airflow measurement panel (mounted in either a window or the door), and solving the mass balance equations for the leakage parameters. ZMPT results were compared to conventional test results and found to correlate to within +/-7%.

Jayarathne, Tharanga↗

Leakage Rate Testing Considerations and Implementation of ANSI N 14.5-2014 Standard within EnergySolutions Type (B) cask fleet - 18629

In March 2016, Nuclear Regulatory Commission (NRC) staff issued Information Notice 2016-04: 'ANSI N14.5-2014 Revision and leakage rate testing considerations'. American National Standards Institute (ANSI) N14.5, 'American National Standard for Radioactive Materials-Leakage Tests on Packages for Shipment', applies to leakage rate testing of Low Level Radioactive Waste (LLRW) Type B packages operated under 10CFR71. In their information notice NRC is encouraging Type B cask license holders and licensees (cask users) to adapt a new version of ANSI N 14.5 standard. Typically, leakage rate testing for Type B packages (or casks) is performed at different stages of cask development (design and fabrication leak tests) and operations (periodic/maintenance and pre-shipment leak tests) with the purpose to reasonably assure that the packaging will contain radioactive material under both normal and hypothetical accident conditions of transport described in 10CFR71. The standard was updated to provide a modern, robust and standardized approach for performance of leak rate testing on Type B casks by the industry stakeholders. Although implementation of new version of the leak testing standard may not be problematic for a modern Type B package designs, it may be extremely challenging to apply its principles to the existing legacy Type B casks which were designed/fabricated more then 20-30 years ago based on older requirements. Majority of such casks are not 'leak test' friendly. Some of legacy Type B packages may not readily available to meet newer ANSI N 14.5 standard requirements and will require implementation of alternative compensatory measures in lieu of the standard's requirements. In addition, the new standard mandates implementation of additional requirements for leak rate testing performance and personnel qualifications during routine maintenance of Type B casks by owner and during operations of casks by users. The focus of the paper will be to discuss ANSI N 14.5-2014 requirements and provide specific examples on how these requirements will impact the current leak rate test practices. This will be illustrated based on several Type B cask models operated within EnergySolutions fleet (both newer and legacy cask designs). Finally, the paper will cover considerations of the cask closure design features that have to be considered by Type B cask designers in order to ensure robustness of leak testing during design, fabrication and, most importantly, operation of a package. This information shall benefit both owners and users of Type B casks with respect to improvement of the cask designs and Type B cask operational experience. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Method of detecting leakage from geologic formations used to sequester CO.sub.2

The invention provides methods for the measurement of carbon dioxide leakage from sequestration reservoirs. Tracer moieties are injected along with carbon dioxide into geological formations. Leakage is monitored by gas chromatographic analyses of absorbents. The invention also provides a process for the early leak detection of possible carbon dioxide leakage from sequestration reservoirs by measuring methane (CH.sub.4), ethane (C.sub.2H.sub.6), propane (C.sub.3H.sub.8), and/or radon (Rn) leakage rates from the reservoirs. The invention further provides a method for branding sequestered carbon dioxide using perfluorcarbon tracers (PFTs) to show ownership.

58 GEOSCIENCES↗

Technology Solutions Case Study: Air Leakage and Air Transfer Between Garage and Living Space, Waldorf, Maryland

In this project, Building Science Corporation worked with production homebuilder K. Hovnanian to evaluate air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multipoint fan pressurization tests and additional zone pressure diagnostic testing measured the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

air leakage↗

Physics-informed machine learning for fault-leakage reduced-order modeling

Geologic carbon storage (GCS) is a promising technology for mitigating CO 2 emissions. The overall success of GCS depends on safe operations that are informed by risk assessment and have proper mitigation plans in place. Performing quantitative probabilistic risk assessment for a GCS site using traditional reservoir simulators can be challenging due to the high computational costs. To overcome this challenge, the US Department of Energy’s National Risk Assessment Partnership (NRAP) project has developed an integrated assessment modeling approach that utilizes computationally efficient reduced-order models (ROM) for simulating various parts of a GCS storage site to quantify uncertainty. Here, in this study, we develop a reduced-order model for fault leakage risk assessment. We use a deep learning approach to build the reduced-order model. We perform a sensitivity analysis and find that the deep learning model yields high accuracy with a much smaller computational cost than full-physics simulation. We also evaluate the performance of the model in scenarios where simulations are not possible to run, providing analysis not previously performed in fault-leakage ROM analyses. Based on a sensitivity analysis of the model, we suggest a simplified conceptual model for fault leakage and site monitoring.

58 GEOSCIENCES↗

Creating an Advanced Sensor Network to calculate real-time, mass-weighted flue gas composition and air heater leakage of a coal-fired utility boiler under dynamic operating conditions

Utilization of renewable energy sources to minimize the environmental impact of energy production has changed the way utility boilers operate, requiring frequent load cycling between full load and partial loads as low as 30%. Dynamic operation of coal-fired utility boilers significantly reduces boiler efficiency when compared to steady state at full load. Data-driven plant optimization has shown success with coal-fired utility boilers under dynamic operating conditions. The purpose of this work was to create an Advanced Sensor Network (ASN) to provide more extensive real-time data to inform dynamic plant optimization of Net Unit Heat Rate (NUHR). The ASN consists of gas sampling grids in the convective pass of the boiler and downstream of the air heater. These sampling grids allow for quantification of spatial variation of flue gas within the boiler and calculation of mass-weighted composition of flue gas through the combination of composition, velocity, and temperature measurements. The comparison of O 2 between the inlet and outlet of the air heater is used to calculate air leakage in real time. Flue gas composition and air heater leakage are both important factors in boiler efficiency and NUHR. Further, the results of this work support the value of mass-weighted averages for determining flue gas composition accurately. The measurements from the ASN show increased composition stratification during dynamic operation, with an average standard deviation 38% higher than observed during steady-state operation. Air heater leakage was also observed to increase from 2.8% to 5.1% following a load change. Prior to the installation of the ASN, these data would not have been available for dynamic control. These real-time data will be leveraged to calculate and optimize for NUHR during dynamic operation in future work.

42 ENGINEERING↗

Improved leakage current and ferromagnetic properties in magnetic field annealed BiFeO{sub 3}-based ceramics

Single-phase Bi{sub 0.85}La{sub 0.15}FeO{sub 3} ceramics were synthesized under various magnetic fields (H{sub a}=0 T, 3 T, 5 T). Substantially reduced leakage current and hence modified ferroelectric (FE) properties were obtained with magnetic field annealing (MA). The largest magnetization and lowest leakage current with large FE polarization (P{sub r}{approx}33 {mu}C/cm{sup 2}) were found in the sample annealed with H{sub a}=3 T. Great changes were also observed in the Raman spectra. All the observed features originate mainly from the different FE domain wall structures induced by MA. These results demonstrate that MA is an effective way to tune the multiferroic and magnetoelectric properties in BiFeO{sub 3}-based materials. - Graphical abstract: Bright field TEM micrograph of the representative domain structures in the samples (a) BLF0, (b) BLF3 and (c) BLF5. Highlights: Black-Right-Pointing-Pointer Bi{sub 0.85}La{sub 0.15}FeO{sub 3} ceramics were synthesized under various magnetic fields. Black-Right-Pointing-Pointer Substantially reduced leakage current with improved ferroelectricity were obtained. Black-Right-Pointing-Pointer Enhanced magnetization with moderate annealing magnetic field.

36 MATERIALS SCIENCE↗

Tungsten erosion and divertor leakage from the DIII-D SAS-VW tungsten-coated divertor in experiments with neon gas seeding

Collector probes have been used to examine tungsten divertor leakage in a variety of scenarios with low-Z impurity seeding during operation with the new tungsten-coated SAS-VW divertor in DIII-D. Measurements of tungsten deposition on collector probes inserted into the far Scrape-off-Layer (SOL) are used to deduce how efficiently tungsten leaks out of the closed, V-shaped divertor after it is eroded from the target surfaces. Qualitative differences in the tungsten deposition patterns across the collector probes provide clear experimental evidence that the SOL conditions depend on the low-Z impurity seeding conditions. These measurements show that in scenarios where neon gas is injected into the plasma, the tungsten divertor leakage and SOL transport depend on the poloidal location from which the neon is injected. In particular, neon injection from the Inner Midplane and Outer Midplane appear to each result in higher divertor leakage by a factor of 2 to 3 compared to cases with neon injection from either the SOL Crown or from the SAS-VW divertor itself.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reduction of leakage currents with nanocrystals embedded in an amorphous matrix in metal-insulator-metal capacitor stacks

CaTiO{sub 3} layers with varying thicknesses in metal-insulator-metal capacitor stacks were deposited at 550 deg. C using radio-frequency magnetron sputtering. The combination of electrical and transmission electron microscopy measurements allows a correlation of k-value and leakage current to the degree of crystallinity. Experiments show that higher crystallinity and, therefore, higher k-values lead to increasing leakage currents and change of conduction mechanisms. However, leakage currents are significantly reduced when crystallites are embedded in an amorphous matrix. Selective growth of these crystallites is owed to cube-on-cube nucleation of CaTiO{sub 3} on {l_brace}011{r_brace} Pt.

36 MATERIALS SCIENCE↗

Investigation of band offsets and direct current leakage properties of nitrogen doped epitaxial Gd{sub 2}O{sub 3} thin films on Si

Dielectric properties of epitaxial Gd{sub 2}O{sub 3} thin films grown on Si have been found to improve significantly by incorporation of suitable dopants. However, in order to achieve optimum electrical properties from such doped oxides, it is important to understand the correlation between doping and the electronic structure of the material. In the present article, we report about the effect of nitrogen doping on the electronic structure and room temperature dc leakage properties of epitaxial Gd{sub 2}O{sub 3} thin films. Epitaxial Gd{sub 2}O{sub 3}:N thin films were grown on p-type Si (111) substrates by solid source molecular beam epitaxy technique using molecular N{sub 2}O as the nitridation agent. First investigations confirmed the presence of substitutional N in the Gd{sub 2}O{sub 3}:N layers. Incorporation of nitrogen did not affect the structural quality of the oxide layers. X ray photoelectron spectroscopy investigations revealed band gap narrowing in epitaxial Gd{sub 2}O{sub 3} due to nitrogen doping, which leads to reduction in the valence band offset of the Gd{sub 2}O{sub 3}:N layers with Si. DC leakage current measured at room temperature revealed that despite reduction in the band gap and valence band offsets due to N doping, the Gd{sub 2}O{sub 3}:N layers remain sufficiently insulating. A significant reduction of the leakage current densities in the Gd{sub 2}O{sub 3}:N layers with increasing nitrogen content suggests that doping of epitaxial Gd{sub 2}O{sub 3} thin films with nitrogen can be an effective route to eliminate the adverse effects of the oxygen vacancy induced defects in the oxide layers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The role of localized junction leakage in the temperature-dependent laser-beam-induced current spectra for HgCdTe infrared focal plane array photodiodes

We have performed the study on the dependence of laser beam induced current (LBIC) spectra on the temperature for the vacancy-doped molecular beam epitaxy grown Hg{sub 1−x}Cd{sub x}Te (x = 0.31) photodiodes by both experiment and numerical simulations. It is found that the measured LBIC signal has different distributions for different temperature extents. The LBIC profile tends to be more asymmetric with increasing temperature below 170 K. But the LBIC profile becomes more symmetric with increasing temperature above 170 K. Based on a localized leakage model, it is indicated that the localized junction leakage can lead to asymmetric LBIC signal, in good agreement with the experimental data. The reason is that the trap-assisted tunneling current is the dominant leakage current at the cryogenic temperature below 170 K while the diffusion current component becomes dominant above the temperature of 170 K. The results are helpful for us to better clarify the mechanism of the dependence of LBIC spectra on temperature for the applications of HgCdTe infrared photodiodes.

36 MATERIALS SCIENCE↗

Investigation of leakage current paths in n-GaN by conductive atomic force microscopy

We have investigated electrical characteristics of leakage current paths in n-GaN layer grown by metal-organic chemical vapor deposition with conductive-atomic force microscopy (C-AFM). The C-AFM mapping shows two kinds of leakage current paths existing in the n-GaN layer: open-core dislocation and pure screw dislocation. From the localized I-V curves measured by C-AFM, we confirmed that the open-core screw dislocation shows more significant leakage current. We explained these results in terms of a modified Schottky band model based on donor states formed by oxygen segregation at the (10−10) sidewall of the open-core screw dislocation.

36 MATERIALS SCIENCE↗

Extremely scaled high-k/In₀.₅₃Ga₀.₄₇As gate stacks with low leakage and low interface trap densities

Highly scaled gate dielectric stacks with low leakage and low interface trap densities are required for complementary metal-oxide-semiconductor technology with III-V semiconductor channels. Here, we show that a novel pre-deposition technique, consisting of alternating cycles of nitrogen plasma and tetrakis(dimethylamino)titanium, allows for HfO₂ and ZrO₂ gate stacks with extremely high accumulation capacitance densities of more than 5 μF/cm₂ at 1 MHz, low leakage current, low frequency dispersion, and low midgap interface trap densities (10¹²cm⁻²eV⁻¹range). Using x-ray photoelectron spectroscopy, we show that the interface contains TiO₂ and small quantities of In₂O₃, but no detectable Ga- or As-oxides, or As-As bonding. The results allow for insights into the microscopic mechanisms that control leakage and frequency dispersion in high-k/III-V gate stacks.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Physics of gate leakage current in N-polar InAlN/GaN heterojunction field effect transistors

A physics based model of the gate leakage current in N-polar InAlN/GaN heterojunction field effect transistors is demonstrated. The model is based on the space charge limited current flow dominated by the effects of deep traps in the InAlN surface layer. The model predicts accurately the gate-leakage measurement data of the N-polar InAlN/GaN device with InAlN cap layer. In the pinch-off state, the gate leakage current conduction through the surface of the device in the drain access region dominates the current flow through the two dimensional electron gas channel. One deep trap level and two levels of shallow traps are extracted by fitting the model results with measurement data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Asymmetric tunneling model of forward leakage current in GaN/InGaN light emitting diodes

Through investigating the temperature dependent current-voltage (T-I-V) properties of GaN based blue and green LEDs in this study, we propose an asymmetric tunneling model to understand the leakage current below turn-on voltage (V < 3.2 V): At the forward bias within 1.5 V ∼ 2.1 V (region 1), the leakage current is main attributed to electrons tunneling from the conduction band of n-type GaN layer to the valence band of p-type GaN layer via defect states in space-charge region (SCR); While, at the forward bias within 2 V ∼ 2.4 V (region 2), heavy holes tunneling gradually becomes dominant at low temperature (T < 200K) as long as they can overcome the energy barrier height. The tunneling barrier for heavy holes is estimated to be lower than that for electrons, indicating the heavy holes might only tunnel to the defect states. This asymmetric tunneling model shows a novel carrier transport process, which provides better understanding of the leakage characteristics and is vital for future device improvements.

36 MATERIALS SCIENCE↗

A physical model for the reverse leakage current in (In,Ga)N/GaN light-emitting diodes based on nanowires

We investigated the origin of the high reverse leakage current in light emitting diodes (LEDs) based on (In,Ga)N/GaN nanowire (NW) ensembles grown by molecular beam epitaxy on Si substrates. To this end, capacitance deep level transient spectroscopy (DLTS) and temperature-dependent current-voltage (I-V) measurements were performed on a fully processed NW-LED. The DLTS measurements reveal the presence of two distinct electron traps with high concentrations in the depletion region of the p-i-n junction. These band gap states are located at energies of 570 ± 20 and 840 ± 30 meV below the conduction band minimum. The physical origin of these deep level states is discussed. The temperature-dependent I-V characteristics, acquired between 83 and 403 K, show that different conduction mechanisms cause the observed leakage current. On the basis of all these results, we developed a quantitative physical model for charge transport in the reverse bias regime. By taking into account the mutual interaction of variable range hopping and electron emission from Coulombic trap states, with the latter being described by phonon-assisted tunnelling and the Poole-Frenkel effect, we can model the experimental I-V curves in the entire range of temperatures with a consistent set of parameters. Our model should be applicable to planar GaN-based LEDs as well. Furthermore, possible approaches to decrease the leakage current in NW-LEDs are proposed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Leakage current phenomena in Mn-doped Bi(Na,K)TiO{sub 3}-based ferroelectric thin films

Mn-doped 80(Bi{sub 0.5}Na{sub 0.5})TiO{sub 3}-20(Bi{sub 0.5}K{sub 0.5})TiO{sub 3} thin films were fabricated by chemical solution deposition on Pt/TiO{sub 2}/SiO{sub 2}/Si substrates. Steady state and time-dependent leakage current were investigated from room temperature to 180 °C. Undoped and low-doped films showed space-charge-limited current (SCLC) at high temperatures. The electric field marking the transition from Ohmic to trap-filling-limited current increased monotonically with Mn-doping. With 2 mol. % Mn, the current was Ohmic up to 430 kV/cm, even at 180 °C. Modeling of the SCLC showed that all films exhibited shallow trap levels and high trap concentrations. In the regime of steady state leakage, there were also observations of negative differential resistivity and positive temperature coefficient of resistivity near room temperature. Both of these phenomena were confined to relatively low temperatures (below ∼60 °C). Transient currents were observed in the time-dependent leakage data, which was measured out to several hundred seconds. In the undoped films, these were found to be a consequence of oxygen vacancy migration modulating the electronic conductivity. The mobility and thermal activation energy for oxygen vacancies was extracted as μ{sub ion} ≈ 1.7 × 10{sup −12} cm{sup 2} V{sup −1} s{sup −1} and E{sub A,ion} ≈ 0.92 eV, respectively. The transient current displayed different characteristics in the 1 mol. % Mn-doped films which were not readily explained by oxygen vacancy migration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison of the measured and calculated time profiles of the leakage current in the magnetically insulated transmission line of the angara-5-1 facility

One of the factors limiting the transmission of the electromagnetic pulse to the load in high-power electrophysical facilities is the current leakage in magnetically insulated transmission lines (MITLs). In this paper, the Angara-5-1 eight-module facility with an output power up to 6 TW is considered. The experimental and calculated time profiles of the leakage current for eight-module shots with a dynamic load (cylindrical arrays made of 40 tungsten wires) and single-module shots with a solid cylindrical metal load are compared. When interpreting the results, the contribution of vacuum electrons to the leakage current at the transition from the cylindrical to the conical section of the MITL is taken into account.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗