Remote Fiber Based Velocimeter For Interface Strength Measurements

The understanding of the performance of nuclear reactor plate fuels is essential when developing new fuel systems. The condition of pre and post irradiated plate fuels must be characterized effectively and efficiently prior to irradiation and then post irradiation within a high rad environment. The post characterization work must be performed remotely and in an environment hostile to instrumentation. Laser based characterization methods provide the capability to be remote and robust within a hot-cell environment. Laser based characterization can provide high spatial resolution appropriate for scanning and imaging large areas. The INL is currently developing a laser shock system for Post Irradiation Examination (PIE) station for use in the Hot Fuel Examination Facility (HFEF) at the INL. The laser shock system is designed to characterize fuel to cladding and cladding to cladding interface strength. The laser shock-technique induces large amplitude shock waves to mechanically characterize interfaces such as the fuel-clad interface. The shock wave propagates as a compressional wave through the fuel plate to the free (unconfined) backside surface and is reflected back through the test plate as a rarefaction (tensile) wave. This rarefaction wave is the physical mechanism that produces internal delamination failure. The focus or this paper is on the accurate measurement of surface velocity to quantify the amount of energy traveling through the interfaces to the back surface of the fuel plate. The original fiber based velocimeter design was biased by parasitic back reflections. This paper will discuss the discovery of the back-reflection issue and the design changes to resolve the issue. Supporting data will be presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

On the nature of apparent transient sources on the National Geographic Society–Palomar Observatory Sky Survey glass copy plates

Abstract We examine critically recent claims for the presence of above-atmosphere optical transients in publicly available digitized scans of Schmidt telescope photographic plate material derived from the National Geographic Society–Palomar Observatory Sky Survey. We employ the publicly available SuperCOSMOS Sky Survey catalogues to examine statistically the morphology of the sources. We develop a simple, objective, and automated image classification scheme based on a random forest decision tree classifier. We find that the putative transients are likely to be spurious artefacts of the photographic emulsion. We suggest a possible cause of the appearance of these images as resulting from the copying procedure employed to disseminate glass copy survey atlas sets in the era before large-scale digitization programmes.

Hambly, N. C. (ORCID:0000000299019064)↗

High-Speed OH-PLIF Diagnostics of Flame Flashback in Low Swirl Hydrogen-Enriched Flames

This paper reports flashback events observed in hydrogen-enriched flames stabilized in a low swirl burner (LSB) at atmospheric pressure and temperature conditions. The fundamentals of hydrogen-rich stable flames and spatiotemporal investigation of flashback phenomena were observed experimentally using a high-repetition-rate nanosecond (ns)-duration hydroxyl radical planar laser-induced fluorescence (OH-PLIF) diagnostic. Testing was conducted in an optically accessible pre-mixing section of a LSB with inlet pre-mixing velocities ranging from 5 to 10 m/s for methane and hydrogen (50 – 90% by mole) blends. Swirlers with two different turning angles, 26o and 33o, and three different perforated plate hole diameters, 1.08, 1.12 and 1.16 mm, with measured swirl numbers varying from 0.43 to 0.49 were used in this study at atmospheric temperature and pressure inlet conditions. The flashback propensity showed a dependence on the proximity of the lifted flame to the burner exit (termed as lift-off length, L) which was dependent on the pre-mixer velocity (V), hydrogen content (XH2) and equivalence ratio (ϕ) at constant temperature and pressure conditions. High-speed OH-PLIF images revealed lifted flames were first observed at low ϕ/ XH2 condition which then changed to a M-shaped flame attached to burner rim with the increase in ϕ/ XH2. Further increases in ϕ/XH2, depending upon other inlet parameters, triggered flame flashback into the pre-mixing section. Flashback occurred when burning began in the outer shear layer and the leading flame brush propagated into the nozzle. Such spatiotemporally resolved high-speed OH-PLIF imaging provides insights on different stages of flashback in a LSB – flashback initiation, transition of flame propagation from burner exit to the swirler and flashback to flame holding transition. Flame ϕ at flashback showed an expected linearly increasing trend with increasing V and decreasing XH2 and the conclusions drawn aligned well with detailed investigations. For identical inlet conditions, flashback propensity decreased with increasing perforated-plate hole diameter and increasing swirler vane angle.

Parajuli, Pradeep↗

Freestanding high-aspect-ratio gold masks for low-energy, phase-based x-ray microscopy

High-resolution, x-ray phase contrast microscopy, a key technique with promising potential in biomedical imaging and diagnostics, is based on narrow-slit high-aspect-ratio gold gratings. Here we present the development, fabrication details, and experimental testing of the freestanding 10 μm thick gold membrane masks with an array of 0.9–1.5 μm void slit apertures for a novel low-energy x-ray microscope. The overall mask size is 4 mm × 4 mm, with a grating pitch of 7.5 μm, 6.0–6.6 μm wide gold bars are supported by 3 μm wide crosslinks at 400 μm intervals. The fabrication process is based on gold electroplating into a silicon mold coated with various thin films to form a voltage barrier, plating base, and sacrificial layer, followed by the mold removal to obtain the freestanding gold membrane with void slit apertures. We discuss key aspects for the materials and processes, including gold structures homogeneity, residual stresses, and prevention of collapsing of the grid elements. We further demonstrate the possibility to obtain high-resolution, high contrast 2D images of biological samples using an incoherent, rotating anode x-ray tube.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ultrafast Metal Electrodeposition Revealed by In Situ Optical Imaging and Theoretical Modeling towards Fast–Charging Zn Battery Chemistry

Metallic Zn is a preferred anode material for rechargeable aqueous batteries towards a smart grid and renewable energy storage. Importantly, understanding how the metal nucleates and grows at the aqueous Zn anode is a critical and challenging step to achieve full reversibility of Zn battery chemistry, especially under fast-charging conditions. Here, by combining in situ optical imaging and theoretical modeling, we uncover the critical parameters governing the electrodeposition stability of the metallic Zn electrode, that is, the competition among crystallographic thermodynamics, kinetics, and Zn 2+ -ion diffusion. Moreover, steady-state Zn metal plating/ stripping with Coulombic efficiency above 99 % is achieved at 10-100 mA cm -2 in a reasonably high concentration (3 M) ZnSO 4 electrolyte. Significantly, a long-term cycling-stable Zn metal electrode is realized with a depth of discharge of 66.7% under 50 mA cm -2 in both Zn || Zn symmetrical cells and MnO 2 || Zn full cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compact high repetition rate Thomson parabola ion spectrometer

Here, we present the development of a compact Thomson parabola ion spectrometer capable of characterizing the energy spectra of various ion species of multi-MeV ion beams from >10 20 W/cm 2 laser produced plasmas at rates commensurate with the highest available from any of the current and near-future PW-class laser facilities. This diagnostic makes use of a polyvinyl toluene based fast plastic scintillator (EJ-260), and the emitted light is collected using an optical imaging system coupled to a thermoelectrically cooled scientific complementary metal–oxide–semiconductor camera. This offers a robust solution for data acquisition at a high repetition rate, while avoiding the added complications and nonlinearities of micro-channel plate based systems. Different ion energy ranges can be probed using a modular magnet setup, a variable electric field, and a varying drift-distance. We have demonstrated operation and data collection with this system at up to 0.2 Hz from plasmas created by irradiating a solid target, limited only by the targeting system. With the appropriate software, on-the-fly ion spectral analysis will be possible, enabling real-time experimental control at multi-Hz repetition rates.

47 OTHER INSTRUMENTATION↗

Analysis of the laser welding keyhole using inline coherent imaging

Laser beam welding is a widely used fusion welding process in many industrial applications such as automotive, aerospace, energy, defense, and medical products. Industry has a fundamental need to model the laser welding process to minimize experimental testing and improve confidence in production welds. However, computational models attempting to predict weld formation are limited by an incomplete understanding of the beam-material interactions. As a consequence, these models do not accurately predict the mechanisms associated with laser weld formation. To improve the current state of prediction capabilities, it is vital to better detect/measure the physical aspects of the weld pool during high energy density welding. In this work, a novel real-time laser weld monitoring device using inline coherent imaging (ICI) was used to provide a fundamental understanding of laser weld formation via vaporization. The objective of this work was to investigate and quantify the relationship relating laser weld parameters and the vapor capillary (keyhole) through a state-of-the-art measurement technique. Bead-on-plate laser beam welds were produced with partial penetration on 304L stainless steel, 2205 duplex stainless steel, and Ti-6Al-4V. Keyhole monitoring was performed using a commercially available ICI system to collect keyhole penetration data in real time. These measurements were reconstructed to generate the vapor capillary shape at different welding parameters. Process parameters significantly influenced the keyhole shape and the keyhole root position relative to the process beam. Finally, the keyhole geometry showed distinct differences between the stainless steel alloys and Ti-6Al-4V.

2205↗

Development of a synthetic phase contrast imaging diagnostic for turbulence studies at Wendelstein 7-X

Abstract We present a synthetic phase contrast imaging (PCI) diagnostic for studying turbulence at the Wendelstein 7-X (W7-X) stellarator. We first describe the implemented instrument response model, which captures diffraction effects, detector noise, and the long-wavelength cutoff due to the phase plate of the PCI system. To verify the instrument response model, we show that it is capable of reproducing the PCI signal generated by the sound wave speaker used for calibration at W7-X. Next, we discuss the calculation of synthetic PCI signals based on the global, nonlinear gyrokinetic codes GENE-3D and EUTERPE, including results from some of the first stellarator simulations of this type with kinetic electrons (KEs) in GENE-3D. While the simulations used in this work lack a neoclassical radial electric field, which is crucial for reproducing experimental PCI signals, they do indicate that the dominant rotation direction and velocities of the turbulent fluctuations can be inferred from the wave number-frequency spectra of the PCI signals, as expected. The synthetic PCI wave number spectra are further shown to be similar to those of the line-integrated fluctuating electron density, with distinct differences between adiabatic and KE simulations, explainable by previously published turbulence models. For example, the wave number spectra of all adiabatic electron simulations analyzed here follow a power law with an exponent close to −5 for sufficiently large wave numbers. This indicates that universal features of electron density turbulence at W7-X may be studied using the PCI system.

EUTERPE↗

Oxide-nitride heteroepitaxy for low-loss dielectrics in superconducting quantum circuits

Superconducting qubits show great promise for the realization of fault-tolerant quantum computing, but lossy, amorphous dielectrics limit current technology. Identifying highly crystalline and stoichiometric dielectrics with intrinsically low microwave loss is therefore a central materials challenge, yet experimentally validated platforms remain scarce. In this work, we integrate a crystalline dielectric into a heteroepitaxial TiN/$γ$-Al$_2$O$_3$/TiN trilayer grown via pulsed laser deposition. Correlative high-resolution imaging, diffraction, and spectroscopy measurements confirm the single-crystal quality and chemical integrity of all layers, with minimal defects and limited anion interdiffusion across the oxide-nitride interfaces. Using microwave lumped-element resonators with parallel-plate capacitors, we report the first direct measurement of the dielectric loss of epitaxial $γ$-Al$_2$O$_3$, for which we find a low intrinsic two-level system loss, $δ_{\text{TLS}}^0 = (2.8 \pm 0.1) \times 10^{-5}$. These results establish heteroepitaxial oxides on transition metal nitrides as an attractive materials platform for superconducting quantum circuits, particularly for integration into compact device architectures such as merged-element transmons and microwave kinetic inductance detectors.

Garcia-Wetten, David A. [Northwestern U.]↗

New insights into the mechanism of ultrasonic atomization for the production of metal powders in additive manufacturing

Ultrasonic atomization is one of the promising technologies for producing metal powders for additive manufacturing, where precise control of particle size and morphology is essential. In this study, we coupled an ultrasonic transducer with a carbon fiber plate and atomized liquid droplets and films under different vibration amplitudes. Water, glycerol, and pure aluminum melt were used to study the atomization mechanism and the resulting droplet/powder characteristics, respectively. High-speed optical and ultrafast synchrotron X-ray imaging were used to study in situ the ultrasonic atomization dynamics, including pulsation and clustering of cavities inside the liquid layer/films, development of capillary waves, and formation of liquid droplets. For the first time, we observed and captured the occurrence of cavitation during the atomization of resting drops, films and impact droplets. The inertial cavitation events interfered with the capillary waves across the interphase boundary, puncturing and breaking the boundary to produce atomized mist. The in situ observation revealed the intricate dynamics of ultrasonic atomization and underscored the pivotal role of cavitation events throughout the entire atomization process. We also conducted experiments on ultrasonic atomization of liquid aluminum, producing particles of perfectly spherical shape. The particle size tended to decrease with reduced vibration amplitude Our work has demonstrated the important processing strategies on how to tailor the particle size while ensuring consistent particle shape and morphology, which is the key processing capability for producing high quality powders for additive manufacturing applications.

36 MATERIALS SCIENCE↗

Temperature Measurement of Laser-Irradiated Metals Using Hyperspectral Imaging

Accurate noncontact surface-temperature measurements during laser-based materials processing remain challenging due to the difficulty of establishing reliable emissivity values as a function of temperature and wavelength. Direct measurement of emissivity is difficult, as the emissivity may be changing constantly in the laser-material interaction region, where the temperature gradients are extreme and surface displacement can complicate the measurement. Here, we present a hyperspectral imaging method using a multiwavelength camera to capture the spectral radiance in eight different bands and fit the wavelength-dependent radiance to Planck’s law. Time-resolved temperature measurements during microsecond pulsed-laser irradiation of a metal plate made of the titanium alloy Ti -6 Al -4 V provide temperature information about the irradiated surface with an estimated accuracy of ± 10 % . The extracted wavelength-dependent emissivity slope compares well with reported results for macroscale titanium melts obtained using IR spectroscopy, which measure temperature without any built-in assumptions about the emissivity. The results are directly applicable to temperature monitoring during welding, additive manufacturing, and semiconductor growth.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A differential emissivity imaging technique for measuring hydrometeor mass and type

Abstract. The Differential Emissivity Imaging Disdrometer (DEID) is a new evaporation-based optical and thermal instrument designed to measure the mass, size, density and type of individual hydrometeors as well as their bulk properties. Hydrometeor spatial dimensions are measured on a heated metal plate using an infrared camera by exploiting the much higher thermal emissivity of water compared with metal. As a melted hydrometeor evaporates, its mass can be directly related to the loss of heat from the hotplate assuming energy conservation across the hydrometeor. The heat loss required to evaporate a hydrometeor is found to be independent of environmental conditions including ambient wind velocity, moisture level and temperature. The difference in heat loss for snow vs. rain for a given mass offers a method for discriminating precipitation phase. The DEID measures hydrometeors at sampling frequencies of up to 1 Hz with masses and effective diameters greater than 1 µg and 200 µm, respectively, determined by the size of the hotplate and the thermal camera specifications. Measurable snow water equivalent (SWE) precipitation rates range from 0.001 to 200 mm h−1, as validated against a standard weighing bucket. Preliminary field experiment measurements of snow and rain from the winters of 2019 and 2020 provided continuous automated measurements of precipitation rate, snow density and visibility. Measured hydrometeor size distributions agree well with canonical results described in the literature.

47 OTHER INSTRUMENTATION↗

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗

Breakdown and Discharge Characteristics of High Repetition Frequency Nanosecond Pulsed Air Dielectric Barrier Discharge

This study explores the breakdown characteristics and discharge modes in a parallel plate air dielectric barrier discharge system using repetitive nanosecond pulses, with pulse repetition frequencies (PRFs) from 0.1 to 100 kHz. It examines how pulse parameters—PRF, pulse number and gas pressure—affect the memory effect, leveraging current and voltage measurements, fast imaging and optical emission spectroscopy. The findings show that higher PRFs lead to a reduction in breakdown voltage well below the streamer breakdown threshold. We argue that this effect may be attributed to the cumulative buildup of metastable species and negative ions in the discharge gap which could sustain free electrons in‐between the voltage pulses. Despite observing increased energy deposition with higher PRFs, the impact on filament formation was minimal, highlighting a strong dependence of discharge morphology on the accumulation of plasma‐produced species. This research studies provides valuable insights for controlling discharge regimes in applications such as plasma‐assisted combustion, surface treatment and air treatment by clarifying the interactions between discharge mechanisms at different PRFs and pressures.

42 ENGINEERING↗

Lithium Metal Battery Quality Control via Transformer–CNN Segmentation

Lithium metal battery (LMB) has the potential to be the next-generation battery system because of its high theoretical energy density. However, defects known as dendrites are formed by heterogeneous lithium (Li) plating, which hinders the development and utilization of LMBs. Non-destructive techniques to observe the dendrite morphology often use X-ray computed tomography (XCT) to provide cross-sectional views. To retrieve three-dimensional structures inside a battery, image segmentation becomes essential to quantitatively analyze XCT images. This work proposes a new semantic segmentation approach using a transformer-based neural network called TransforCNN that is capable of segmenting out dendrites from XCT data. In addition, we compare the performance of the proposed TransforCNN with three other algorithms, U-Net, Y-Net, and E-Net, consisting of an ensemble network model for XCT analysis. Our results show the advantages of using TransforCNN when evaluating over-segmentation metrics, such as mean intersection over union (mIoU) and mean Dice similarity coefficient (mDSC), as well as through several qualitatively comparative visualizations.

Quenum, Jerome (ORCID:0000000271265853)↗

High strain-rate compression behavior of polymeric rod and plate Kelvin lattice structures

The compressive high strain-rate behavior of polymeric Kelvin lattice structures with rod-based or plate-based unit cells was investigated through experimental techniques and finite element simulations. Polymeric lattice structures with 5x5x5 unit cell geometries were manufactured on the millimeter scale using vat polymerization additive manufacturing and tested at low (0.001/s) and high (1000/s) strain-rates. High strain-rate experiments were performed and validated for a viscoelastic split-Hopkinson (Kolsky) pressure bar system (SHPB) coupled with high-speed imaging and digital image correlation (DIC). Experimental results at both low and high strain-rates show the formation of a localized deformation band which was more prevalent in low relative density specimens and low strain-rate experiments. Strain-rate effects of lattice specimens strongly correlate with effects of the base polymer material; both bulk polymer and lattice specimen demonstrated strain-rate hardening, strain-rate stiffening, and decreased fracture strain under dynamic loading. Results show mechanical failure properties and energy absorption depended strongly on the relative density of the lattice specimen and exhibited distinct scaling between relative density and geometry type (rod, plate) and loading rate. High relative density plate-lattices demonstrated inferior mechanical properties to rod-lattices; however, there exists a critical relative density for a given mechanical property (17%- 28%) below which plate-lattices outperform rod-lattices of similar mass. As a result, high strain-rate explicit finite element simulations were performed and showed good agreement with the mechanical failure trends and deformation modes observed in the experiments.

36 MATERIALS SCIENCE↗

Resistive Coatings for High-performance, Low-background MCPs Operating Across Broad Temperature Ranges and at Cryogenic Temperatures

Microchannel plate with improved thermo-electric properties are a high risk, high payoff development undertaken by a consortium of effort that links the Argonne National Lab, the Space-Science Lab at UC Berkeley and the small businesses (Incom Inc.) that will commercialize the advanced technology in open MCPs and LAPPDs. This development will satisfy the needs for new instrumentation for homeland security (non-proliferation) sensors to screen vehicles and cargo for Special Nuclear Materials (SNMs) and scientific detectors for astrophysics, electron microscopy, time-of-flight mass spectrometry, molecular and atomic collision studies, and fluorescence imaging applications in biotechnology and medical imaging products including positron emission tomography (PET scanning).

99 GENERAL AND MISCELLANEOUS↗

Tailoring copper current collector roughness and crystallographic orientation to improve lithium plating

Secondary lithium metal batteries are of great interest due to a high theoretical energy density, but rechargeability is limited by the formation of lithium dendrites that lead to internal short circuits and catastrophic cell failure. Mitigating dendrites through uniform current distribution at the current collector is a promising solution to enabling long cycle life of lithium metal electrodes. Here, the impact of copper crystal orientation and roughness on electrochemically deposited lithium morphology is studied. For 50 cycles, the capacity retention from greatest to least followed polycrystalline copper 95 ± 1 % (MC-PC) ≥ 94.55 ± 0.01 % Cu (110) > 93.0 ± 0.4 % Cu(111) > 75.8 ± 0.1 % Cu(100). Cu(100) performed the worst in all cases with shorts occurring frequently before reaching 50 cycles. Cryo-scanning electron microscopy images showed that after 50 cycles, MC-PC Cu had the best lithium morphology, but at early cycles, Cu(111) formed the densest lithium layer. MC-PC Cu had the most uniform lithium nucleation which may have been caused by increased roughness relative to the single crystal samples. When polycrystalline Cu (F-PC) roughness was systematically controlled, the cumulative Coulombic efficiency increased from about 0.3–0.5 with increasing roughness from an Ra of about 10–40 nm. Lastly, plating rates were studied. Slower rates of 0.25 mA/cm 2 exhibited denser lithium morphology in all cases as compared to 0.5 and 1.0 mA/cm 2 , but the relative porosity of Li deposited on the different current collectors depended on the rate applied.