Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPLANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Physiological Stress Responses to Prolonged Exposure to MS-222 and Surgical Implantation in Juvenile Chinook Salmon

While many studies have investigated the effects of transmitters on fish condition, behavior, and survival, to our knowledge, no studies have taken into account anesthetic exposure time in addition to tag and surgery effects. We investigated stress responses to prolonged MS-222 exposure after stage 4 induction in surgically implanted juvenile Chinook salmon (Oncorhynchus tshawytscha). Survival, tag loss, plasma cortisol concentration, and blood Na + , K + , Ca 2+ , and pH were measured immediately following anesthetic exposure and surgical implantation and 1, 7, and 14 days post-treatment. Despite the prolonged anesthetic exposure, 3-15 minutes post Stage 4 induction, there were no mortalities or tag loss in any treatment. MS-222 was effective at delaying immediate cortisol release during surgical implantation; however, osmotic disturbances resulted, which were more pronounced in longer anesthetic time exposures. From day 1 to day 14, Na + , Ca 2+ , and pH significantly decreased, while cortisol significantly increased. The cortisol increase was exacerbated by surgical implantation. There was a significant interaction between MS-222 time exposure and observation day for Na + , Ca 2+ , K + , and pH; variations were seen in the longer time exposures, although not consistently. In conclusion, stress response patterns suggest stress associated with surgical implantation is amplified with increased exposure to MS-222.

59 BASIC BIOLOGICAL SCIENCES↗

Erbium-implanted materials for quantum communication applications

Erbium-doped materials can serve as spin-photon interfaces with optical transitions in the telecom C band, making them an exciting class of materials for long-distance quantum communication. However, the spin and optical coherence times of Er 3+ ions are limited by currently available host materials, motivating the development of new Er 3+ -containing materials. Here we demonstrate the use of ion implantation to efficiently screen prospective host candidates, and show that disorder introduced by ion implantation can be mitigated through post-implantation thermal processing to achieve inhomogeneous linewidths comparable to bulk linewidths in as-grown samples. We present optical spectroscopy data for each host material, which allows us to determine the level structure of each site, allowing us to compare the environments of Er 3+ introduced via implantation and via doping during growth. Here, we demonstrate that implantation can generate a range of local environments for Er 3+ , including those observed in bulk-doped materials, and that the populations of these sites can be controlled with thermal processing.

74 ATOMIC AND MOLECULAR PHYSICS↗

Ion Implanted Passivated Contacts for Interdigitated Back Contacted Solar Cells

We describe work towards an interdigitated back contacted (IBC) solar cell utilizing ion implanted, passivated contacts. Formation of electron and hole passivated contacts to n-type CZ wafers using tunneling SiO2 and ion implanted amorphous silicon (a-Si) are described. P and B were ion implanted into intrinsic amorphous Si films at several doses and energies. A series of post-implant anneals showed that the passivation quality improved with increasing annealing temperatures up to 900 degrees C. The recombination parameter, Jo, as measured by a Sinton lifetime tester, was Jo ~ 14 fA/cm2 for Si:P, and Jo ~ 56 fA/cm2 for Si:B contacts. The contact resistivity for the passivated contacts, as measured by TLM patterns, was 14 milliohm-cm2 for the n-type contact and 0.6 milliohm-cm2 for the p-type contact. These Jo and pcontact values are encouraging for forming IBC cells using ion implantation to spatially define dopants.

14 SOLAR ENERGY↗

SU-E-J-58: Dosimetric Verification of Metal Artifact Effects: Comparison of Dose Distributions Affected by Patient Teeth and Implants

Purpose: Implant-supported dentures seem particularly appropriate for the predicament of becoming edentulous and cancer patients are no exceptions. As the number of people having dental implants increased in different ages, critical dosimetric verification of metal artifact effects are required for the more accurate head and neck radiation therapy. The purpose of this study is to verify the theoretical analysis of the metal(streak and dark) artifact, and to evaluate dosimetric effect which cause by dental implants in CT images of patients with the patient teeth and implants inserted humanoid phantom. Methods: The phantom comprises cylinder which is shaped to simulate the anatomical structures of a human head and neck. Through applying various clinical cases, made phantom which is closely allied to human. Developed phantom can verify two classes: (i)closed mouth (ii)opened mouth. RapidArc plans of 4 cases were created in the Eclipse planning system. Total dose of 2000 cGy in 10 fractions is prescribed to the whole planning target volume (PTV) using 6MV photon beams. Acuros XB (AXB) advanced dose calculation algorithm, Analytical Anisotropic Algorithm (AAA) and progressive resolution optimizer were used in dose optimization and calculation. Results: In closed and opened mouth phantom, because dark artifacts formed extensively around the metal implants, dose variation was relatively higher than that of streak artifacts. As the PTV was delineated on the dark regions or large streak artifact regions, maximum 7.8% dose error and average 3.2% difference was observed. The averaged minimum dose to the PTV predicted by AAA was about 5.6% higher and OARs doses are also 5.2% higher compared to AXB. Conclusion: The results of this study showed that AXB dose calculation involving high-density materials is more accurate than AAA calculation, and AXB was superior to AAA in dose predictions beyond dark artifact/air cavity portion when compared against the measurements.

60 APPLIED LIFE SCIENCES↗

SU-E-T-546: Use of Implant Volume for Quality Assurance of Low Dose Rate Brachytherapy Treatment Plans

Purpose: To analyze the application of volume implant (V100) data as a method for a global check of low dose rate (LDR) brachytherapy plans. Methods: Treatment plans for 335 consecutive patients undergoing permanent seed implants for prostate cancer and for 113 patients treated with plaque therapy for ocular melanoma were analyzed. Plaques used were 54 COMS (10 to 20 mm, notched and regular) and 59 Eye Physics EP917s with variable loading. Plots of treatment time x implanted activity per unit dose versus v100 ^.667 were made. V100 values were obtained using dose volume histograms calculated by the treatment planning systems (Variseed 8.02 and Plaque Simulator 5.4). Four different physicists were involved in planning the prostate seed cases; two physicists for the eye plaques. Results: Since the time and dose for the prostate cases did not vary, a plot of implanted activity vs V100 ^.667 was made. A linear fit with no intercept had an r{sup 2} = 0.978; more than 94% of the actual activities fell within 5% of the activities calculated from the linear fit. The greatest deviations were in cases where the implant volumes were large (> 100 cc). Both COMS and EP917 plaque linear fits were good (r{sup 2} = .967 and .957); the largest deviations were seen for large volumes. Conclusions: The method outlined here is effective for checking planning consistency and quality assurance of two types of LDR brachytherapy treatment plans (temporary and permanent). A spreadsheet for the calculations enables a quick check of the plan in situations were time is short (e.g. OR-based prostate planning)

07 ISOTOPE AND RADIATION SOURCES↗

Poster — Thur Eve — 41: Considerations for Patients with Permanently Implant Radioactive Sources Requiring Unrelated Surgery

Permanent implant of sealed radioactive sources is an effective technique for treating cancer. Typically, the radioactive sources are implanted in and near the disease, depositing dose locally over several months. There may be instances where these patients must undergo unrelated surgical procedures when the radioactive material remains active enough to pose risks. This work explores these risks, discusses strategies to mitigate those risks, and describes a case study for a permanent I-125 prostate brachytherapy implant patient who developed colo-rectal cancer and required surgery 6 months after brachytherapy. The first consideration is identifying the risk from unwarranted radiation to the patient and staff before, during, and after the surgical procedure. The second is identifying the risk the surgical procedure may have on the efficacy of the brachytherapy implant. Finally, there are considerations for controlling for radioactive substances from a regulatory perspective. After these risks are defined, strategies to mitigate those risks are considered. These strategies may include applying the concepts of ALARA, the use of protective equipment and developing a best practice strategy with the operating room team. We summarize this experience with some guidelines: If the surgical procedure is near (ex: 5 cm) of the implant; and, the surgical intervention may dislodge radioisotopes enough to compromise treatment or introduces radiation safety risks; and, the radioisotope has not sufficiently decayed to background levels; and, the surgery cannot be postponed, then a detailed analysis of risk is advised.

60 APPLIED LIFE SCIENCES↗

Sci—Fri PM: Topics — 02: Evaluation of Dosimetric Variations in Partial Breast Seed Implant (PBSI) due to Patient Arm Position (Up vs. Down)

The planning for PBSI is done with the patient's ipsilateral arm raised, however, anatomical changes and variations are unavoidable as the patient resumes her daily activities, potentially resulting in significant deviations in implant geometry from the treatment plan. This study aims to quantify the impact of the ipsilateral arm position on the geometry and dosimetry of the implant at eight weeks, evaluated on post-plans using the MIM Symphony™ software (MIM Software, Cleveland, OH). The average dose metrics for the three patients treated at the TBCC thus far using rigid fusion and contour transfer for the arms up position were 76% for the CTV V100, 61% for the PTV V100, and 37% for the PTV V200; and for the arms down position 81% for the CTV V100, 64% for the PTV V100, and 42% for the PTV V200. Qualitative analysis of the post-implant CT for one of the three patients showed poor agreement between the seroma contour transferred from the pre-implant CT and the seroma visible on the post-implant CT. To obtain a clinically accurate plan for that patient, contour modifications were used, yielding improved dose metric averages for the arms-up position for all three patients of 87% for the CTV V100, 68% for the PTV V100, and 39% for the PTV V200. Overall, the data available shows that dosimetric parameters increase with the patient's arm down, both in terms of coverage and in terms of the hot spot, and accrual of more patients may confirm this in a larger population.

60 APPLIED LIFE SCIENCES↗

SU-D-207B-04: Morphological Features of MRI as a Correlate of Capsular Contracture in Breast Cancer Patients with Implant-Based Reconstructions

Purpose: Capsular contracture (CC) is a serious complication in patients receiving implant-based reconstruction for breast cancer. The goal of this study was to identify image-based correlates of CC using MRI imaging in breast cancer patients who received both MRI and clinical evaluation following reconstructive surgery. Methods: We analyzed a retrospective dataset of 50 patients who had both a diagnostic MR and a plastic surgeon’s evaluations of CC score (Baker’s score) within a six month period following mastectomy and reconstructive surgery. T2w sagittal MRIs (TR/TE = 3500/102 ms, slice thickness = 4 mm) were used for morphological shape features (roundness, eccentricity, solidity, extent and ratio-length) and histogram features (median, skewness and kurtosis) of the implant and the pectoralis muscle overlying the implant. Implant and pectoralis muscles were segmented in 3D using Computation Environment for Radiological Research (CERR) and shape and histogram features were calculated as a function of Baker’s score. Results: Shape features such as roundness and eccentricity were statistically significant in differentiating grade 1 and grade 2 (p = 0.009; p = 0.06) as well as grade 1 and grade 3 CC (p = 0.001; p = 0.006). Solidity and extent were statistically significant in differentiating grade 1 and grade 3 CC (p = 0.04; p = 0.04). Ratio-length was statistically significant in differentiating all grades of CC except grade 2 and grade 3 that showed borderline significance (p = 0.06). The muscle thickness, median intensity and kurtosis were significant in differentiating between grade 1 and grade 3 (p = 0.02), grade 1 and grade 2 (p = 0.03) and grade 1 and grade 3 (p = 0.01) respectively. Conclusion: Morphological shape features described on MR images were associated with the severity of CC. MRI may be important in objectively evaluating outcomes in breast cancer patients who undergo implant reconstruction.

60 APPLIED LIFE SCIENCES↗

SU-F-J-43: Positional Variation of Implanted Fiducial Markers Over the Course of Image Guided Radiotherapy for Pancreatic Cancer

Purpose: Pancreas is a soft-tissue organ, implanted fiducials can change positions due to migration or tissue deformation. This study quantified positional variation of fiducials in IGRT for pancreatic cancer. Methods: 20 patients had at least 3 gold fiducials implanted in pancreas under EUS guidance. Patients had 4D-CT simulation for gated treatment. Daily gated OBI kV images (Turebeam) were used for positional alignment with fiducials for total of 25 or 28 fractions. Relative distances among 3 fiducials (d{sub 1–} {sub 2}, d{sub 1–3}, d{sub 2–3}) were measured from 4D-CT end-of-expiration phase bin; and from gated kV images in first, mid, and last fraction (n=180). Results: The median duration between implant and simulation was 11 (range 0–41) days. The median duration between simulation and first fraction was 17 (range 8–24) days. The median relative distance was 12 (range 4–78) mm for d{sub 1–2}, 24 (range 6–80) mm for d{sub 1–3}, and 19 (range 5–63) mm for d{sub 2–3}. The median deviation was 1 mm for d{sub 1–2}, d{sub 1–3}, d{sub 2–3} between simulation and first fraction, first and mid fraction, mid and last fraction (n=180). Two patients (10%) had deviation >= 5 mm (5, 11 mm) between simulation and first fraction. One patient (5%) had deviation >= 5 mm (11 mm) between first and mid fraction. No patient (0%) had deviation >= 5 mm between mid and last fraction. In all 3 cases with deviation >=5 mm, only one fiducial was significantly deviated. No clear evidence that deviation size was associated with time interval between implant and first fraction. Conclusion: Implanted gold fiducials were quite stable over time in their relative positions in pancreas. Our data suggested at least 3 fiducials are needed. In cases that one fiducial was significantly deviated in daily kV images, this fiducial should be excluded in image guidance.

60 APPLIED LIFE SCIENCES↗

SU-F-T-314: Estimation of Dose Distributions with Different Types of Breast Implants in Various Radiation Treatment Techniques for Breast Cancer

Purpose: This study investigates the effects of different kinds and designs of commercialized breast implants on the dose distributions in breast cancer radiotherapy under a variety of conditions. Methods: The dose for the clinical conventional tangential irradiation, Intensity Modulated Radiation Therapy (IMRT), volumetric modulated arc therapy (VMAT) breast plans was measured using radiochromic films and stimulated luminescence dosimeter (OSLD). The radiochromic film was used as an integrating dosimeter, while the OSLDs were used for real-time dosimetry to isolate the contribution of dose from individual segment. The films were placed at various slices in the Rando phantom and between the body and breast surface OSLDs were used to measure skin dose at 18 positions spaced on the two (right/left) breast. The implant breast was placed on the left side and the phantom breast was remained on the right side. Each treatment technique was performed on different size of the breasts and different shape of the breast implant. The PTV dose was prescribed 50.4 Gy and V47.88≥95%. Results: In different shapes of the breast implant, because of the shadow formed extensive around the breast implant, dose variation was relatively higher that of prescribed dose. As the PTV was delineated on the whole breast, maximum 5% dose error and average 3% difference was observed averagely. VMAT techniques largely decrease the contiguous hot spot in the skin by an average of 25% compared with IMRT. The both IMRT and VMAT techniques resulted in lower doses to normal critical structures than tangential plans for nearly all dose analyzation. Conclusion: Compared to the other technique, IMRT reduced radiation dose exposure to normal tissues and maintained reasonable target homogeneity and for the same target coverage, VMAT can reduce the skin dose in all the regions of the body.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRA-12: Post-Implant Dosimetry in Prostate Brachytherapy by X-Ray and MRI Fusion

Purpose: For post-implant dosimetric assessment after prostate brachytherapy, CT-MR fusion approach has been advocated due to the superior accuracy on both seeds localization and soft tissue delineation. However, CT deposits additional radiation to the patient, and seed identification in CT requires manual review and correction. In this study, we propose an accurate, low-dose, and cost-effective post-implant dosimetry approach based on X-ray and MRI. Methods: Implanted seeds are reconstructed using only three X-ray fluoroscopy images by solving a combinatorial optimization problem. The reconstructed seeds are then registered to MR images using an intensity-based points-to-volume registration. MR images are first pre-processed by geometric and Gaussian filtering, yielding smooth candidate seed-only images. To accommodate potential soft tissue deformation, our registration is performed in two steps, an initial affine followed by local deformable registrations. An evolutionary optimizer in conjunction with a points-to-volume similarity metric is used for the affine registration. Local prostate deformation and seed migration are then adjusted by the deformable registration step with external and internal force constraints. Results: We tested our algorithm on twenty patient data sets. For quantitative evaluation, we obtained ground truth seed positions by fusing the post-implant CT-MR images. Seeds were semi-automatically extracted from CT and manually corrected and then registered to the MR images. Target registration error (TRE) was computed by measuring the Euclidean distances from the ground truth to the closest registered X-ray seeds. The overall TREs (mean±standard deviation in mm) are 1.6±1.1 (affine) and 1.3±0.8 (affine+deformable). The overall computation takes less than 1 minute. Conclusion: It has been reported that the CT-based seed localization error is ∼1.6mm and the seed localization uncertainty of 2mm results in less than 5% deviation of prostate D90. The average error of 1.3mm with our system outperforms the CT-based approach and is considered well within the clinically acceptable limit. Supported in part by NIH/NCI grant 5R01CA151395. The X-ray-based implant reconstruction method (US patent No. 8,233,686) was licensed to Acoustic MedSystems Inc.

60 APPLIED LIFE SCIENCES↗

Effect of Boron Impurity on the Light-Emitting Properties of Dislocation Structures Formed in Silicon by Si{sup +} Ion Implantation

The effect of boron implantation on the light-emitting properties of dislocation structures formed in silicon by Si{sup +} ion implantation with subsequent annealing is studied. It is shown that the implantation of B{sup +} ions has a significant effect on the dislocation-related luminescence intensity, spectrum and the temperature dependence of the D1-band intensity. It is found that the temperature dependence is nonmonotonous and involves two regions, in which the D1-band intensity increases with increasing temperature and has two well-pronounced maxima at 20 K and 60–70 K. The maximum at 20 K is associated with the morphological features of the dislocation structure under study, whereas the maximum at 60–70 K is associated with the additional implantation of the boron impurity into the dislocation region of the samples. It is established that the intensities of the experimentally observed maxima and the position of the high-temperature maximum depend on the implanted boron concentration.

36 MATERIALS SCIENCE↗

XAFS Investigation of Nanoparticle Formation in {sup 64}Zn{sup +} Ion Implanted and Thermo Oxidized Si

The single crystal CZ n-Si(100) substrates with electron concentration n{sub o} = 5 × 10{sup 16} cm{sup −3} were implanted by {sup 64}Zn{sup +} ions with dose of 5 × 10{sup 16} cm{sup −2} and energy of 50 keV. During implantation the ion beam current density was less than 0.5 μA/cm{sup 2} to avoid the substrate magnetically heating. After implantation, the plates were subjected to isochronous for one hour heat treatment in oxygen atmosphere at temperatures from 400 up to 1000{sup o}C with a step of 100{sup o}C. Zn K-edge EXAFS spectra were measured in fluorescent mode. Si(111) channel-cut monochromator was used for energy scanning; energy resolution ΔE/E = 2 × 10{sup –4}. According to Zn K-edge EXAFS data, all Zn implanted in Si at 900{sup o}C is fully oxidized: an absolute maximum of EXAFS Fourier transform at R ~ 1.6 Å corresponds to Zn–O distance. Based on XANES data, we suggest an interaction between implanted Zn atoms and Si support.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Defect Structure of GaAs Layers Implanted with Nitrogen Ions

Structural defects formed in epitaxial GaAs layers as a result of 250-keV N{sup +} ion implantation to doses within 5 × 10{sup 14}–5 × 10{sup 16} cm{sup –2} have been studied by the X-ray diffraction (XRD) and transmission electron microscopy techniques. No amorphization of the ion-implanted layer took place in the entire dose range studied. The implantation to doses of 5 × 10{sup 14} and 5 × 10{sup 15} cm{sup –2} led to the appearance of an additional peak on XRD curves, which was related to the formation of a stressed GaAs layer with positive deformation arising due to the formation of point-defect clusters. The implantation to a dose of 5 × 10{sup 16} cm{sup –2} led to the formation of a dense structure of extended defects in the implanted layer, which was accompanied by the relaxation of macrostresses to the initial state.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Robotic Nipple-Sparing Mastectomy and Immediate Breast Reconstruction with Gel Implant: Technique, Preliminary Results and Patient-Reported Cosmetic Outcome

Background: Experience with application of a robotic surgery platform in the management of breast cancer is limited. The preliminary results of the robotic nipple-sparing mastectomy (R-NSM) and immediate breast reconstruction (IBR) with Gel implant procedure are reported. Methods: The medical records of patients from a single institution who underwent an R-NSM and IBR with Gel implant procedure for breast cancer during the period March 2017 to February 2018 were assessed. Data on clinicopathologic characteristics, type of surgery, complications, and recurrence were analyzed to determine the effectiveness and oncologic safety of R-NSM. Patient-reported cosmetic outcome results were obtained. Results: A total of 22 patients who received 23 R-NSM and IBR with Gel implant procedures were analyzed. The mean operation time for R-NSM was 118.8 ± 50.6 min, and 74.5 ± 26.6 min for Gel implant reconstruction. Docking time quickly dropped from 20 to 6–8 min, and the time needed to complete R-NSM was usually completed within 100 min after accumulation of case experience. Mean blood loss was 37 ± 38.2 mL, and the positive surgical margin rate was 0%. Three (13%) patients had transit nipple ischemia change, and no total nipple-areolar complex necrosis cases were observed. No local recurrence or mortality was found during a mean 6.9 ± 3.5 months of follow-up. All 22 patients were satisfied with the postoperative aesthetic outcome. Conclusion: From our preliminary experience, R-NSM and IBR with Gel implant is a safe procedure, with good cosmetic results, and could be a promising new technique for breast cancer patients indicated for mastectomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigating Helium Bubble Nucleation and Growth through Simultaneous In-Situ Cryogenic, Ion Implantation, and Environmental Transmission Electron Microscopy

Palladium can readily dissociate molecular hydrogen at its surface, and rapidly accept it onto the octahedral sites of its face-centered cubic crystal structure. This can include radioactive tritium. As tritium β-decays with a half-life of 12.3 years, He-3 is generated in the metal lattice, causing significant degradation of the material. Helium bubble evolution at high concentrations can result in blister formation or exfoliation and must therefore be well understood to predict the longevity of materials that absorb tritium. A hydrogen over-pressure must be applied to palladium hydride to prevent hydrogen from desorbing from the metal, making it difficult to study tritium in palladium by methods that involve vacuum, such as electron microscopy. Recent improvements in in-situ ion implantation Transmission Electron Microscopy (TEM) allow for the direct observation of He bubble nucleation and growth in materials. In this work, we present results from preliminary experiments using the new ion implantation Environmental TEM (ETEM) at the University of Huddersfield to observe He bubble nucleation and growth, in-situ, in palladium at cryogenic temperatures in a hydrogen environment. After the initial nucleation phase, bubble diameter remained constant throughout the implantation, but bubble density increased with implantation time. β-phase palladium hydride was not observed to form during the experiments, likely indicating that the cryogenic implantation temperature played a dominating role in the bubble nucleation and growth behavior.

36 MATERIALS SCIENCE↗

High–Yield Deterministic Focused Ion Beam Implantation of Quantum Defects Enabled by In Situ Photoluminescence Feedback

Focused ion beam implantation is ideally suited for placing defect centers in wide bandgap semiconductors with nanometer spatial resolution. However, the fact that only a few percent of implanted defects can be activated to become efficient single photon emitters prevents this powerful capability to reach its full potential in photonic/electronic integration of quantum defects. Here an industry adaptive scalable technique is demonstrated to deterministically create single defects in commercial grade silicon carbide by performing repeated low ion number implantation and in situ photoluminescence evaluation after each round of implantation. An array of 9 single defects in 13 targeted locations is successfully created—a ≈70% yield which is more than an order of magnitude higher than achieved in a typical single pass ion implantation. The remaining emitters exhibit non-classical photon emission statistics corresponding to the existence of at most two emitters. This approach can be further integrated with other advanced techniques such as in situ annealing and cryogenic operations to extend to other material platforms for various quantum information technologies.

36 MATERIALS SCIENCE↗

Direct Synthesis of Layer-Tunable and Transfer-Free Graphene on Device-Compatible Substrates Using Ion Implantation Toward Versatile Applications

Direct synthesis of layer-tunable and transfer-free graphene on technologically important substrates is highly valued for various electronics and device applications. State of the art in the field is currently a two-step process: a high-quality graphene layer synthesis on metal substrate through chemical vapor deposition (CVD) followed by delicate layer transfer onto device-relevant substrates. Here, we report a novel synthesis approach combining ion implantation for a precise graphene layer control and dual-metal smart Janus substrate for a diffusion-limiting graphene formation to directly synthesize large area, high quality, and layer-tunable graphene films on arbitrary substrates without the post-synthesis layer transfer process. Carbon (C) ion implantation was performed on Cu–Ni film deposited on a variety of device-relevant substrates. A well-controlled number of layers of graphene, primarily monolayer and bilayer, is precisely controlled by the equivalent fluence of the implanted C-atoms (1 monolayer ~4 × 10 15 C-atoms/cm 2 ). Upon thermal annealing to promote Cu-Ni alloying, the pre-implanted C-atoms in the Ni layer are pushed toward the Ni/substrate interface by the top Cu layer due to the poor C-solubility in Cu. As a result, the expelled C-atoms precipitate into a graphene structure at the interface facilitated by the Cu-like alloy catalysis. After removing the alloyed Cu-like surface layer, the layer-tunable graphene on the desired substrate is directly realized. The layer-selectivity, high quality, and uniformity of the graphene films are not only confirmed with detailed characterizations using a suite of surface analysis techniques but more importantly are successfully demonstrated by the excellent properties and performance of several devices directly fabricated from these graphene films. Molecular dynamics (MD) simulations using the reactive force field (ReaxFF) were performed to elucidate the graphene formation mechanisms in this novel synthesis approach. With the wide use of ion implantation technology in the microelectronics industry, this novel graphene synthesis approach with precise layer-tunability and transfer-free processing has the promise to advance efficient graphene-device manufacturing and expedite their versatile applications in many fields.

36 MATERIALS SCIENCE↗