Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INLET FLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Improving the performance of a compression ignition engine by directing flow of inlet air

The object of this report is to present the results of tests performed by the National Advisory Committee for Aeronautics to determine the effect on engine performance of directing the flow of the inlet air to a 5-inch by 7-inch cylinder, solid injection, compression ignition engine, After a few preliminary tests, comparative runs were made at a speed of 1500 r.p.m. with and without directed air flow. It was found that directing the flow of the inlet air toward the fuel injection valve gave steadier engine operation, and an appreciable increase in power, and decreased fuel consumption. The results indicate the possibility of improving the performance of a given type of combustion chamber without changing its shape and with no change in valve timing. They would also seem to prove that directional turbulence, set up before the inlet valve of a four-stroke cycle engine, continues in the engine cylinder throughout the compression stroke.

Kemper, Carlton↗

Design Factors for Two-Dimensional, External-Compression Supersonic Inlets

Geometric and aerodynamic design factors were studied for the design of two-dimensional, external-compression inlets operating at a freestream Mach number of Mach 1.7. Computational simulations of the inlet flows were performed to obtain the inlet performance metrics consisting of the inlet flow rates, total pressure recovery, and total pressure distortion at the engine face. The key design factors identified included the external diffuser Mach number, cowl lip interior angle, bleed slot length, throat section aft centerbody slope, and subsonic diffuser length. Using the results of the Mach 1.7 inlet study, inlets were designed for Mach 1.4 and 2.0. The results provide useful insight on the significance of the design factors for the design of such inlets for commercial supersonic aircraft.

Slater, John W.↗

Prediction of compressor stall for distorted and undistorted flow by use of a multistage compressor simulation on the digital computer

A simulation technique is presented for the prediction of compressor stall for axial-flow compressors for clean and distorted inlet flow. The simulation is implemented on the digital computer and uses stage stacking and lumped-volume gas dynamics. The resulting nonlinear differential equations are linearized about a steady-state operating point, and a Routh-Hurwitz stability test is performed on the linear system matrix. Parallel compressor theory is utilized to extend the technique to the distorted inlet flow problem. The method is applied to the eight-stage J85-13 compressor.

Daniele, C. J.↗

Installation caused flow distortion and its effect on noise from a fan designed for turbofan engines

A ground test stand was used to obtain acoustic data on a full scale prototype fan designed for quiet subsonic aircraft engines. The fan was installed in three different ways in the test stand. In two of the installations the fan was driven by a shaft in the inlet; in the third installation the fan was driven from the rear. These three installations, and the structures associated with them, resulted in various amounts of inlet flow distortion to the fan. The rear drive installation had less inlet flow distortion than the two front drive installations. Some measurements of inlet flow distortion were made and used in a blade passage noise generation theory to predict the effects of distortion on noise. Good agreement was obtained when the predicted and measured power level differences between the front drive and rear drive installations were compared.

Povinelli, F. P.↗

Computational Assessment of a 3-Stage Axial Compressor Which Provides Airflow to the NASA 11- by 11-Foot Transonic Wind Tunnel, Including Design Changes for Increased Performance

A 24 foot diameter 3-stage axial compressor powered by variable-speed induction motors provides the airflow in the closed-return 11- by 11-Foot Transonic Wind Tunnel (11-Foot TWT) Facility at NASA Ames Research Center at Moffett Field, California. The facility is part of the Unitary Plan Wind Tunnel, which was completed in 1955. Since then, upgrades made to the 11-Foot TWT such as flow conditioning devices and instrumentation have increased blockage and pressure loss in the tunnel, somewhat reducing the peak Mach number capability of the test section. Due to erosion effects on the existing aluminum alloy rotor blades, fabrication of new steel rotor blades is planned. This presents an opportunity to increase the Mach number capability of the tunnel by redesigning the compressor for increased pressure ratio. Challenging design constraints exist for any proposed design, demanding the use of the existing driveline, rotor disks, stator vanes, and hub and casing flow paths, so as to minimize cost and installation time. The current effort was undertaken to characterize the performance of the existing compressor design using available design tools and computational fluid dynamics (CFD) codes and subsequently recommend a new compressor design to achieve higher pressure ratio, which directly correlates with increased test section Mach number. The constant cross-sectional area of the compressor leads to highly diffusion factors, which presents a challenge in simulating the existing design. The CFD code APNASA was used to simulate the aerodynamic performance of the existing compressor. The simulations were compared to performance predictions from the HT0300 turbomachinery design and analysis code, and to compressor performance data taken during a 1997 facility test. It was found that the CFD simulations were sensitive to endwall leakages associated with stator buttons, and to a lesser degree, under-stator-platform flow recirculation at the hub. When stator button leakages were modeled, pumping capability increased by over 20 of pressure rise at design point due to a large reduction in aerodynamic blockage at the hub. Incorporating the stator button leakages was crucial to matching test data. Under-stator-platform flow recirculation was thought to be large due to a lack of seals. The effect of this recirculation was assessed with APNASA simulations recirculating 0.5, 1, and 2 of inlet flow about stators 1 and 2, modeled as axisymmetric mass flux boundary conditions on the hub before and after the vanes. The injection of flow ahead of the stators tended to re-energize the boundary layer and reduce hub separations, resulting in about 3 increased stall margin per 1 of inlet flow recirculated. In order to assess the value of the flow recirculation, a mixing plane simulation of the compressor which gridded the under-stator cavities was generated using the ADPAC CFD code. This simulation indicated that about 0.65 of the inlet flow is recirculated around each shrouded stator. This collective information was applied during the redesign of the compressor. A potential design was identified using HT0300 which improved overall pressure ratio by removing pre-swirl into rotor 1, replacing existing NASA 65 series rotors with double circular arc sections, and re-staggering rotors and the existing stators. The performance of the new design predicted by APNASA and HT0300 is compared to the existing design.

Turbomachinery↗

Derivation and evaluation of an approximate analysis for three-dimensional viscous subsonic flow with large secondary velocities

An approximate analysis is presented for calculating three-dimensional, low Mach number, laminar viscous flows in curved passages with large secondary flows and corner boundary layers. The analysis is based on the decomposition of the overall velocity field into inviscid and viscous components with the overall velocity being determined from superposition. An incompressible vorticity transport equation is used to estimate inviscid secondary flow velocities to be used as corrections to the potential flow velocity field. A parabolized streamwise momentum equation coupled to an adiabatic energy equation and global continuity equation is used to obtain an approximate viscous correction to the pressure and longitudinal velocity fields. A collateral flow assumption is invoked to estimate the viscous correction to the transverse velocity fields. The approximate analysis is solved numerically using an implicit ADI solution for the viscous pressure and velocity fields. An iterative ADI procedure is used to solve for the inviscid secondary vorticity and velocity fields. This method was applied to computing the flow within a turbine vane passage with inlet flow conditions of M = 0.1 and M = 0.25, Re = 1000 and adiabatic walls, and for a constant radius curved rectangular duct with R/D = 12 and 14 and with inlet flow conditions of M = 0.1, Re = 1000, and adiabatic walls.

Anderson, O. L.↗

Analytical study of flow phenomena in SSME turnaround duct geometries

The SSME fuel turbopump hot gas manifold was identified as a source of loss and flow distortion which significantly affects the performance and durability of both the drive turbine and the LOX injector area of the main combustion chamber. Two current SSME geometries were studied, the full power level (FPL) and the first manned orbital flight (FMOF) configuration. The effects of turnaround duct geometry on flow losses and distortions, by varying wall curvature and flow area variation in the 180 deg turnaround region were examined. The effects of the duct inlet flow phenomena such as the radial distortion of the inlet flow and inlet swirl level on turnaround duct performance were also investigated. It is shown that of the two current geometries, the FMOF configuration had lower pressure losses and generated less flow distortion, but had a small flow separation bubble at the 180 deg turnaround exit. It is found that by optimizing wall curvature and flow diffusion in the turnaround, improved duct performance can be achieved.

Mclallin, K. L.↗

Inlet-fan flow field computation

The flow field of a tilt-nacelle inlet-fan combination used for V/STOL aircraft is studied. Under certain flight conditions the inlet is subjected to high angles of attack and/or yaw. This produces a non-uniform or distorted flow field at the fan-face that can lead to large blade stresses. This paper presents an analytical approach to the coupled inlet-fan problem. The nacelle is modelled by a distribution of source panels and the fan by a distribution of radial vortices. A modified actuator disc with losses and a quasi-steady rotor response is used to derive the boundary condition at the fan-face. An example of the calculation is shown.

Matwey, M. D.↗

Can Bump Arrays Separate Particles from Turbulent Flows?

In this paper, we evaluate the hypothesis that bump arrays can be used to separate particles from turbulent flows entering the array. Microfluidic bump arrays are known for separating particles by size from laminar inlet flows. However, turbulent inlet flows have not been explored but become important as microfluidic bump arrays are scaled up to mesofluidic bump arrays. We find experimentally that particle separation is indeed effective at higher Reynolds numbers. These experimental findings portend industrial scale particle separation due to the higher flow rates they facilitate.

Pease, Leonard F.↗

Active unsteady aerodynamic suppression of rotating stall in an incompressible flow centrifugal compressor with vaned diffuser

A mathematical model is developed to analyze the suppression of rotating stall in an incompressible flow centrifugal compressor with a vaned diffuser, thereby addressing the important need for centrifugal compressor rotating stall and surge control. In this model, the precursor to to instability is a weak rotating potential velocity perturbation in the inlet flow field that eventually develops into a finite disturbance. To suppress the growth of this potential disturbance, a rotating control vortical velocity disturbance is introduced into the impeller inlet flow. The effectiveness of this control is analyzed by matching the perturbation pressure in the compressor inlet and exit flow fields with a model for the unsteady behavior of the compressor. To demonstrate instability control, this model is then used to predict the control effectiveness for centrifugal compressor geometries based on a low speed research centrifugal compressor. These results indicate that reductions of 10 to 15 percent in the mean inlet flow coefficient at instability are possible with control waveforms of half the magnitude of the total disturbance at the inlet.

Lawless, Patrick B.↗

Experimental investigation of inlet flow-control cascades for the NFAC 80- by 120-foot Indraft Wind Tunnel

The present investigation of aerodynamic performance for various inlet cascade configurations of an indraft wind tunnel with a short inlet and a low contraction ratio has given attention to the effects of inlet wall shape, antiturbulence screens, and horizontal flow straighteners on test-section flow quality. It is found that an inlet cascade with a tailored vane-splay distribution, antiturbulence screen, and horizontal splitters, will both yield good test section flow quality and furnish isolation from atmospheric winds and turbulence.

Van Aken, Johannes M.↗

Fluidic Oscillator Having Decoupled Frequency and Amplitude Control

A fluidic oscillator having independent frequency and amplitude control includes a fluidic-oscillator main flow channel having a main flow inlet, a main flow outlet, and first and second control ports disposed at opposing sides thereof. A fluidic-oscillator controller has an inlet and outlet. A volume defined by the main flow channel is greater than the volume defined by the controller. A flow diverter coupled to the outlet of the controller defines a first fluid flow path from the controller's outlet to the first control port and defines a second fluid flow path from the controller's outlet to the second control port.

Koklu, Mehti↗

Fluidic Oscillator Having Decoupled Frequency and Amplitude Control

A fluidic oscillator having independent frequency and amplitude control includes a fluidic-oscillator main flow channel having a main flow inlet, a main flow outlet, and first and second control ports disposed at opposing sides thereof. A fluidic-oscillator controller has an inlet and outlet. A volume defined by the main flow channel is greater than the volume defined by the controller. A flow diverter coupled to the outlet of the controller defines a first fluid flow path from the controller's outlet to the first control port and defines a second fluid flow path from the controller's outlet to the second control port.

Koklu, Mehti↗

Effect of a rotating propeller on the separation angle of attack and distortion in ducted propeller inlets

The present study represents an extension of an earlier wind tunnel experiment performed with the P&W 17-in. Advanced Ducted Propeller (ADP) Simulator operating at Mach 0.2. In order to study the effects of a rotating propeller on the inlet flow, data were obtained in the UTRC 10- by 15-Foot Large Subsonic Wind Tunnel with the same hardware and instrumentation, but with the propeller removed. These new tests were performed over a range of flow rates which duplicated flow rates in the powered simulator program. The flow through the inlet was provided by a remotely located vacuum source. A comparison of the results of this flow-through study with the previous data from the powered simulator indicated that in the conventional inlet the propeller produced an increase in the separation angle of attack between 4.0 deg at a specific flow of 22.4 lb/sec-sq ft to 2.7 deg at a higher specific flow of 33.8 lb/sec-sq ft. A similar effect on separation angle of attack was obtained by using stationary blockage rather than a propeller.

Boldman, D. R.↗

Effect of a rotating propeller on the separation angle of attack

The present study represents an extension of an earlier wind tunnel experiment performed with the P&W 17-in. Advanced Ducted Propeller (ADP) Simulator operating at Mach 0.2. In order to study the effects of a rotating propeller on the inlet flow, data were obtained in the UTRC 10- by 15-Foot Large Subsonic Wind Tunnel with the same hardware and instrumentation, but with the propellar removed. These new tests were performed over a range of flow rates which duplicated flow rates in the powered simulator program. The flow through the inlet was provided by a remotely located vacuum source. A comparison of the results of this flow-through study with the previous data from the powered simulator indicated that in the conventional inlet the propeller produced an increase in the separation angle of attack between 4.0 deg at a specific flow of 22.4 lb/sec-sq ft to 2.7 deg at a higher specific flow of 33.8 lb/sec-sq ft. A similar effect on separation angle of attack was obtained by using stationary blockage rather than a propeller.

Boldman, D. R.↗

Internal flow characteristics of a multistage compressor with inlet pressure distortion

The measured distribution of compressor interstage pressures and temperatures resulting from a 180 deg inlet-total-pressure distortion for a J85-13 turbojet engine is reported. Extensive inner stage instrumentation combined with stepwise rotation of the inlet distortion gave data of high circumferential resolution. The steady-state pressures and temperatures along with the amplitude, extent, and location of the distorted areas are given. Data for 80, 90, and 100 percent of rotor design speed are compared with clean (undistorted) inlet flow conditions to show pressure and temperature behavior within the compressor. Both overall and stagewise compressor performances vary only slightly when clean and distorted inlet conditions are compared. Total and static pressure distortions increase in amplitude in the first few stages of the compressor and then attenuate fairly uniformly to zero at the discharge. Total-temperature distortion induced by the pressure distortion reached a maximum amplitude by the first two stages and decayed only a little through the rest of the compressor. Distortion amplitude tended to peak in line with the screen edges, and, except for total and static pressure in the tip zone, there was little swirl in the axial direction.

Debogdan, C. E.↗

Testing and Performance Verification of a High Bypass Ratio Turbofan Rotor in an Internal Flow Component Test Facility

A 1/5 scale model rotor representative of a current technology, high bypass ratio, turbofan engine was installed and tested in the W8 single-stage, high-speed, compressor test facility at NASA Glenn Research Center (GRC). The same fan rotor was tested previously in the GRC 9x15 Low Speed Wind Tunnel as a fan module consisting of the rotor and outlet guide vanes mounted in a flight-like nacelle. The W8 test verified that the aerodynamic performance and detailed flow field of the rotor as installed in W8 were representative of the wind tunnel fan module installation. Modifications to W8 were necessary to ensure that this internal flow facility would have a flow field at the test package that is representative of flow conditions in the wind tunnel installation. Inlet flow conditioning was designed and installed in W8 to lower the fan face turbulence intensity to less than 1.0 percent in order to better match the wind tunnel operating environment. Also, inlet bleed was added to thin the casing boundary layer to be more representative of a flight nacelle boundary layer. On the 100 percent speed operating line the fan pressure rise and mass flow rate agreed with the wind tunnel data to within 1 percent. Detailed hot film surveys of the inlet flow, inlet boundary layer and fan exit flow were compared to results from the wind tunnel. The effect of inlet casing boundary layer thickness on fan performance was quantified. Challenges and lessons learned from testing this high flow, low static pressure rise fan in an internal flow facility are discussed.

VanZante, Dale E.↗

High-temperature NMR MAS probe with optimized temperature gradient across sample rotor

A rotor housing assembly for NMR spectroscopy. An elongate rotor has a distal drive end, a proximal end and an internal sample space positioned along its length between the drive and proximal ends. The rotor is driveable about a rotation axis by a drive gas flow. A rotor housing has an interior space in which the rotor is at least partially received. At least one first heated gas flow inlet is positioned opposite the internal sample space, through which a first heated gas flow is controllably flowable into the interior space to heat it and the rotor. At least a pair of spaced apart second heated gas flow outlets are axially spaced from the first heated gas flow inlet to controllably convey a second heated gas flow to heat distal and proximal areas of the sample space to minimize a temperature gradient extending axially within the sample space.

Mehta, Hardeep S.↗