Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GLOVEBOXES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Evaluation of Detritiation Strategies for Mitigating Tritium Releases

Tritium confinement is performed using different barriers to minimize releases to the environment. Primary confinement is usually performed by process piping and components, secondary confinement typically by inerted gloveboxes connected to a continuously operating tritium stripper system. Some facility designs employ tertiary tritium confinement by using process room confinement with a tritium stripper system activated after an accident to further mitigate tritium releases to the environment. Secondary confinement of some tritium systems such as radiation-hardened or shielded-cell enclosures are not easily achieved using designs for inerted glovebox. These enclosures can be challenging to seal for secondary tritium confinement due to heating, ventilation, and air conditioning (HVAC) needs for temperature control, as well as feedthroughs for equipment and instrumentation, are potential pathways for tritium leaks or loses. Additional tritium leak paths can be created in secondary confinement enclosures due to a Design Basis Accident (DBA) seismic event. These new, larger tritium leak rates from the DBA event are usually not part of the stripper system design basis so all tritium released to the secondary confinement enclosure is assumed released to the environment. Detritiation strategies for shielded enclosures and/or gloveboxes with significant leak rates are necessary to minimize off-site radiological dose consequences. To address this, the relationship between the confinement system leak rate and stripper system (recirculating) flow rate was evaluated to meet prescribed maximum allowable environmental tritium emissions from the event. The simple analysis described assumes a constant leak rate from the confinement system (i.e. shielded enclosure or glovebox) while a recirculating stripper system strips tritium from the system– a competition between tritium release and tritium recovery. At a high level, the resulting expression summarizes the relationship between system leak rate (F L ) and stripper flow rate (F S ) relative to allowable tritium release (Q A ) and initial tritium release (Q 0 ): $\frac{F_L}{F_s}$ ≈ $\frac{Q_A}{Q_0}$. This report derives the relationship between these parameters, examines the impact of finite stripping times followed by purging of the stripped volume. The analysis provides example results for up to 30 gram tritium releases: the maximum tritium inventory of a Hazard Category III (Department of Energy) Nuclear Facility. The detritiation model presented represents a high-level analysis of tritium recovery versus losses for “leaky” confinement enclosures such as shielded cells after large tritium releases. Key parameters for doing the analyses are the system leak rate, stripper flow rate, initial tritium release, and allowable tritium release values. The analyses show a proportional decrease in releases with reduction in initial tritium release but a non-linear increase in tritium recovery with increased stripper flow rate or reduced leak-rate. The analyses also apply to glovebox confinement systems which could have significant increases in leak rates after a DBA. The analysis recognizes but does not include tritium absorption followed by re-emission from the walls of the confinement volume – an analysis which could be pursued in future studies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

GeoLab in NASA's Pressurized Excursion Module: First Results from the 2010 Field Trials

Before humans explore other planets, NASA must develop advanced techniques for collection, preservation and return of unique extraterrestrial samples. To help evaluate hardware requirements and operational concepts for future sample-return missions, we designed and built GeoLab our first generation lab for geological samples into NASA s Habitat Demonstration Unit in the Pressurized Excursion Module (HDU1-PEM). The center of GeoLab is a glovebox for the examination of samples in a shirt-sleeve environment. As part of a deployable habitat, GeoLab can participate in NASA s analog missions that simulate planetary exploration activities and support the testing of relevant technologies for collecting and handling geological samples. Over time, these tests will evaluate sample handling environments (field and lab), sampling tools and analytical instruments, and different scenarios involving both robotic and human procedures. The GeoLab design supports evolving tests and configurations. The glovebox is mounted on the habitat bulkhead, with three sample pass-though chambers that allow for direct sample transfer into the glovebox from the outside. The glovebox design and construction (low-particle shedding, minimally off-gassing materials) provides a clean environment to reduce sample contamination; in the future, we will integrate a positive pressure, enriched nitrogen atmosphere. The glovebox is equipped with configurable instrument ports. The 2010 test included a mass balance, a stereomicroscope with a HD camera for detailed imaging of samples, and a handheld XRF analyzer for preliminary geochemical characterization of samples. Network cameras provided context imagery and sample handling activities. We present early results from the initial field trial of GeoLab during the 2010 Desert Research and Technology Studies (D-RATS) planetary analog test near Flagstaff AZ. The 2010 D-RATS mission involved two rovers, the habitat with GeoLab, four crew members, and a team of scientists and flight controllers. The crewed rovers conducted geological traverses and collected samples on the planetary surface. Selected samples were transferred into GeoLab for detailed examination and initial analysis, providing critical data to the science team for evaluation and prioritization of samples.

Evans, Cynthia A.↗

GeoLab: A Geological Workstation for Future Missions

The GeoLab glovebox was, until November 2012, fully integrated into NASA's Deep Space Habitat (DSH) Analog Testbed. The conceptual design for GeoLab came from several sources, including current research instruments (Microgravity Science Glovebox) used on the International Space Station, existing Astromaterials Curation Laboratory hardware and clean room procedures, and mission scenarios developed for earlier programs. GeoLab allowed NASA scientists to test science operations related to contained sample examination during simulated exploration missions. The team demonstrated science operations that enhance theThe GeoLab glovebox was, until November 2012, fully integrated into NASA's Deep Space Habitat (DSH) Analog Testbed. The conceptual design for GeoLab came from several sources, including current research instruments (Microgravity Science Glovebox) used on the International Space Station, existing Astromaterials Curation Laboratory hardware and clean room procedures, and mission scenarios developed for earlier programs. GeoLab allowed NASA scientists to test science operations related to contained sample examination during simulated exploration missions. The team demonstrated science operations that enhance the early scientific returns from future missions and ensure that the best samples are selected for Earth return. The facility was also designed to foster the development of instrument technology. Since 2009, when GeoLab design and construction began, the GeoLab team [a group of scientists from the Astromaterials Acquisition and Curation Office within the Astromaterials Research and Exploration Science (ARES) Directorate at JSC] has progressively developed and reconfigured the GeoLab hardware and software interfaces and developed test objectives, which were to 1) determine requirements and strategies for sample handling and prioritization for geological operations on other planetary surfaces, 2) assess the scientific contribution of selective in-situ sample characterization for mission planning, operations, and sample prioritization, 3) evaluate analytical instruments and tools for providing efficient and meaningful data in advance of sample return and 4) identify science operations that leverage human presence with robotic tools. In the first year of tests (2010), GeoLab examined basic glovebox operations performed by one and two crewmembers and science operations performed by a remote science team. The 2010 tests also examined the efficacy of basic sample characterization [descriptions, microscopic imagery, X-ray fluorescence (XRF) analyses] and feedback to the science team. In year 2 (2011), the GeoLab team tested enhanced software and interfaces for the crew and science team (including Web-based and mobile device displays) and demonstrated laboratory configurability with a new diagnostic instrument (the Multispectral Microscopic Imager from the JPL and Arizona State University). In year 3 (2012), the GeoLab team installed and tested a robotic sample manipulator and evaluated robotic-human interfaces for science operations.

Evans, Cynthia↗

Concurrent Uranium Overmass and Hydraulic Fluid Leak

In the Spring of 2017, the Y-12 National Security Complex had a NCS operational event involving hydraulic fluid leaking into a glovebox containing fissile material. The hydraulic fluid intermixed with fissile material in the glovebox but remained in a safe slab-like configuration. Unknown at the time, a large enough mass of uranium to support a moderated nuclear criticality accident resided below the glovebox floor in an unfavorable volume sand separator system. Thanks to the operator following procedures and shutting down the hydraulic pump supplying the jolter, a potential accident was adverted. As a result of the event, significant physical modifications were made to the process to enhance safety. Additionally, changes were made in how the materials in the glovebox are processed in order to prevent liquid intrusion and significant uranium accumulation in the sand separator system.

42 ENGINEERING↗

WIPP Space Faces TRU Waste Disposal Limits; The Volume Reducing Solution - 18365

Transuranic (TRU) waste packaging for removal from a glovebox has for many years involved the use of bags as the primary containment. In many cases, many hydrogenous layers of bags, yards of tape, and multiple filters are added to the waste stream in order to get the TRU waste into the final 55 gallon drum package to be shipped and buried at the Waste Isolation Pilot Plant (WIPP). The WIPP is currently limited to a total finite disposed volume of Contact Handled (CH) and Remote Handled (RH) TRU waste. As of early 2014 over half of the allotted WIPP volume had been filled with mainly CH-TRU waste. Based on current bag operation packaging methods used, the Department of Energy's (DOE) remaining CH and RH waste will not fit in the remaining limited WIPP space. Bag operations, can be performed safely by good operators following tedious repetitive processes and many Administrative Safety Controls. Since the bag is the only confinement layer between the contamination and the operator, contamination incidents can occur. Bag-out operations require close proximity to the waste to perform the process. With some waste streams, this close to waste proximity increases operator radiation dose. Central Research Laboratories (CRL), based in Red Wing Minnesota, who for many decades has developed proven engineered material transfer solutions based around their Rapid Transfer Port (RTP) technology, has worked with DOE sites to develop a TRU Waste Management Solution. The solution is a single filtered large Polyethylene (PE) or Stainless Steel (SST) Rapid Transfer Port container in a standard Department of Transportation (DOT) 7A, Type A drum, which allows for loading of TRU waste directly from the operational glovebox without the use of bags, sleeves or tapes to provide leak tight containment. All operator interventions to connect and disconnect a drum to and from the glovebox are achieved in an upright ergonomic position by one (1) operator in less than three (3) minutes. Minimal As Low As Reasonably Achievable (ALARA) levels are achieved during connect and disconnect of the drum, due to the engineered safety controls of the RTP. The CRL RTP solution allows glovebox or re-packaged TRU waste to be safely transferred to the final 55 Gallon drum container without additional bags or tape. The high diffusion coefficient filter on the CRL RTP 55G container and elimination of added hydrogenous packaging, improves the Decay Heat Limit (DHL) per drum for most TRU waste types compared with bagged drums, and in most cases allows more TRU waste to be loaded per drum. Inorganic TRU waste materials can be packaged directly into the CRL RTP SST drum container to the maximum DHL and Fissile Gram Equivalent (FGE) allowable for a drum. This paper will show how highly efficient TRAMPAC approved TRU waste packaging of CH and RH TRU waste can be accomplished in a safer, cost effective manner without adding any additional packaging materials to the waste stream, thus increasing the chance of placing all DOE's legacy and to be generated TRU waste in the remaining WIPP space. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Simple, Revolutionary Approach to Waste Packaging Utilizing Proven Technology - 20201

Historically, removing hazardous waste from gloveboxes involves the use of bags as the primary containment method. This method can prove tedious, repetitive, and time consuming to ensure the process follows all safeguards required to contain the waste and mitigate any breach of containment. Layers of bags, yards of tape, and multiple filters are added to the waste stream in order to transfer the hazardous waste from the glovebox safely into the drum package. Then, finally, it can be shipped and disposed of. The process to cut, tie, and tape each bag for disposal involves manual effort by multiple operators. Following Administrative Safety Controls, good operators are able to safely perform those tasks; but, since the bag is the only confinement layer, incidents can occur. Operators, in some cases, are also at close proximity to this waste which may increase the risk of radiation exposure. Once the waste is transferred out through these bags, it is nearly impossible to remove packaged waste that may contain higher dosage levels, thus increasing drum disposal costs incurred by the facility. Exceeding the allowable radiation levels, and drums not fully filled, both contribute significantly to excess disposal costs. Central Research Laboratories (CRL), based in Red Wing Minnesota, has developed the Waste Drum Transfer System (WDTS) building upon the proven technology and containment of the Rapid Transfer Port (RTP) as an alternate, more efficient method of waste transfer. This solution consists of an RTP Alpha port mounted inside a glovebox and Beta assembly unit composed of a drum liner fitted inside a standard 55 gallon drum. The use of the Beta drum liner bypasses the typical use of bags, sleeves or tape to provide leak tight containment. The process to connect and disconnect a drum from the glovebox is achieved by the self-docking and rotating system controls of the RTP Alpha, all done with only one operator standing in an upright ergonomic position. This system also allows for greater flexibility in available Beta connection options, expanding the overall functionality of the system. This system can be disconnected and reconnected multiple times to maximize volume containment. This will minimize drum disposal costs and reduce the overall volume of waste output by more efficiently filling the drums. Radiation levels inside each drum can be monitored and adjusted more efficiently by operators utilizing the reconnect option. Minimal As Low As Reasonably Achievable (ALARA) levels are also achievable with this system. This paper will show how highly efficient packaging and disposal of hazardous waste can be accomplished in a cost-effective manner utilizing the proven RTP technology. Maximized operator productivity and safety, as well as minimized radiation dose exposure, are all attainable through the system's engineered controls. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reliability study of an emerging fire suppression system

Self-contained fire extinguishers are a robust, reliable and minimally invasive means of fire suppression for gloveboxes. Plutonium gloveboxes are known to present harsh environmental conditions for polymer materials, these include radiation damage and chemical exposure, both of which tend to degrade the lifetime of engineered polymer components. The primary component of interest in self-contained fire extinguishers is the nylon 6-6 machined tube that comprises the main body of the system.Thermo-mechanical modeling and characterization of nylon 6-6 for use in plutonium glovebox applications has been carried out. Data has been generated regarding property degradation leading to poor, or reduced, engineering performance of nylon 6-6 components. In this study, nylon 6-6 tensile specimens conforming to the casing of self-contained fire extinguisher systems have been exposed to hydrochloric, nitric, and sulfuric acids. This information was used to predict the performance of a load bearing engineering component comprised of nylon 6-6 and designed to operate in a consistent manner over a specified time period. The study provides a fundamental understanding of the engineering performance of the fire suppression system and the effects of environmental degradation due to acid exposure on engineering performance. Data generated help identify the limitations of self-contained fire extinguishers. No critical areas of concern for plutonium glovebox applications of nylon 6-6 have been identified when considering exposure to mineral acid.

36 MATERIALS SCIENCE↗

Addressing as low as reasonably achievable (ALARA) issues: investigation of worker collective external and extremity dose data

Plutonium emits both neutrons and photons and when it is stored or handled inside a glovebox, both photons and neutrons are significant external radiation hazards. Doses to the extremities are usually dominated by gamma radiation in typical plutonium glovebox operations. Excess external dose can generates stochastic effects consisting of cancer and benign tumors in some organs. Direct doses from radiation sources external to the body are measured by thermoluminescent dosimeters (TLDs) placed on the glovebox worker between the neck and waist. Wrist dosimeters are used to assess externally penetrating radiation including neutrons and provide an estimate of neutron radiation exposure to the extremities. Both TLDs and wrist dosimeters are processed monthly for most glovebox workers. Here, worker collective extremity and external dose data have been analyzed to prevent and mitigate external radiation events through the use of Lean Manufacturing and Six Sigma business practices (LSS). Employing LSS, statistically significant variations (trends) are identified in worker collective extremity and external dose data. Finally, the research results presented in this paper are pivotal to the ultimate focus of this program, which is to minimize external radiation events.

61 RADIATION PROTECTION AND DOSIMETRY↗

Tritiated Sulfur Hexafluoride Disposition Strategies

Tritium (T 2 ) is a radioactive isotope of hydrogen that is produced in nuclear fission reactions and is often used in nuclear fusion reactions and accelerator-based applications for medical isotope production. As a hydrogen isotope, tritium can readily bind to hydroxyl radicals (OH), forming tritiated water (HTO or T 2 0), and to carbon atoms. Tritium decays to helium-3 ( 3 He) via beta-decay with max decay energy of 18.6 keV. While it is not an external radiation hazard, it can be an internal radiation hazard if tritium is inhaled, ingested, or absorbed through the skin. In applications where tritium is handled, tritium confinement is performed using different barriers to minimize releases to the environment. For gaseous (elemental), liquid (oxide), and metal (hydride) tritium, process piping and components provide the primary confinement function. Secondary tritium confinement is typically provided by inert (i.e. non-flammable gases such as nitrogen, argon, or helium) gloveboxes which are connected to a tritium stripper system. Primary tritium confinement barriers typically produce low volumes of high tritium concentrations of tritiated methane from carbon in steels or organic materials along with tritiated water/tritium oxide (e.g. HTO) and tritiated ammonia from reactions with oxygen and nitrogen. Tritium escaping primary confinement into secondary confinement atmospheres (e.g. gloveboxes) produce higher volumes of lower activity contamination than found in process piping. Tritium contamination also occurs by leaks or tritium permeation/diffusion through confinement materials. Tritium from inside primary confinement barriers will diffuse or leak out of the primary confinement barrier and usually into the air, if the system is inside an air hood or ventilated hot cell, or into the secondary confinement (e.g. glovebox) atmosphere which is either exhausted or stripped based on the function of the secondary confinement (glovebox) system. Accelerator based processes for medical isotope production represent an atypical tritium contamination challenge. In medical isotope production, deuterium supply gas is ionized and accelerated to a tritium gas target to produce neutrons that are then used to produce the medical isotopes through additional nuclear fission reactions. To create large voltage differentials for accelerator operations, an electrical insulation medium is needed to prevent or rapidly quench electric discharges. A common electrical insulation medium utilized in accelerator applications is sulfur hexafluoride (SF 6 ) gas. SF 6 has a high dielectric strength and allows for the construction of smaller accelerator systems compared to other electrical insulation mediums such as air or dry nitrogen. Due to tritium permeation/diffusion through accelerator process and confinement materials, there is the possibility that tritium can contaminate the electrical insulation medium of the accelerator. Tritium contaminated SF 6 creates a material without any obvious processes for managing the contamination, reuse, or disposal of the used SF 6 . This document will discuss possible management strategies for tritium contaminated SF 6 for accelerator-based processes for Molybdenum-99 (Mo-99) production.

07 ISOTOPE AND RADIATION SOURCES↗

Presentation to International Space University Students on g-LIMIT and STABLE-ATD Projects and Related Microgravity Vibration Isolation Topics

Vibration isolation is a necessity in the development of science in space and especially those experiments destined for operation on the International Space Station (ISS). The premise of microgravity scientific research is that in space, disturbances are minimized and experiments can be conducted in the absence of gravity. Although microgravity conditions exist in space, disturbances are still present in various forms and can be detrimental to the success of a microgravity experiment. Due to the plethora of disturbances and the various types that will occur on the space station, the microgravity community has elected to incorporate various means of isolating scientific payloads from these unwanted vibrations. Designing these vibration isolators is a crucial task to achieve true microgravity science. Since conventional methods of isolating payloads can achieve only limited isolation, new technologies are being developed to achieve the goal of designing a generic vibration isolation system. One such system being developed for the Microgravity Science Glovebox (MSG) is called g-LIMIT which stands for Glovebox Integrated Microgravity Isolation Technology. The g-LIMIT system is a miniaturized active vibration isolator for glovebox experiments. Although the system is initially developed for glovebox experiments, the g-LIMIT technology is designed to be upwardly scaleable to provide isolation for a broad range of users. The g-LIMIT system is scheduled to be flown on the UF-2 mission in August of the year 2000 and will be tested shortly thereafter. Once the system has been fully qualified, the hardware will become available for other researchers and will provide a platform upon which the goal of microgravity science can be achieved.

Alhorn, Dean↗

International Space Station Crew Restraint Design

With permanent human presence onboard the International Space Station (ISS), crews will be living and working in microgravity, dealing with the challenges of a weightless environment. In addition, the confined nature of the spacecraft environment results in ergonomic challenges such as limited visibility and access to the activity areas, as well as prolonged periods of unnatural postures. Without optimum restraints, crewmembers may be handicapped for performing some of the on-orbit tasks. Currently, many of the tasks on ISS are performed with the crew restrained merely by hooking their arms or toes around handrails to steady themselves. This is adequate for some tasks, but not all. There have been some reports of discomfort/calluses on the top of the toes. In addition, this type of restraint is simply insufficient for tasks that require a large degree of stability. Glovebox design is a good example of a confined workstation concept requiring stability for successful use. They are widely used in industry, university, and government laboratories, as well as in the space environment, and are known to cause postural limitations and visual restrictions. Although there are numerous guidelines pertaining to ventilation, seals, and glove attachment, most of the data have been gathered in a 1-g environment, or are from studies that were conducted prior to the early 1980 s. Little is known about how best to restrain a crewmember using a glovebox in microgravity. In 2004, The Usability Testing and Analysis Facility (UTAF) at the NASA Johnson Space Center completed development/evaluation of several design concepts for crew restraints to meet the various needs outlined above. Restraints were designed for general purpose use, for teleoperation (Robonaut) and for use with the Life Sciences Glovebox. All design efforts followed a human factors engineering design lifecycle, beginning with identification of requirements followed by an iterative prototype/test cycle. Anthropometric modeling was completed for the 5th percentile Asian female and the 95th percentile American male for all restraints. A series of three evaluations was performed onboard NASA's reduced gravity aircraft (KC-135). For all evaluations, participants performed representative tasks while being videotaped, and then completed a questionnaire following each flight day. The questionnaire included ratings scales and free format questions to assess topics such as comfort, stability provided, flexibility provided, etc. Results from the three flight evaluations are being used to develop the human factors design requirements for crew restraint concepts for 1) general purpose restraints, 2) teleoperation restraints and 3) glovebox restraints. The poster presentation will describe the detailed methodology used, results from each of the three evaluations, and the resulting human factors recommendations for the design of these restraints.

Whitmore, M.↗

A METHOD TO REDUCE BIOBURDEN IN ASTROMATERIALS CURATION FACILITIES WITHOUT INTRODUCING UNWANTED CONTAMINATION

Introduction: NASA curates its Astromaterials collections in cleanrooms that are carefully monitored for particulate, inorganic and trace metal contamination. Current sample collections are not particularly susceptible to organic contamination or biological alteration. However, new collections like those from the OSIRIS-REx and Hayabusa2 missions will have organic contamination requirements and are susceptible to biodegradation. It will be necessary sterilize or at least disinfect curation labs, as well as tools and equipment in a manner that does not introduce additional contamination and does not affect the samples 1. Current curation cleaning procedures utilize isopropyl alcohol which offers some bioburden reduction, but is not effective against spore-forming bacteria or fungal spores 2. We present a modified disinfection method that uses ultrapure hydrogen peroxide to reduce bioburden inside curation labs and glove boxes without introducing contamination or damaging curation equipment. We tested this method in the meteorite processing lab as well as on a glovebox being cleaned for use in processing ANGSA (Apollo Next Generation Sample Analysis) samples and present the results of those tests. We discuss the limitations of this method and describe potential situations in which it will not be applicable. The CDC guidelines for disinfection andsterilization in healthcare facilities discusses over 15different methods for reducing bioburden in hospitalsettings 3. The most common method, steamsterilization, is well suited to sterilizing curationprocessing tools but cannot easily be used to sterilizecleanroom surfaces or large equipment likegloveboxes. Chemical sterilization with bleach(NaOCl) is also a common strategy in healthcare andpharmaceutical settings that presents materialcompatibility issues as well as serious inorganiccontamination concerns for curation facilities.Introducing a new source of Na and Cl into curationlabs is not acceptable. Other chemical methods likeethylene oxide, formaldehyde, iodophors andquaternary ammonium compounds could introduceorganic and inorganic contamination. We chose tofocus on hydrogen peroxide because it is generallycompatible with commonly used curation materialslike stainless steel, aluminum and Teflon and becauseit decomposes to oxygen and water. The CDCguidelines for hydrogen peroxide specify using a 7.5wt% solution at 25 ̊C with a contact time of 30 minutesfor high level disinfection and 6 hours for sterilization.High level disinfection is defined as a technique thatwill kill all microorganisms except large numbers ofbacterial spores 3. Methods: We prepared a solution of 7.5 wt%hydrogen peroxide from a stock solution of ultrapure30 wt% peroxide (JT Baker) and curation gradeultrapure water. This ultrapure water is already used incuration cleaning procedures and thus is not consideredand additional source of contamination. We conducteda materials compatibility test by exposing unanodizedand anodized 6061 T6 Al alloy to the peroxide solutionfor up to six hours and periodically inspecting thesurfaces for visible defects. We used this peroxide todisinfect the floor of the meteorite processing lab andthe interior of a curation glovebox by exposing thesesurfaces to the peroxide solution for 30 min. Thesurfaces were swabbed with a dry macrofoam swabbefore (Puritan Brand 2518051PFRNDFD) and afterperoxide treatment to collect microbes present on thesurfaces. Microbes were extracted by sonication fromthe swab into 15 ml of PBS (phosphate buffered saline)and inoculated onto the following media: TSA (trypticsoy agar) BA (blood agar), R2A (Reasoners 2 agar),Potato Dextrose Agar, Saboraud Dextrose Agar andSaboraud Dextrose Agar with 0.1 mg/ mlchloramphenicol. Four TSA plates and two BA plateswere inoculated with 0.1 ml of PBS each andincubated at 35 and 37 for 48 hours. Two R2A°C°Cplates (0.1 ml of PBS each) were incubated at 25 .°CThe remaining plates were inoculated with 0.2ml ofPBS and incubated at 30 ̊C for seven days. Afterincubation bacterial and fungal isolates were countedand transferred to new plates for identification usingthe VITEK24 automated system or by sequencing aportion of the barcode gene (16S rRNA for bacteria,small subunit gene for fungi) on an ABI 3500 Sangersequencer. Negative controls consisted of swabs thatwere opened in the sampling environment andanalyzed alongside the experimental samples.Results: A 6 hour exposure to hydrogen peroxideresulted in visible pitting on un-anodized 6061 Al, butnot on anodized surfaces. No visible pitting occurredafter a 30 minute exposure. Therefore, we decided tolimit our experimental tests to 30 min. exposures. 17bacterial CFU (colony forming units) representing 4distinct organisms were isolated from the meteorite processing lab floor prior to hydrogen peroxidetreatment. We were unable culture any organisms afterperoxide treatment. In the glovebox we were able toculture three bacterial CFU representing three distinctspecies, including a spore forming bacterium prior todisinfection with peroxide. After the peroxidetreatment we were unable to culture any organisms.Routine monitoring of the meteorite processing lab andthe glovebox did not indicate any increase in unwantedinorganic contamination after these peroxidetreatments. Discussion: A 30 minute treatment with 7.5 wt%peroxide appears to be an effective method forreducing bioburden on typical cleanroom surfaces. Themethod does not introduce unwanted organic orinorganic contamination and is compatible withcommonly used curation materials like stainless steel,Teflon and anodized aluminum alloys. Special careshould be taken with un-anodized aluminum.Prolonged exposure to hydrogen peroxide can causepitting on this material. We recommend using thismethod to disinfect curation labs and equipment whenbiological alteration is a concern. This method iseffective at room temperature and cannot be used todisinfect labs and equipment where the ambienttemperature is < 0 ̊C. Astromaterials samples shouldbe removed from the area where disinfection is tooccur. Hydrogen peroxide is a powerful oxidizingagent and will react with any organic carbon present inthe sample. References: [1.] Mccubbin, F. M. et al.Sp. Sci Rev(2019) doi:10.1007/s11214-019-0615-9. [2.] Mogul, R.et al.Astrobiology 18, ast.2017.1814 (2018). [3.]Rutala, W. A. & Weber, D. J. Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008. [4.] Pincus, D. H. in Encyclopedia of Rapid Microbiological Methods (2005).

A. B. Regberg↗

In-situ gloveport glove leak tester

The invention provides a system for detecting leaks in glovebox gloves, the system having a first seal within a glovebox aperture; a second seal contacting exterior surfaces of a glovebox, wherein the exterior surfaces define a periphery of the aperture; a first fluid supply for circumferentially expanding the first seal against center facing surfaces of the aperture to a first pressure; a second fluid supply for inflating the glove to a second pressure; and a pressure gauge for detecting a pressure decrease of the second pressure. Also provided is an in situ method for detecting leaks in glove box gloves, the method having the steps of applying a radially directed force to inside surfaces of cuffs of the gloves to hermetically seal the gloves from the exterior of the glovebox, thereby establishing a seal; inflating the gloves to a pressure; and monitoring the pressure for any decrease in pressure.

42 ENGINEERING↗

PROTEC TM TEAR-OFFS: RESULTS OF LONG TERM TESTING

The Savannah River National Laboratory (SRNL) has completed a series of tests (Phases 1 and 2) to assess the potential use of a Mylar{reg_sign} tear-off system as a primary or secondary protective barrier to minimize acid etching ('frosting'), accidental scratching, and/or radiation damage for shielded cells, glovebox, and/or chemical hood windows. Conceptually, thin, multi-layered sheets of Mylar (referred to throughout this report as the ProTec{trademark} tear-off system) can be directly applied to the shielded cell, glovebox, or hood sash window to serve as a secondary (or primary) barrier. Upon degradation of visual clarity due to accidental scratching, spills/splatters, and/or radiation damage, the outer layer (or sheet) of Mylar could be removed refreshing or restoring the view. Due to the multilayer aspect, the remaining Mylar layers would provide continued protection for the window from potential reoccurrences. Although the concept of using a tear-off system as a protective barrier is conceptually enticing, potential technical issues were identified and addressed as part of this phased study to support implementation of this type of system in the Defense Waste Processing Facility (DWPF). Specific test conditions of interest to the DWPF included the performance of the tear-off system exposed to or under the following conditions: (1) acid(s) (concentrated (28.9 M) HF, concentrated (15.9M) HNO{sub 3}, 6M HCl, and 0.6M H{sub 3}BO{sub 3}); (2) base (based on handling of radioactive sludges with pH of {approx}12-13); (3) gamma radiation (due to radioactive sources or materials being used in the analytical cells); (4) scratch resistance (simulating accidental scratching with the manipulators); and (5) in-situ testing (sample coupons exposed to actual field conditions in DWPF). The results of the Phase 1 study indicated that the ProTec tear-off concept (as a primary or secondary protective barrier) is a potential technical solution to prevent or retard excessive damage that would result from acid etching, base damage (as a result of a sludge spill or splatter), gamma radiation damage, and/or accidental scratching (due to manipulator/tool contact). Although identified as a potential solution, the Phase 1 testing was relatively short-term with exposure times up to 1-2 months for the acid and gamma radiation tests. Phase 2 testing included longer exposure times for the acid resistance (up to 456 days) and gamma radiation exposure (700 days with a cumulative gamma dose of {approx}3.1 x 10{sup 5} rad) assessments. The tear-off system continued to perform well in these longer-term acid resistance testing and gamma exposure conditions. Complete removal of the tear-offs after these long-term exposure times indicate that not only could visual clarity be restored but the mechanical integrity could be retained. The results also provided insight into the ability of the ProTec tear-off system to withstand the chemical and physical abuses expected in off-normal shielded cells operations. The conceptual erasing of scratches or marks by excessive manipulator abuse was demonstrated in the SRNL Shielded Cells mock-up facility through the removal of the outer layer tear-off with manipulators. In addition, the Phase 2 testing included an in-situ assessment of a prototype tear-off system in the DWPF Sampling Cells where the system was exposed to actual field conditions including radioactive sources, acidic and basic environments, dusting, and chemical cleaning solutions over a 5-6 month period. DWPF personnel were extremely satisfied with the performance (including the successful removal of 3 layers with manipulators) of the ProTec tear-off system under actual field conditions. The successful removal of the outer layer tear-offs with the manipulator, using tabs not specifically designed for remote operations, demonstrates that the system is 'manipulator-friendly' and could be implemented in a remote environment. The ability to remove the outer layer tear-off not only regains visual clarity but also reduces waste disposal volumes (i.e., disposal of a thin sheet of Mylar which is 'collapsible' versus the bulk disposal of a rigid Lexan{reg_sign} sheet (alpha shield) or glovebox/sash window) which is more cost effective. The tear-off system could also reduce the number of cell entries needed to replace the Lexan sheet and increase the time interval between glovebox/sash window replacements, which can be costly and time consuming. Although the primary focus of this study addresses the application of the ProTec tear-off system to shielded cells windows, the concept is also potentially applicable to glovebox and hood sash windows. In fact, the tear-off concept is potentially applicable to any system where visual clarity is compromised given the environmental conditions of the test. In addition, the tear-offs could be applied to walls or shelves where a protective barrier would reduce deterioration or discoloration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Repackaging Rocky Flats Legacy Transuranic Waste

Repackaging legacy Transuranic (TRU), Transuranic Mixed (TRM), Low Level Waste (LLW), and Low Level Mixed (LLM) waste requires good characterization skills and the ability to adapt to less than ideal conditions. Repackaging legacy waste in a facility that is not undergoing Decontamination and Decommission (D and D) is optimum. However, repackaging any waste in a D and D facility, under cold and dark conditions, can be difficult. Cold and dark conditions are when the heating and air conditioning are no longer in service and the lighting consists of strands of lights hung throughout each of the rooms. Working under these conditions adds an additional level of stress and danger that must be addressed. The use of glovebags was very useful at Rocky Flats during the D and D of many buildings. Glovebags can be adapted for many different types of wastes and unusual conditions. Repackaging of legacy TRU waste, in a D and D facility, can be accomplished safely and cost effectively with the use of glovebags. In conclusion: the use of glovebags to repackage legacy TRU, TRM, LLW, or LLM waste was done safely and cost effectively at Rocky Flats. The cost of using glovebags was minimal. Glovebags are easily adaptable to whatever the waste configuration is. The use of glovebags, for repackaging of Legacy waste, allows D and D efforts to stay on schedule and on task. Without the use of glovebags, additional gloveboxes would have been required at Rocky Flats. Larger items, such as the HEPA filters, would have required the construction of a new large item repackaging glovebox. Repackaging in glovebags allows the freedom to either locate the glovebag by the waste or locate the glovebag in a place that least impacts D and D efforts. The use of glovebags allowed numerous configurations of waste to be repackaged without the use of gloveboxes. During the D and D of the Rocky Flats facility, which was in a cold and dark stage, D and D work was not impacted by the repackaging activity. Glovebags work well in facilities that are in the process of D and D or still in full operations because glovebags are very safe and cost effective.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Develop and Manufacture an airlock sliding tray

The goal of this project is to continue to develop an airlock sliding tray and then partner with an industrial manufacturing company for production. The sliding tray will be easily installed into and removed from most glovebox airlocks in a few minutes. Technical Approach: A prototype of a sliding tray has been developed and tested in the LANL cold lab and 35 trays are presently being built for the plutonium facility (PF-4). The current, recently approved design works for a 14-inch diameter round airlock and has a tray length of approximately 20 inches. The grant will take the already tested and approved round technology and design for the square airlock. These two designs will be suitable for the majority of the existing airlocks in the multitude of DOE facilities. Partnering with an external manufacturer will allow for production of the airlock trays at a much lower cost and increase the availability of the product for all DOE sites. Project duration is estimated to be 12-13 months. Benefits: The purpose of the airlock sliding trays is fourfold: 1) Mitigate risk of rotator cuff injuries, 2) Improve ALARA, 3) Reduce risk of glovebox glove breaches and glove punctures, and 4) Improve worker comfort. I have had the opportunity to visit many other DOE facilities including Savannah, Y-12, ORNL, Sandia, and Livermore for assistance with ergonomic problems and/or injuries. All of these sites would benefit from the airlock sliding tray and I can assume all other DOE facilities with gloveboxes built prior to 1985 could also use the sliding trays.

42 ENGINEERING↗

Comparative Approach for Evaluating the Containment Performance of Legacy NM Storage Containers

Many different types of nuclear material storage containers are used throughout TA-55 and specifically PF-4, in some instances these containers are used outside of engineering control barriers in most cases these barriers are gloveboxes. When a container is used outside of a glovebox or open front hood the container itself is relied upon as the primary engineering control barrier for the user. For this reason a process must be established in order to evaluate Non- Manual Compliant or NMC containers used outside of a glovebox in a comparative approach against Manual compliant containers. Legacy containers are typically understood to be non-standards packaged prior to 1998. For the purposes of this document “legacy” refers to any non-Manual compliant containers.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MIL-C-38999 electrical connector applicability tests for on-orbit EVA satellite servicing

MIL-C-38999 electrical connectors were tested for their applicability to the on-orbit EVA satellite servicing environment. The investigation provided a methodical approach to the evaluation of the human-machine interface of these connectors. The physical characteristics of thirty-five MIL-C-38999 connectors were tested in two simulated space environments, the NASA Johnson Space Center Weightless Environment Training Facility and an evacuated glovebox which incorporated the Extravehicular Maneuvering Unit series 3000 gloves. Physical characteristics of the connectors were documented, including operating torque and work profiles. STS crewmembers tested a select group of connectors in two WETF test and subjectively ranked the G&H PMM Wing-Tab connectors as most applicable to the on-orbit servicing environment. WETF performance times indicated that the G&H PMM Wing-Tab connector had the fastest operating time. The evacuated glovebox participants ranked the G&H 64600 Wing-Tab and the G&H PMM Wing-Tab connectors as those most applicable to the on-orbit servicing environment. During the evacuated glovebox tests, the G&H 64600 Wing-Tab connector had the fastest operating time.

Griffin, Thomas J.↗