Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Institution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Multi-Institutional Experience of Stereotactic Ablative Radiation Therapy for Stage I Small Cell Lung Cancer

Purpose: For inoperable stage I (T1-T2N0) small cell lung cancer (SCLC), national guidelines recommend chemotherapy with or without conventionally fractionated radiation therapy. The present multi-institutional cohort study investigated the role of stereotactic ablative radiation therapy (SABR) for this population. Methods and Materials: The clinical and treatment characteristics, toxicities, outcomes, and patterns of failure were assessed in patients with histologically confirmed stage T1-T2N0M0 SCLC. Kaplan-Meier analysis was used to evaluate the survival outcomes. Univariate and multivariate analyses identified predictors of outcomes. Results: From 24 institutions, 76 lesions were treated in 74 patients (median follow-up 18 months). The median age and tumor size was 72 years and 2.5 cm, respectively. Chemotherapy and prophylactic cranial irradiation were delivered in 56% and 23% of cases, respectively. The median SABR dose and fractionation was 50 Gy and 5 fractions. The 1- and 3-year local control rate was 97.4% and 96.1%, respectively. The median disease-free survival (DFS) duration was 49.7 months. The DFS rate was 58.3% and 53.2% at 1 and 3 years, respectively. The median, 1-year, and 3-year disease-specific survival was 52.3 months, 84.5%, and 64.4%, respectively. The median, 1-year, and 3-year overall survival (OS) was 17.8 months, 69.9%, and 34.0% respectively. Patients receiving chemotherapy experienced an increased median DFS (61.3 vs 9.0 months; P=.02) and OS (31.4 vs 14.3 months; P=.02). The receipt of chemotherapy independently predicted better outcomes for DFS/OS on multivariate analysis (P=.01). Toxicities were uncommon; 5.2% experienced grade ≥2 pneumonitis. Post-treatment failure was most commonly distant (45.8% of recurrence), followed by nodal (25.0%) and “elsewhere lung” (20.8%). The median time to each was 5 to 7 months. Conclusions: From the findings of the largest report of SABR for stage T1-T2N0 SCLC to date, SABR (≥50 Gy) with chemotherapy should be considered a standard option.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gaps in Radiation Therapy Awareness: Results From an Educational Multi-institutional Survey of US Internal Medicine Residents

Purpose: Internists and primary care providers play a growing role in cancer care. We therefore evaluated the awareness of radiation therapy in general and specifically the clinical utility of stereotactic body radiation therapy (SBRT) for early-stage non-small cell lung cancer (NSCLC) among current US internal medicine residents. Methods and Materials: A web-based institutional review board–approved multi-institutional survey was distributed to US internal medicine residency programs. The survey evaluated trainee demographic characteristics, baseline radiation oncology awareness, knowledge of the role of SBRT for early-stage NSCLC, and whether the survey successfully improved awareness. Results: Thirty US internal medicine programs participated, with an overall participant response rate of 46% (1177 of 2551). Of the trainees, 93% (n=1076) reported no radiation oncology education in their residency, 39% (n=452) reported confidence in knowing when to consult radiation oncology in an oncologic emergency, and 26% (n=293) reported confidence in knowing when to consult radiation oncology in the setting of a newly diagnosed cancer. Of the participants, 76% (n=850) correctly identified that surgical resection is the standard treatment in operable early-stage NSCLC, but only 50% (n=559) of participants would recommend SBRT to a medically inoperable patient, followed by 31% of participants (n=347) who were unsure of the most appropriate treatment, and 10% (n=117) who recommended waiting to offer palliative therapy. Ninety percent of participants (n=1029) agreed that they would benefit from further training on when to consult radiation oncology. Overall, 96% (n=1072) indicated that the survey increased their knowledge and awareness of the role of SBRT. Conclusions: The majority of participating trainees received no education in radiation oncology in their residency, reported a lack of confidence regarding when to consult radiation oncology, and overwhelmingly agreed that they would benefit from further training. These findings should serve as a call to increase the educational collaboration between internal medicine and radiation oncology departments to ensure optimal cancer care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Immobilization and image-guidance methods for radiation therapy of limb extremity soft tissue sarcomas: Results of a multi-institutional survey

Radiation therapy for limb-extremity soft tissue sarcoma (STS) requires accurate, reproducible dose delivery. However, patient positioning is challenging and there is a lack of existing guidelines to assist institutional standardization. Therefore, we conducted a multi-institutional international survey of STS immobilization, image guidance methods, and treatment protocols to investigate current practice. Seventy-three UK radiotherapy centers and 15 hospitals in 7 other countries completed a questionnaire on STS immobilization and image-guidance procedures. Specifically, the survey collated information on the current usage of immobilization equipment, including custom devices, patient setup tolerances, the use of written protocols, the modality and frequency of image guidance, the method of treatment, allocated treatment times, and the application of surgical clips. Multiple combinations of immobilization devices were reported. In the UK, 12%, 40%, 30%, 12%, and 5% use 1, 2, 3, 4, and 5 types of device for lower limb STS. Vacuum bag plus either foot or ankle support was most common (66%). Of 15 international centers, 27%, 60%, 7%, 0%, 7% use 1, 2, 3, 4, 5 devices, with vacuum bags (73%) and thermoplastic (47%) predominant, similar to UK values of 77% and 52%. For image guidance, in the UK, 37% use kV planar, 34% use MV planar, and 16% use cone-beam CT for the first 3 fractions and then weekly. Internationally, daily imaging was more prevalent with 33% using kV planar, 7% MV planar, and 40% cone-beam CT daily. Custom devices plus combinations of devices, along with 5- and 10-mm set-up tolerances, were most commonly reported. Less than half of centers have written treatment protocols. Conventional treatment is most common in the UK, with only 42% using conformal techniques. Treatment is allocated between 10 and 30 minutes. Twenty-six percent of UK centers and 53% of international centers use surgical clips. Across treatment centers, there is no consistent approach to STS immobilization, image-guidance methods, or treatment protocols assessed by this survey. A wide variety of immobilization devices and configurations are utilized, and the frequency and modality of imaging are similarly diverse. In the absence of guidelines, the creation of an online repository of example immobilization techniques could enable centers to compare a diversity of cases. The availability of a forum for viewing and discussing a range of cases could potentially lead to improved patient setup and reduce the time taken to devise an individual immobilization strategy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Resilient water infrastructure partnerships in institutionally complex systems face challenging supply and financial risk tradeoffs

Abstract As regions around the world invest billions in new infrastructure to overcome increasing water scarcity, better guidance is needed to facilitate cooperative planning and investment in institutionally complex and interconnected water supply systems. This work combines detailed water resource system ensemble modeling with multiobjective intelligent search to explore infrastructure investment partnership design in the context of ongoing canal rehabilitation and groundwater banking in California. Here we demonstrate that severe tradeoffs can emerge between conflicting goals related to water supply deliveries, partnership size, and the underlying financial risks associated with cooperative infrastructure investments. We show how hydroclimatic variability and institutional complexity can create significant uncertainty in realized water supply benefits and heterogeneity in partners’ financial risks that threaten infrastructure investment partnership viability. We demonstrate how multiobjective intelligent search can design partnerships with substantially higher water supply benefits and a fraction of the financial risk compared to status quo planning processes. This work has important implications globally for efforts to use cooperative infrastructure investments to enhance the climate resilience and financial stability of water supply systems.

Science & Technology - Other Topics↗

Feasibility of peak temperature targets in light of institutional constraints

Despite faster-than-expected progress in clean energy technology deployment, global annual CO 2 emissions have increased from 2020 to 2023. The feasibility of limiting warming to 1.5 °C is therefore questioned. Here we present a model intercomparison study that accounts for emissions trends until 2023 and compares cost-effective scenarios to alternative scenarios with institutional, geophysical and technological feasibility constraints and enablers informed by previous literature. Our results show that the most ambitious mitigation trajectories with updated climate information still manage to limit peak warming to below 1.6 °C (‘low overshoot’) with around 50% likelihood. However, feasibility constraints, especially in the institutional dimension, decrease this maximum likelihood considerably to 5–45%. Accelerated energy demand transformation can reduce costs for staying below 2 °C but have only a limited impact on further increasing the likelihood of limiting warming to 1.6 °C. Our study helps to establish a new benchmark of mitigation scenarios that goes beyond the dominant cost-effective scenario design.

54 ENVIRONMENTAL SCIENCES↗

Development of Electrothermal Pulsed Plasma Thrusters for Osaka-Institute-of-Technology Electric-Rocket-Engine onboard Small Space Ship

The Project of Osaka-Institute-of-Technology Electric-Rocket-Engine onboard Small Space Ship (PROITERES) was started at Osaka Institute of Technology. In PROITERES, a 10-kg small satellite with electrothermal pulsed plasma thrusters (PPTs), named JOSHO, will be launched in 2010. The main mission is powered flight of small satellite by electric thruster itself. Electrothermal PPTs were studied with both experiments and numerical simulations. An electrothermal PPT with a side-fed propellant feeding mechanism achieved a total impulse of 3.6 Ns with a repetitive 10000-shot operation. An unsteady numerical simulation showed the existence of considerable amount of ablation delaying to the discharge. However, it was also shown that this phenomenon should not be regarded as the 'late time ablation' for electrothermal PPTs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First operation of the charge-breeder electron-cyclotron-resonance ion source at the Texas A and M Cyclotron Institute

The 14.5 GHz electron-cyclotron-resonance ion source (ECRIS) designed and fabricated specifically for charge breeding has been installed at the Texas A and M University Cyclotron Institute for use in the institute's ongoing radioactive-ion-beam upgrade. The initial testing of the source has just begun with magnetic analysis of the ECRIS beam. The source has only been conditioning for a brief time at low microwave power, and it is continuing to improve. After the source has been conditioned and characterized, charge-breeding trials with stable beams from a singly ionizing source will begin.

43 PARTICLE ACCELERATORS↗

Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The structure of trust as a reflection of culture and institutional power structure: Evidence from four East Asian societies

Using the Global Trust Inventory, an integrated measure of trust toward 21 relationships and institutions, the structure of trust was explored in four East Asian societies (Mainland China, Japan, South Korea, and Taiwan). The Western model, in which trust is distributed among seven factors representing different branches of society, did not generalize to these East Asian societies, perhaps due to differences in culture and institutional power structures. Instead, two unique structures of trust were identified. Mainland China had a top‐down structure of trust (the China model), in which trust is hierarchically separated between the central government and subordinate implementing bodies. The other three democratic East Asian societies shared a hybrid structure of trust (the Democratic East Asian model) that has a degree of similarity to both the China model and the Western model. Having established two similar, but still distinct models, a cross‐cultural comparison was made on the proportions of trust profiles generated by latent profile analysis. Mainland China had the largest proportion of people with a high propensity to trust, followed by Japan and South Korea, and Taiwan was the least trusting. Implications of the structure of trust and this alternative approach to conducting cross‐cultural comparisons are discussed.

Zhang, Robert Jiqi↗

Objective assessment of deformable image registration in radiotherapy: A multi-institution study

The looming potential of deformable alignment tools to play an integral role in adaptive radiotherapy suggests a need for objective assessment of these complex algorithms. Previous studies in this area are based on the ability of alignment to reproduce analytically generated deformations applied to sample image data, or use of contours or bifurcations as ground truth for evaluation of alignment accuracy. In this study, a deformable phantom was embedded with 48 small plastic markers, placed in regions varying from high contrast to roughly uniform regional intensity, and small to large regional discontinuities in movement. CT volumes of this phantom were acquired at different deformation states. After manual localization of marker coordinates, images were edited to remove the markers. The resulting image volumes were sent to five collaborating institutions, each of which has developed previously published deformable alignment tools routinely in use. Alignments were done, and applied to the list of reference coordinates at the inhale state. The transformed coordinates were compared to the actual marker locations at exhale. A total of eight alignment techniques were tested from the six institutions. All algorithms performed generally well, as compared to previous publications. Average errors in predicted location ranged from 1.5 to 3.9 mm, depending on technique. No algorithm was uniformly accurate across all regions of the phantom, with maximum errors ranging from 5.1 to 15.4 mm. Larger errors were seen in regions near significant shape changes, as well as areas with uniform contrast but large local motion discontinuity. Although reasonable accuracy was achieved overall, the variation of error in different regions suggests caution in globally accepting the results from deformable alignment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-19: An Intra-Institutional Study of Cone-Beam CT Dose for Image-Guided Radiation Therapy

Purpose: To determine the variability of Cone-Beam CT Dose Index (CB-CTDI) across multiple on-board imaging (OBI) systems within a single institution, and compare this to manufacturer provided data. Methods: The CB-CTDI was measured on three Trilogy and three TrueBeam Varian OBI systems, for six different clinically used scan protocols. Measurements were taken using a 10 cm long CT ionization chamber in either a 16 cm (head-simulating) or 32 cm (body-simulating) diameter, acrylic, cylindrical, 15 cm long CTDI phantom. We assessed the variation in CB-CTDI between the OBI systems and compared our measured values to the data provided by the manufacturer. Results: The standard error in the CB-CTDI measured for all protocols was found to be within ±2% and ±5% of the mean for TrueBeam and Trilogy, respectively. For all head scan protocols, the measured TrueBeam values were lower than the manufacturer’s reported values, with a maximum difference of 13.9% and an average difference of 11%. For the body scan protocols, the TrueBeam measured values were 3% and 13% greater than the manufacturer’s reported values for two out of three protocols, and 38% lower than reported for the third protocol. In total, 7/18 CB-CTDI measurements fell within the manufacturers specified range (±10%). Across all scans the Truebeam machines were found to have a lower CB-CTDI than Trilogy, particularly the head scan protocols, which show decreases of up to 30% . Conclusion: The intra-institutional variation of CB-CTDI was found to be clinically acceptable at less than 5%. For the TrueBeam OBI system, over half of the measured scans failed to fall with in the manufactured quoted range of 10%, however, all measured values were within 15% of the manufacturer’s reported values. For accurate assessment and reporting of imaging dose to radiotherapy patients, our results indicate a need for standardization in CB-CTDI measurement technique.

60 APPLIED LIFE SCIENCES↗

A multi-institutional study to assess adherence to lung stereotactic body radiotherapy planning goals

Purpose: A multi-institutional planning study was performed to evaluate the frequency that current guidelines established by Radiation Therapy Oncology Group (RTOG) protocols and other literature for lung stereotactic body radiotherapy (SBRT) treatments are followed. Methods: A total of 300 patients receiving lung SBRT treatments in four different institutions were retrospectively reviewed. The treatments were delivered using Linac based SBRT (160 patients) or image guided robotic radiosurgery (140). Most tumors were located peripherally (250/300). Median fractional doses and ranges were 18 Gy (8–20 Gy), 12 Gy (6–15 Gy), and 10 Gy (5–12 Gy) for three, four, and five fraction treatments, respectively. The following planning criteria derived from RTOG trials and the literature were used to evaluate the treatment plans: planning target volumes, PTV{sub V} {sub 100} ≥ 95% and PTV{sub V} {sub 95} ≥ 99%; conformality indices, CI{sub 100%} < 1.2 and CI{sub 50%} range of 2.9–5.9 dependent on PTV; total lung-ITV: V{sub 20Gy} < 10%, V{sub 12.5Gy} < 15%, and V{sub 5Gy} < 37%; contralateral lung V{sub 5Gy} < 26%; and maximum doses for spinal cord, esophagus, trachea/bronchus, and heart and great vessels. Populations were grouped by number of fractions, and dosimetric criteria satisfaction rates (CSRs) were reported. Results: Five fraction regimens were the most common lung SBRT fractionation (46%). The median PTV was 27.2 cm{sup 3} (range: 3.8–419.5 cm{sup 3}). For all plans: mean PTV{sub V} {sub 100} was 94.5% (±5.6%, planning CSR: 69.8%), mean PTV{sub V} {sub 95} was 98.1% (±4.1%, CSR: 69.5%), mean CI{sub 100%} was 1.14 (±0.21, CSR: 79.1%, and 16.5% within minor deviation), and mean CI{sub 50%} was 5.63 (±2.8, CSR: 33.0%, and 28.0% within minor deviation). When comparing plans based on location, peripherally located tumors displayed higher PTV{sub V} {sub 100} and PTV{sub V} {sub 95} CSR (71.5% and 71.9%, respectively) than centrally located tumors (61.2% and 57.1%, respectively). Overall, the planning criteria were met for all the critical structure such as lung, heart, spinal cord, esophagus, and trachea/bronchus for at least 85% of the patients. Conclusions: Among the various parameters that were used to evaluate the SBRT plans, the CI{sub 100%} and CI{sub 50%} were the most challenging criteria to meet. Although the CSRs of organs at risk were higher among all cases, their proximity to the PTV was a significant factor.

60 APPLIED LIFE SCIENCES↗

SU-F-P-35: A Multi-Institutional Plan Quality Checking Tool Built On Oncospace: A Shared Radiation Oncology Database System

Purpose: Late toxicity from radiation to critical structures limits the possible dose in Radiation Therapy. Perfectly conformal treatment of a target is not realizable, so the clinician must accept a certain level of collateral radiation to nearby OARs. But how much? General guidelines exist for healthy tissue sparing which guide RT treatment planning, but are these guidelines good enough to create the optimal plan given the individualized patient anatomy? We propose a means to evaluate the planned dose level to an OAR using a multi-institutional data-store of previously treated patients, so a clinician might reconsider planning objectives. Methods: The tool is built on Oncospace, a federated data-store system, which consists of planning data import, web based analysis tools, and a database containing:1) DVHs: dose by percent volume delivered to each ROI for each patient previously treated and included in the database.2) Overlap Volume Histograms (OVHs): Anatomical measure defined as the percent volume of an ROI within a given distance to target structures.Clinicians know what OARs are important to spare. For any ROI, Oncospace knows for which patients’ anatomy that ROI was harder to plan in the past (the OVH is less). The planned dose should be close to the least dose of previous patients. The tool displays the dose those OARs were subjected to, and the clinician can make a determination about the planning objectives used.Multiple institutions contribute to the Oncospace Consortium, and their DVH and OVH data are combined and color coded in the output. Results: The Oncospace website provides a plan quality display tool which identifies harder to treat patients, and graphically displays the dose delivered to them for comparison with the proposed plan. Conclusion: The Oncospace Consortium manages a data-store of previously treated patients which can be used for quality checking new plans. Grant funding by Elekta.

60 APPLIED LIFE SCIENCES↗

SU-F-J-127: Multi-Institutional Evaluation of Setup, Organ Deformation, Precision Dosimetry in Total Marrow Irradiation

Purpose: Totals Marrow Irradiation (TMI) is a highly focused radiation delivery to the human skeleton structure therefore requiring a high amount of precision and accuracy for a quality treatment. Not much is known on how the patient position varies across multiple treatment fractions and how that positioning impacts the dose delivery. Currently TMI is studied as an international collaboration with multiple centers around the world; however, many of these centers used different pretreatment techniques. The goal of this work is to measure the accuracy of patient positioning, its impact on dose delivery and compare the impact of each technique for multiple institutions. Methods: Using Tomotherapy pretreatment MVCTs and the planning KVCTs measurements are made of the 3D setup uncertainties of the TMI treatment. Then, using the dose and plan files of the treatment impact of patient position on dose can be measured. Measurement of organ deformation and center of mass change were done using the Velocity AI program from Varian. We are looking at four the boney targets (skull, spine, pelvis, and femur) and three key sensitive tissues (eyes, lungs, kidneys). Results: Position measurements have been made for 3 different institutions using 3 different pre-treatment techniques. Comparing the translation motion we can observe the greatest change in the Y and Z direction of patient set up. For intra-fractional motion the shoulder and clavicle represent the greatest potential for motion and therefore most likely to have a dose change. Conclusion: All centers use different techniques for their treatment and this study shows that these techniques do not produce the same pretreatment results. We hope to expand this study further. Currently we have 3 centers participating in this study with more centers joining every day.

60 APPLIED LIFE SCIENCES↗

AmeriFlux US-xSC NEON Smithsonian Conservation Biology Institute (SCBI)

This is the AmeriFlux version of the carbon flux data for the site US-xSC NEON Smithsonian Conservation Biology Institute (SCBI). Site Description - The Smithsonian Conservation Biology Institute (SCBI) site is a mid-continent forested eastern deciduous site, species include Oaks, Hickories, and Ash, and contains well defined ground cover and understory strata.

Network), NEON (National Ecological Observatory↗

AmeriFlux FLUXNET-1F US-KLS Kansas Land Institute

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-KLS Kansas Land Institute. This is the FLUXNET version of the carbon flux data for the site US-KLS Kansas Land Institute produced by applying the standard ONEFlux (1F) software. Site Description - Perenniel Agricultural site

Brunsell, Nathaniel↗

The Institute of Geophysics and Planetary Physics adds Science of Signatures and a new Deputy to its portfolio

The Institute of Geophysics and Planetary Physics (IGPP) is adding the Science of Signatures to it’s portfolio. It’s new title, the Institute of Geophysics, Planetary Physics and Signatures (IGPPS) is in recognition that Science of Signatures is a LANL strategic science pillar, and is a natural fit with the IGPPS goal of promoting and supporting high quality, cutting-edge science in the areas of astrophysics, space physics, solid planetary geoscience, and climate science. IGPPS Director Dogliani states that, “One cannot fully understand natural phenomena without conducting field measurements of key events.” Beginning in FY13, IGPPS will consider proposals that investigate and develop signature and sensor science for potential use in understanding our evolving climate, geoscience, planetary space and cosmology phenomena.

99 GENERAL AND MISCELLANEOUS↗

Low Enriched Uranium Core Design for the Massachusetts Institute of Technology Reactor (MITR) with Un-finned 12 mil-thick Clad UMo Monolithic Fuel

This report contains the results of reactor fuel element design for conversion of the Massachusetts Institute of Technology Reactor (MITR) from the use of highly enriched uranium (HEU) fuel to the use of low enriched uranium (LEU) fuel. The analyses were performed by staff members of the Global Threat Reduction Initiative (GTRI) Reactor Conversion Program at the Argonne National Laboratory (ANL) and the Massachusetts Institute of Technology Nuclear Reactor Laboratory. The core conversion to LEU is being performed with financial support of the U.S. government.

Bergeron, A.↗