Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERFEROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Terrestrial Planet Finder Interferometer: Architecture, Mission Design, and Technology Development

This slide presentation represents an overview progress report about the system design and technology development of two interferometer concepts studied for the Terrestrial Planet Finder (TPF) project. The two concepts are a structurally-connected interferometer (SCI) intended to fulfill minimum TPF science goals and a formation-flying interferometer (FFI) intended to fulfill full science goals. Described are major trades, analyses, and technology experiments completed. Near term plans are also described. This paper covers progress since August 2003

nulling↗

Phase Fluctuations at Goldstone Derived from 1-Year Site Testing Interferometer Data

A two-element site test interferometer has been deployed at the NASA Deep Space Network (DSN) tracking complex in Goldstone, California, since May 2007. The interferometer system consists of two offset-fed 1.2 m parabolic reflectors which monitor atmospheric-induced amplitude and phase fluctuations on an unmodulated beacon signal (20.199 GHz) broadcast from a geostationary satellite (Anik F2). The geometry of the satellite and the ground-based infrastructure imposes a 48.5 elevation angle with a separation distance of 256 m along an east-west baseline. The interferometer has been recording phase fluctuation data, to date, for 1 yr with an overall system availability of 95 percent. In this paper, we provide the cumulative distribution functions (CDFs) for 1 year of recorded data, including phase rms, spatial structure function exponent, and surface meteorological measurements: surface wind speed, relative humidity, temperature, barometric pressure, and rain rate. Correlation between surface measurements, phase rms, and amplitude rms at different time scales are discussed. For 1 year, phase fluctuations at the DSN site in Goldstone, are better than 23 for 90 percent of the time (at 48.5 elevation). This data will be used to determine the suitability of the Goldstone site as a location for the Next Generation Deep Space Network.

Nessel, James A.↗

Design Enhancements of the Fourier Kelvin Stellar Interferometer to Enable Detection of Earth Twins

During the last few years, considerable effort has been directed towards very large-scale (> $5 billion) missions to detect and characterize Mars-radius to Earth-radius planets around nearby stars; such as the Terrestrial Planet Finder Interferometer and Darwin missions. However, technological issues such as formation flying and control of systematic noise sources will likely prevent these missions from entering Phase A until at least the end of the next decade. Presently more than 350 planets have been discovered by a variety of techniques, and little is known about the majority of them other than their approximate mass. However, a simplified nulling interferometer operating in the near- to mid-infrared (e.g. approx. 5-15 microns), like the enhanced version of the Fourier Kelvin Stellar Interferometer (FKSI), can characterize the atmospheres of a large sample of the known planets - including Earth twins. Many other scientific problems can be addressed with a system like FKSI, including the studies of debris disks, active galactic nuclei, and low mass companions around nearby stars. We report results of a recent engineering study on an enhanced version of FKSI that includes 1-meter primary mirrors, 20-meter boom length, and an advanced sun shield that will provide a 45-degree FOR and 40K operating temperature for all optics including siderostats.

Barry, Richard K.↗

Sub-Aperture Interferometers

Sub-aperture interferometers -- also called wavefront-split interferometers -- have been developed for simultaneously measuring displacements of multiple targets. The terms "sub-aperture" and "wavefront-split" signify that the original measurement light beam in an interferometer is split into multiple sub-beams derived from non-overlapping portions of the original measurement-beam aperture. Each measurement sub-beam is aimed at a retroreflector mounted on one of the targets. The splitting of the measurement beam is accomplished by use of truncated mirrors and masks, as shown in the example below

Zhao, Feng↗

Measuring Cyclic Error in Laser Heterodyne Interferometers

An improved method and apparatus have been devised for measuring cyclic errors in the readouts of laser heterodyne interferometers that are configured and operated as displacement gauges. The cyclic errors arise as a consequence of mixing of spurious optical and electrical signals in beam launchers that are subsystems of such interferometers. The conventional approach to measurement of cyclic error involves phase measurements and yields values precise to within about 10 pm over air optical paths at laser wavelengths in the visible and near infrared. The present approach, which involves amplitude measurements instead of phase measurements, yields values precise to about .0.1 microns . about 100 times the precision of the conventional approach. In a displacement gauge of the type of interest here, the laser heterodyne interferometer is used to measure any change in distance along an optical axis between two corner-cube retroreflectors. One of the corner-cube retroreflectors is mounted on a piezoelectric transducer (see figure), which is used to introduce a low-frequency periodic displacement that can be measured by the gauges. The transducer is excited at a frequency of 9 Hz by a triangular waveform to generate a 9-Hz triangular-wave displacement having an amplitude of 25 microns. The displacement gives rise to both amplitude and phase modulation of the heterodyne signals in the gauges. The modulation includes cyclic error components, and the magnitude of the cyclic-error component of the phase modulation is what one needs to measure in order to determine the magnitude of the cyclic displacement error. The precision attainable in the conventional (phase measurement) approach to measuring cyclic error is limited because the phase measurements are af-

Ryan, Daniel↗

Heterodyne Interferometer Angle Metrology

A compact, high-resolution angle measurement instrument has been developed that is based on a heterodyne interferometer. The common-path heterodyne interferometer metrology is used to measure displacements of a reflective target surface. In the interferometer setup, an optical mask is used to sample the measurement laser beam reflecting back from a target surface. Angular rotations, around two orthogonal axes in a plane perpendicular to the measurement- beam propagation direction, are determined simultaneously from the relative displacement measurement of the target surface. The device is used in a tracking telescope system where pitch and yaw measurements of a flat mirror were simultaneously performed with a sensitivity of 0.1 nrad, per second, and a measuring range of 0.15 mrad at a working distance of an order of a meter. The nonlinearity of the device is also measured less than one percent over the measurement range.

Hahn, Inseob↗

Handheld White Light Interferometer for Measuring Defect Depth in Windows

Accurate quantification of defects (scratches and impacts) is vital to the certification of flight hardware and other critical components. The amount of damage to a particular component contributes to the performance, reliability, and safety of a system, which ultimately affects the success or failure of a mission or test. The launch-commit criteria on a Space Shuttle Orbiter window are governed by the depth of the defects that are identified by a visual inspection. This measurement of a defect is not easy to obtain given the environment, size of the defect, and location of the window(s). The determination of depth has typically been performed by taking a mold impression and measuring the impression with an optical profiling instrument. Another method of obtaining an estimate of the depth is by using a refocus microscope. To use a refocus microscope, the surface of the glass and bottom of the defect are, in turn, brought into focus by the operator. The amount of movement between the two points corresponds to the depth of the defect. The refocus microscope requires a skilled operator and has been proven to be unreliable when used on Orbiter windows. White light interferometry was chosen as a candidate to replace the refocus microscope. The White Light Interferometer (WLI) was developed to replace the refocus microscope as the instrument used for measuring the depth of defects in Orbiter windows. The WLI consists of a broadband illumination source, interferometer, detector, motion control, displacement sensor, mechanical housing, and support electronics. The illumination source for the WLI is typically a visible light emitting diode (LED) or a near-infrared superluminescent diode (SLD) with power levels of less than a milliwatt. The interferometer is a Michelson configuration consisting of a 1-in. (2.5-cm) cube beam splitter, a 0.5-in. (1.3-cm) optical window as a movable leg (used to closely match the return intensity of the fixed leg from the window), and a mirrored prism to fold the optics into the mechanical housing. The detector may be one of many C-mount CCD (charge-coupled device) cameras. Motion is provided by a commercial nanostepping motor with a serial interface. The displacement sensor is a custom device specifically designed for this application. The mechanical housing and support electronics were designed to integrate the various components into an instrument that could be physically handled by a technician and easily transported.

Youngquist, Robert↗

Gravitational Wave Detection with Single-Laser Atom Interferometers

A new design for a broadband detector of gravitational radiation relies on two atom interferometers separated by a distance L. In this scheme, only one arm and one laser are used for operating the two atom interferometers. The innovation here involves the fact that the atoms in the atom interferometers are not only considered as perfect test masses, but also as highly stable clocks. Atomic coherence is intrinsically stable, and can be many orders of magnitude more stable than a laser.

Yu, Nan↗

High Resolution Rapid Response Observations of Compact Radio Sources with the Ceduna Hobart Interferometer (CHI)

Context. Frequent, simultaneous observations across the electromagnetic spectrum are essential to the study of a range of astrophysical phenomena including Active Galactic Nuclei. A key tool of such studies is the ability to observe an object when it flares i.e. exhibits a rapid and significant increase in its flux density. Aims. We describe the specific observational procedures and the calibration techniques that have been developed and tested to create a single baseline radio interferometer. that can rapidly observe a flaring object. This is the only facility that is dedicated to rapid high resolution radio observations of an object south of -30 degrees declination. An immediate application is to provide rapid contemporaneous radio coverage of AGN flaring at y-ray frequencies detected by the Fermi Gamma-ray Space Telescope. Methods. A single baseline interferometer was formed with radio telescopes in Hobart, Tasmania and Ceduna, South Australia. A software correlator was set up at the University of Tasmania to correlate these data. Results. Measurements of the flux densities of flaring objects can be made using our observing strategy within half an hour of a triggering event. These observations can be calibrated with amplitude errors better than 20%. Lower limits to the brightness temperatures of the sources can also be calculated using CHI. Key words. instrumentation:interferometers - galaxies:active - galaxies:jets - galaxies:nuclei quasars:general gamma rays:galaxies- 1.

Blanchard, Jay M.↗

Prospects for Observing Ultracompact Binaries with Space-Based Gravitational Wave Interferometers and Optical Telescopes

Space-based gravitational wave interferometers are sensitive to the galactic population of ultracompact binaries. An important subset of the ultracompact binary population are those stars that can be individually resolved by both gravitational wave interferometers and electromagnetic telescopes. The aim of this paper is to quantify the multimessenger potential of space-based interferometers with arm-lengths between 1 and 5 Gm. The Fisher information matrix is used to estimate the number of binaries from a model of the Milky Way which are localized on the sky by the gravitational wave detector to within 1 and 10 deg(exp 2) and bright enough to be detected by a magnitude-limited survey.We find, depending on the choice ofGW detector characteristics, limiting magnitude and observing strategy, that up to several hundred gravitational wave sources could be detected in electromagnetic follow-up observations.

Littenberg, T. B.↗

High-Precision Narrow Angle Astrometry with a Space-Borne Interferometer

This paper develops an observing and processing scheme for narrow angle astrometry using a single baseline interferometer without the aid of "grid" stars to characterize the interferometer baseline vector in inertial space. The basic concept derives from the recognition that over a narrow field the set of fundamental unknown instrument parameters that arise because the interferometer baseline vector has large uncertainties (since there are no grid star measurements) is indistinguishable from a particular set of unobservable errors in the determination of star positions within the field. Reference stars within the narrow field of regard are used to circumvent the unobservable modes. Feasibility of the approach is demonstrated through analysis and example simulations.

astrometry↗

Terrestrial Planet Finder Interferometer: 2007-2008 Progress and Plans

This paper provides an overview of technology development for the Terrestrial Planet Finder Interferometer (TPF-I). TPF-I is a mid-infrared space interferometer being designed with the capability of detecting Earth-like planets in the habitable zones around nearby stars. The overall technology roadmap is presented and progress with each of the testbeds is summarized. The current interferometer architecture, design trades, and the viability of possible reduced-scope mission concepts are also presented.

formation flying↗

The StarLight interferometer architecture and operational concepts

The StarLight flight project was designed to demonstrate the key technologies of spacebome long-baseline stellar interferometry and precision formation flying for potential use on the Terrestrial Planet Finder (TPF) and other future astrophysics missions. Interferometer performance validation could be achieved over a 6-12 month period by obtaining several hundred fringe visibility amplitude measurements for stars in the band 600-1000 nm for a variety of stellar visibilities (0.2-1.0), magnitudes (Mv = 2-5), and baselines (B = 30-125 meters). Interferometry could be performed both in a 1 meter fixed-baseline combiner-only mode and in a two-spacecraft formation mode. In formation mode, the combiner spacecraft would remain at the focus of a virtual parabola, while the collector spacecraft assumed various positions along the parabola such that the two arms of the interferometer remained equal over a variety of separations and bearing angles. Challenges to be encountered in flight include high-bandwidth inter-spacecraft stellar and metrology pointing control, alignment and shear correction, delay and delay-rate estimation, visibility calibration, and robust fringe tracking in the presence of local and inter-spacecraft dynamics. This paper is based on the StarLight project design-capture of March 2002 and will describe the StarLight Interferometer System architecture and selected operational concepts (both of which have relevance to the on-going TPF Technology Program).

stellar↗

A desktop interferometer for optical synthesis imaging

A simple desktop optical interferometer is described and demonstrated as a teaching tool for concepts of long-baseline stellar interferometry. The invariance of closure phase is introduced and illustrated. The differences between image synthesis with this interferometer and astronomical interferometers are shown and discussed.

interferometry↗

Graphene-Based Quantum Hall Interferometer with Self-Aligned Side Gates

The vanishing band gap of graphene has long presented challenges for fabricating high-quality quantum point contacts (QPCs)–the partially transparent p-n interfaces introduced by conventional split-gates tend to short the QPC. This complication has hindered the fabrication of graphene quantum Hall Fabry-P'erot interferometers, until recent advances have allowed split-gate QPCs to operate utilizing the highly resistive ν = 0 state. Here, we present a simple recipe to fabricate QPCs by etching a narrow trench in the graphene sheet to separate the conducting channel from self-aligned graphene side gates. Finally, we demonstrate operation of the individual QPCs in the quantum Hall regime, and further utilize these QPCs to create and study a quantum Hall interferometer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and characterization of a single-channel microwave interferometer for the Helicon Physics Prototype eXperiment

A heterodyne interferometer for measuring the plasma electron density in Helicon Physics Prototype eXperiment (HPPX) has been developed and characterized in the laboratory. The heterodyne-type interferometer uses a probing beam of 85 GHz and a reference beam of 85.7 GHz by using two Gunn oscillators for facilitating frequency modulation. The cutoff density for this frequency is 8.96 x 10 19 m –3 that is much higher than the nominal electron density of the HPPX plasmas. The maximum deflection angle due to the refraction effect is estimated to be 0.63° assuming a parabolic electron density profile, and the impact on the measurement is negligible for the plasmas with a size of 100 mm. Two identical HDPE lenses act as the vacuum windows, and the lenses working together with the transmitter and receiver horns, form a beam with the beam waist of about 20 mm located at the plasma center. The characterization results of the lens and the critical microwave components show good performance. The plasma electron density measurement results are in line with the expectation. Furthermore, the Signal to Noise Ratio (SNR) of the measurement is defined as SNR = 20lg($\bar{n}_{e}$/S), where $\bar{n}_{e}$ and S are respectively the average electron density and the standard deviation of the signal, and the SNR is 80 dB. Finally, this demonstrates the system's capability of providing a clear and detailed density resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗