Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image reconstruction techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

MemXCT: Design, Optimization, Scaling, and Reproducibility of X-Ray Tomography Imaging

Here, this work extends our previous research entitled "MemXCT: Memory-centric X-ray CT Reconstruction with Massive Parallelization" that was originally published at SC19 conference (Hidayetoglu et al., 2019) with reproducibility of the computational imaging performance. X-ray computed tomography (XCT) is regularly used at synchrotron light sources to study the internal morphology of materials at high resolution. However, experimental constraints, such as radiation sensitivity, can result in noisy or undersampled measurements. Further, depending on the resolution, sample size and data acquisition rates, the resulting noisy dataset can be in the order of terabytes. Advanced iterative reconstruction techniques can produce high-quality images from noisy measurements, but their computational requirements have made their use an exception rather than the rule. We propose a novel memory-centric approach that avoids redundant computations at the expense of additional memory complexity. We develop a memory-centric iterative reconstruction system, MemXCT, that uses an optimized SpMV implementation with two-level pseudo-Hilbert ordering and multi-stage input buffering. We evaluate MemXCT on various supercomputer architectures involving KNL and GPU. MemXCT can reconstruct a large (11Kx11K) mouse brain tomogram in 10 seconds using 4096 KNL nodes (256K cores). The results presented in our original article at the SC19 were based on large-scale supercomputing resources. The MemXCT application was selected for the Student Cluster Competition (SCC) Reproducibility Challenge and evaluated on a variety of cloud computing resources by universities around the world in the SC20 conference. We summarize the results of the top-ranked SCC Reproducibility Challenge teams and identify the most pertinent measures for ensuring the reproducibility of our experiments in this article.

47 OTHER INSTRUMENTATION↗

The Pixon Method for Data Compression Image Classification, and Image Reconstruction

As initially proposed, this program had three goals: (1) continue to develop the highly successful Pixon method for image reconstruction and support other scientist in implementing this technique for their applications; (2) develop image compression techniques based on the Pixon method; and (3) develop artificial intelligence algorithms for image classification based on the Pixon approach for simplifying neural networks. Subsequent to proposal review the scope of the program was greatly reduced and it was decided to investigate the ability of the Pixon method to provide superior restorations of images compressed with standard image compression schemes, specifically JPEG-compressed images.

Puetter, Richard↗

Controlling electron-ion rescattering in two-color circularly polarized femtosecond laser fields

High-harmonic generation driven by two-color counter-rotating circularly polarized laser fields was recently demonstrated experimentally as a breakthrough source of bright, coherent, circularly polarized beams in the extreme ultraviolet and soft-x-ray regions. However, the conditions for optimizing the single-atom yield are significantly more complex than for linearly polarized driving lasers and are not fully understood. In this study we present a comprehensive study of strong-field ionization—the complementary process to high-harmonic generation—driven by two-color circularly polarized fields. We uncover the conditions that lead to enhanced electron-ion rescattering, which should correspond to the highest single-atom harmonic flux. Using a velocity map imaging photoelectron spectrometer and tomographic reconstruction techniques, we record three-dimensional photoelectron distributions resulting from the strong-field ionization of argon atoms across a broad range of driving laser intensity ratios. In combination with analytical predictions and advanced numerical simulations, we show that “hard” electron-ion rescattering is optimized when the second-harmonic field has an intensity approximately four times higher than that of the fundamental driving field. We also investigate electron-ion rescattering with co-rotating fields, and find that rescattering is significantly suppressed when compared with counter-rotating fields.

74 ATOMIC AND MOLECULAR PHYSICS↗

Scalable measurements of tow architecture variability in braided ceramic composite tubes

Abstract The performance of braided ceramic matrix composites has been shown to depend on the spatial arrangement of tows; therefore, a new class of tools is required to measure irregularities in the composite architecture for components with intricate geometries. We report a scalable and robust reconstruction technique built upon stereoscopic digital image correlation that is able to efficiently measure the position of tows in arbitrarily shaped composites. This method was applied to triaxially braided ceramic matrix composite tubes intended for use as nuclear fuel cladding, which revealed both long‐range “systematic” tow packing defects associated with the manufacturing process and short‐range “intrinsic” defects due to the braid architecture. These findings suggested that the character of tow spacing variation in braided composite tubes was substantially more complex than in planar woven composites. These measurements are expected to lead to improved processing of braided composites and to facilitate the design of statistically representative virtual specimens for finite element modeling.

Heim, Frederick M.↗

Reference-free ground truth metric for metal artifact evaluation in CT images

Purpose: In computed tomography (CT), metal objects in the region of interest introduce data inconsistencies during acquisition. Reconstructing these data results in an image with star shaped artifacts induced by the metal inconsistencies. To enhance image quality, the influence of the metal objects can be reduced by different metal artifact reduction (MAR) strategies. For an adequate evaluation of new MAR approaches a ground truth reference data set is needed. In technical evaluations, where phantoms can be measured with and without metal inserts, ground truth data can easily be obtained by a second reference data acquisition. Obviously, this is not possible for clinical data. Here, an alternative evaluation method is presented without the need of an additionally acquired reference data set. Methods: The proposed metric is based on an inherent ground truth for metal artifacts as well as MAR methods comparison, where no reference information in terms of a second acquisition is needed. The method is based on the forward projection of a reconstructed image, which is compared to the actually measured projection data. Results: The new evaluation technique is performed on phantom and on clinical CT data with and without MAR. The metric results are then compared with methods using a reference data set as well as an expert-based classification. It is shown that the new approach is an adequate quantification technique for artifact strength in reconstructed metal or MAR CT images. Conclusions: The presented method works solely on the original projection data itself, which yields some advantages compared to distance measures in image domain using two data sets. Beside this, no parameters have to be manually chosen. The new metric is a useful evaluation alternative when no reference data are available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification and visualization of uncertainties in reconstructed penumbral images of implosions at Omega

Penumbral imaging is a technique used in plasma diagnostics in which a radiation source shines through one or more large apertures onto a detector. To interpret a penumbral image, one must reconstruct it to recover the original source. The inferred source always has some error due to noise in the image and uncertainty in the instrument geometry. Interpreting the inferred source thus requires quantification of that inference’s uncertainty. Markov chain Monte Carlo algorithms have been used to quantify uncertainty for similar problems but have never been used for the inference of the shape of an image. Because of this, there are no commonly accepted ways of visualizing uncertainty in two-dimensional data. This paper demonstrates the application of the Hamiltonian Monte Carlo algorithm to the reconstruction of penumbral images of fusion implosions and presents ways to visualize the uncertainty in the reconstructed source. This methodology enables more rigorous analysis of penumbral images than has been done in the past.

Instruments & Instrumentation↗

SU-E-J-246: A Deformation-Field Map Based Liver 4D CBCT Reconstruction Method Using Gold Nanoparticles as Constraints

Purpose: To investigate the feasibility of using nanoparticle markers to validate liver tumor motion together with a deformation field map-based four dimensional (4D) cone-beam computed tomography (CBCT) reconstruction method. Methods: A technique for lung 4D-CBCT reconstruction has been previously developed using a deformation field map (DFM)-based strategy. In this method, each phase of the 4D-CBCT is considered as a deformation of a prior CT volume. The DFM is solved by a motion modeling and free-form deformation (MM-FD) technique, using a data fidelity constraint and the deformation energy minimization. For liver imaging, there is low contrast of a liver tumor in on-board projections. A validation of liver tumor motion using implanted gold nanoparticles, along with the MM-FD deformation technique is implemented to reconstruct onboard 4D CBCT liver radiotherapy images. These nanoparticles were placed around the liver tumor to reflect the tumor positions in both CT simulation and on-board image acquisition. When reconstructing each phase of the 4D-CBCT, the migrations of the gold nanoparticles act as a constraint to regularize the deformation field, along with the data fidelity and the energy minimization constraints. In this study, multiple tumor diameters and positions were simulated within the liver for on-board 4D-CBCT imaging. The on-board 4D-CBCT reconstructed by the proposed method was compared with the “ground truth” image. Results: The preliminary data, which uses reconstruction for lung radiotherapy suggests that the advanced reconstruction algorithm including the gold nanoparticle constraint will Resultin volume percentage differences (VPD) between lesions in reconstructed images by MM-FD and “ground truth” on-board images of 11.5% (± 9.4%) and a center of mass shift of 1.3 mm (± 1.3 mm) for liver radiotherapy. Conclusion: The advanced MM-FD technique enforcing the additional constraints from gold nanoparticles, results in improved accuracy for reconstructing on-board 4D-CBCT of liver tumor. Varian medical systems research grant.

60 APPLIED LIFE SCIENCES↗

Wiener filtering of successive overlapping sections of an X-ray reconstruction

In this paper, a technique is developed to improve the image quality of an object in three-dimensional reconstruction by a weighted average of successive overlapping two-dimensional sections of the object. It is demonstrated that the signal-to-noise ratio of a two-dimensional picture can be improved by roughly a factor of 2 for typical X-ray beam shapes.

Reed, I. S.↗

Super-resolution reconstruction for 4D computed tomography of the lung via the projections onto convex sets approach

Purpose: The use of 4D computed tomography (4D-CT) of the lung is important in lung cancer radiotherapy for tumor localization and treatment planning. Sometimes, dense sampling is not acquired along the superior–inferior direction. This disadvantage results in an interslice thickness that is much greater than in-plane voxel resolutions. Isotropic resolution is necessary for multiplanar display, but the commonly used interpolation operation blurs images. This paper presents a super-resolution (SR) reconstruction method to enhance 4D-CT resolution. Methods: The authors assume that the low-resolution images of different phases at the same position can be regarded as input “frames” to reconstruct high-resolution images. The SR technique is used to recover high-resolution images. Specifically, the Demons deformable registration algorithm is used to estimate the motion field between different “frames.” Then, the projection onto convex sets approach is implemented to reconstruct high-resolution lung images. Results: The performance of the SR algorithm is evaluated using both simulated and real datasets. Their method can generate clearer lung images and enhance image structure compared with cubic spline interpolation and back projection (BP) method. Quantitative analysis shows that the proposed algorithm decreases the root mean square error by 40.8% relative to cubic spline interpolation and 10.2% versus BP. Conclusions: A new algorithm has been developed to improve the resolution of 4D-CT. The algorithm outperforms the cubic spline interpolation and BP approaches by producing images with markedly improved structural clarity and greatly reduced artifacts.

60 APPLIED LIFE SCIENCES↗

Importance of point-by-point back projection correction for isocentric motion in digital breast tomosynthesis: Relevance to morphology of structures such as microcalcifications

Digital breast tomosynthesis is a three-dimensional imaging technique that provides an arbitrary set of reconstruction planes in the breast from a limited-angle series of projection images acquired while the x-ray tube moves. Traditional shift-and-add (SAA) tomosynthesis reconstruction is a common mathematical method to line up each projection image based on its shifting amount to generate reconstruction slices. With parallel-path geometry of tube motion, the path of the tube lies in a plane parallel to the plane of the detector. The traditional SAA algorithm gives shift amounts for each projection image calculated only along the direction of x-ray tube movement. However, with the partial isocentric motion of the x-ray tube in breast tomosynthesis, small objects such as microcalcifications appear blurred (for instance, about 1-4 pixels in blur for a microcalcification in a human breast) in traditional SAA images in the direction perpendicular to the direction of tube motion. Some digital breast tomosynthesis algorithms reported in the literature utilize a traditional one-dimensional SAA method that is not wholly suitable for isocentric motion. In this paper, a point-by-point back projection (BP) method is described and compared with traditional SAA for the important clinical task of evaluating morphology of small objects such as microcalcifications. Impulse responses at different three-dimensional locations with five different combinations of imaging acquisition parameters were investigated. Reconstruction images of microcalcifications in a human subject were also evaluated. Results showed that with traditional SAA and 45 deg. view angle of tube movement with respect to the detector, at the same height above the detector, the in-plane blur artifacts were obvious for objects farther away from x-ray source. In a human subject, the appearance of calcifications was blurred in the direction orthogonal to the tube motion with traditional SAA. With point-by-point BP, the appearance of calcifications was sharper. The point-by-point BP method demonstrated improved rendition of microcalcifications in the direction perpendicular to the tube motion direction. With wide angles or for imaging of larger breasts, this point-by-point BP rather than the traditional SAA should also be considered as the basis of further deblurring algorithms that work in conjunction with the BP method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neutrino event selection in the MicroBooNE liquid argon time projection chamber using Wire-Cell 3D imaging, clustering, and charge-light matching

An accurate and efficient event reconstruction is required to realize the full scientific capability of liquid argon time projection chambers (LArTPCs). The current and future neutrino experiments that rely on massive LArTPCs create a need for new ideas and reconstruction approaches. Wire-Cell, proposed in recent years, is a novel tomographic event reconstruction method for LArTPCs. The Wire-Cell 3D imaging approach capitalizes on charge, sparsity, time, and geometry information to reconstruct a topology-agnostic 3D image of the ionization electrons prior to pattern recognition. A second novel method, the many-to-many charge-light matching, then pairs the TPC charge activity to the detected scintillation light signal, thus enabling a powerful rejection of cosmic-ray muons in the MicroBooNE detector. A robust processing of the scintillation light signal and an appropriate clustering of the reconstructed 3D image are fundamental to this technique. In this paper, we describe the principles and algorithms of these techniques and their successful application in the MicroBooNE experiment. A quantitative evaluation of the performance of these techniques is presented. Using these techniques, a 95% efficient pre-selection of neutrino charged-current events is achieved with a 30-fold reduction of non-beam-coincident cosmic-ray muons, and about 80% of the selected neutrino charged-current events are reconstructed with at least 70% completeness and 80% purity.

3D imaging↗

SU-E-I-73: Clinical Evaluation of CT Image Reconstructed Using Interior Tomography

Purpose: Radiation dose reduction has been a long standing challenge in CT imaging of obese patients. Recent advances in interior tomography (reconstruction of an interior region of interest (ROI) from line integrals associated with only paths through the ROI) promise to achieve significant radiation dose reduction without compromising image quality. This study is to investigate the application of this technique in CT imaging through evaluating imaging quality reconstructed from patient data. Methods: Projection data were directly obtained from patients who had CT examinations in a Dual Source CT scanner (DSCT). Two detectors in a DSCT acquired projection data simultaneously. One detector provided projection data for full field of view (FOV, 50 cm) while another detectors provided truncated projection data for a FOV of 26 cm. Full FOV CT images were reconstructed using both filtered back projection and iterative algorithm; while interior tomography algorithm was implemented to reconstruct ROI images. For comparison reason, FBP was also used to reconstruct ROI images. Reconstructed CT images were evaluated by radiologists and compared with images from CT scanner. Results: The results show that the reconstructed ROI image was in excellent agreement with the truth inside the ROI, obtained from images from CT scanner, and the detailed features in the ROI were quantitatively accurate. Radiologists evaluation shows that CT images reconstructed with interior tomography met diagnosis requirements. Radiation dose may be reduced up to 50% using interior tomography, depending on patient size. Conclusion: This study shows that interior tomography can be readily employed in CT imaging for radiation dose reduction. It may be especially useful in imaging obese patients, whose subcutaneous tissue is less clinically relevant but may significantly increase radiation dose.

60 APPLIED LIFE SCIENCES↗

35-45 Giga Hertz Transceiver System for Phase and Magnitude Detection

Nondestructive evaluation (NDE) is the science and practice of examining an object in a way that the object's usefulness is not adversely affected. Different types of NDE methods exist but this thesis is based on microwave and millimeter wave NDE using imaging techniques. Microwave NDE is based on illuminating the object under test with a microwave signal and studying the various properties of the reflected signal from the object. This reflected signal contains some information about the inner structure of the object under test. This information may be contained in several parameters including the phase and magnitude of the reflected signal. The goal of this project is to design and build a Q-band coherent transceiver that is capable of measuring the reflected signal's phase and magnitude so that an image of the object under test may be reconstructed. From the several techniques that can be used to construct an image of the object under test, techniques of interest to this work include synthetic aperture focusing technique (SAFT) and microwave holography. The transceiver system should have the ability to sweep a large portion of Q-band frequency range in small frequency steps as quick as possible while the detected phase and magnitude of the reflected signal is very accurate. Several different designs were studied and the final schematic diagram of the transceiver system was determined. One of the most important modules that was designed, implemented and tested in the laboratory was an accurate phase/magnitude detector circuit. The compared results of the scans using the transceiver system and vector network analyzer (VNA) showed that this transceiver system has a great potential to replace a VNA for the purpose of microwave and millimeter wave imaging.

Beni, Aman Aflaki↗

Progress towards the development and testing of source reconstruction methods for neutron imaging of ICF implosions

Development of analysis techniques for neutron imaging at the National Ignition Facility (NIF) is an important and difficult task for the detailed understanding or high neutron yield inertial confinement fusion (ICF) implosions. These methods, once developed, must provide accurate images of the hot and cold fuel so that information about the implosion, such as symmetry and areal density, can be extracted. We are currently considering multiple analysis pathways for obtaining this source distribution of neutrons given a measured pinhole image with a scintillator and camera system. One method under development involves the numerical inversion of the pinhole image using knowledge of neutron transport through the pinhole aperture from Monte Carlo simulations [E. Loomis et al. IFSA 2009]. We are currently striving to apply the technique to real data by applying a series of realistic effects that will be present for experimental images. These include various sources of noise, misalignment uncertainties at both the source and image planes, as well as scintillator and camera blurring. Some tests on the quality of image reconstructions have also been performed based on point resolution and Legendre mode improvement of recorded images. So far, the method has proven sufficient to overcome most of these experimental effects with continued devlopment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simultaneous reduction of radiation dose and scatter for CBCT by using collimators

Purpose: On-board cone-beam CT (CBCT) imaging has been widely available in radiotherapy clinic for target localization. However, the extra radiation dose from CBCT is always a concern for its frequent use. Additionally, the relatively large scatter in CBCT often degrades the image quality. By using collimators, some of the X-rays can be stopped from reaching the patient and the detectors, hence both the scatter and the patient doses are simultaneously reduced. The authors show in this work that the collimated CBCT data can be reconstructed without any noticeable artifacts for certain collimator blocking ratios and blocking patterns, and the focus of this work is to study the relationship between the image quality and these two collimator factors.Methods: A CBCT system with collimators was simulated following the typical geometry used in clinic. Different collimator designs were tested by varying the size and the number of the collimator slits, and at the same time, the ratio of transmitted beams to total beams was varied from 100% to 10%, resulting in hundreds of different simulation scenarios. Lung and pelvis phantoms created from patients CT images were used in the simulations, and an iterative reconstruction algorithm using the compressed sensing technique was adopted. The image quality was examined by root mean square errors (RMSEs) and compared with the conventional CBCT images.Results: The CBCT image quality increases as the amount of beams passing through the collimators increases, and decreases as the size of the collimator slits increases. With ultra-high resolution collimators, the RMSEs were comparable to the conventional CBCT image quality until the beam transmission rate is reduced below 25%.Conclusions: Collimators can reduce the scatters and radiation dose, however, the collimated CBCT image quality is strongly dependent on both the collimator blocking ratio and the blocking pattern. To achieve image quality comparable to the conventional CBCT, the amount of information and data format must be adequate.

61 RADIATION PROTECTION AND DOSIMETRY↗

Clinical Implementation of Intrafraction Cone Beam Computed Tomography Imaging During Lung Tumor Stereotactic Ablative Radiation Therapy

Purpose: To develop and clinically evaluate a volumetric imaging technique for assessing intrafraction geometric and dosimetric accuracy of stereotactic ablative radiation therapy (SABR). Methods and Materials: Twenty patients received SABR for lung tumors using volumetric modulated arc therapy (VMAT). At the beginning of each fraction, pretreatment cone beam computed tomography (CBCT) was used to align the soft-tissue tumor position with that in the planning CT. Concurrent with dose delivery, we acquired fluoroscopic radiograph projections during VMAT using the Varian on-board imaging system. Those kilovolt projections acquired during millivolt beam-on were automatically extracted, and intrafraction CBCT images were reconstructed using the filtered backprojection technique. We determined the time-averaged target shift during VMAT by calculating the center of mass of the tumor target in the intrafraction CBCT relative to the planning CT. To estimate the dosimetric impact of the target shift during treatment, we recalculated the dose to the GTV after shifting the entire patient anatomy according to the time-averaged target shift determined earlier. Results: The mean target shift from intrafraction CBCT to planning CT was 1.6, 1.0, and 1.5 mm; the 95th percentile shift was 5.2, 3.1, 3.6 mm; and the maximum shift was 5.7, 3.6, and 4.9 mm along the anterior-posterior, left-right, and superior-inferior directions. Thus, the time-averaged intrafraction gross tumor volume (GTV) position was always within the planning target volume. We observed some degree of target blurring in the intrafraction CBCT, indicating imperfect breath-hold reproducibility or residual motion of the GTV during treatment. By our estimated dose recalculation, the GTV was consistently covered by the prescription dose (PD), that is, V100% above 0.97 for all patients, and minimum dose to GTV >100% PD for 18 patients and >95% PD for all patients. Conclusions: Intrafraction CBCT during VMAT can provide geometric and dosimetric verification of SABR valuable for quality assurance and potentially for treatment adaptation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Super-resolution reconstruction in frequency, image, and wavelet domains to reduce through-plane partial voluming in MRI

Purpose: To compare and evaluate the use of super-resolution reconstruction (SRR), in frequency, image, and wavelet domains, to reduce through-plane partial voluming effects in magnetic resonance imaging. Methods: The reconstruction of an isotropic high-resolution image from multiple thick-slice scans has been investigated through techniques in frequency, image, and wavelet domains. Experiments were carried out with thick-slice T2-weighted fast spin echo sequence on the Academic College of Radiology MRI phantom, where the reconstructed images were compared to a reference high-resolution scan using peak signal-to-noise ratio (PSNR), structural similarity image metric (SSIM), mutual information (MI), and the mean absolute error (MAE) of image intensity profiles. The application of super-resolution reconstruction was then examined in retrospective processing of clinical neuroimages of ten pediatric patients with tuberous sclerosis complex (TSC) to reduce through-plane partial voluming for improved 3D delineation and visualization of thin radial bands of white matter abnormalities. Results: Quantitative evaluation results show improvements in all evaluation metrics through super-resolution reconstruction in the frequency, image, and wavelet domains, with the highest values obtained from SRR in the image domain. The metric values for image-domain SRR versus the original axial, coronal, and sagittal images were PSNR = 32.26 vs 32.22, 32.16, 30.65; SSIM = 0.931 vs 0.922, 0.924, 0.918; MI = 0.871 vs 0.842, 0.844, 0.831; and MAE = 5.38 vs 7.34, 7.06, 6.19. All similarity metrics showed high correlations with expert ranking of image resolution with MI showing the highest correlation at 0.943. Qualitative assessment of the neuroimages of ten TSC patients through in-plane and out-of-plane visualization of structures showed the extent of partial voluming effect in a real clinical scenario and its reduction using SRR. Blinded expert evaluation of image resolution in resampled out-of-plane views consistently showed the superiority of SRR compared to original axial and coronal image acquisitions. Conclusions: Thick-slice 2D T2-weighted MRI scans are part of many routine clinical protocols due to their high signal-to-noise ratio, but are often severely affected by through-plane partial voluming effects. This study shows that while radiologic assessment is performed in 2D on thick-slice scans, super-resolution MRI reconstruction techniques can be used to fuse those scans to generate a high-resolution image with reduced partial voluming for improved postacquisition processing. Qualitative and quantitative evaluation showed the efficacy of all SRR techniques with the best results obtained from SRR in the image domain. The limitations of SRR techniques are uncertainties in modeling the slice profile, density compensation, quantization in resampling, and uncompensated motion between scans.

60 APPLIED LIFE SCIENCES↗

A new nonlinear reconstruction method based on total variation regularization of neutron penumbral imaging

Neutron penumbral imaging is a significant diagnostic technique in laser-driven inertial confinement fusion experiment. It is very important to develop a new reconstruction method to improve the resolution of neutron penumbral imaging. A new nonlinear reconstruction method based on total variation (TV) regularization is proposed in this paper. A TV-norm is used as regularized term to construct a smoothing functional for penumbral image reconstruction in the new method, in this way, the problem of penumbral image reconstruction is transformed to the problem of a functional minimization. In addition, a fixed point iteration scheme is introduced to solve the problem of functional minimization. The numerical experimental results show that, compared to linear reconstruction method based on Wiener filter, the TV regularized nonlinear reconstruction method is beneficial to improve the quality of reconstructed image with better performance of noise smoothing and edge preserving. Meanwhile, it can also obtain the spatial resolution with 5 {mu}m which is higher than the Wiener method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗