Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTEGRAL DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Investigation of a {sup 90}Sr/{sup 90}Y source for intra-ocular treatment of wet age-related macular degeneration

Purpose: The purpose of this study is to perform an extensive investigation of an approximately 2.5 mm long {sup 90}Sr/{sup 90}Y source designed for treating wet age-related macular degeneration. Methods: As part of this investigation, a NIST-traceable absorbed dose to water calibration technique was established, and a source deployment verification test was developed. The influence of treatment cannula construction tolerance on the measurements as well as the dose delivered to the patient was investigated using the Monte Carlo code MCNP5. Variation between production cannulae was quantified experimentally using a well-type ionization chamber, and additional measurements along with Monte Carlo calculations of the collimating insert used for source deployment verification were performed to validate the model. Results: Maximum variation in the integrated target dose was seen when the source was shifted laterally within the treatment cannula. For the well chamber measurements, the observed standard deviation in ionization current for a single source placed in different reference cannulae was {+-}0.3%, with a maximum observed range of less than {+-}0.5%. Clinical cannulae in the collimating insert showed an average of 17.8%{+-}0.4% of the reference signal when sources were fully deployed compared to 18.5% predicted by Monte Carlo calculations. This discrepancy has been attributed primarily to construction of the collimator since the collimation gap was observed to be approximately 0.025-0.075 mm smaller than specified. Construction tolerance of the well chamber insert as well as position tolerance of the cannula tip were both investigated, and their influence on the predicted signal was quantified. Additional measurements along with Monte Carlo based calculations of the collimating insert with polyethylene spacers added to the setup were performed to validate the Monte Carlo model. The shimmed Monte Carlo and measured data agree to within 1%, which is a magnitude difference of approximately 0.1% of the reference signal. Conclusions: This investigation confirms that the signal for an acceptably deployed source in the collimating insert is between 17.5% and 21.5% of the reference signal, as calculated using Monte Carlo models. Clinical cannulae for which the source deployment verification measurement falls outside the acceptable range should not be used to treat patients.

07 ISOTOPE AND RADIATION SOURCES↗

Radiation dose assessment in a 320-detector-row CT scanner used in cardiac imaging

Purpose: In the present era of cone-beam CT scanners, the use of the standardized CTDI{sub 100} as a surrogate of the idealized CTDI is strongly discouraged and, consequently, so should be the use of the dose-length product (DLP) as an estimate of the total energy imparted to the patient. However, the DLP is still widely used as a reference quantity to normalize the effective dose for a given scan protocol mainly because the CTDI{sub 100} is an easy-to-measure quantity. The aim of this article is therefore to describe a method for radiation dose assessment in large cone-beam single axial scans, which leads to a straightforward estimation of the total energy imparted to the patient. The authors developed a method accessible to all medical physicists and easy to implement in clinical practice in an attempt to update the bridge between CT dosimetry and the estimation of the effective dose. Methods: The authors used commercially available material and a simple mathematical model. The method described herein is based on the dosimetry paradigm introduced by the AAPM Task Group 111. It consists of measuring the dose profiles at the center and the periphery of a long body phantom with a commercial solid-state detector. A weighted dose profile is then calculated from these measurements. To calculate the CT dosimetric quantities analytically, a Gaussian function was fitted to the dose profile data. Furthermore, the Gaussian model has the power to condense the z-axis information of the dose profile in two parameters: The single-scan central dose, f(0), and the width of the profile, {sigma}. To check the energy dependence of the solid-state detector, the authors compared the dose profiles to measurements made with a small volume ion chamber. To validate the overall method, the authors compared the CTDI{sub 100} calculated analytically to the measurement made with a 100 mm pencil ion chamber. Results: For the central and weighted dose profiles, the authors found a good agreement between the measured dose profile data and the fitted Gaussian functions. The solid-state detector had no energy dependence--within the energy range of interest--and the analytical model succeeded in reproducing the absolute dose values obtained with the pencil ion chamber. For the case of large cone-beam single axial scans, the quantity that better characterizes the total energy imparted to the patient is the weighted dose profile integral (DPI{sub w}). The DPI{sub w} can be easily determined from the two parameters that define the Gaussian functions: f(0) and {sigma}. The authors found that the DLP underestimated the total energy imparted to the patient by more than 20%. The authors also found that the calculated CT dosimetric quantities were higher than those displayed on the scanner console. Conclusions: The authors described and validated a method to assess radiation dose in large cone-beam single axial scans. This method offers a simple and more accurate estimation of the total energy imparted to the patient, thus offering the possibility to update the bridge between CT dosimetry and the estimation of the effective dose for cone-beam CT examinations in radiology, nuclear medicine, and radiation therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Radiation-Induced Hippocampal Vascular Injury Surrogate Marker Predicts Late Neurocognitive Dysfunction

Purpose: We aimed to develop a hippocampal vascular injury surrogate marker for early prediction of late neurocognitive dysfunction in patients receiving brain radiation therapy (RT). Methods and Materials: Twenty-seven patients (17 males and 10 females, 31-80 years of age) were enrolled in an institutional review board-approved prospective longitudinal study. Patients received diagnoses of low-grade glioma or benign tumor and were treated by (3D) conformal or intensity-modulated RT with a median dose of 54 Gy (50.4-59.4 Gy in 1.8-Gy fractions). Six dynamic-contrast enhanced MRI scans were performed from pre-RT to 18-month post-RT, and quantified for vascular parameters related to blood-brain barrier permeability, K{sup trans}, and the fraction of blood plasma volume, V{sub p}. The temporal changes in the means of hippocampal transfer constant K{sup trans} and V{sub p} after starting RT were modeled by integrating the dose effects with age, sex, hippocampal laterality, and presence of tumor or edema near a hippocampus. Finally, the early vascular dose response in hippocampi was correlated with neurocognitive dysfunction at 6 and 18 months post-RT. Results: The mean K{sup trans} Increased significantly from pre-RT to 1-month post-RT (P<.0004), which significantly depended on sex (P<.0007) and age (P<.00004), with the dose response more pronounced in older females. Also, the vascular dose response in the left hippocampus of females correlated significantly with changes in memory function at 6 (r=−0.95, P<.0006) and 18-months (r=−0.88, P<.02) post-RT. Conclusions: The early hippocampal vascular dose response could be a predictor of late neurocognitive dysfunction. A personalized hippocampus sparing strategy may be considered in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detailed Comparison of Observed Dose-Time Profile of October 19-20, 1989 SPE on Mir with Model Calculations

The dose rate dynamics of the October 19-20,1989 solar energetic particle (SPE) event as observed by the Liulin instrument onboard the Mir orbital station was analyzed in light of new calculations of the geomagnetic cutoff and improved estimates of the less than 100 MeV energy spectra from the GOES satellite instrument. The new calculations were performed using the as-flown Mir orbital trajectory and includes time variations of the cutoff rigidity due to changes in the kappa (sub p) index. Although the agreement of total event integrated calculated dose to the measured dose is good, it results from some measured dose-time profile been higher and some lower than model calculations. They point to the need to include the diurnal variation of the geomagnetic cutoff and modifications of the cutoffs to variations in kappa (sub p) in model calculations. Understanding of such events in light of the upcoming construction of the International Space Station during the period of maximum solar activity needs to be vigorously pursued.

Badhwar, Gautam D.↗

A Three-Isocenter Jagged-Junction IMRT Approach for Craniospinal Irradiation Without Beam Edge Matching for Field Junctions

Purpose: Traditionally craniospinal irradiation treats the central nervous system using two or three adjacent field sets. We propose a technique using a three-isocenter intensity-modulated radiotherapy (IMRT) plan (jagged-junction IMRT) which overcomes problems associated with field junctions and beam edge matching and improves planning and treatment setup efficiencies with homogenous target dose distribution. Methods and Materials: Treatments for 3 patients with a prescription of 36 Gy in 20 fractions were retrospectively planned with jagged-junction IMRT and compared to conventional treatment plans. Planning target volume (PTV) included the whole brain and spinal canal to the S3 vertebral level. The plan used three field sets, each with a unique isocenter. One field set with seven fields treated the cranium. Two field sets treated the spine, each set using three fields. Fields from adjacent sets were overlapped, and the optimization process smoothly integrated the dose inside the overlapped junction. Results: For jagged-junction IMRT plans vs. conventional technique, the average homogeneity index equaled 0.08 {+-} 0.01 vs. 0.12 {+-} 0.02, respectively, and conformity number equaled 0.79 {+-} 0.01 vs. 0.47 {+-} 0.12, respectively. The 95% isodose surface covered (99.5 {+-} 0.3)% of the PTV vs. (98.1 {+-} 2.0)%, respectively. Both jagged-junction IMRT plans and the conventional plans had good sparing of organs at risk. Conclusions: Jagged-junction IMRT planning provided good dose homogeneity and conformity to the target while maintaining a low dose to organs at risk. Results from jagged-junction IMRT plans were better than or equivalent to those from the conventional technique. Jagged-junction IMRT optimization smoothly distributed dose in the junction between field sets. Because there was no beam matching, this treatment technique is less likely to produce hot or cold spots at the junction, in contrast to conventional techniques. The planning process is also simplified as only one IMRT plan is required for the entire target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and Performance of an InAs Quantum Dot Scintillator with Integrated Photodetector

A new scintillation material composed of InAs quantum dots (QDs) hosted within a GaAs matrix was developed, and its performance with different types of radiation is evaluated. A methodology for designing an integrated photodetector (PD) with a low defect density and that is optically matched to the QD’s emission spectrum is introduced, utilizing an engineered epitaxial InAlGaAs metamorphic buffer layer. The photoluminescence (PL) collection efficiency of the integrated PD is examined using two-dimensional scanning laser excitation. The detector response to 5.5 MeV α-particles and 122 keV photons is presented. Yields of 13 electrons/keV for α-particles and 30–60 electrons/keV for photons were observed. The energy resolution of 12% observed with α-particles was mainly limited by noise- and geometry-related optical losses. The radiation hardness of an InAs QDs hosted within GaAs and a wider band gap AlGaAs ternary alloy was studied under a 1 MeV proton implantation up to a 10 14 cm –2 dose. The integrated PL responses were compared to evaluate PL quenching due to non-radiative defects. The QDs embedded in the AlGaAs demonstrated improved radiation hardness compared to QDs in the GaAs matrix and in the InGaAs quantum wells.

36 MATERIALS SCIENCE↗

TH-C-BRD-09: Successes and Limitations of Online Range Adaptive Spot Scanning Proton Therapy for NSCLC

Purpose: To determine the ability to adapt discrete spot-scanning proton therapy (SSPT) plans based on geometric changes of anatomy to minimize normal tissue dose and maintain target coverage. Methods: We developed and tested a range-correction algorithm to compensate for anatomy changes in SSPT with correction factors for target lateral size changes and energy scaling. This algorithm adjusts the energy of each spot from the original optimized treatment plan to match the new daily anatomy based on water equivalent path-length. To correct for the lateral target size changes, the peripheral spots were scaled based on phantom studies with variable target size. For energy change corrections, alternative cumulative scaling factor lookup tables were generated based on calculated central-axis and integral depth dose calculations for different energies. These various adaptive algorithms were performed on 7 lung cancer patients that were previously treated with proton therapy and who required at least one adaptive intervention. Single-field optimized SSPT plans were generated for these patients with clinical beam angles. Dose-volume histogram metrics were obtained for these patients for both the non-adaptive and the different adaptive plans applied to the last available weekly CT scan. Results: The doses to normal tissue were largely reduced for the spinal cord (Dmax), total lung (V20Gy), and contralateral lung (V20Gy) for all different methods of adaptive planning. With both corrections applied, the average changes for these metrics were −6.2Gy, −2.7%, and −4.9%, respectively. The same method generated unacceptably high target hot spots with average target V110% increase of 12.3%. Conclusion: Adaptive methods based on direct adjustments to proton range can reduce normal tissue doses under large anatomical changes but are insufficient in achieving clinically acceptable target doses and generate unacceptably sizeable hot spots. Adaptive planning methods for proton therapy will likely necessitate some aspect of reoptimization for acceptable clinical utility.

60 APPLIED LIFE SCIENCES↗

APOBEC3G restricts early HIV-1 replication in the cytoplasm of target cells

Cellular APOBEC3G (A3G) protein is packaged into human immunodeficiency virus type 1 (HIV-1) virions in producer cells yet restricts viral replication in target cells. To characterize this restriction in target cells, the effect of A3G on generating various HIV-1 cDNA products was measured by quantitative real-time PCR. A3G decreased cDNA products from Vif-deficient HIV-1, with minor effects on early reverse transcripts and larger declines in late reverse transcripts. However, the greatest decline was typically observed in nuclear 2-LTR circles. Moreover, the magnitude of these declines varied with A3G dose. Adding integration inhibitor did not stop the A3G-mediated loss in 2-LTR circles. Moreover, obstructing HIV-1 nuclear entry using vesicular stomatitis virus matrix protein did not stop the A3G-mediated decline in late reverse transcripts. Collectively, these data suggest that A3G has important restriction activity in the cytoplasm and progressively diminishes viral cytoplasmic and nuclear cDNA forms with increasing magnitude during restriction.

60 APPLIED LIFE SCIENCES↗

Dose Consequence and Probabilistic Risk Assessment Integration into Digital Documented Safety Analysis

This is an intern poster presentation. The current reactor authorization process is complex and error prone. The development of a digital Documented Safety Analysis has been proposed to provide an automated and integrated solution to enhance the design and authorization process. The digital DSA will consist of interlinked models, analyses, and reports, all of which will be updated using automated workflows when design changes are made. This poster examines the integration of the probabilistic risk assessment (PRA) with the transient and dose consequence analyses. A PRA for a generic high temperature gas-cooled reactor (HTGR) has been constructed which will drive the input parameters for a transient analysis model currently being constructed. Dose consequence will be determined using the results of the transient analysis and the Radiation Safety Analysis Computer (RSAC) code. Dose consequence data will then be input back into the PRA to drive design parameters.

42 ENGINEERING↗

Structural Modification of Graphene on Copper Substrates Irradiated by Nanosecond High-Intensity Ion Beams

Interaction of a nanosecond high-intensity pulsed ion beam with thin graphene films on copper substrates is analyzed. Methods of Raman spectroscopy are used to investigate the degree of graphene degradation depending on the integral implanted dose. The role of the substrate in the structural degradation of graphene irradiated by charged particle beams is demonstrated using the software package SRIM, intended for modeling radiative defect cascades under irradiation by charged particle beams, and the data on radiation resistance of graphene available in the literature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Designing Antifouling and Antimicrobial Interfaces: Structural Characterization using CryoEM, Automated Microscopy, and AI Image Segmentation

The design of functionalized surfaces for interactions with biological systems is critical across sectors such as healthcare, energy, and agriculture. Tailoring materials for specific applications, such as antifouling and antimicrobial surfaces, demands a comprehensive understanding of topology and chemistry across multiple length and time scales on both biological and materials systems. This work presents the development and characterization of nanostructured surfaces with controlled topographies and chemistries that enhance bacterial membrane disruption, reduce biofilm formation, and improve antimicrobial and antifouling capabilities. Two specific use cases will be presented - the use of cellulose nanocrystals (CNCs) for bacterial growth inhibition and the development of antifouling surfaces to prevent protein and bacterial adsorption [1-4]. By leveraging large language models (LLMs) for image segmentation and training [5], we enable automated analysis of terabyte-scale cryogenic electron microscopy (cryoEM) datasets. This analysis provides statistical insights into the biotic/abiotic interface and facilitates automated electron microscopy experiments to mitigate time and dose. The integration of cryogenic electron tomography (cryoET) and cryogenic focused ion beam (cryoFIB) milling enables high-resolution, near-native-state imaging and 3D reconstructions of bio/material interfaces [6]. Orthogonal characterization techniques and computational modeling further enhances our understanding, offering a robust platform for the design and optimization of next-generation functional surfaces [7].

Williams, Alexis [ORNL] (ORCID:0000000252835822)↗

Accuracy of Analog Fiber-Optic Links in Pulsed Radiation Environments

Interferometric fiber-optic links used in pulsed-power experiments are evaluated for accuracy in the presence of radiation fields which alter fiber transmission. Amplitude-modulated format (e.g., Mach-Zehnder) and phase-modulated formats are compared. Historically, studies of radiation effects on optical fibers have focused on degradation and recovery of the fibers transmission properties; such work is either in the context of survivability of fibers in catastrophic conditions or suitability of fibers installed for command and control systems within an experimental facility [1], [2]. In this work, we consider links used to transmit realtime diagnostic data, and we analyze the error introduced by radiation effects during the drive pulse. The result is increased uncertainties in key parameters required to unfold the sinusoidal transfer function. Two types of modulation are considered: amplitude modulation typical of a Mach-Zehnder (M-Z) modulator [3], and phase modulation, which offers more flexible demodulation options but relies on the spatiotemporal coherence of the light in the fiber. The M-Z link is shown schematically in Fig. 1, and the phase-modulated link is shown in Fig. 2. We present data from two experimental environments: one with intense, controlled radiation fields to simulate conditions expected at the next generation of pulsed-power facilities, and the second with radiation effects below the noise level of the recording system. In the first case, we intentionally expose three types of single-mode fiber (SMF) to ionizing radiation and study the response by simultaneously monitoring phase and amplitude of the transmitted light. The phase and amplitude effects are evidently dominated by different physical phenomena, as their recovery dynamics are markedly different; both effects, though, show similar short-term behavior during exposure, integrating the dose at the dose levels studied, from 1 to 300 kRad, over the exposure times of 50 ps and 30 ns. In the second case, we present data using a state-of-the-art fiber-optic link for single-shot transmission and recording, fielded at the OMEGA laser facility on high-yield fusion experiments. Gamma reaction history data are measured with a gas Cherenkov detector (GCD) [4], [5] and transmitted by M-Z link to a 12 GHz digitizer. Since radiation effects on the fibers are not above the noise floor, the error analysis for the unfolded data is dominated by the performance of the fast digitizer, the photoreceiver, and the laser.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An enhanced sector integration model for output and dose distribution calculation of irregular concave shaped electron beams

A comprehensive method of output factor and dose distribution calculation for electron beams has been developed. It allows one to calculate the output factors and isodose distributions in water of arbitrary shaped electron fields with excellent accuracy even for the cases of concaved, small, elongated beams, and extended source to surface distances (SSDs). The method requires two sets of data: Depth dose distribution per monitor unit for circular cutouts and depth dose distributions per monitor unit for circular blocks (plugs), both for two SSDs, one reference of 100 cm and second extended one. The method has been extensively tested using a combination of different irregular cutouts and various SSDs for the 6 and 9 MeV electron beams. The calculated values agreed with the measured data well within 1% for output factors and below 1 for {gamma} (gamma test) for isodose distributions. The computer program has been developed to facilitate the method for practical application. The method has been used for almost 8 years considerably cutting workload in the department.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-314: The Application of Cloud Computing in Pencil Beam Scanning Proton Therapy Monte Carlo Simulation

Purpose: Monte Carlo simulation plays an important role for proton Pencil Beam Scanning (PBS) technique. However, MC simulation demands high computing power and is limited to few large proton centers that can afford a computer cluster. We study the feasibility of utilizing cloud computing in the MC simulation of PBS beams. Methods: A GATE/GEANT4 based MC simulation software was installed on a commercial cloud computing virtual machine (Linux 64-bits, Amazon EC2). Single spot Integral Depth Dose (IDD) curves and in-air transverse profiles were used to tune the source parameters to simulate an IBA machine. With the use of StarCluster software developed at MIT, a Linux cluster with 2–100 nodes can be conveniently launched in the cloud. A proton PBS plan was then exported to the cloud where the MC simulation was run. Results: The simulated PBS plan has a field size of 10×10cm{sup 2}, 20cm range, 10cm modulation, and contains over 10,000 beam spots. EC2 instance type m1.medium was selected considering the CPU/memory requirement and 40 instances were used to form a Linux cluster. To minimize cost, master node was created with on-demand instance and worker nodes were created with spot-instance. The hourly cost for the 40-node cluster was $0.63 and the projected cost for a 100-node cluster was $1.41. Ten million events were simulated to plot PDD and profile, with each job containing 500k events. The simulation completed within 1 hour and an overall statistical uncertainty of < 2% was achieved. Good agreement between MC simulation and measurement was observed. Conclusion: Cloud computing is a cost-effective and easy to maintain platform to run proton PBS MC simulation. When proton MC packages such as GATE and TOPAS are combined with cloud computing, it will greatly facilitate the pursuing of PBS MC studies, especially for newly established proton centers or individual researchers.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-188: Commission of World 1st Commercial Compact PBS Proton System

Purpose: ProteusONE is the 1st commercial compact PBS proton system with an upstream scanning gantry and C230 cyclotron. We commissioned XiO and Raystation TPS simultaneously. This is a summary of beam data collection, modeling, and verification and comparison without range shiter for this unique system with both TPS. Methods: Both Raystation and XiO requires the same measurements data: (i) integral depth dose(IDDs) of single central spot measured in water tank; (ii) absolute dose calibration measured at 2cm depth of water with mono-energetic 10×10 cm2 field with spot spacing 4mm, 1MU per spot; and (iii) beam spot characteristics in air at 0cm and ± 20cm away from ISO. To verify the beam model for both TPS, same 15 cube plans were created to simulate different treatment sites, target volumes and positions. PDDs of each plan were measured using a Multi-layer Ionization Chamber(MLIC), absolute point dose verification were measured using PPC05 in water tank and patient-specific QA were measured using MatriXX PT, a 2D ion chamber array. Results: All the point dose measurements at midSOBP were within 2% for both XiO and Raystation. However, up to 5% deviations were observed in XiO’s plans at shallow depth while within 2% in Raystation plans. 100% of the ranges measured were within 1 mm with maximum deviation of 0.5 mm. 20 patient specific plan were generated and measured in 3 planes (distal, proximal and midSOBP) in Raystation. The average of gamma index is 98.7%±3% with minimum 94% Conclusions: Both TPS were successfully commissioned and can be safely deployed for clinical use for ProteusONE. Based on our clinical experience in PBS planning, user interface, function and workflow, we preferably use Raystation as our main clinical TPS. Gamma Index >95% at 3%/3 mm criteria is our institution action level for patient specific plan QAs.

60 APPLIED LIFE SCIENCES↗

A patient-specific aperture system with an energy absorber for spot scanning proton beams: Verification for clinical application

Purpose: In the authors’ proton therapy system, the patient-specific aperture can be attached to the nozzle of spot scanning beams to shape an irradiation field and reduce lateral fall-off. The authors herein verified this system for clinical application. Methods: The authors prepared four types of patient-specific aperture systems equipped with an energy absorber to irradiate shallow regions less than 4 g/cm{sup 2}. The aperture was made of 3-cm-thick brass and the maximum water equivalent penetration to be used with this system was estimated to be 15 g/cm{sup 2}. The authors measured in-air lateral profiles at the isocenter plane and integral depth doses with the energy absorber. All input data were obtained by the Monte Carlo calculation, and its parameters were tuned to reproduce measurements. The fluence of single spots in water was modeled as a triple Gaussian function and the dose distribution was calculated using a fluence dose model. The authors compared in-air and in-water lateral profiles and depth doses between calculations and measurements for various apertures of square, half, and U-shaped fields. The absolute doses and dose distributions with the aperture were then validated by patient-specific quality assurance. Measured data were obtained by various chambers and a 2D ion chamber detector array. Results: The patient-specific aperture reduced the penumbra from 30% to 70%, for example, from 34.0 to 23.6 mm and 18.8 to 5.6 mm. The calculated field width for square-shaped apertures agreed with measurements within 1 mm. Regarding patient-specific aperture plans, calculated and measured doses agreed within −0.06% ± 0.63% (mean ± SD) and 97.1% points passed the 2%-dose/2 mm-distance criteria of the γ-index on average. Conclusions: The patient-specific aperture system improved dose distributions, particularly in shallow-region plans.

60 APPLIED LIFE SCIENCES↗

SU-C-204-02: Behavioral and Pathologic Differences in Mice Exposed to Proton Minibeam Arrays Versus Proton Broad Beams

Purpose: Minibeam therapy using protons or light-ions offers a theoretical reduction of biologic damage to tissues upstream of a tumor compared to broad-beam therapy while providing equal tumor control. The purpose of this study was to investigate behavioral and pathologic differences in mice after exposure of healthy brain to proton minibeam arrays versus proton broad beams. Methods: Twenty-four C57BL/6J juvenile mice were divided into 5 study arms: sham irradiation (NoRT), broad-beam 10 Gy (BB10), minibeam 10Gy (MB10), broad-beam 30 Gy (BB30), and minibeam 30 Gy (MB30), approximate integral entrance doses. Circular beams of 100 MeV protons with 7-mm diameter were delivered laterally through the brain, either as broad beams or as planar minibeam arrays having 300-micron beam width and 1-mm spacing on center. Mice were followed for 8 months using standard behavioral tests. Pathologic studies were carried out at 8 months after irradiation. Results: Peak entrance doses were 10.0, 23.8, 30.0, and 71.3 Gy for mice in BB10, MB10, BB30, and MB30, respectively. Despite the high single-fraction doses, no animals showed signs of radiation sickness or neurophysical impairment over the 8-month study duration. The Morris water maze alternate-starting-position trial showed significant evidence of better spatial learning for mice in MB10 versus BB10 (p=0.026), but other behavioral tests showed no significant differences. Glial fibrillary acidic protein stains showed gliosis in arms BB10, BB30, and MB30 but not in NoRT or MB10. A secondary finding was categorically higher epilation in broad-beam arms compared with their minibeam dose counterparts. Conclusion: Our findings indicate trends that, despite the higher peak doses, proton minibeam therapy can reduce radiation side effects in shallow tissue and brain compared to proton broadbeam therapy. As the behavioral findings were mixed, confirmation studies are needed with larger numbers of animals. AAPM Research Seed Funding Grant.

60 APPLIED LIFE SCIENCES↗

SU-F-T-162: Comparison of Beam Data for Two Varian ProBeam Pencil Beam Scanning Proton Systems

Purpose: To compare the beam data for proton spot scanning beams for the first two Varian ProBeam sites in the US at the Maryland Proton Treatment Center (MPTC) and Scripps Proton Therapy Center (Scripps). To investigate how well beams can be matched between rooms. Method: Beam data were acquired with independent dosimetry systems and compared for two sites. Integrated depth dose curves (IDDs) were acquired with large volume PTW Bragg peak chambers in a 3D water tank for pencil beams at both sites. Spot profiles were acquired at different distances from the isocenter at a gantry angle of 0 degrees as well as function of gantry angle. Results: IDDs for the two Varian ProBeam proton sites are similar, except in the plateau region were the Scripps data is on average 4.5% higher relative to each other, but only 1.5% relative to the maximum at the Bragg Peak. This increase in the plateau region decrease as energy increase and for energies larger than 180 MeV there is no marked difference. Range in water coincide for all energies within 0.5mm. The sigma of the spot profiles in air are within 10% of each other at isocenter. This difference increase as the detector distance from the isocenter is increased. Conclusion: Beam data of the Varian ProBeam proton spot scanning beams for two sites are very well matched. Differences will not be clinically relevant.

60 APPLIED LIFE SCIENCES↗