Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hourly Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

U.S. Industrial and Commercial Motor System Market Assessment Report. Volume 3: Energy Saving Opportunity

This report seeks to inform the potential for motor systems to support decarbonization by estimating their potential energy, electricity cost, and CO 2 emissions reduction potential from adoption of proven energy efficiency actions and advanced technologies. This is the third and final report in a series of reports disseminating the findings of the U.S. Department of Energy’s (DOE’s) Motor System Market Assessment (MSMA). The MSMA and this report focus on polyphase motor systems greater than or equal to 1 horsepower (hp) in the industrial and commercial sectors. In the U.S. Industrial and Commercial Motor System Market Assessment Report Volume 1: Characteristics of the Installed Base (Volume 1 report), it was determined that these motor systems consume more than 1,000 terawatt-hours (TWh) annually. This equates to 29% of the U.S. electric grid load and results in 765 million metric tons (MMT) of CO 2 emissions and $166 billion in electricity costs. This report finds that substantial reductions to these energy, cost, and emissions impacts are possible, with three areas of significant opportunity being (1) improved load matching, (2) replacing older inefficient motors with more efficient motors, and (3) improving the condition of fluid (e.g., air, water, compressed air) distribution systems. A summary of the savings potential from these three opportunities placed within the context of the overall consumption for motor systems is illustrated in Figure ES 1 (industrial) and Figure ES 2 (commercial).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assessing the performance of global thermostat adjustment in commercial buildings for load shifting demand response

Abstract Efficiently leveraging new sources of flexibility is critical to mitigating load balancing challenges posed by variable renewable resources. The thermal inertia of commercial buildings allows us to shift their power consumption on minute to hourly timescales to provide demand response to the grid while maintaining occupant comfort. Global thermostat adjustment (GTA) provides a readily available and scalable approach for implementing load shifting demand response using commercial heating, ventilation, and air conditioning (HVAC) systems, since it leverages the inherent sophistication of modern building automation systems. However, there is an incomplete understanding of GTA’s performance for this purpose and its impact on building systems and occupant comfort. In this paper, we explore the performance of GTA by analyzing results from nearly nine hundred experiments on eight university campus buildings in Michigan and North Carolina. Using GTA, we manipulate each building’s thermostat setpoints causing the building to shift its power consumption with respect to its baseline. We quantify the magnitude of HVAC power response, energy use of HVAC subsystems, and impact on occupant comfort. Finally, we connect our experimental results with power system operation using an optimization model that coordinates GTA actions across a large collection of grid-interactive efficient buildings (GEBs) to reduce high ramp rates on the grid and mitigate renewable energy curtailment. Overall, our work finds that the impacts on HVAC subsystems are often complex, and may result in additional energy being consumed by fans and terminal reheat. These effects must be considered when using GTA for load shifting. Additionally, we demonstrate that occupant comfort, as assessed by indoor temperature and humidity, can be maintained during GTA events. From a societal perspective, our modeling work finds that the additional renewable energy that can be integrated through the use of GTA strategies eclipses any additional energy consumed by buildings.

Keskar, Aditya (ORCID:0000000244617980)↗

Evaluating the Grid Impact of Oregon Offshore Wind [Slides]

This analysis used high-resolution offshore wind data and a detailed production cost model (PCM) of the Western Interconnection to explore the value and operational impact of integrating offshore wind along Oregon's coastline. Leveraging local technical stakeholder expertise and input, we determined a set of scenarios to explore. These scenarios vary both offshore wind capacities and the Western Interconnection generation and transmission infrastructure. From the scenario modeling and analysis, we identified the following key findings. In addition, we simulated a subset of the scenarios for a range of historical weather years (2007-2013), to understand the robustness of our findings to different weather conditions. Trans-coastal transmission constraints and congestion are the key drivers to the curtailment of Oregon offshore wind. Once power can be delivered into the Willamette Valley, there are few system constraints that lead to a significant curtailment of offshore wind off the coast of Oregon. Approximately 2.6 GW of installed offshore wind capacity can be integrated into Oregon's power system without major upgrades to trans-coastal transmission while avoiding significant curtailment. The system value provided by offshore wind ranges between $\$65$ /MWh and $\$85$ /MWh across the various scenarios considered. Offshore wind heavily influences the flow of the cross Cascade transmission. Across all scenarios, we found a robust relationship of approximately 500-550 MW decrease in the hourly flow of the cross Cascade transmission for every 1,000 MW of hourly offshore wind generation. However, we also found there was not a strong relationship between the highest cross-Cascade transmission flow hours and high offshore wind generation, limiting the extent to which offshore wind can be considered a non-wires alternative to cross cascade transmission. Depending on the meteorological year, 880-1,580 MW and 1,650-3,100 MW can be counted on to serve coastal loads with 2.6 GW and 5 GW of offshore wind capacity, respectively. Offshore wind allows for more optimal daily and hourly scheduling of hydropower, while still complying with various technical and regulatory constraints on the water resource. Oregon offshore wind has the potential to contribute to the evening net load peak in California (i.e., mitigate duck curve challenges), however transmission congestion between California and Oregon limits this contribution. Co-located storage at the point of interconnection for offshore wind reduces curtailment when trans-coastal transmission is not upgraded, providing a non-wires alternative to increase offshore wind capacity beyond 2.6 GW.

17 WIND ENERGY↗

Futures for electrochromic windows on high performance houses in arid, cold climates

This study investigates high performance electrochromic windows used on a passive house and residential dwelling to IECC 2021 (i.e., IECC dwelling). In the lab, the electrochromic film switches transmitted solar heat gain coefficient (SHGC) from 0.09 to 0.7 and visible transmittance from 0.15 to 0.82 with power consumption of 1.23 W/m 2 during switching times less than 3 minutes. We extrapolate these results to a window assembly. Building energy models of the houses were evaluated in Santa Fe, New Mexico. A Monte Carlo analysis for 2020, 2040, 2060, and 2080 was conducted for Shared Socioeconomic Pathways 2-4.5, 3-7.0, and 5-8.5. Cases with and without the electrochromic windows and with and without electricity were used to determine energy use intensity and hours beyond thermal safety thresholds. The passive house showed 1.3-3.1% mean energy savings and the IECC dwelling 4.4-5.1% with electrochromic efficiency benefits growing into the future for both cases. Even so, overall savings decrease into the future for the passive house, due to growth in cooling load being dominant, conversely overall energy savings increase into the future for the IECC dwelling due to heating loads being dominant. For thermal resilience, the passive house exhibited a mean percent decrease of 0.02-0.31% hours in the extreme caution (i.e., > 32.2 °C, ≤ 39.4 °C) range while the IECC dwelling exhibited 0.38-4.38%. The study therefore shows that electrochromic windows will have smaller benefits for the passive house in comparison to the IECC dwelling. The relationship between electrochromic windows is shown to have a complex relationship between house efficiency and climate change by these results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy, power, and infrastructure demands from electrifying airport ground support equipment at United States airports

As the airline industry seeks to reduce costs and transition to clean energy, electric ground support equipment is emerging as a favorable option. The integration of electric ground support equipment into airport operations requires careful planning for vehicle deployment, charging infrastructure, and grid impacts. We develop a flexible, bottom-up modeling framework to assess energy and infrastructure needs across more than 300 U.S. airports. Our analysis estimates site-specific power and energy demand, equipment counts by type, charger requirements, and costs. Here we quantify the magnitude of new electrical loads created by the electrification of airport ground support equipment, finding that peak power demand at the largest airports can reach up to 20 megawatts, with annual electricity consumption approaching 51,000 megawatt-hours. We further show that behind-the-meter battery energy storage systems and solar photovoltaic systems can reduce peak load and lower total system costs by as much as 10 million dollars.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Marine Hydrokinetic Tidal Turbine

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset is part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with other energy technologies. This dataset contains inputs and outputs from simulations of a floating marine hydrokinetic turbine over approximately half a tidal cycle (~6.6 hours). Inflow conditions were derived from field measurements in Alaska’s Cook Inlet and represent a tidal environment in which the current speed ramps from near 0 m/s to a peak of 3 m/s and back. The original acoustic doppler current profiler dataset is publicly available on the Marine and Hydrokinetic Data Repository. In a full tidal cycle, the flow reverses and the rotor would reorient; this reversal was not modeled. In the Cook Inlet campaign , turbulence intensity was similar in both directions. Two inflow cases are included. In the first case, labeled “raw” in the files, the measured current time series was used directly in the InflowWind module of OpenFAST. Speed and direction were applied as a function of time and elevation, uniformly in the horizontal direction. With full spatial coherence, this approach captures high turbulent variability and results in pronounced power fluctuations, so it is considered a conservative, near-worst-case representation of loading. In the second case, labeled “average” in the files, a 30-minute moving average was applied to extract the slowly varying mean speed. The residual fluctuations about this mean were used to generate spatially varying, full-field turbulence inputs with TurbSim, giving a more physically realistic representation of the inflow across the rotor disk. Two random realizations were used to produce distinct inflow conditions for two OpenFAST simulations representing a two-turbine array. The same turbulence intensity is applied across the full time series, producing larger fluctuations at the start and end, where the mean speed is low. The second case is the more appropriate framework for performance and power assessment but overpredicts turbulence at lower flow speeds and underpredicts it at higher speeds. As the floating platform moves and the rotor changes its x-position, Taylor’s frozen turbulence hypothesis used by InflowWind assumes a constant rather than a time-varying mean velocity, introducing some inaccuracy in the velocity plane sampling. The turbine modeled is the 500-kW Reference Model 1, a horizontal-axis two-bladed hydrokinetic turbine on a four-column floating semisubmersible substructure . Simulations were performed using OpenFAST v4.1 with the Reference Open Source Controller (ROSCO) v2.10. All input files required to reproduce the simulations are included. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel . This unit supports up to 2.5 MW, but NLR has only a single 1.25-MW stack. The datasets report hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. The system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operating current of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The simulated tidal turbine time series data was translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz. Each zip file represents a single tidal electrolysis experiment and is named: {technology}_{inflow method}_{number of 500 kW tidal turbines connected} For instance, “tidal-500kW-RM1_average_2.zip” is a 6-hour experiment using the 500-kW tidal reference model, scaled by 2x (1-MW) to better match the electrolyzer maximum of 1.25MW, fed with the 30-minute moving average current case. Each zip folder contains the following files: A .csv file of raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. A .csv file combines all tidal profiles as "combined_tidal_experiments.csv." A separate experiment, “characterization_200.zip,” shows the MC250 electrolyzer steady-state response with 30-minute load steps over 5 hours and is accessible with this entry.

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Wave

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wave energy conversion device. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen. While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the wave energy, NLR used a wave energy converter model from PacWave. These devices can be equipped with accumulators and pressure relief values to smooth the power output by storing and releasing hydraulic energy. Using a peak power output of 10 MW, the model created two 25-minute profiles: one with and one without the accumulators and pressure relief valves. To down select the profile data from the native resolution of 20 Hz to 1 Hz, NLR took the mean of every 20 data points. NLR experimented with two simulated wave energy power plants: one that peaks at 10 MW, and one that peaks at 5 MW. These profiles were scaled for the physical 1.25 MW electrolyzer by multiplying the original profiles by one eighth and one quarter, respectively. The first profile matches the capacity rating of eight of the 1.25 MW electrolyzers, while the second matches four electrolyzers. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wave electrolysis experiment and is formatted as follows: {technology}-{accumulator?}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “wavePacWave-Noacc_4-400.zip” represents the 25 minute-long experiment using the PacWave’s wave energy converter model, equipped with no accumulator, connected to four 1.25-MW electrolyzers with their power supplies set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. An experiment, labeled “characterization_200.zip”, demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all wave profiles combined into one dataset labeled "combined_wave_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis.

08 HYDROGEN↗

Datasets for Widespread Residential Space Heating Electrification in Texas

In this experiment, we explore long term patterns in electricity demand driven by the dual effects of full electrification of space heating in Texas (by adoption of electric heat pumps), and climate change. We use a predictive model of electricity demand, climate projections, and an open source nodal power system (DC Optimal Power Flow) model of the Electric Reliability Council of Texas (ERCOT) system. Heat pumps are a more energy efficient way of providing space heating and cooling in homes. We attempt to exhaustively investigate the impacts of full residential space heating electrification by adoption of heat pumps for the segment of Texas households that currently rely on fossil fuels (about 40%), while simultaneously incorporating climate change meteorological variables. We explore a range of scenarios of heat pump efficiency and climate uncertainty over a long period of future years (2020-2099). In total, the simulation experiment generates 1,280 simulation years of hourly data. We report and analyze results in form of impacts on residential load, total load, peak load, seasonality of peaking, and reliability measured by occurrence and frequency of loss of load events. While the experiment is for ERCOT, the insights and approach can be applied to other regions. The results from the analysis can inform system planners on a range of potential capacity requirements/ reliability implications and/or risks of full space heating electrification via the adoption of electric heat pumps, given the uncertainty in the scenarios/ climate futures. The dataset includes model output for residential, non residential and total load, and the results from the GO ERCOT model runs for 4 RCP Scenarios (RCP 4.5 Cooler, RCP 4.5 Hotter, RCP 8.5 Cooler, RCP 8.5 Hotter), 4 Heating electrification Scenarios (Base , Standard Efficiency HP, High Efficiency HP, Ultra-High Efficiency HP) over 80 years (2020-2099). The metrological variables at BA scale were weighted weighted using population projections consistent with the SSP3 scenario.

Climate Change↗

End Use Load Profile (EULP) of US Building Sector resulting from mass GHP retrofits

This collection of datasets describes the change (difference) in hourly energy consumption of the U.S. residential and commercial building stock while replacing existing HVAC systems with ground source heat pumps for all the balancing areas in the US, for all buildings eligible for ground source heat pump replacement. Additional county-level data may be requested from the DOE Project Lead.

15 GEOTHERMAL ENERGY↗

Plug-and-play polymer microfluidic chips for hydrated, room temperature, fixed-target serial crystallography

The practice of serial X-ray crystallography (SX) depends on efficient, continuous delivery of hydrated protein crystals while minimizing background scattering. Of the two major types of sample delivery devices, fixed-target devices offer several advantages over widely adopted jet injectors, including: lower sample consumption, clog-free delivery, and the ability to control on-chip crystal density to improve hit rates. In this study we present our development of versatile, inexpensive, and robust polymer microfluidic chips for routine and reliable room temperature serial measurements at both synchrotrons and X-ray free electron lasers (XFELs). Our design includes highly X-ray-transparent enclosing thin film layers tuned to minimize scatter background, adaptable sample flow layers tuned to match crystal size, and a large sample area compatible with both raster scanning and rotation based serial data collection. The optically transparent chips can be used both for in situ protein crystallization (to eliminate crystal handling) or crystal slurry loading, with prepared samples stable for weeks in a humidified environment and for several hours in ambient conditions. Serial oscillation crystallography, using a multi-crystal rotational data collection approach, at a microfocus synchrotron beamline (SSRL, beamline 12-1) was used to benchmark the performance of the chips. Furthermore, high-resolution structures (1.3–2.7 Å) were collected from five different proteins – hen egg white lysozyme, thaumatin, bovine liver catalase, concanavalin-A (type VI), and SARS-CoV-2 nonstructural protein NSP5. Overall, our modular fabrication approach enables precise control over the cross-section of materials in the X-ray beam path and facilitates chip adaption to different sample and beamline requirements for user-friendly, straightforward diffraction measurements at room temperature.

59 BASIC BIOLOGICAL SCIENCES↗

Hybridization Assessment of Trybrid Pumped Storage Hydropower System—Part 1: A Case Study of Corral Summit

This report is a part of the deliverables for technical assistance provided to Cat Creek Energy for the Coral Summit Trybrid (Triple Hybrid-Pumped Storage Hydropower, Battery Energy Storage System, and photovoltaic solar energy) energy project. This report explores the operational benefits and challenges of hybridizing an open loop PSH (200MW) located at Mackay, Custer County, Idaho with solar PV (Ground mount 300MW and floating 40MW) and battery (720MWhr). This document reports two activities performed as a part of the hybridization assessment task 1) optimal resource allocation and energy management strategy, and 2) power quality and reliability assessment. From optimal resource allocation and energy management strategy (activity 1), the following key findings can be observed: • Conventional PSH (CPSH) with two reversible pump turbines and separate penstocks can provide required flexibility equivalent to that from two ternary PSH with separate penstock. With single unit CPSH, upper reservoir head cannot be maintained accurately, the variation of water level is rapid and pump mode flexibility is not available. These disadvantages can be overcome by single unit TPSH. However, using two CPSH units with separate penstocks also overcome these disadvantages with the formation of the hydraulic short circuit between two conventional units. • Flooding of the lower reservoir is a severe concern when considering continuous operation for black start. This limits the duration of continuous operation from PSH alone to around 50 hours. Due to the complementary PV and battery action, the duration of continuous operation and smooth power output can be extended. • An optimization problem is framed that maximizes the power output on an hourly basis while minimizing constraint violations and respecting seasonal variations of solar PV and load profiles . Two value streams, arbitrage and baseload generation are served by this profile. It was uncovered that for smooth power output during regular operation, PV curtailment will be required, or the battery capacity needs to be increased above 90MW to accommodate additional PV. From power quality and reliability assessment (activity 2) the following takeaway points can be observed: • The Trybrid, when integrated at the Lost River bus, and limited to 250MW in generation mode and -150MW in the pump mode, causes no violation of voltage or flow.

13 - HYDRO ENERGY↗

Influence of Thermal Energy Storage Integration Strategy on System Performance and Refrigerant Charge for Small-Scale R290 Heat Pumps

As small-scale (2.5 – 5 kW) heat pumps across the US increase straining the grid during peak hours, integrated heat pump thermal energy storage (HP-TES) systems can assist by load shifting. However, challenges arise when assembling these systems, as direct refrigerant-phase change material (PCM) heat exchangers (HXs) increase refrigerant charge, and indirect secondary loops degrade HP-TES performance. In this work, direct and indirect HP-TES configurations were sized using commercially available HXs to compare the available load shift time and performance at similar refrigerant charges. For the same indirect 5 kW HP-TES refrigerant charge, directly HP-TES can operate up to 72 and 145 minutes in cooling and heating modes, respectively, using small diameter tubes. Using Modelica, COP increases for direct and indirect HP-TES were 22% and 9%, respectively, given the parasitic losses in the indirect HP-TES. Overall, small-scale direct HP-TES can have comparable refrigerant charges with indirect HP-TES maximizing COP improvements.

25 ENERGY STORAGE↗

From Pollutant Removal to Renewable Energy: MoS2-Enhanced P25-Graphene Photocatalysts for Malathion Degradation and H2 Evolution

The widespread presence of pesticides—especially malathion—in aquatic environments presents a major obstacle to conventional remediation strategies, while the ongoing global energy crisis underscores the urgency of developing renewable energy sources such as hydrogen. In this context, photocatalytic water splitting emerges as a promising approach, though its practical application remains limited by poor charge carrier dynamics and insufficient visible-light utilization. Herein, we report the design and evaluation of a series of TiO2-based ternary nanocomposites comprising commercial P25 TiO2, reduced graphene oxide (rGO), and molybdenum disulfide (MoS2), with MoS2 loadings ranging from 1% to 10% by weight. The photocatalysts were fabricated via a two-step method: hydrothermal integration of rGO into P25 followed by solution-phase self-assembly of exfoliated MoS2 nanosheets. The composites were systematically characterized using X-ray diffraction (XRD), Raman spectroscopy, transmission electron microscopy (TEM), UV-Vis diffuse reflectance spectroscopy (DRS), and photoluminescence (PL) spectroscopy. Photocatalytic activity was assessed through two key applications: the degradation of malathion (20 mg/L) under simulated solar irradiation and hydrogen evolution from water in the presence of sacrificial agents. Quantification was performed using UV-Vis spectroscopy, gas chromatography–mass spectrometry (GC-MS), and thermal conductivity detection (GC-TCD). Results showed that the integration of rGO significantly enhanced surface area and charge mobility, while MoS2 served as an effective co-catalyst, promoting interfacial charge separation and acting as an active site for hydrogen evolution. Nearly complete malathion degradation (~100%) was achieved within two hours, and hydrogen production reached up to 6000 µmol g−1 h−1 under optimal MoS2 loading. Notably, photocatalytic performance declined with higher MoS2 content due to recombination effects. Overall, this work demonstrates the synergistic enhancement provided by rGO and MoS2 in a stable P25-based system and underscores the viability of such ternary nanocomposites for addressing both environmental remediation and sustainable energy conversion challenges.

Chemistry↗

Reducing Grid Costs while Abating Emissions: Opportunities for Flexible Building Loads

This study evaluates the value of technology-agnostic, shiftable flexible building loads in modeled 2030 and 2040 U.S. grids for four types of customers under three potential aggregated distributed energy resources programs. The value examined includes monetary value from providing grid services (e.g., energy, capacity, flexibility reserve, regulation reserve, contingency reserve) and from reducing greenhouse gas emissions. By comparing more than 845,164,800 simulated shifting opportunities, the study finds that the timing of consumption is critical for profit-driven customers. A program that is activated for 30 critical hours of system operation can result in to $73 per year in revenue for 1 kWh of shiftable load. Emission reduction, on the other hand, is best accumulated through a year-round program: 1 kWh of shiftable load can lead to up to 487.9 kg CO2e carbon reduction per year. The report also provides detailed insights on the trade-off between revenue and emissions, regional variation, short- versus medium- term value, and impacts from various building flexibility parameters, such as shifting window and dissipation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermophysical properties of the Ghareb formation relevant for nuclear waste disposal

The Ghareb formation, a shallowly buried porous chalk in Israel, is currently a candidate for nuclear waste disposal. The potential repository is somewhat unique for its host rock and emplacement in shallow (500 m) engineered large diameter boreholes. Herein, the thermal properties of the Ghareb are determined to support design and performance assessment; the relevant properties measured are thermal conductivity, specific heat capacity, thermal diffusivity, and thermal expansion coefficient along with their relationship with varying temperature. For the temperature range of 40 to 275 °C, the thermal conductivity ranges from 0.30 to 1.10 W/m·K, the thermal diffusivity ranges from 0.20 to 0.72 mm 2 /s, and volumetric heat capacity ranges from 0.86 to 2.00 MJ/m 3 ·K. Thermal strain measurements were used to estimate the linear thermal expansion coefficient to be 6·10 –4 –9·10 –2 °C -1 from 40 to 300 °C. These measured properties were used in a thermomechanical model to estimate near-field stresses an hour and 10 years after waste emplacement; the borehole was found to be stable. Thermal loading after 10 years was predicted to elevate local pore pressures by 1–1.5 MPa. The laboratory measurements coupled with analyses are the first attempts at performance assessment characterization for this first of its kind potential repository setting with this chosen host rock.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

HP-FLEX: Field demonstration of the semantics-driven configuration of a Model Predictive Control system to make heat pumps flexible

Model Predictive Control (MPC) has demonstrated significant potential for optimizing building operations and enabling demand flexibility. However, the widespread adoption of MPC is hindered by complex manual configuration and commissioning processes that must be conducted by control experts working alongside building operators. These challenges drive up costs and reduce scalability, particularly when technical human resources and building automation systems are limited, such as in small and medium commercial buildings (SMCBs). This paper demonstrates how semantic standards, specifically ASHRAE 223P, can accelerate the adoption of MPC applications for load flexibility in SMCBs. The authors present a replicable control framework, titled “HP-FLEX” that leverages a building’s semantic model to bootstrap the required data configuration for an MPC controller developed for optimizing heat pump systems as flexible grid resources. The semantic model helps streamline the deployment workflow, particularly for site setup, data/control commissioning, and model setup. This integration enhances portability, transferability, and scalability of the HP-FLEX MPC, which has been developed to support MPC-based supervisory HVAC controllers in SMCBs. Additionally, the paper details the required building and thermostat metadata information to enable the HP-FLEX MPC based on field demonstrations. The new workflow was tested in a small commercial building located in California, U.S., and demonstrated a load shifting performance of 9% based on a dynamic pricing signal that varies by the hour. This work provides a practical pathway for transitioning sophisticated building applications from custom to standardized semantic representations, supporting the broader adoption of advanced control strategies like MPC. The framework also establishes a foundation for evolving metadata requirements as applications mature while maintaining compatibility with industry standards.

Paul, Lazlo↗

HP-FLEX: Field Demonstration of the Semantics-Driven Configuration of a Model Predictive Control System to Make Heat Pumps Flexible

Model Predictive Control (MPC) has demonstrated significant potential for optimizing building operations and enabling demand flexibility. However, the widespread adoption of MPC is hindered by complex manual configuration and commissioning processes that must be conducted by control experts working alongside building operators. These challenges drive up costs and reduce scalability, particularly when technical human resources and building automation systems are limited, such as in small and medium commercial buildings (SMCBs). This paper demonstrates how semantic standards, specifically ASHRAE 223P, can accelerate the adoption of MPC applications for load flexibility in SMCBs. The authors present a replicable control framework, titled “HP-FLEX” that leverages a building’s semantic model to bootstrap the required data configuration for an MPC controller developed for optimizing heat pump systems as flexible grid resources. The semantic model helps streamline the deployment workflow, particularly for site setup, data/control commissioning, and model setup. This integration enhances portability, transferability, and scalability of the HP-FLEX MPC, which has been developed to support MPC-based supervisory HVAC controllers in SMCBs. Additionally, the paper details the required building and thermostat metadata information to enable the HP-FLEX MPC based on field demonstrations. The new workflow was tested in a small commercial building located in California, U.S., and demonstrated a load shifting performance of 9% based on a dynamic pricing signal that varies by the hour. This work provides a practical pathway for transitioning sophisticated building applications from custom to standardized semantic representations, supporting the broader adoption of advanced control strategies like MPC. The framework also establishes a foundation for evolving metadata requirements as applications mature while maintaining compatibility with industry standards.

Paul, Lazlo↗

Operating Strategies for Dispatchable PEM Electrolyzers that Enable Low-Cost Hydrogen Production

Hydrogen is a pathway to enabling decarbonization across multiple economic sectors that cannot be directly decarbonized with electricity including heat for industrial operations, medium- and heavy-duty transportation applications, long-duration energy storage, and as a feedstock for chemical synthesis. Producing hydrogen at low costs and carbon footprint is likely essential to economically decarbonize these otherwise "hard to decarbonize" sectors. Low-temperature polymer electrolyte membrane (PEM) electrolysis produces hydrogen from water and electricity and is a rapidly developing pathway towards making hydrogen at the scales required for decarbonization applications. The levelized cost of electrolytic hydrogen is dependent on the capital cost, efficiency, and durability of the electrolyzer system as well as the price of electricity supplied to the electrolyzer and the annual utilization of the electrolyzer (capacity factor). Electricity price and capacity factor depend on the source of energy that the system uses and impact other economic factors. Electricity price and capacity factor and the connections between other aspects of hydrogen production via PEM electrolyzers are the focus of this work. PEM electrolyzers have conventionally been operated at high capacity factors using electricity purchased from utilities with a constant price throughout the year. To achieve lower effective electricity prices, recent work has investigated opportunities for electrolyzers to purchase electricity in wholesale markets, where the cost of electricity varies hourly. This option can lead to lower electricity costs when the electrolyzer is a controllable load that ramps up and down rapidly and turns on and off frequently. This configuration and operating strategy capitalizes on times of low wholesale electricity prices and results in lower hydrogen levelized costs than constant operation due to reduced electricity costs even though the reduced capacity factor increases the cost of recovering the capital investment. Cycling on and off frequently also has implications for electrolyzer durability. An electrolyzer configuration where it is directly connected to renewable generation such as wind or solar, only running when the generator is producing energy, has similar implications on operating strategy, hydrogen levelized cost, capacity factor, and durability. This work provides insight into the relationships between dispatchable electrolyzer operating strategies and the cost of producing hydrogen from these systems, outlining strategies and opportunities to minimize production costs while minimizing operations that are likely to negatively impact system durability and efficiency. We find strategies that minimize electrolyzer cycling and the resulting durability impacts while increasing the hydrogen levelized cost only slightly above the minimum. We also find opportunities for batteries to minimize the number of cycles in systems directly connected to renewable generation. These findings outline key opportunities for future electrolyzer deployments and the synergistic benefits between electrolyzers and increased deployment of renewable energy generation like wind and solar. They also inform research and development that is reducing electrolyzer capital cost while managing durability impacts.

electricity markets↗