Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrumentation and Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

TESS Data Release Notes: Sectors 1 – 36, Multi-sector Search, DR53

These Data Release Notes provide information on the processing and export of data from the Transiting Exoplanet Survey Satellite (TESS). This data release is a combined, multi-sector transit search only. The underlying data products from individual observing sectors have been previously released. The data products included in this data release are the Data Validation (DV) reports, time series, and associated xml files for the threshold crossing events (TCEs) found by searching a combined data set including data from multiple observing sectors. These data products were generated by the TESS Science Processing Operations Center (SPOC, Jenkins et al., 2016) at NASA Ames Research Center from data collected by the TESS instrument, which is managed by the TESS Payload Operations Center (POC) at Massachusetts Institute of Technology (MIT). The format and content of these data products are documented in the Science Data Products Description Document (SDPDD)1. The SPOC science algorithms are based heavily on those of the Kepler Mission science pipeline, and are described in the Kepler Data Processing Handbook (Jenkins, 2020)2. The Data Validation algorithms are documented in Twicken et al. (2018) and Li et al. (2019). The TESS Instrument Handbook (Vanderspek et al., 2018) contains more information about the TESS instrument design, detector layout, data properties, and mission operations. The TESS Mission is funded by NASA's Science Mission Directorate.

TESS↗

Final Report on Radiation Measurements Performed Inside of the BEAM Module

Measurements of the radiation environment inside of the Bigelow Expandable Activity Module (BEAM) have been made on a pseudo-continuous basis since June 6, 2016 using both passive and active instrumentation. Passive detectors yield a single cumulative dose value (or average daily dose) over the measurement period from deploy to return to ground. Active Radiation Environment Monitor (REM) sensors yield dose rate, Linear Energy Transfer (LET) spectra, and particle-specific dose, all on a 1-minute cadence. From the initial install in 2016 until early 2018, BEAM was an empty module. In 2018, further testing was approved and stowage began to be moved into BEAM. As a result, it was decided to stop measurements with RAM detectors to avoid potential difficulties with access after stowage was added. The REM sensors remained however in the original deploy locations.

radiation exposure↗

The IAU Recommended Photometric System for Ultraviolet Astronomy

In the current era when access to space is becoming easier and at a lower cost thanks to the standardised cubesat technology, numerous missions are expected to be launched to observe, particularly, at ultraviolet wavelengths. Given the reduced dimensions of the telescope that a cubesat can carry, most of these missions will be focused on photometric surveys of a reduced sample of targets of interest, and therefore each mission will define their own photometric bands according to their scientific objectives and orbital constraints. However, in order to provide a coherent view of the ultraviolet sky, the data should be post-processed under a common framework. In 2017, the IAU working group on ultraviolet astronomy identified the need to define such a common framework for the upcoming ultraviolet missions, and coordinated the definition of a standard set of photometric bands that could serve for homogenizing the current and future data. This paper presents the procedure adopted by the working group for the definition of the standard photometric system, that was approved by the IAU during the General Assembly Business Sessions held in August, 2021. The photometric system consists of seven bands, denoted as UV1-UV7, all included in the range 115 - 400 nm. Some of these bands are based on existing filters, while others have been defined as theoretical bands with constant throughput. This system is to be regarded as a set of synthetic bands for post-processing the data of any mission, and an example of its application to the SPARCS cubesat is also included. The photometric bands are publicly available and can be downloaded from https://www.nuva.eu/uv-photometry/.

Ultraviolet: ISM↗

Dose Calibration of the ISS-RAD Fast Neutron Detector

The ISS-RAD instrument has been fabricated by Southwest Research Institute and delivered to NASA for flight to the ISS in late 2015 or early 2016. ISS-RAD is essentially two instruments that share a common interface to ISS. The two instruments are the Charged Particle Detector (CPD), which is very similar to the MSL-RAD detector on Mars, and the Fast Neutron Detector (FND), which is a boron-loaded plastic scintillator with readout optimized for the 0.5 to 10 MeV energy range. As the FND is completely new, it has been necessary to develop methodology to allow it to be used to measure the neutron dose and dose equivalent. This talk will focus on the methods developed and their implementation using calibration data obtained in quasi-monoenergetic (QMN) neutron fields at the PTB facility in Braunschweig, Germany. The QMN data allow us to determine an approximate response function, from which we estimate dose and dose equivalent contributions per detected neutron as a function of the pulse height. We refer to these as the "pSv per count" curves for dose equivalent and the "pGy per count" curves for dose. The FND is required to provide a dose equivalent measurement with an accuracy of 10% of the known value in a calibrated AmBe field. Four variants of the analysis method were developed, corresponding to two different approximations of the pSv per count curve, and two different implementations, one for real-time analysis onboard ISS and one for ground analysis. We will show that the preferred method, when applied in either real-time or ground analysis, yields good accuracy for the AmBe field. We find that the real-time algorithm is more susceptible to chance-coincidence background than is the algorithm used in ground analysis, so that the best estimates will come from the latter.

Zeitlin, C.↗

Detector Array Assembly Development for the ATLAS Instrument on the ICESat-2 Mission

This paper describes the development of the Detector Array Assembly (DAA) structure for the Advanced Topographic Laser Altimeter System (ATLAS) on the ICESat2 Mission built at NASA Goddard Space Flight Center (GSFC). It describes the challenges faced in designing a structure to protect sensitive detectors with limited data available for the detectors and the environment, including shock. The paper shows the successful re-design and testing that was performed to allow for a design to handle launch, shock and thermal environments with flexibility to incorporate design changes.

0000↗

HFI Bolometer Detectors Programmatic CDR

Programmatic Critical Design Review (CDR) of the High Frequency Instrument (HFI) Bolometer Detector on the Planck Surveyor is presented. The topics include: 1) Scientific Requirements and Goals; 2) Silicon Nitride Micromesh 'Spider-Web' Bolometers; 3) Sub-Orbital Heritage: BOOMERANG; 4) Noise stability demonstrated in BOOMERANG; 5) Instrument Partners; 6) Bolometer Environment on Planck/HFI; 7) Bolometer Modules; and 8) Mechanical Interface. Also included are the status of the receivables and delivery plans with Europe. This paper is presented in viewgraph form.

Lange, Andrew E.↗

Segmented Ge detectors and mechanical coolers for future gamma-ray astronomy instruments

The effectiveness of a segmented Ge detector in rejecting background events due to the beta decay of internal radioactivity is demonstrated by a laboratory experiment in which radioactivity was produced in the detector by neutron irradiation. A Cf-252 source of neutrons was used to produce, by neutron capture on Ge-74 in the detector itself, Ge-75, which decays by beta emission with a maximum energy of 1188 keV. Simultaneous spectra are taken of the activity in the detector under two conditions: a free spectrum in which all events in the detector are accumulated, and a gated spectrum in which events are accumulated only if they deposit energy in two or more segments. A comparison of the spectra shows that over 85 percent of the beta events are rejected, which is in good agreement with predictions.

Varnell, Larry S.↗

Development of a large pixel, spectrally optimized, pinned photodiode/interline charge coupled device (CCD) detector for the Earth Observing System (EOS)/Moderate-Resolution Imaging Spectrometer-Tilt (MODIS-T) instrument

A pinned photodiode/interline CCD Detector Array is under development for the EOS/MODIS-T project. Outstanding features of the device include large pixels, spectrally optimized fill factors, and blooming protection. The detector has 30 spatial rows and 32 spectral columns. The device layout is split into two halves; each half has its own detector area, storage area, and output structure.

Ewin, Audrey J.↗

Nuclear Science Symposium, 30th, and Symposium on Nuclear Power Systems, 15th, San Francisco, CA, October 19-21, 1983, Proceedings

The range of disciplines covered includes physics instrumentation, data acquisition, FASTBUS, radiation detectors, scintillators, photomultipliers and optical detectors, subnanosecond 2-D imaging, medical and health instrumentation, reactor instrumentation, and space instrumentation. Cerenkov detectors, the prevention and rate capability of breakdown processes in wire chambers, and an interactive parallel processor for data analysis are studied. Attention is also given to bismuth germanate's role in gamma-ray spectroscopy, and the construction of a broadband universal sampling head is described. Gamma-ray imaging with a rotating hexagonal uniform redundant array, and broadband X-ray astronomical spectrometry are considered.

Nakamura, M.↗

Thermodynamic Performance of the 3-Stage ADR for the Astro-H Soft X-Ray Spectrometer Instrument

The Soft X-ray Spectrometer (SXS) instrument[1] on Astro-H[2] will use a 3-stage ADR[3] to cool the microcalorimeter array to 50 mK. In the primary operating mode, two stages of the ADR cool the detectors using superfluid helium at ≤1.20 K as the heat sink[4]. In the secondary mode, which is activated when the liquid helium is depleted, the ADR uses a 4.5 K Joule-Thomson cooler as its heat sink. In this mode, all three stages operate together to continuously cool the (empty) helium tank and singleshot cool the detectors. The flight instrument - dewar, ADR, detectors and electronics - were integrated in 2014 and have since undergone extensive performance testing. This paper presents a thermodynamic analysis of the ADR's operation, including cooling capacity, heat rejection to the heat sinks, and various measures of efficiency.

adiabatic demagnetization refrigerator↗

A program of correlated observations using the EGRET instrument on GRO and the IMB neutrino detector

A reliable, real-time supernova monitoring system was devised using the IMB neutrino detector to serve as an 'early-warning' system for EGRET and other instruments on GRO. New methods and software were developed to allow the IMB monitoring computer in Cleveland to: recognize that a trigger burst had occurred; make a judgement on whether the burst was spurrious or an actual supernova; prepare brief summary files and 'quick-look' data so that a final disposition could be made by a trained scientist; and contact the 'watch' scientist via personal beeper in Baton Rouge. This system ran from Dec. 1990 to Apr. 1991, when the neutrino detector failed for unrelated reasons. In addition to the supernova system, high-energy neutrino data was prepared and formatted for comparison with EGRET gamma-ray data.

Svoboda, Robert C.↗

Flux measurements using the BATSE spectroscopic detectors

Among the Compton Gama-Ray Observatory instruments, the BATSE Spectroscopic Detectors (SD) have the distinction of being able to detect photons of energies less than about 20 keV. This is an interesting energy range for the examination of low mass X-ray binaries (LMXB's). In fact, Sco X-1, the prototype LMXB, is easily seen even in the raw BATSE spectroscopic data. The all-sky coverage afforded by these detectors offers a unique opportunity to monitor this source over time periods never before possible. The aim of this investigation was to test a number of ways in which both continous and discrete flux measurements can be obtained using the BATSE spectroscopic datasets. A instrumental description of a SD can be found in the Compton Workshop of Apr. 1989, this report will deal only with methods which can be used to analyze its datasets. Many of the items discussed below, particularly in regard to the earth occultation technique, have been developed, refined, and applied by the BATSE team to the reduction of BATSE LAD data. Code written as part of this project utilizes portions of that work. The following discussions will first address issues related to the reduction of SD datasets using the earth occultation technique. It will then discuss methods for the recovery of the flux history of strong sources while they are above the earth's limb. The report will conclude with recommended reduction procedures.

Mcnamara, Bernard↗

Assessment of MODIS RSB Detector Uniformity Using Deep Convective Clouds

For satellite sensor, the striping observed in images is typically associated with the relative multiple detector gain difference derived from the calibration. A method using deep convective cloud (DCC) measurements to assess the difference among detectors after calibration is proposed and demonstrated for select reflective solar bands (RSBs) of the Moderate Resolution Imaging Spectroradiometer (MODIS). Each detector of MODIS RSB is calibrated independently using a solar diffuser (SD). Although the SD is expected to accurately characterize detector response, the uncertainties associated with the SD degradation and characterization result in inadequacies in the estimation of each detector's gain. This work takes advantage of the DCC technique to assess detector uniformity and scan mirror side difference for RSB. The detector differences for Terra MODIS Collection 6 are less than 1% for bands 1, 3-5, and 18 and up to 2% for bands 6, 19, and 26. The largest difference is up to 4% for band 7. Most Aqua bands have detector differences less than 0.5% except bands 19 and 26 with up to 1.5%. Normally, large differences occur for edge detectors. The long-term trending shows seasonal oscillations in detector differences for some bands, which are correlated with the instrument temperature. The detector uniformities were evaluated for both unaggregated and aggregated detectors for MODIS band 1 and bands 3-7, and their consistencies are verified. The assessment results were validated by applying a direct correction to reflectance images. These assessments can lead to improvements to the calibration algorithm and therefore a reduction in striping observed in the calibrated imagery.

Clouds↗

Evaluation of Radiometric Performance of CERES Instruments Aboard Terra

The Terra satellite platform carries the first two flight models of the Clouds and the Earth’s Radiant Energy System, which make radiometric measurements of the Earth to examine the roles of cloud feedback and radiation balance in the Earth System. The Terra-borne instruments use three channels: the shortwave (0.2 - 5 µm), total (0.2 – 100 µm) and window (8 – 12 µm), which are calibrated using an onboard internal calibration module to track the long-term stability of each channel. Observed measurements are converted to top-of-atmosphere radiances by accounting for the instrument optics and detector sensitivity coefficients determined from prelaunch calibrations. Trends in the instrument’s radiometric performance determined through on-orbit calibrations and vicarious studies were applied, and these corrections have shown to produce a stable data record of radiative fluxes over the lifetime of the mission. Changes in instrument observations and new methods to account for them as a result of the discontinuation of station keeping for Terra will be discussed.

Alexander Jarnot↗

GEM detectors for the CMS endcap muon system: status of three new detector stations

The High-Luminosity LHC (HL-LHC, or Phase-2 LHC) will deliver proton-proton collisions at 5–7.5 times the nominal LHC luminosity, with an expected number of 140–200 pp-interactions per bunch crossing (Pile-up or PU). To maintain the performance of muon triggering and reconstruction under high background, the forward part of the Muon Spectrometer of the CMS experiment will be upgraded with Gas Electron Multipliers (GEM) and improved Resistive Plate Chambers (iRPC) detectors. A first GEM station (GE1/1) was installed during Long Shutdown 2 (LS2, 2019–2021), a 2 nd station (GE2/1) of Triple-GEM detectors will be installed in winter 2023–24 and 2024–25, while a new 6-layer station (ME0) will be installed in the third Long Shutdown (LS3, 2026–2028). GE11 is considered an early Phase-2 upgrade as it will reduce the p T threshold by combining GEM and Cathode Strip Chamber (CSC) hits in the forward muon system at twice the LHC design luminosity ($\mathcal{L}$ = 2 · 10 34 cm -2 s -1 , 50 PU). After a successful start of Run-3 in 2022, with almost 40 fb -1 collected, the commissioning of the GE1/1 detector is nearly complete. Most chambers are operated stably with an efficiency in excess of 95%, next being the demonstration of the combined CSC-GEM trigger in 2023. The lessons learnt with the first large-area GEM station have lead to improvements in detector and electronics design for the Phase 2 detectors GE2/1 and ME0. This proceeding will discuss the progress made since last MPGD Conference (MPGD 2019), discussing the commissioning and early performance of GE1/1; the design improvements and start of construction of GE2/1; and the R&D currently ongoing for ME0.

47 OTHER INSTRUMENTATION↗

Nuclear Science Symposium, 31st and Symposium on Nuclear Power Systems, 16th, Orlando, FL, October 31-November 2, 1984, Proceedings

Topics related to physics instrumentation are discussed, taking into account cryostat and electronic development associated with multidetector spectrometer systems, the influence of materials and counting-rate effects on He-3 neutron spectrometry, a data acquisition system for time-resolved muscle experiments, and a sensitive null detector for precise measurements of integral linearity. Other subjects explored are concerned with space instrumentation, computer applications, detectors, instrumentation for high energy physics, instrumentation for nuclear medicine, environmental monitoring and health physics instrumentation, nuclear safeguards and reactor instrumentation, and a 1984 symposium on nuclear power systems. Attention is given to the application of multiprocessors to scientific problems, a large-scale computer facility for computational aerodynamics, a single-board 32-bit computer for the Fastbus, the integration of detector arrays and readout electronics on a single chip, and three-dimensional Monte Carlo simulation of the electron avalanche in a proportional counter.

Biggerstaff, J. A.↗

Optical proximity detector

Sensitive, relatively inexpensive instrument uses phase-detection techniques to sense presence of objects. Phase-sensitive detectors, LED, photodiode with response matched to LED output, and filtering lens allow detector to operate over narrow radiation band, giving selectivity over stray light.

Hermann, W. A.↗