LCLS Injector Straight-Ahead Spectrometer

The spectrometer design was modified to allow the measurement of uncorrelated energy spread for the nominal lattice. One bunch from every 120 each second would be sent to the straight ahead spectrometer while the transverse cavity is on. The implementation of this 'stealing mode' will not be available for the LCLS commissioning and the early stage of operation. However, the spectrometer was redesigned to retain that option. The energy feedback relies independently on the beam position of the beam in the dispersive section of dogleg 1 (DL1). The main modification of the spectrometer design is the Pole face rotation of 7.5 degrees on both entrance and exit faces. The location and range of operation of the 3 quadrupoles remains unchanged relative to those of the earlier design.

43 PARTICLE ACCELERATORS↗

Triggering for Magnetic Field Measurements of the LCLS Undulators

A triggering system for magnetic field measurements of the LCLS undulators has been built with a National Instruments PXI-1002 and a Xylinx FPGA board. The system generates single triggers at specified positions, regardless of encoder sensor jitter about a linear scale.

43 PARTICLE ACCELERATORS↗

Tests of Coordinate Transfer from Magnetic to Mechanical Reference for LCLS Undulator Fiducialization

Fiducialization of the LCLS undulators will be based on magnetic measurements by Hall probe. Pointed magnets, proposed by I.Vasserman for quadrupole lens fiducialization will be used as an intermediate reference. A prototype of the pointed magnet fixture has been made and tested. In this note we will describe a procedure for measuring the position of the center of the Hall probe sensitive area with respect to the undulator fiducial marks. The pointed magnet calibration procedure, a two-point algorithm for locating the magnetic center of the fixture, and test results are presented.

43 PARTICLE ACCELERATORS↗

Location of Maximum Credible Beam Losses in LCLS Injector

The memo describes the maximum credible beam the LCLS injector can produce and lose at various locations along the beamline. The estimation procedure is based upon three previous reports [1, 2, 3]. While specific numbers have been updated to accurately reflect the present design parameters, the conclusions are very similar to those given in Ref 1. The source of the maximum credible beam results from the explosive electron emission from the photocathode if the drive laser intensity exceeds the threshold for plasma production. In this event, the gun's RF field can extract a large number of electrons from this plasma which are accelerated out of the gun and into the beamline. This electron emission persists until it has depleted the gun of all its energy. Hence the number of electrons emitted per pulse is limited by the amount of stored RF energy in the gun. It needs to be emphasized that this type of emission is highly undesirable, as it causes permanent damage to the cathode.

43 PARTICLE ACCELERATORS↗

A Design Report for the Optical Transition Radiation Imager for the LCLS Undulator

The Linac Coherent Light Source (LCLS), a free-electron x-ray laser, is under design and construction. Its high-intensity electron beam, 3400 A in peak current and 46 TW in peak power, is concentrated in a small area (37 micrometer in rms radius) inside its undulator. Ten optical transition radiation (OTR) imagers are planned between the undulator segments for characterizing the transverse profiles of the electron beam. In this note, we report on the optical and mechanical design of the OTR imager. Through a unique optical arrangement, using a near-normal-incidence screen and a multi-layer coated mirror, this imager will achieve a fine resolution (12 micrometer or better) over the entire field of view (8 mm x 5 mm), with a high efficiency for single-shot imaging. A digital camera will be used to read out the beam images in a programmable region (5 mm x 0.5 mm) at the full beam repetition rate (120 Hz), or over the entire field at a lower rate (10 Hz). Its built-in programmable amplifier will be used as an electronic intensity control.

43 PARTICLE ACCELERATORS↗

The Physics of the Gas Attenuator for the Linac Coherent Light Source (LCLS)

A systematic assessment of a variety of physics issues affecting the performance of the LCLS X-ray beam attenuator is presented. Detailed analysis of the gas flow in the gas attenuator and in the apertures is performed. A lot of attention is directed towards the gas ionization and heating by intense X-ray pulses. The role of these phenomena in possible deviations of the attenuation coefficient from its 'dialed in' value is evaluated and found small in most cases. Other sources of systematic and statistical errors are also discussed. The regimes where the errors may reach a few percent correspond to the lower X-ray energies (less than 2 keV) and highest beam intensities. Other effects discussed include chemical interaction of the gas with apertures, shock formation in the transonic flow in the apertures of the attenuator, generation of electromagnetic wakes in the gas, and head-to-tail variation of the attenuation caused by the ionization of gas or solid. Possible experimental tests of the consistency of the physics assumptions used in the concept of the gas attenuator are discussed. Interaction of X-rays with the solid attenuator (that will be used at higher X-ray energies, from 2.5 to 8 keV) is considered and thermo-mechanical effects caused by the beam heating are evaluated. Wave-front distortions induced by non-uniform heating of both the solid and the gas are found to be small. An overall conclusion drawn from the analysis presented is that the attenuator will be a reliable and highly versatile device, provided that some caution is exercised in its use for highest beam intensities at lowest X-ray energies.

43 PARTICLE ACCELERATORS↗

Data Acquisition in a High Harmonic Generation Lab and at LCLS

In this paper, we examine data acquisition in a high harmonic generation (HHG) lab and preliminary data analysis with the Cyclohexadiene Collaboration at the Linac Coherent Lightsource (LCLS) at SLAC National Accelerator Laboratory. HHG experiments have a large number of parameters that need to be monitored constantly. In particular, the pressure of the target is critical to HHG yield. However, this pressure can fluctuate wildly and without a tool to monitor it, it is difficult to analyze the correlation between HHG yield and the pressure. I used the Arduino microcontroller board and created a complementary MATLAB graphical user interface (GUI), thereby enhancing the ease with which users can acquire time-stamped parameter data. Using the Arduino, it is much easier to match the pressure to the corresponding HHG yield. Collecting data by using the Arduino and the GUI is flexible, user-friendly, and cost-effective. In the future, we hope to be able to control and monitor parts of the lab with the Arduino alone. While more parameter information is needed in the HHG lab, we needed to reduce the amount of data during the cyclohexadiene collaboration. This was achieved by sorting the data into bins and filtering out unnecessary details. This method was highly effective in that it minimized the amount of data without losing any valuable information. This effective preliminary data analysis technique will continue to be used to decrease the size of the collected data.

43 PARTICLE ACCELERATORS↗

Analysis on Achieving a Minimum Bunch Length in LCLS Bunch Compressor One

An ultra-short bunch is required by different applications in many aspects. In this paper, the condition to achieve a minimum bunch length at the Linac Coherent Light Source (LCLS) [1] bunch compressor one (BC1) is analyzed analytically and evaluated by simulation. The space charge, wake field and coherent synchrotron radiation (CSR) effects are not discussed here.

43 PARTICLE ACCELERATORS↗

Estimates of Power Radiated by the Beam in Bends of LCLS-II

In the injector region of LCLS-II the bunches pass through bends in the chicanes of the laser heater, of BC1 and BC2, and in the dogleg after the linac. The bunch repetition rate will be high, 1 MHz, and one would like to know the coherent synchrotron radiation (CSR) power radiated in the bends. We are particularly concerned about power that might radiate into cryomodules; however, for completeness we will perform calculations for all the bends in the laser heater, BC1, BC2, and the dogleg. In this note we estimate the CSR power for Gaussian (longitudinal) bunch distributions, using simple free-space and shielded CSR wake models. In the Appendix we repeat the calculations for more realistic bunch shapes obtained by numerical simulation. Finally, for completeness, we also calculate the incoherent synchrotron radiation (ISR) generated in the bends. Even though the ISR power radiated will be much less than the CSR power, it is of special interest because the spectrum reaches to much higher frequencies.

43 PARTICLE ACCELERATORS↗

Status of High Order Modes Spectra Measurements in 1.3 GHz Cavities for LCLS-II [Slides]

Production and testing of 1.3 GHz cryomodules for the LCLS-II project is ongoing at Fermilab. Each cryomodule is assembled of eight superconducting TESLA-shape elliptical cavities equipped with two High Order Mode (HOM) coupler ports. Measurement of the HOM spectrum is a part of the cavities incoming quality control inspection and the final cryomodule qualification cold test at the Cryomodule Test Facility (CMTF). In this paper we describe the procedure of HOM spectrum measurement and present the accumulated statistics of HOM frequencies and quality factors relevant to multiply cavity vendors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Results from Extended Range SRF Cavity Tuner Tests for LCLS-II HE

The LCLS-II HE superconducting linac can produce multi-energy beams by supporting multiple undulator lines simultaneously. This could be achieved by using the cavity SRF tuner in the off-frequency detune mode. This off-frequency operation method was tested in 8 cryomodules at Fermilab at 2 K. In all tests, the tuners achieved a frequency shift of -565±80 kHz. This study will discuss cavity frequency during each step as it is being assembled in the cryomodule string and finally when it is being tested at 2 K. Tracking the cavity frequency helped enable the tuners to reach this large frequency shift. The specific procedures of tuner setting during assembly will be presented

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

HOM Spectra Measurements in 1.3 GHz Cavities for LCLS-II

Fermilab recently completed production and testing of 1.3 GHz cryomodules for the LCLS-II project. Each cryomodule consists of eight TESLA-shaped super-conducting elliptical cavities equipped with two High Order Mode (HOM) coupler ports. Measurement of the HOM spectrum is part of the incoming quality control of cavities at room temperature and the final qualification cold test of cryomodules at the Cryomodule Test Facility (CMTF). In this paper we describe the procedure for measuring the HOM spectrum along with further data processing. Finally, we present accumulated statistics of individual HOM frequencies and quality factors related to various cavity vendors and dis-cuss the possible contribution of HOMs to heat loads and beam dynamics.

Lunin, A.↗

Operating the LCLS Gas Attenuator and Gas Detector System with Apertures of 6mm Diameter

The possibility of increasing the apertures of the LCLS gas attenuator/gas detector system is considered. It is shown that increase of the apertures from 3 to 6 mm, together with 4-fold reduction of the operation pressure does not adversely affect the vacuum conditions upstream or downstream. No change of the pump speed and the lengths of the differential pumping cells is required. One minor modification is the use of 1.5 cm long tubular apertures in the end cells of the differential pumping system. Reduction of the pressure does not affect performance of the gas attenuator/gas detector system at the FEL energies below, roughly, 2 keV. Some minor performance degradation occurs at higher energies.

Ryutov, D. D.↗

Coherence Properties of the LCLS

The LINAC Coherent Light Source (LCLS), an X-Ray free-electron laser(FEL) based on the self amplified spontaneous emission principle, has recently come on-line. For many users it is desirable to have an idea of the level of transverse coherence of the X-Ray beam produced. In this paper, we analyze the output of GENESIS simulations of electrons traveling through the FEL. We first test the validity of an approach that ignores the details of how the beam was produced, and instead, by assuming a Gaussian-Schell model of transverse coherence, predicts the level of transverse coherence simply through looking at the beam radius at several longitudinal slices. We then develop a Markov chain Monte Carlo approach to calculating the degree of transverse coherence, which offers a {approx}100-fold speedup compared to the brute-force algorithm previously in use. We find the beam highly coherent. Using a similar Markov chain Monte Carlo approach, we estimate the reasonability of assuming the beam to have a Gaussian-Schell model of transverse coherence, with inconclusive results.

Ocko, Samuel↗