Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Interfacial tension”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Probing specific ion effects at air-aqueous dibutyl phosphate interfaces using vibrational sum frequency generation spectroscopy

Molecular properties at air–liquid and liquid–liquid interface hold the key to many processes involving molecular transport across phase boundaries from aerosol formation to carbon cycling and material separation using solvent extraction techniques. Using dibutyl phosphate (DBP) as a representative for partially aqueous soluble surfactants, the specific ion effect (SIE) of the Hofmeister series cations Cs + , Na + , Li + , and Mg 2+ on the partition and interaction between surfactant molecules and water molecules in the air–aqueous interface are investigated using vibrational sum frequency generation spectroscopy and surface tension measurements. In the presence of 1 mM and 1M bulk aqueous phase ionic strength salt concentrations, fundamental qualitative relationships are observed for the salting out of DBP relative to bulk aqueous phase nitrate salt concentrations and the specific cations species. At 1 mM ionic strength, the interfacial charge and hence the interfacial potential modulates the electrostatic interactions; in particular, the counter cations partially screen the negatively charged interface induced by the DBP in a direct Hofmeister order. At 1M ionic strength, the electric field at the interface or interfacial potential is effectively neutralized, and the counter cations promote the partitioning of DBP to the interface depending on their specific interaction with the DBP head group and metal ion hydration properties. The present results lay a foundation to study SIEs of heavier metals on hydrophobic-aqueous DBP interfaces.

Louie, Christina [Washington State University, Pul↗

Large-scale molecular dynamics simulations of bubble collapse in water: Effects of system size, water model, and nitrogen

Molecular dynamics simulations in the microcanonical ensemble are performed to study the collapse of a bubble in liquid water using the single-site mW and the four-site TIP4P/2005 water models. To study system size effects, simulations for pure water systems are performed using periodically replicated simulation boxes with linear dimensions, L, ranging from 32 to 512 nm with the largest systems containing 8.7 × 10 6 and 4.5 × 10 9 molecules for the TIP4P/2005 and mW water models, respectively. The computationally more efficient mW water model allows us to reach converging behavior when the bubble dynamics results are plotted in reduced units, and the limiting behavior can be obtained through linear extrapolation in L –1 . Qualitative differences are observed between simulations with the mW and TIP4P/2005 water models, but they can be explained by the models’ differences in predicted viscosity and surface tension. Although bubble collapse occurs on time scales of only hundreds of picoseconds, the system sizes used here are sufficiently large to obtain bubble dynamics consistent with the Rayleigh–Plesset equation when using the models’ thermophysical properties as input. For the conditions explored here, extreme heating of the interfacial water molecules near the time of collapse is observed for the larger mW water systems (but the model underpredicts the viscosity), whereas heating is less pronounced for the TIP4P/2005 water systems because its larger viscosity contribution slows the collapse dynamics. The presence of nitrogen within the bubble only starts to affect bubble dynamics near the very end of the initial collapse, leading to an incomplete collapse and strong rebound for the mW water model. Although nitrogen is non-condensable at 300 K, it becomes highly compressed and reaches a liquid-like density near the collapse point. We find that the dissolution of nitrogen is much slower than the movement of the collapsing water front, and the re-expansion of the dense nitrogen droplet gives rise to bubble rebound. The incompatibility of the collapse and dissolution time scales should be considered for continuum-scale modeling of bubble dynamics. Finally, we also confirm that the diffusion coefficient for dissolved nitrogen is insensitive to pressure as the liquid transitions from a compressed to a stretched state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensitivity of the strength and toughness of concrete to the properties of the interfacial transition zone

We report Civil infrastructure is made primarily of concrete structures or components and therefore understanding durability and fracture behavior of concrete is of utmost importance. Concrete contains an interfacial transition zone (ITZ), a porous region surrounding the aggregates, that is often considered to be the weakest region in the concrete. The ITZ is poorly characterized and property estimates for the ITZ differ considerably. In this simulation study, representative concrete mesostructures are produced by packing coarse aggregates with realistic geometries into a mortar matrix. A meshless numerical method, peridynamics, is utilized to simulate the mechanical response including fracture under uniaxial compression and tension. The sensitivity of the stiffness and fracture toughness of the samples to the ITZ properties is computed, showing strong relationships between the ITZ properties and the effective modulus and effective yield strength of the concrete. These results provides insight into the influence of the poorly characterized ITZ on the stiffness and strength of concrete. This work showcases the applicability of peridynamics to concrete systems, matching experimental strength and modulus values. Additionally, relationships between the ITZ’s mechanical properties and the overall concrete strength and stiffness are presented to enable future design decisions.

36 MATERIALS SCIENCE↗

The Velocity and Attenuation of Acoustic Emission Waves in SiC/SiC Composites Loaded in Tension

The behavior of acoustic waves produced by microfracture events and from pencil lead breaks was studied for two different silicon carbide fiber-reinforced silicon carbide matrix composites. The two composite systems both consisted of Hi-Nicalon (trademark) fibers and carbon interfaces but had different matrix compositions that led to considerable differences in damage accumulation and acoustic response. This behavior was primarily due to an order of magnitude difference in the interfacial shear stress for the two composite systems. Load/unload/reload tensile tests were performed and measurements were made over the entire stress range in order to determine the stress-dependence of acoustic activity for increasing damage states. It was found that using the extensional wave velocities from acoustic emission (AE) events produced from pencil lead breaks performed outside of the transducers enabled accurate measurements of the stiffness of the composite. The extensional wave velocities changed as a function of the damage state and the stress where the measurement was taken. Attenuation for AE waveforms from the pencil lead breaks occurred only for the composite possessing the lower interfacial shear stress and only at significantly high stresses. At zero stress after unloading from a peak stress, no attenuation occurred for this composite because of crack closure. For the high interfacial stress composite no attenuation was discernable at peak or zero stress over the entire stress-range of the composite. From these observations, it is believed that attenuation of AE waveforms is dependent on the magnitude of matrix crack opening.

Morscher, Gregory N.↗

Coupling of Adhesion and Anti-Freezing Properties in Hydrogel Electrolytes for Low-Temperature Aqueous-Based Hybrid Capacitors

Solid-state zinc-ion capacitors are emerging as promising candidates for large-scale energy storage owing to improved safety, mechanical and thermal stability and easy-to-direct stacking. Hydrogel electrolytes are appealing solid-state electrolytes because of eco-friendliness, high conductivity and intrinsic flexibility. However, the electrolyte/electrode interfacial contact and anti-freezing properties of current hydrogel electrolytes are still challenging for practical applications of zinc-ion capacitors. Here, we report a class of hydrogel electrolytes that couple high interfacial adhesion and anti-freezing performance. The synergy of tough hydrogel matrix and chemical anchorage enables a well-adhered interface between hydrogel electrolyte and electrode. Meanwhile, the cooperative solvation of ZnCl 2 and LiCl hybrid salts renders the hydrogel electrolyte high ionic conductivity and mechanical elasticity simultaneously at low temperatures. More significantly, the Zn||carbon nanotubes hybrid capacitor based on this hydrogel electrolyte exhibits low-temperature capacitive performance, delivering high-energy density of 39 Wh kg –1 at –60 °C with capacity retention of 98.7% over 10,000 cycles. With the benefits of the well-adhered electrolyte/electrode interface and the anti-freezing hydrogel electrolyte, the Zn/Li hybrid capacitor is able to accommodate dynamic deformations and function well under 1000 tension cycles even at –60 °C. This work provides a powerful strategy for enabling stable operation of low-temperature zinc-ion capacitors.

25 ENERGY STORAGE↗

Steady thermocapillary flows in two-dimensional slots

Liquid in a slot flows owing to a temperature gradient applied along its free surface. The thermal variation of surface tension induces a steady viscous flow directed on the surface from hot to cold, and recirculating below. For small aspect ratios A, giving flow in thin, two-dimensional slots, an asymptotic theory valid for A yields to 0 is used to obtain the fluid and thermal fields as well as the interfacial shapes. Solutions are obtained for both fixed lines and fixed angles at the contact between the interface and the solid side walls.

Sen, A. K.↗

Ultrasonic additive manufacturing of zirconium: Pilot results

Ultrasonic additive manufacturing (UAM) was successfully applied to the Zirconium material system to create a three-dimensional component prototype. The UAM process resulted in grain size refinement and significant localized deformation. Electron backscatter diffraction analysis revealed activated slip systems only applicable at high deformation temperatures, while texture analysis showed a decrease in measurable texture of the UAM build in comparison to the initial Zr-foil. Average tensile strengths in the X (sonotrode travel), Y (vibration), and Z (build) directions averaged 435 MPa, 458 MPa, and 359 MPa, respectively, demonstrating the viability of UAM for Zr-based materials. Furthermore, the delamination of some Z specimens along foil boundaries during loading suggests an interplay between interfacial Ti impurities introduced during welding and the spatial dependence of weld quality for this material system.

36 MATERIALS SCIENCE↗

The Effect of Solidification Rate on Morphological Stability

At low solidification rates, the criterion for the onset of morphological instability parallels closely the criterion of constitutional supercooling. At somewhat larger rates of solidification, however, the results of the perturbation theory of morphological instability differ significantly from the predictions of constitutional supercooling. This arises because the critical wave length for instability decreases as solidification rate increases and thus the effects of capillarity (solid-liquid surface tension) play a strong stabilizing role. This gives rise to the concept of absolute stability, according to which the system will always be stable for a sufficiently large rate of solidification. This enhanced stabilization by capillarity is present only so long as local equilibrium is maintained at the solid-liquid interface. If the interfacial temperature drops below its equilibrium value by an amount dependent on growth rate, oscillatory morphological instabilities can occur. The differences among these various stability criteria are illustrated by means of some simple two-dimensional diagrams that should supplant the conventional plots of (temperature gradient)/(growth rate) vs. alloy concentration.

Sekerka, R. F.↗

Investigation of Body Force Effects on Flow Boiling Critical Heat Flux

The bubble coalescence and interfacial instabilities that are important to modeling critical heat flux (CHF) in reduced-gravity systems can be sensitive to even minute body forces. Understanding these complex phenomena is vital to the design and safe implementation of two-phase thermal management loops proposed for space and planetary-based thermal systems. While reduced gravity conditions cannot be accurately simulated in 1g ground-based experiments, such experiments can help isolate the effects of the various forces (body force, surface tension force and inertia) which influence flow boiling CHF. In this project, the effects of the component of body force perpendicular to a heated wall were examined by conducting 1g flow boiling experiments at different orientations. FC-72 liquid was boiled along one wall of a transparent rectangular flow channel that permitted photographic study of the vapor-liquid interface at conditions approaching CHF. High-speed video imaging was employed to capture dominant CHF mechanisms. Six different CHF regimes were identified: Wavy Vapor Layer, Pool Boiling, Stratification, Vapor Counterflow, Vapor Stagnation, and Separated Concurrent Vapor Flow. CHF showed great sensitivity to orientation for flow velocities below 0.2 m/s, where very small CHF values where measured, especially with downflow and downward-facing heated wall orientations. High flow velocities dampened the effects of orientation considerably. Figure I shows representative images for the different CHF regimes. The Wavy Vapor Layer regime was dominant for all high velocities and most orientations, while all other regimes were encountered at low velocities, in the downflow and/or downward-facing heated wall orientations. The Interfacial Lift-off model was modified to predict the effects of orientation on CHF for the dominant Wavy Vapor Layer regime. The photographic study captured a fairly continuous wavy vapor layer travelling along the heated wall while permitting liquid contact only in wetting fronts, located in the troughs of the interfacial waves. CHF commenced when wetting fronts near the outlet were lifted off the wall. The Interfacial Lift-off model is shown to be an effective tool for predicting the effects of body force on CHF at high velocities.

Zhang, Hui↗

A Deep Potential model for liquid–vapor equilibrium and cavitation rates of water

Computational studies of liquid water and its phase transition into vapor have traditionally been performed using classical water models. Here, we utilize the Deep Potential methodology—a machine learning approach—to study this ubiquitous phase transition, starting from the phase diagram in the liquid–vapor coexistence regime. The machine learning model is trained on ab initio energies and forces based on the SCAN density functional, which has been previously shown to reproduce solid phases and other properties of water. Here, we compute the surface tension, saturation pressure, and enthalpy of vaporization for a range of temperatures spanning from 300 to 600 K and evaluate the Deep Potential model performance against experimental results and the semiempirical TIP4P/2005 classical model. Moreover, by employing the seeding technique, we evaluate the free energy barrier and nucleation rate at negative pressures for the isotherm of 296.4 K. Further, we find that the nucleation rates obtained from the Deep Potential model deviate from those computed for the TIP4P/2005 water model due to an underestimation in the surface tension from the Deep Potential model. From analysis of the seeding simulations, we also evaluate the Tolman length for the Deep Potential water model, which is (0.091 ± 0.008) nm at 296.4 K. Finally, we identify that water molecules display a preferential orientation in the liquid–vapor interface, in which H atoms tend to point toward the vapor phase to maximize the enthalpic gain of interfacial molecules. We find that this behavior is more pronounced for planar interfaces than for the curved interfaces in bubbles. This work represents the first application of Deep Potential models to the study of liquid–vapor coexistence and water cavitation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temperature-dependent tensile and shear response of graphite/aluminum

The thermo-mechanical response of unidirectional P100 graphite fiber/6061 aluminum matrix composites was investigated at four temperatures:-150, +75, +250, and +500 F. Two types of tests, off-axis tension and losipescu shear, were used to obtain the desired properties. Good experimental-theoretical correlation was obtained for Exx, vxy, and G12. It is shown that E11 is temperature independent, but E22, v12, and G12 generally decrease with increasing temperature. Compared with rather high longitudinal strength, very low transverse strength was obtained for the graphite/aluminum. The poor transverse strength is believed to be due to the low interfacial bond strength in this material. The strength decrease significantly with increasing temperature. The tensile response at various temperatures is greatly affected by the residual stresses caused by the mismatch in the coefficients of thermal expansion of fibers and matrix. The degradation of the aluminum matrix properties at higher temperatures has a deleterious effect on composite properties. The composite has a very low coefficient of thermal expansion in the fiber direction.

Fujita, T.↗

Development of a torsion balance for adhesion measurements

A new torsion balance for study of adhesion in ceramics is discussed. A torsion wire and a linear variable differential transformer are used to monitor load and to measure pull-off force (adhesion force). The investigation suggests that this torsion balance is valuable in studying the interfacial properties of ceramics in controlled environments such as in ultrahigh vacuum. The pull-off forces measured in dry, moist, and saturated nitrogen atmosphere demonstrate that the adhesion of silicon nitride contacts remains low at humidities below 80 percent but rises rapidly above that. The adhesion at saturation is 10 times or more greater than that below 80 percent relative humidity. The adhesion in a saturated atmosphere arises primarily from the surface tension effects of a thin film of water adsorbed on the surface. The surface tension of the water film was 58 x 10 to the minus 5 to 65 x 10 to the minus 5 power. The accepted value for water is 72.7 x 10 to the minus 5 power N/cm. Adhesion characteristics of silicon nitride in contact with metals, like the friction characteristics of silicon carbide to metal contacts, can be related to the relative chemical activity of metals in ultrahigh vacuum. The more active the metal, the higher the adhesion.

Miyoshi, Kazuhisa↗

The CapiSorb Visible System (CVS) Demonstrations on ISS

Falling liquid film amine sorbent reactors have been successfully employed to scrub CO 2 aboard submarines for decades. However, applying such proven methods aboard orbiting and coast spacecraft is significantly challenged by the nearly weightless environment, where liquid sprays and films do not fall, and vapor bubbles and gases do not rise. The Capillary Sorbent (CapiSorb) Visible System (CVS) is a technology demonstration experiment performed aboard the ISS April 18 – 21, 2023. The system establishes stable steady thin liquid film flows in Contactor (absorber) and Degasser (desorber/stripper) replacing the passive role of gravity with the combined passive roles of surface tension, wetting, and system geometry. A TOX-0 fructose ersatz liquid sorbent is employed enabling ‘transparent’ experiments performed and filmed by the crew safely in the open cabin of the ISS. Completed objectives include demonstrations of stable passive ‘massively’ parallel planar thin film capillary flows across atmospheric pressure Contactor and sealed heated Degasser. The impacts of varying flow rate, flow direction, heat input, viscosity, positive and negative Degasser pressures, condensate collection and return, fluid distribution, interfacial stability, and others are reported. At least 49 diagnostics are recorded for digitization and subsequent thermal-fluids model validation by a single HD video downlink during the nearly 22 hours of operations. An overview of the flight hardware including description of the components, diagnostics, crew procedures, flight operations, and summary of accomplishments is reported in Ref. 1. Further details of the diagnostics, tests performed, and data reduction is reported in Ref. 2. This report collects both1,2 into a single report adding methods of data digitization, reduction, and archive along with analyses and discussions of technology impacts.

microgravity↗

Computational Analysis of the Effect of Structured Packing Design on Absorption Column Hydrodynamics for Post-Combustion Carbon Capture Applications

Solvent based post-combustion carbon capture technologies have a potential for reducing carbon emissions from fossil-fuel-fired power plants and industrial sources where CO2 emissions are inherently harder to mitigate, such as steel or cement industries. A prominent technology to achieve this is by retrofitting absorption columns to the existing infrastructure. While these systems have been among the less costly alternatives for carbon capture, they still impose a considerable energy penalty to the operation of power plants or industrial facilities. The optimization of CO2 capture rate in solvent-based absorption process is complex as it depends on several factors including CO2 solubility, solvent reaction kinetics and temperature effects on the solubility, reaction rates, surface tension, and thermophysical properties of the solvent and the flue gas. The overall heat and mass transfer also depends on the hydrodynamics, which in turn, is affected by the packing geometry. In the current work, we systematically quantify the effects the design of the structured packing has on the column hydrodynamics, by performing detailed CFD simulations for different geometrical configurations and operating conditions. We then obtain relationships between the key hydrodynamic metrics, such as liquid holdup, interfacial area, wetted area, and pressure drop to the parameters defining the packing geometries and identify new more effective packing designs for the given operating conditions.

Shah, Yash Girish↗

Crystal growth and fluid mechanics problems in directional solidification

Broadly speaking, our efforts have been concentrated in two aspects of directional solidification: (A) a more complete theoretical understanding of convection effects in a Bridgman apparatus; and (B) a clear understanding of scalings of various features of dendritic crystal growth in the sensitive limit of small capillary effects. For studies that fall within class A, the principal objectives are as follows: (A1) Derive analytical formulas for segregation, interfacial shape and fluid velocities in mathematically amenable asymptotic limits. (A2) Numerically verify and extend asymptotic results to other ranges of parameter space with a view to a broader physical understanding of the general trends. With respect to studies that fall within class B, the principal objectives include answering the following questions about dendritic crystal growth: (B1) Are there unsteady dendrite solutions in 2-D to the completely nonlinear time evolving equations in the small surface tension limit with only a locally steady tip region with well defined tip radius and velocity? Is anisotropy in surface tension necessary for the existence of such solutions as it is for a true steady state needle crystal? How does the size of such a local region depend on capillary effects, anisotropy and undercooling? (B2) How do the different control parameters affect the nonlinear amplification of tip noise and dendritic side branch coarsening?

Tanveer, Saleh↗

Tribology Experiment in Zero Gravity

A tribology experiment in zero gravity was performed during the orbital flight of Spacelab 1 to study the motion of liquid lubricants over solid surfaces. The absence of a significant gravitational force facilitates observation of such motions as controlled by interfacial and capillary forces. Two experimental configurations were used. One deals with the liquid on one solid surface, and the other with the liquid between a pair of closed spaced surfaces. Time sequence photographs of fluid motion on a solid surface yielded spreading rate data of several fluid-surface combinations. In general, a slow spreading process as governed by the tertiary junction can be distinguished from a more rapid process which is driven by surface tension controlled internal fluid pressure. Photographs were also taken through the transparent bushings of several experimental journal bearings. Morphology of incomplete fluid films and its fluctuation with time suggest the presence or absence of unsteady phenomena of the bearing-rotor system in various arrangements.

Pan, C. H. T.↗

Temperature-dependent tensile and shear response of P100/6061 graphite-aluminum

This paper summarizes the results of an investigation conducted to characterize tensile and shear response of P100/6061 graphite-aluminum composite in the temperature range -101 to 260 C. The off-axis tension test and Iosipescu shear test methods were employed to meet this objective. The experimental results indicate that both the fiber-dominated and matrix-dominated elastic properties exhibit relatively small changes in the considered temperature range. The effect of temperature on yielding and strength, however, is significant under longitudinal and shear loading. Residual stresses play a significant role in controlling the variation of the yield stress with temperature. The observed low transverse strength of the composite is explained by interfacial defects between adjacent precursor wires induced during fabrication.

Fujita, Takahiro↗

Macrovoid Defect Growth during Evaporative Casting of Polymeric Membranes

Macrovoid (MV) formation is a significant problem in evaporatively cast polymeric membranes. MVs are large, elongated or teardrop-shaped pores (~10-50 micron) that can impair membrane structural integrity. Although MVs have been extensively studied, there is no general agreement on the mechanisms governing MV growth. Recently, our research group has formulated the solutocapillary convection (SC) hypothesis, which contends that MV growth involves three principal forces: a Marangoni force generated by surface tension gradients within the MV interface, a viscous drag force, and a gravitationally induced body force. Two sets of complementary experiments were conducted to test the SC hypothesis. Ground-based videomicroscopy flow-visualization (VMFV) was utilized to measure the flow velocities at the MV-casting solution interface and deep within the casting solution. The measurements were performed with casting solutions containing 10 wt% cellulose acetate (CA), 30 wt% H2O, 60 wt% acetone, and 200- ppm TiO2 particles for flow visualization, and the surface tension was controlled by surfactant addition. Qualitatively, the experiments indicated that MV growth occurs in three distinct phases: (1) a very rapid initial growth period, (2) a much slower growth phase, and (3) absorption of selected MVs into the expanding demixed region. The presence of tracer particles inside the MVs suggests the presence of a convective flow, which transfers the particles from the bulk solution to the MV interior. Although the VMFV experiments did not establish any surfactant effect on the interfacial velocities, a statistically significant effect on the MV number density was observed. In the second set of experiments, membranes were cast aboard a KC-135 aircraft under 0-g and 2-g conditions. Despite careful attention to the design and fabrication of the membrane casting apparatus (MCA), several problems were encountered, the most significant of which was the contamination of the casting solution by the activated carbon particles used for solvent absorption.

Greenberg, A. R.↗