Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GaSe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

The Flow of Gases in Narrow Channels

Measurements were made of the flow of gases through various narrow channels a few microns wide at average pressures from 0.00003 to 40 cm. Hg. The flow rate, defined as the product of pressure and volume rate of flow at unit pressure difference, first decreased linearly with decrease in mean pressure in the channel, in agreement with laminar-flow theory, reached a minimum when the mean path length was approximately equal to the channel width, and then increased to a constant value. The product of flow rate and square root of molecular number was approximately the same function of mean path length for all gases for a given channel.

FLOW, LAMINAR↗

Emissions of sulfur gases from wetlands

Data on the emissions of sulfur gases from marine and freshwater wetlands are summarized with respect to wetland vegetation type and possible formation mechanisms. The current data base is largest for salt marshes inhabited by Spartina alterniflora. Both dimethyl sulfide (DMS) and hydrogen sulfide (H2S) dominate emissions from salt marshes, with lesser quantities of methyl mercaptan (MeSH), carbonyl sulfide (COS), carbon disulfide (CS2) and dimethyl disulfide (DMDS) being emitted. High emission rates of DMS are associated with vegetation that produces the DMS precursor dimethylsulfonionpropionate (DMSP). Although large quantities of H2S are produced in marshes, only a small percentage escapes to the atmosphere. High latitude marshes emit less sulfur gases than temperate ones, but DMS still dominates. Mangrove-inhabited wetlands also emit less sulfur than temperate S. alterniflora marshes. Few data are available on sulfur gas emissions from freshwater wetlands. In most instances, sulfur emissions from temperate freshwater sites are low. However, some temperate and subtropical freshwater sites are similar in magnitude to those from marine wetlands which do not contain vegetation that produces DMSP. Emissions are low in Alaskan tundra but may be considerably higher in some bogs and fens.

Hines, Mark E.↗

Emissions of biogenic sulfur gases from northern bogs and fens

Sulfur gases are important components of the global cycle of S. They contribute to the acidity of precipitation and they influence global radiation balance and climate. The role of terrestrial sources of biogenic S and their effect on atmospheric chemistry remain as major unanswered questions in our understanding of the natural S cycle. The role of northern wetlands as sources and sinks of gaseous S by measuring rates of S gas exchange as a function of season, hydrologic conditions, and gradients in tropic status was investigated. Experiments were conducted in wetlands in New Hampshire, particularly a poor fen, and in Mire 239, a poor fen at the Experimental Lakes Area (ELA) in Ontario. Emissions were determined using Teflon enclosures, gas cryotrapping methods and gas chromatography (GC) with flame photometric detection. Dynamic (sweep flow) and static enclosures were employed which yielded similar results. Dissolved S gases and methane were determined by gas stripping followed by GC.

Demello, William Zamboni↗

Are the C delta light nitrogen and noble gases located in the same carrier?

Light nitrogen and the HL family noble gas components of C(sub delta) appear to be separable by high resolution pyrolysis experiments. Thus C(sub delta) is not a homogeneous material and probably consists of debris of many stars. The question of whether the N and Xe(HL) actually reside in different carriers continues to be addressed. It is well known that C(sub delta) which was identified as nanometer sized diamonds contains isotopically anamalous elements, in particular noble gases including Xe(HL) and its family and light nitrogen (delta(N-15) down to -350 percent). Before the true nature of C(sub delta) was recognized, it was easy to suppose that the Xe(HL) and light nitrogen were located in the same carrier. However, recognition that light nitrogen in diamond from different samples varies by greater than a factor of six compared to Xe(HL) fluctuations of ca. 20 percent makes such an assumption questionable. On the basis of simple arithmetic logic, the Xe and nitrogen cannot be absolutely co-located. The average diamond grain consists of only about 1000-2000 atoms of carbon; one grain among a few x 10(exp 6) contains an atom of Xe(HL) while 5-30 atoms of light nitrogen are the typical number which need to be in every diamond grain to account for observed concentrations. If some grains are devoid of N, the others have to have a higher N concentration. Even if we were able to analyze an individual grain of the diamond for noble gases and nitrogen, we would be faced with the monumental task of locating the one amongst 10(exp 6) identical grains containing the Xe atom to examine its nitrogen content. The problem can be simplified to some extent if instead of Xe, He which is 10(exp 4) times more abundant is assumed to be a member of the HL family. Attempts to fractionate the separate carriers might be attempted using He and N as guiding indicators but even experiments of this nature are for the future. Faced with apparently insoluble problems, we have returned to an investigation we last used in our original efforts to find isotopically light nitrogen, that is to compare release patterns of the different components during stepped pyrolysis and combustion.

Verchovsky, A. B.↗

Supersonic minimum length nozzle design for dense gases

Recently, dense gases have been investigated for many engineering applications such as for turbomachinery and wind tunnels. Supersonic nozzle design for these gases is complicated by their nonclassical behavior in the transonic flow regime. In this paper a method of characteristics (MOC) is developed for two-dimensional (planar) and, primarily, axisymmetric flow of a van der Waals gas. Using a straight aortic line assumption, a centered expansion is used to generate an inviscid wall contour of minimum length. The van der Waals results are compared to previous perfect gas results to show the real gas effects on the flow properties and inviscid wall contours.

Aldo, Andrew C.↗

Column amounts of trace gases from ground based FTIR measurements in the late north polar winters 1990 and 1991

Two FTIR spectrometers were employed in the late winters 1990 and 1991 in Esrange, North Sweden, and in Ny Aalesund, Spitsbergen to detect zenith column amounts of several trace gases. Time series of column amounts of the trace gases O3, N2O, CH4, HNO3, NO2, CHl, and HF have been derived from the measured spectra. Additionally, some information on the vertical distribution of HCl could be obtained by analyzing the spectral line shapes. The results are interpreted in terms of dynamical and chemical processes.

Adrian, Gabriele↗

Solubilities of nitrogen and noble gases in basalt melt

Nitrogen and noble gases are important tracers in geochemistry and chosmochemistry. Compared to noble gases, however, physicochemical properties of nitrogen, such as solubility in melt or melt/silicate partition, are not well known. Solubility of nitrogen in basalt melt depends on redox condition of the atmosphere. For example, solubility of nitrogen in E chondrite melt under reducing conditions is as high as 2 mol percent at 1500 C, suggesting that nitrogen is chemically dissolved in silicate melts, i.e., being dissolved as free anions or replacing oxygen sites in silicate network. However, the solubility and the dissolution mechanism of nitrogen under oxidizing conditions are not well investigated. To obtain nitrogen solubility in silicate melts under various redox conditions and to understand its mechanism, we are conducting experiments by using (15)N(15)N-labeled nitrogen gas. This makes it easy to distinguish dissolved nitrogen from later contamination of atmospheric nitrogen, and hence enables us to measure the nitrogen solubility accurately. As a preliminary experiment, we have measured solubility of nitrogen in basalt melt under the atmospheric oxygen pressure.

Miyazaki, A.↗

Implications of noble gases in a recently recognized Martian meteorite (ALH84001) for the degassing history of Mars

For terrestrial planets, atmospheric compositions are not static, but evolve with time, in part due to degassing of the interior. Unfortunately, the evolution is slow enough that it is usually not observable on human timescales, or even on the timescales of rocks that preserve samples of Earth's ancient atmosphere. Preliminary results on a recently recognized Martian meteorite, ALH84001, indicate that it is a very old rock, and has a relatively high noble gas content suggestive of atmospheric incorporation, but with an isotopic composition slightly inconsistent with currently known Martian reservoirs. Hence, this rock may provide a sample of ancient Martian atmosphere, which can be used to test models of volatile evolution (in particular, degassing) on Mars. ALH84001 is a cumulate orthopyroxenite. Although originally classified as a diogenite, its oxygen isotopes, and several chemical and petrographic features, strong suggest that it is, like the SNC meteorites, Martian. A Sm-Nd crystallization age of 4.5 Ga has been reported. The meteorite is rich in noble gases, compared to most SNC's. In many respects the noble gases are typical of SNC meteorites. However, there are some subtle differences. In particular, the Xe isotopes in SNC meteorites can be explained as a mixture of Martian atmospheric Xe (as represented by glass in EETA 79001), the Xe in the dunite Chassigny (usually assumed to be representative of the Martian interior, and with lower (129)Xe/(132)Xe, (134)Xe/(132)Xe and (136)Xe/(132)Xe ratios), and later additions from known processes like fission, spallation and terrestrial contamination. The isotopic composition of ALH84001 is inconsistent (at greater than 2-3 sigma) with any mixture of those components. Even if no accumulation of fission Xe during the age of the rock is assumed, there is too little (136)Xe and (134)Xe for the amount of (129)Xe measured.

Swindle, T. D.↗

Noble gases in presolar diamonds II: Component abundances reflect thermal processing

Using the isotopic compositions derived in Huss and Lewis, 1994a, abundances of the P3, HL, and P6 noble-gas components were determined for 15 diamonds separates from primitive chondrites of 8 chondrite classes. Within a meteorite class, the relative abundances of these components correlate with the petrologic subtype of the host meteorite, indicating that metamorphism is primarily responsible for the variations. Relative abundances of P3, HL, and P6 among diamond samples can be understood in terms of thermal processing of a single mixture of diamonds like those now found in CI and CM2 chondrites. With relatively gentle heating, primitive diamonds first lose their low-temperature P3 gases and a 'labile' fraction of the HL component. Mass loss associated with release of these components produces an increase in the HL and P6 content of the remaining diamond relative to unprocessed diamond. Higher temperatures initiate destruction of the main HL carrier, while the HL content of the surviving diamonds remains essentially constant. At the same time, the P6 carrier begins to preferentially lose light noble gases. Meteorites that have experienced metamorphic temperatures greater than or = 650 C have lost essentially all of their presolar diamond through chemical reactions with surrounding minerals. The P3 abundance seems to be a function only of the maximum temperature experienced by the diamonds and thus is independent of the nature of the surrounding environment. If all classes inherited the same mixture of primitive diamonds, then P3 abundances would tie together the metamorphic scales in different meteorite classes. However, if the P3 abundance indicates a higher temperature than do other thermometers applicable to the host meteorite, then the P3 abundance may contain information about heating prior to accretion. Diamonds in the least metamorphosed EH, CV, and CO chondrites seem to carry a record of pre-accretionary thermal processing.

Huss, Gary R.↗

Reevaluation of the NOAA/CMDL carbon monoxide reference scale and comparisons with CO reference gases at NASA-Langley and the Fraunhofer Institut

The carbon monoxide (CO) reference scale created by the National Oceanic and Atmospheric Administration/Climate Monitoring and Diagnostics Laboratory (NOAA/CMDL) is used to quantify measurements of CO in the atmosphere, calibrate standards of other laboratories and to otherwise provide reference gases to the community measuring atmospheric CO. This reference scale was created based upon a set of primary standards prepared by gravimetric methods at CMDL and has been propagated to a set of working standards. In this paper we compare CO mixing ratios assigned to the working standards by three approaches: (1) calibration against the original gravimetric standards, (2) calibration using only working standards as the reference gas, and (3) calibration against three new gravimetric standards prepared to CMDL. The agreement between these values was typically better than 1%. The calibration histories of CMDL working standards are reviewed with respect to expected rates of CO change in the atmosphere. Using a Monte Carlo approach to simulate the effect of drifting standards on calculated mixing ratios, we conclude that the error solely associated with the maintenance of standards will limit the ability to detect small CO changes in the atmosphere. We also report results of intercalibration experiments conducted between CMDL and the Diode Laser Sensor Group (DACOM) at the NASA Langley Research Center (Hampton, Virginia), and CMDL and the Fraunhofer-Institut (Garmisch-Partenkirchen, Germany). Each laboratory calibrated several working standards for CO using their reference gases, and these results were compared to calibrations conducted by CMDL. The intercomparison of eight standards (CO concentrations between approximately 100 and approximately 165 ppb) by CMDL and NASA agreed to better than +/- 2%. The calibration of six standards (CO concentrations between approximately 50 and approximately 210 ppb) by CMDL and the Fraunhofer-Institut agreed to within +/- 2% for four standards, and to within +/- 5% for all six standards.

Novelli, P. C.↗

Optical remote sensing for measurement of toxic gases

There is renewed interest in using optical remote sensing techniques for measuring and monitoring airborne toxins. Many instruments have been used to measure traces of atmospheric molecular species. Some optical remote sensing technology is in use for measuring or monitoring toxic or pollutant gases. The examples in this article provide a number of lessons that may be of use in the new field of optical remote sensing of toxic gases. Topics covered include the following: atmospheric properties, Fourier transform spectrometry, gas-filter correlation, differential absorption laser systems, aircraft missions, laser long-path instruments, differential optical absorption spectrometry, and ozone measurement.

Grant, William B.↗

Helmet-Mounted Display Of Clouds Of Harmful Gases

Proposed helmet-mounted opto-electronic instrument provides real-time stereoscopic views of clouds of otherwise invisible toxic, explosive, and/or corrosive gas. Display semitransparent: images of clouds superimposed on scene ordinarily visible to wearer. Images give indications on sizes and concentrations of gas clouds and their locations in relation to other objects in scene. Instruments serve as safety devices for astronauts, emergency response crews, fire fighters, people cleaning up chemical spills, or anyone working near invisible hazardous gases. Similar instruments used as sensors in automated emergency response systems that activate safety equipment and emergency procedures. Both helmet-mounted and automated-sensor versions used at industrial sites, chemical plants, or anywhere dangerous and invisible or difficult-to-see gases present. In addition to helmet-mounted and automated-sensor versions, there could be hand-held version. In some industrial applications, desirable to mount instruments and use them similarly to parking-lot surveillance cameras.

Diner, Daniel B.↗

Switch Box For Controlling Flows Of Four Gases

Switch box designed for use in simultaneously controlling flows of as many as four out of total of six available gases into semiconductor-processing chamber. Contains switches, relays, logic circuitry, display devices, and other circuitry for connecting each of as many as four gas controllers to any one of as many as six available mass-flow controllers. Front panel of switch box apprises technician of statuses of flows of various gases.

Wishard, James R.↗

Enhanced Boiling-Metal Cooling Of Vanes Exposed To Hot Gases

Incorporation of automatic, self-powered jet pumps proposed to enhance boiling-liquid-metal cooling of vanes exposed to hot gases. In original intended application, vanes and probes thrust-vector-control devices inserted in supersonic flows of hot gases in rocket-engine nozzles; this cooling concept also applicable to vanes and blades in high-performance turbine engines. In further improvement, additional axial and transverse slots added to coolant passages in vane or probe and to coolant reservoir. Slots reduce stresses caused by thermal expansion and contraction of solid coolant.

Osofsky, I. B.↗

Hydrophobic Catalysts For Removal Of NOx From Flue Gases

Improved catalysts for removal of nitrogen oxides (NO and NO2) from combustion flue gases formulated as composites of vanadium pentoxide in carbon molecular sieves. Promotes highly efficient selective catalytic reduction of NOx at relatively low temperatures while not being adversely affected by presence of water vapor and sulfur oxide gases in flue gas. Apparatus utilizing catalyst of this type easily integrated into exhaust stream of power plant to remove nitrogen oxides, generated in combustion of fossil fuels and contribute to formation of acid rain and photochemical smog.

Sharma, Pramod K.↗

Analyzing Gases From Decomposing Electrical Insulation

Test fixture holds insulated wire and traps gases emitted by heating of wire. Used with gas chromatograph and/or mass spectrometer, to analyze gases emitted by insulation on wire when wire heated with controlled current in controlled atmosphere to simulate pyrolysis, combustion, and arc tracking. Small, inexpensive, easily maintained, and relatively nonreactive to organic compounds produced during breakdown of insulation.

Moffett, Gary↗

Isotopic Analysis and Evolved Gases

Precise measurements of the chemical, elemental, and isotopic composition of planetary surface material and gases, and observed variations in these compositions, can contribute significantly to our knowledge of the source(s), ages, and evolution of solar system materials. The analyses discussed in this paper are mostly made by mass spectrometers or some other type of mass analyzer, and address three broad areas of interest: (1) atmospheric composition - isotopic, elemental, and molecular, (2) gases evolved from solids, and (3) solids. Current isotopic data on nine elements, mostly from in situ analysis, but also from meteorites and telescopic observations are summarized. Potential instruments for isotopic analysis of lunar, Martian, Venusian, Mercury, and Pluto surfaces, along with asteroid, cometary and icy satellites, surfaces are discussed.

Swindle, Timothy D.↗

Isotopic Composition of Trapped and Cosmogenic Noble Gases in Several Martian Meteorites

Isotopic abundances of the noble gases were measured in the following Martian meteorites: two shock glass inclusions from EET79001, shock vein glass from Shergotty and Y793605, and whole rock samples of ALH84001 and QUE94201. These glass samples, when combined with literature data on a separate single glass inclusion from EET79001 and a glass vein from Zagami, permit examination of the isotopic composition of Ne, Ar, Kr, and Xe trapped from the Martian atmosphere in greater detail. The isotopic composition of Martian Ne, if actually present in these glasses, remains poorly defined. The Ar-40/Ar-36 ratio of Martian atmospheric Ar may be much less than the ratio measured by Viking and possibly as low as approx. 1900. The atmospheric Ar-36/Ar-38 ratio is less than or equal to 4.0. Martian atmospheric Kr appears to be enriched in lighter isotopes by approx. 0.4%/amu compared to both solar wind Kr and to the Martian composition previously reported. The Martian atmospheric Ar-36/Xe-132 and Kr-84/Xe-132 Xe elemental ratios are higher than those reported by Viking by factors of approx. 3.3 and approx. 2.5, respectively. Cosmogenic gases indicate space exposure ages of 13.9 +/- 1 Myr for ALH84001 and 2.7 +/- 0.6 Myr for QUE94201. Small amounts of Ne-21 produced by energetic solar protons may be present in QUE94201, but are not present in ALH84001 or Y793605. The space exposure age for Y793605 is 4.9 +/- 0.6 Myr and appears to be distinctly older than the ages for basaltic shergottites.

Garrison, Daniel H.↗