Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GWP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Stover Harvest did not Change Nitrous Oxide Emissions in Two Minnesota Fields

Corn (Zea mays L.) is grown across vast acreages producing massive quantities of stover making corn a desirable cellulosic bioenergy feedstock. Nitrous oxide (N 2 O) is a potent greenhouse gas (GHG) so small changes in direct soil N 2 O emissions may have substantial influence on global warming potential (GWP) from the agricultural sector. Harvesting stover alters soil properties such as soil moisture, oxygen availability, temperature, and substrate availability (C and N). Thus, harvesting stover might reduce soil N 2 O emissions by reducing substrate and by warming and drying the soil. The goal of the study was to determine how harvesting corn stover altered soil N 2 O emissions. Therefore, soil N 2 O emissions were measured for four crop-years (planting to planting) in two independent studies, one in a field managed without tillage (NT1995) and the other was in a field tilled annually with a chisel plow (Chisel). In this study, each field was in a corn–soybean (Glycine max L. [Merr.]) rotation, with (i) corn grain (Grain) only, (ii) grain plus about 50% of the stover harvested (Grain+Moderate), and (iii) grain plus harvesting as much stover as possible (Grain+Aggressive) treatments. Cumulative soil N 2 O emissions did not differ among treatments in either field during any of the crop-years monitored. Flux events occurred corresponding to fertilizer applications and to spring freeze-thaw events. Cumulative fertilizer stimulated emissions tended to be greater for corn than soybean because of N-fertilizer application. These results are valuable to modelers for enhancing estimates of the N 2 O component of the stover management C-footprint.

54 ENVIRONMENTAL SCIENCES↗

Electrochemical CO2 conversion to formic acid through the Andora Process

Electrochemical utilization or conversion of CO2 can be used to convert waste CO2 into targeted high-value and cost-effective commercial products. Conventional processes for CO2 conversion to fuel sources are challenging and expensive due to their requirement for high temperatures and pressures. Electrochemically, a catalyst can be used at a fixed applied potential to reduce CO2 to form a desired product with less competition at modest operating conditions. Formic acid (FA) has recently become a product of interest for CO2 conversion due to its potential for hydrogen storage and fuel cell applications. Electrochemically, FA is produced through a direct two-electron transfer process involving CO2 with a proton source, requiring less energy input and fewer reaction steps than traditional processes. However, there remain significant obstacles for the broader-scale implementation of CO2 on the market, including competition with unwanted CO and H, the presence of molecular oxygen, and stability of the electrocatalyst. In order to overcome some of these challenges, a new continuous flow Andora Process was developed consisting of two separate cells to decouple electrochemical reduction of the charge carrier with the FA production via an engineered catalyst. Recent experimental results show that with appropriate design changes and operating conditions to the flow system, FA production above 500 mM can be achieved along with efficiencies above 80%. TEA and LCA assessments of the Andora Process show a potential for the reduction in the GWP potential and cost saving compared to the current comparative formic acid production process.

60 APPLIED LIFE SCIENCES↗

Final Report for SERDP Project RC-1649: Advanced Chemical Measurements of Smoke from DoD-prescribed Burns

Objectives: Project RC-1649, “Advanced Chemical Measurement of Smoke from DoD-prescribed Burns” was undertaken to use advanced instrumental techniques to study in detail the particulate and vapor-phase chemical composition of the smoke that results from prescribed fires used as a land management tool on DoD bases, particularly bases in the southeastern U.S. The statement of need (SON) called for “(1) improving characterization of fuel consumption” and “(2) improving characterization of air emissions under both flaming and smoldering conditions with respect to volatile organic compounds, heavy metals, and reactive gases.” The measurements and fuels were from several bases throughout the southeast (Camp Lejeune, Ft. Benning, and Ft. Jackson) and were carried out in collaboration and conjunction with projects 1647 (models) and 1648 (particulates, SW bases). Technical Approach: We used an approach that featured developing techniques for measuring biomass burning emission species in both the laboratory and field and developing infrared (IR) spectroscopy in particular. Using IR spectroscopy and other methods, we developed emission factors (EF, g of effluent per kg of fuel burned) for dozens of chemical species for several common southeastern fuel types. The major measurement campaigns were laboratory studies at the Missoula Fire Sciences Laboratory (FSL) as well as field campaigns at Camp Lejeune, NC, Ft. Jackson, SC, and in conjunction with 1648 at Vandenberg AFB, and Ft. Huachuca. Comparisons and fusions of laboratory and field data were also carried out, using laboratory fuels from the same bases. Results: The project enabled new technologies and furthered basic science, mostly in the area of infrared spectroscopy, a broadband method well suited to biomass burn studies. Advances in hardware, software and supporting reference data realized a nearly 20x improvement in sensitivity and now provide quantitative IR spectra for potential detection of ~60 new species and actual field quantification of several new species such as nitrous acid, glycolaldehyde, α-/β-pinene and D-limonene. The new reference data also permit calculation of the global warming potential (GWP) of the greenhouse gases by enabling 1) detection of their ambient concentrations, and 2) quantifying their ability to absorb IR radiation.

47 OTHER INSTRUMENTATION↗

Lifetime Energy and Environmental Impacts of Insulation Materials in Commercial Building Applications – Assessment Methodology and Sample Calculations

Application of insulation materials to building envelopes is a relatively easy and effective way of reducing energy consumption for space conditioning and, consequently, limiting the negative environmental impacts from the buildings sector. While insulation materials have a positive impact on the environment by reducing energy consumption in buildings, they also have some negative environmental impacts associated with their ‘embodied energy’. The total lifetime environmental impacts of insulation materials are a summation of: (1) direct impacts due to their embodied energy, and (2) indirect or environmental impacts avoided due to the reduced building energy consumption. It is important to identify insulation materials for buildings that will result in minimum negative environmental impacts. The objective of this project was to perform an assessment of the lifetime energy and environmental impacts of building insulation materials based on a previously developed protocol. The developed protocol was used for calculating the lifetime environmental impacts of selected insulation materials. Two Excel-based tools were developed: 1) to calculate embodied energy and GWP (equivalent CO 2 emissions) of insulation materials, and 2) to estimate energy savings and avoided environmental impacts due to the use of insulation materials in buildings. The direct environmental impacts were estimated using data from existing literature and life cycle analysis software; the indirect impacts were based on simulations of prototype whole-building models. This report summarizes the simulation study based on the recommendations of a previously developed protocol (A protocol for lifetime energy and environmental impact assessment of building insulation materials) by Shrestha et al., 2014. It also discusses a simplified algorithm based technique developed to quantify energy savings potential without requiring whole-building energy simulations. The report describes a proposed protocol that is intended to provide a comprehensive list of factors to be considered in evaluating the direct and indirect environmental impacts of building insulation materials, as well as detailed descriptions of standardized calculation methodologies to determine those impacts. Estimating the energy savings impact of insulation materials for the buildings in United States was an important aspect of this recommendation and comparative analyses of selected insulation materials were performed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Research and Development Roadmap For Next-Generation Low-Global Warming Potential Refrigerants

The Department of Energy commissioned this roadmap to establish a set of high-priority research and development (R&D) activities that will accelerate the transition to low-GWP refrigerants across the entire heating, ventilation, air-conditioning and refrigeration (HVAC&R) industry. The schedule of R&D activities occurs within an accelerated five-year timeframe, and covers several prominent equipment types. The roadmap is organized around four primary objectives to: assess and mitigate safety risks, characterize refrigerant properties, understand efficiency and environmental tradeoffs, and support new refrigerant and equipment development.

chillers↗

High Efficiency, Low Emission Refrigeration System

Supermarket refrigeration systems account for approximately 50% of supermarket energy use, placing this class of equipment among the highest energy consumers in the commercial building domain. In addition, the commonly used refrigeration system in supermarket applications is the multiplex direct expansion (DX) system, which is prone to refrigerant leaks due to its long lengths of refrigerant piping. This leakage reduces the efficiency of the system and increases the impact of the system on the environment. The high Global Warming Potential (GWP) of the hydrofluorocarbon (HFC) refrigerants commonly used in these systems, coupled with the large refrigerant charge and the high refrigerant leakage rates leads to significant direct emissions of greenhouse gases into the atmosphere. Methods for reducing refrigerant leakage and energy consumption are available, but underutilized. Further work needs to be done to reduce costs of advanced system designs to improve market utilization. In addition, refrigeration system retrofits that result in reduced energy consumption are needed since the majority of applications address retrofits rather than new stores. The retrofit market is also of most concern since it involves large-volume refrigerant systems with high leak rates. Finally, alternative refrigerants for new and retrofit applications are needed to reduce emissions and reduce the impact on the environment. The objective of this Collaborative Research and Development Agreement (CRADA) between the Oak Ridge National Laboratory and Hill Phoenix is to develop a supermarket refrigeration system that reduces greenhouse gas emissions and has 25 to 30 percent lower energy consumption than existing systems. The outcomes of this project will include the design of a low emission, high efficiency commercial refrigeration system suitable for use in current U.S. supermarkets. In addition, a prototype low emission, high efficiency supermarket refrigeration system will be produced for laboratory and field testing. Laboratory and field testing will demonstrate the high energy efficiency and low environmental impact of the refrigeration system developed in this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Future of Air Conditioning for Buildings - Executive Summary

The Building Technologies Office (BTO), within the U.S. Department of Energy’s (DOE) Office of Energy Efficiency and Renewable Energy, works with researchers and industry to develop and deploy technologies that can substantially reduce energy consumption and greenhouse gas (GHG) emissions in residential and commercial buildings. Air conditioning (A/C) systems in buildings contribute to GHG emissions both directly through refrigerant emissions, as well as indirectly through fossil fuel combustion for power generation. BTO promotes pre-competitive research and development (R&D) on next-generation HVAC technologies that support the phase down of hydrofluorocarbon (HFC) production and consumption, as well as cost-effective energy efficiency improvements. Over the past several decades, product costs and lifecycle cooling costs have declined substantially in many global markets due to improved, higher-volume manufacturing and higher energy efficiency driven by R&D investments and efficiency policies including minimum efficiency standards and labeling programs.1 This report characterizes the current landscape and trends in the global A/C market, including discussion of both direct and indirect climate impacts, and potential global warming impacts from growing global A/C usage. The report also documents solutions that can help achieve international goals for energy efficiency and GHG emissions reductions. The solutions include pathways related to low-global warming potential2 (GWP) refrigerants, energy efficiency innovations, long-term R&D initiatives, and regulatory actions. DOE provides, with this report, a fact-based vision for the future of A/C use around the world. DOE intends for this vision to reflect a broad and balanced aggregation of perspectives. DOE brings together this content in an effort to support dialogue within the international community and help keep key facts and objectives at the forefront among the many important discussions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration Project for a Multi-Material Lightweight Prototype Vehicle as Part of the Clean Energy Dialogue with Canada

The intent of the Multi-Material Lightweight Vehicle (“MMLV”) was to assess the feasibility of achieving a significant level of vehicle mass reduction, enabling engine downsizing resulting in a tangible fuel reduction and environmental benefit. The MMLV project included the development of two (2) lightweight vehicle designs, referred to as Mach-I and Mach-II MMLV variants, based on a 2013 Ford production C/D segment production vehicle (Fusion). Weight comparison, life cycle assessment and limited full vehicle testing are included in the project scope. The Mach-I vehicle variant was comprised of materials and processes that are commercially available or previously demonstrated. The 363 kg mass reduction associated with the Mach-I design enabled use of a one-liter, three-cylinder, gasoline turbocharged direct injection engine, maintaining the performance and utility of the baseline vehicle. The full MMLV project produced seven (7) MMLV Mach-I “concept vehicles” which were used for testing and evaluation. The full vehicle tests confirmed that MMLV Mach-I concept vehicle performed approximately equivalent to the baseline 2013 Ford Fusion vehicle thereby validating the design of the multi material lightweight vehicle design. The results of the Life Cycle Assessment, conducted by third party consultant, indicated that if the MMLV Mach-I design was built and operated in North America for 250,000 km (155,343 miles) it would produce significant environmental and fuel economy benefits including a 16% reduction in Global Warming Potential (GWP) and 16% reduction in Total Primary Energy (TPE). The LCA calculations estimated the combined fuel economy of 34 mpg (6.9 l/100 km) associated with the MMLV Mach-I Design compared to 28 mpg (8.4 l/100 km) for the 2013 Ford Fusion.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Efficiency Water Heating Technology Development Final Report, Part II: CO 2 and Absorption-Based Residential Heat Pump Water Heater Development

The two objectives of this project were to 1.demonstrate an affordable path to an ENERGY STAR qualified electric heat pump water heater (HPWH) based on low-global warming potential (GWP) CO 2 refrigerant, and 2.demonstrate an affordable path to a gas-fired absorption-based heat pump water heater with a gas energy factor (EF) greater than 1.0. The first objective has been met, and the project has identified a promising low-cost option capable of meeting the second objective. This report documents the process followed and results obtained in addressing these objectives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Milestone Report:3.2.2.26 Appliances, HVAC & Water Heating R&D-Select Sorption Technology

The purpose of this report is to select a sorption technology based on recent work completed on characterizing working pairs for both absorption and adsorption technologies based on Global Warming Potential (GWP) of less than 100 (relative to carbon dioxide, 100-year atmospheric life span) and zero Ozone Depletion Potential (ODP). From a total of eighty-three potential working pairs (absorption technology), there were only two candidate working pairs for the absorption technology, and 8 potential working pairs for adsorption technology. After screening these ten potential candidates on the basis of sizes of the desorber, absorber/adsorber, evaporator, condenser, and rectifier (where applicable), the ORNL-Georgia Tech study concluded that best working pairs are NH3-H2O for the most compact system in terms of heat transfer equipment surface area, and NH3-LiNO3 and MeOH-[mmin][DMP] where efficiency is most important. Based on a single-stage absorption and adsorption modeling using the Engineering Equation Solver (EES), the performance of both sorption systems was evaluated from known heat transfer correlations, and thermos-physical properties. Based on these results, the technology chosen is absorption technology. The selected technology is absorption for the reasons cited in Section 4.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technical and Economic Aspects of Designing an Efficient Room Air-Conditioner Program in India

Several studies have projected a massive increase in the demand for air conditioners (ACs) over the next two decades in India. By 2030, room ACs could add 140 GW to the peak load, equivalent to over 30% of the total projected peak load. Therefore, there is significant interest among policymakers, regulators, and utilities in managing room AC demand by enhancing energy efficiency. Building on the historical success of the Indian Bureau of Energy Efficiency’s star-labeling program, Energy Efficiency Services Limited recently announced a program to accelerate the sale of efficient room ACs using bulk procurement, similar to their successful UJALA light-emitting diode (LED) bulk procurement program. This report discusses some of the key considerations in designing a bulk procurement or financial incentive program for enhancing room AC efficiency in India. We draw upon our previous research to demonstrate the overall technical potential and price impact of room AC efficiency improvement and its technical feasibility in India. We also discuss the importance of using low global warming potential (GWP) refrigerants and smart AC equipment that is demand response (DR) ready.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methodology for Estimating Safe Charge Limits of Flammable Refrigerants in HVAC&R Applications - Part 1

Refrigerant flammability introduces new challenges to the usage of low global warming potential (Low GWP) refrigerants in real life applications. Those challenges are centered around the deflagration risk associated with their use and its implications on personal safety. Standards have been developed to systematically set maximum allowable flammable refrigerant charges to ensure safety in case of refrigerant leakage. These standards were initially based on limited testing and numerical analyses of refrigerant leakage into confined spaces.

42 ENGINEERING↗

Extending ORNL HPDM Capabilities for Design and Optimization of New Refrigerant Blends – FY18 2nd Quarter Milestone Report: Improve HPDM to Adopt New Refrigerant Properties and Correlations

We added new refrigerant properties of HFO blends to the ORNL HPDM, including R-22 alternatives, i.e. N20b, DR3, ARM20a, ARM20b, R444B, DR93; R-410A alternatives, i.e. R447A, R447B, R452B, R32, ARM71a; R-134a alternatives, i.e. R1234yf and R1234ze. It can also simulate natural refrigerants, e.g. propane (R290), Isobutane (R600a), CO2 and Ammonia. In addition, latest heat transfer and pressure drop correlations best for low GWP refrigerants were integrated to the equipment design and simulation software.

36 MATERIALS SCIENCE↗

Extending ORNL HPDM Capabilities for Design and Optimization of New Refrigerant Blends – FY18 1st Quarterly Milestone: Perform literature review to collect heat transfer, pressure drop correlations and compressor mapping method for alternative refrigerants

Through a comprehensive literature survey, we identified heat transfer and pressure drop correlations for two-phase evaporation and condensation in fin-and-tube coils using microfin tubes and micro-channel heat exchangers. We also developed a compressor mapping method to convert the maps originally developed for R-22 or R-410A to be used by the alternative lower GWP refrigerants. The correlations and method will be implemented in HPDM for design and optimization of air conditioners and heat pumps using the new refrigerants/blends.

42 ENGINEERING↗

Performance Evaluation of the ThermoLift Natural Gas Fired Air Conditioner and Cold-Climate Heat Pump

ThermoLift is currently developing its Thermal Compression Heat Pump (TCHP™), a natural-gas driven air conditioner and cold-climate heat pump, which can provide space heating, water heating, and air conditioning simultaneously in a single device. The system has broad application as a combined heating, ventilation, and air-conditioning (HVAC) solution with the benefit of substantial energy, cost, and greenhouse gas (GHG) reductions. Unlike traditional vapor compression heat-pumps, the TCHP™ uses helium as a working fluid in place of high global warming potential (GWP) refrigerants. The development effort has produced three iterations or generations of prototypes with advancement of the technology readiness level (TRL) from TRL-1 (TCHP™ Gen 1.0) to TRL-5 (TCHP™ Gen 3.0). In August of 2013, the US DOE solicited the submission of proposals through funding opportunity announcement DE-FOA-0000823, Building Technologies Innovations Program. The Office of Energy Efficiency and Renewable Energy (EERE) subsequently accepted ThermoLift’s proposal to develop a heat pump system based on the Hofbauer cycle, a new cycle that supplants the Vuilleumier cycle and provided funding for prototype evaluation at Oak Ridge National Laboratory (ORNL). ORNL is a widely known research center for developing and evaluating building technologies. Through its Building Technologies Research and Integration Center, ORNL has unique capabilities which allows them to collaborate with industry and academia to advance building component technologies. The TCHP™ Gen 3.0 prototype was shipped to ORNL on July 23, 2018. After installation and integration of the heat pump into ORNL’s test facility and performing instrumentation validation and calibration, extended operation of the heat pump was achieved during continuous operation on August 6, 2018, and includes various heating and cooling temperature ranges and performance analysis. The Gen 3.0 prototype was evaluated at four “ambient” temperatures: −25°C, −8.33°C, 8.33°C, and 20°C, (−13°F, 17°F, 47°F, and 68°F) denoted as test points 1-4, respectively. For heating, cycle coefficients of performance (COP) at the four “ambient” temperatures were found to be 1.30, 1.46, 1.52, and 1.61, respectively. Furthermore, there is no capacity reduction as the inlet temperature to the cold heat exchanger (HX) decreases. The heating capacity delivered by the TCHP was found to be 12 kW at -25°C. Finally, this final report identifies measures for obtaining further efficiency improvements.

42 ENGINEERING↗

Refrigerants: Market Trends and Supply Chain Assessment

The National Renewable Energy Laboratory (NREL), in partnership with ORNL, under the Clean Energy Manufacturing Analysis Center (CEMAC www.manufacturingcleanenergy.org) umbrella, assessed the current state of existing and low-GWP refrigerants for major end-use applications, including HVAC and those outside of the HVAC industry. The project incorporated a market overview, and supply chain assessment to determine the production, distribution, consumption, costs, and potential operating efficiency impacts of new and alternative refrigerants entering the market. Market trends and ongoing research are also documented. This work supplements other DOE efforts to support research activities on refrigerants and their applications including a refrigerant R&D roadmap and outlook into global air conditioning markets (Goetzler et al. 2014, 2016).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving Gas Reactor Design with Complex Non-Standard Reaction Mechanisms in a Reactive Flow Model

Fluorinated gases are critical to a number of high-technology industries including semiconductor manufacturing and related processes such as flat panel display, LED, and photovoltaic manufacturing. These fluorinated gases have very high global warming potentials (GWPs) and, unfortunately are chemically very stable, in some cases lasting for thousands of years in the atmosphere. For environmental reasons, it is imperative that the release of these gases be minimized, but existing methods to destroy them requires a significant amount of energy. The goal of this project was to develop a more energy efficient method of destroying these high GWP gases using computational fluid dynamics, but the computational requirements are significant. In this project, we bring together resources available at the national labs, including high-performance computing hardware and modern computational methods, in order to explore an industrially important problem with key environmental and economic impact. In this project, we examined the state-of-the-art models for the physical processes involved, and made subtle changes to arrive at alternative formulations considerably better suited for computation and study. We examined several representative scenarios and developed a set of analyses techniques and tools that could be used to explore the systems in much greater detail. This exploratory project has demonstrated to ALZETA that HPC can indeed provide a unique view into their complex engineering problem - one that is simply inaccessible by any other means. The tools allow us to explore the details of the chemical process, and allow one to construct "what-if" scenarios to address shortcomings of the physical device in its current operating modes. However, as with many sources of completely new information, many new questions are illuminated with this capability. It will take considerable time, effort and experience before we learn to probe the solutions, pose operating scenarios and confirm modifications to the device that lead to real engineering advances.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Risk Assessment of Catastrophic Leak Of R-452b From Package Unit into A Residential Space

With the effort to find alternative refrigerants with lower global warming potential (GWP), challenges have arisen due to the flammability risk for many of the alternatives. One of the new alternatives is R-452B, which is recommended as a replacement for R410A. R-452B is classified as a mildly flammable refrigerant (A2L) by ANSI/ASHRAE Standard 34. This paper summarizes a computational fluid dynamic (CFD) simulation study of a leak incident of R-452B from a 3-ton packaged unit which serves a 167 m 2 residence. The R-452B leak is assumed to be downstream of the evaporator coil. The simulated residence has four rooms and a hallway. The packaged unit distributes the conditioned air through a supply duct system delivering the air through registers. The dispersion of R-452B is characterized for two scenarios: one with underfloor supply air ducts and another with ceiling supply air ducts. The mass flow rate of R-452B exiting the duct outlets is quantified and the refrigerant volume fraction is monitored inside the residential space.

42 ENGINEERING↗