Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GUNS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Microwave ignition systems with launcher affixed to or located within a gun spindle

Microwave ignition systems with a launcher affixed to or located within a gun spindle. Use of a planar, impedance matched system that include a launcher affixed to or located within a gun spindle and a receiver affixed the propelling charge, where the receiver is engineered and impedance matched to efficiently deposit energy into the receiving igniter material, may result in significantly better timing and reliability than conventional mechanical gun ignition systems and other microwave ignition systems. A pressure-tolerant feed through system can route the microwave energy to the inside of the breech.

Duque, Amanda Lynn↗

JLab FEL DC Gun

The Jefferson Lab (JLab) Energy Recovery Linac 10 kW IR Upgrade Free Electron Laser (FEL) is driven by a 350kV DC un-polarized photoemission electron gun. In 2003, an upgrade version of the earlier 1 kW IR Demo FEL gun delivered over 1000 Coulombs with a single Cs:GaAs wafer in one year of operation. Between 2004 and 2007 a second wafer delivered over 7000 Coulombs and up to 9 mA CW beam for FEL operations. Both wafers suffered surface damage with total loss of quantum efficiency in several occasions during high current operations. Since then, the electron gun has been refurbished two times due to field emission damage. Although presently operating at nominal 350kV, field emission has significantly decreased the photocathode lifetime.

Hernandez-Garcia, Carlos↗

A CW normal-conductive RF gun for free electron laser and energy recovery linac applications

Currently proposed energy recovery linac and high average power free electron laser projects require electron beam sources that can generate up to {approx} 1 nC bunch charges with less than 1 mmmrad normalized emittance at high repetition rates (greater than {approx} 1 MHz). Proposed sources are based around either high voltage DC or microwave RF guns, each with its particular set of technological limits and system complications. We propose an approach for a gun fully based on mature RF and mechanical technology that greatly diminishes many of such complications. The concepts for such a source as well as the present RF and mechanical design are described. Simulations that demonstrate the beam quality preservation and transport capability of an injector scheme based on such a gun are also presented.

43 PARTICLE ACCELERATORS↗

A high current density plasma cathode electron gun

The design, performance, and characteristics of a plasma cathode electron gun are presented. The plasma cathode is based on a hollow cathode direct current discharge, and the electron beam is accelerated by pulse voltage. By discharging at high gas pressure and operating at low gas pressure, both the maximum accelerating voltage and maximum emitting current could be increased. Utilizing argon, with the accelerating voltage up to 9 kV and gas pressure down to 52 mPa, the gun is able to generate an electron beam of about 4.7 A, and the corresponding emitting current density is about 600 A/cm{sup 2}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma-filled diode based on the coaxial gun

The paper presents the results of studies of a coaxial gun for a plasma-filled electron diode. Effects of the discharge channel diameter and gun current on characteristics of the plasma and pulse generated in the diode were investigated. The electron beam with maximum energy of {>=}1 MeV at the current of Almost-Equal-To 100 kA was obtained in the experiments with a plasma-filled diode. The energy of Almost-Equal-To 5 kJ with the peak power of {>=}100 GW dissipated in the diode.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Laser-free RF-gun as a combined source of THz and ps-sub-ps X-rays

A coherent, mm-sub-mm-wave source driven by a RF electron gun is proposed for wide research applications as well as auxiliary inspection and screening, safe imaging, cancer diagnostics, surface defectoscopy, and enhanced time-domain spectroscopy. It allows generation of high peak and average THz-sub-THz radiation power provided by beam pre-bunching and chirping in the RF gun followed by microbunching in magnetic compressor, and resonant Cherenkov radiation of an essentially flat beam in a robust, ~inch-long, planar, mm-sub-mm gap structure. The proof-of-principle has been successfully demonstrated in Phase I on a 5 MeV beam of L-band thermionic injector of Idaho Accelerator Center. The system can also deliver an intense, ps-sub-ps bursts of low-to-moderate dose of relativistic electrons and X-ray radiation produced by the same beam required for pulsed radiolysis as well as to enhance screening efficiency, throughput and safety.

43 PARTICLE ACCELERATORS↗

Magnetron injection gun for a broadband gyrotron backward-wave oscillator

The magnetron injection gun is capable of generating relativistic electron beam with high velocity ratio and low velocity spread for a gyrotron backward-wave oscillator (gyro-BWO). However, the velocity ratio ({alpha}) varies drastically against both the magnetic field and the beam voltage, which significantly limits the tuning bandwidth of a gyro-BWO. This study remedies this drawback by adding a variable trim field to adjust the magnetic compression ratio when changing the operating conditions. Theoretical results obtained by employing a two-dimensional electron gun code (EGUN) demonstrate a constant velocity ratio of 1.5 with a low axial velocity spread of 6% from 3.4-4.8 Tesla. These results are compared with a three-dimensional particle-tracing code (computer simulation technology, CST). The underlying physics for constant {alpha} will be discussed in depth.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A contoured gap coaxial plasma gun with injected plasma armature

A new coaxial plasma gun is described. The long term objective is to accelerate 100-200 {mu}g of plasma with density above 10{sup 17} cm{sup -3} to greater than 200 km/s with a Mach number above 10. Such high velocity dense plasma jets have a number of potential fusion applications, including plasma refueling, magnetized target fusion, injection of angular momentum into centrifugally confined mirrors, high energy density plasmas, and others. The approach uses symmetric injection of high density plasma into a coaxial electromagnetic accelerator having an annular gap geometry tailored to prevent formation of the blow-by instability. The injected plasma is generated by numerous (currently 32) radially oriented capillary discharges arranged uniformly around the circumference of the angled annular injection region of the accelerator. Magnetohydrodynamic modeling identified electrode profiles that can achieve the desired plasma jet parameters. The experimental hardware is described along with initial experimental results in which approximately 200 {mu}g has been accelerated to 100 km/s in a half-scale prototype gun. Initial observations of 64 merging injector jets in a planar cylindrical testing array are presented. Density and velocity are presently limited by available peak current and injection sources. Steps to increase both the drive current and the injected plasma mass are described for next generation experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low Emittance Electron Gun for XFEL Application

The Paul Scherrer Institute (PSI) in Switzerland is planning to build a cost-effective X-ray Free Electron Laser (XFEL) facility for 0.1-10 nm wavelength and 10-100 fsec pulse length, requiring only 6 GeV electron energy. The facility will consist of a Low Emittance electron Gun (LEG) with high gradient acceleration and advanced accelerator technology for preserving the emittance during acceleration and bunch compression. To demonstrate feasibility of the project, a 4 MeV test stand followed by a new 250 MeV test stand will be used at PSI. An emittance of <0.1 mm-mrad is desired, and this extreme value has prompted the development of several novel features: gated field emitting array, a pulsed high gradient gun, combined photo-field emission, pulsed solenoid focusing and a two-frequency cavity. The LEG should give stable emission of >200 pC, with >700 keV energy and >125 MV/m gradient.

43 PARTICLE ACCELERATORS↗

Ion bombardment in RF guns

We use the ponderomotive potential of the RF field to study the motion of ions in an RF gun. We apply this method to the BNL 1/2-cell SRF photogun and demonstrate that a significant portion of the ions produced in the gun can reach the cathode if no special precautions are taken. Also, we propose simple mitigation techniques that can reduce the rate of ion bombardment.

43 PARTICLE ACCELERATORS↗

High-Fidelity RF Gun Simulations with the Parallel 3D Finite Element Particle-In-Cell Code Pic3P

SLAC's Advanced Computations Department (ACD) has developed the first parallel Finite Element 3D Particle-In-Cell (PIC) code, Pic3P, for simulations of RF guns and other spacecharge dominated beam-cavity interactions. Pic3P solves the complete set of Maxwell-Lorentz equations and thus includes space charge, retardation and wakefield effects from first principles. Pic3P uses higher-order Finite Element methods on unstructured conformal meshes. A novel scheme for causal adaptive refinement and dynamic load balancing enable unprecedented simulation accuracy, aiding the design and operation of the next generation of accelerator facilities. Application to the Linac Coherent Light Source (LCLS) RF gun is presented.

43 PARTICLE ACCELERATORS↗

High Intensity Polarized Electron Gun Studies at MIT-Bates

A proposed new high-luminosity electron-ion collider requires a polarized electron source of extremely high intensity. An ion back bombardment of the cathode is the main factor limiting the intensity of modern polarized electron guns. This study examines the possibility of building a very high intensity polarized electron gun.

43 PARTICLE ACCELERATORS↗

Development of a low-energy and high-current pulsed neutral beam injector with a washer-gun plasma source for high-beta plasma experiments

We have developed a novel and economical neutral-beam injection system by employing a washer-gun plasma source. It provides a low-cost and maintenance-free ion beam, thus eliminating the need for the filaments and water-cooling systems employed conventionally. In our primary experiments, the washer gun produced a source plasma with an electron temperature of approximately 5 eV and an electron density of 5 Multiplication-Sign 10{sup 17} m{sup -3}, i.e., conditions suitable for ion-beam extraction. The dependence of the extracted beam current on the acceleration voltage is consistent with space-charge current limitation, because the observed current density is almost proportional to the 3/2 power of the acceleration voltage below approximately 8 kV. By optimizing plasma formation, we successfully achieved beam extraction of up to 40 A at 15 kV and a pulse length in excess of 0.25 ms. Its low-voltage and high-current pulsed-beam properties enable us to apply this high-power neutral beam injection into a high-beta compact torus plasma characterized by a low magnetic field.

43 PARTICLE ACCELERATORS↗

W(310) cold-field emission characteristics reflecting the vacuum states of an extreme high vacuum electron gun

An extremely high vacuum cold-field electron emission (CFE) gun operating at pressures ranging from {approx}10{sup -8} Pa to {approx}10{sup -10} Pa was constructed. Only the CFE current emitting from W(310) surfaces revealed the existence of a 'stable region' with high current angular density just after tip flash heating. In the 'stable region,' the CFE current was damped very slowly. The presence of non-hydrogen gas eliminated this region from the plot. Improvement of the vacuum prolonged the 90% damping time of the CFE current from {approx}10 min to 800 min. The current angular density I{sup Prime} of CFE current was 60 and 250 {mu}A/sr in the 'stable region' for total CFE currents of 10 and 50 {mu}A, respectively. These results were about three times larger than I{sup Prime} when measured after the complete damping of the CFE current. The CFE gun generated bright scanning transmission electron microscopy images of a carbon nanotube at 30 kV.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A high-current electron gun for the electron beam ion trap at the National Superconducting Cyclotron Laboratory

The Electron Beam Ion Trap (EBIT) in NSCL’s reaccelerator ReA uses continuous ion injection and accumulation. In order to maximize capture efficiency and minimize breeding time into high charge states, the EBIT requires a high-current/high current-density electron beam. A new electron gun insert based on a concave Ba-dispenser cathode has been designed and built to increase the current transmitted through the EBIT’s superconducting magnet. With the new insert, stable EBIT operating conditions with 0.8 A of electron beam have been established. The design of the electron gun is presented together with calculated and measured perveance data. In order to assess the experimental compression of the electron beam, a pinhole CCD camera has been set up to measure the electron beam radius. The camera observes X-rays emitted from highly charged ions, excited by the electron beam. Initial tests with this camera setup will be presented. They indicate that a current density of 640 A/cm{sup 2} has been reached when the EBIT magnet was operated at 4 T.

43 PARTICLE ACCELERATORS↗

Note: Simulation and test of a strip source electron gun

We present simulation and test of an indirectly heated strip source electron beam gun assembly using Stanford Linear Accelerator Center (SLAC) electron beam trajectory program. The beam is now sharply focused with 3.04 mm diameter in the post anode region at 15.9 mm. The measured emission current and emission density were 1.12 A and 1.15 A/cm{sup 2}, respectively, that corresponds to power density of 11.5 kW/cm{sup 2}, at 10 kV acceleration potential. The simulated results were compared with then and now experiments and found in agreement. The gun is without any biasing, electrostatic and magnetic fields; hence simple and inexpensive. Moreover, it is now more powerful and is useful for accelerators technology due to high emission and low emittance parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study on the steady operating state of a micro-pulse electron gun

Micro-pulse electron gun (MPG) employs the basic concept of multipacting to produce high-current and short-pulse electron beams from a radio-frequency (RF) cavity. The concept of MPG has been proposed for more than two decades. However, the unstable operating state of MPG vastly obstructs its practical applications. This paper presents a study on the steady operating state of a micro-pulse electron gun with theory and experiments. The requirements for the steady operating state are proposed through the analysis of the interaction between the RF cavity and the beam load. Accordingly, a MPG cavity with the frequency of 2856 MHz has been designed, constructed, and tested. Some primary experiments have been finished. Both the unstable and stable operating states of the MPG have been observed. The stable output beam current has been detected at about 3.8 mA. Further experimental study is under way now.

43 PARTICLE ACCELERATORS↗

Design, conditioning, and performance of a high voltage, high brightness dc photoelectron gun with variable gap

A new high voltage photoemission gun has been constructed at Cornell University which features a segmented insulator and a movable anode, allowing the cathode-anode gap to be adjusted. In this work, we describe the gun's overall mechanical and high voltage design, the surface preparation of components, as well as the clean construction methods. We present high voltage conditioning data using a 50 mm cathode-anode gap, in which the conditioning voltage exceeds 500 kV, as well as at smaller gaps. Finally, we present simulated emittance results obtained from a genetic optimization scheme using voltage values based on the conditioning data. These results indicate that for charges up to 100 pC, a 30 mm gap at 400 kV has equal or smaller 100% emittance than a 50 mm gap at 450 kV, and also a smaller core emittance, when placed as the source for the Cornell energy recovery linac photoinjector with bunch length constrained to be <3 ps rms. For 100 pC up to 0.5 nC charges, the 50 mm gap has larger core emittance than the 30 mm gap, but conversely smaller 100% emittance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗