Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAS STREAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Solar-thermal reaction processing

In an embodiment, a method of conducting a high temperature chemical reaction that produces hydrogen or synthesis gas is described. The high temperature chemical reaction is conducted in a reactor having at least two reactor shells, including an inner shell and an outer shell. Heat absorbing particles are included in a gas stream flowing in the inner shell. The reactor is heated at least in part by a source of concentrated sunlight. The inner shell is heated by the concentrated sunlight. The inner shell re-radiates from the inner wall and heats the heat absorbing particles in the gas stream flowing through the inner shell, and heat transfers from the heat absorbing particles to the first gas stream, thereby heating the reactants in the gas stream to a sufficiently high temperature so that the first gas stream undergoes the desired reaction(s), thereby producing hydrogen or synthesis gas in the gas stream.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

99Tc immobilization from off-gas waste streams using nickel-doped iron spinel

Technetium-99 (99Tc) incorporation within stable spinel phases is a novel method for 99Tc removal and immobilization from waste streams. In this study, transformation of Ni-doped Fe(OH)2(s) to spinel minerals, e.g. trevorite (NiFe2O4), is explored as a method for removing 99Tc from Hanford Waste Treatment and Immobilization Plant (WTP) primary off-gas waste stream simulant. The Fe(OH)2(s) transformation process was found to reduce 99Tc(VII) to 99Tc(IV) and incorporate reduced Tc(VI) into the produced spinel simultaneously. Nickel doping was applied in the mineral transformation to inhibit potential reoxidation of 99Tc(IV). Solid phase characterization by XRD and XANES confirmed the formation of nickel substituted ferric-spinel, and suggest incorporation of 99Tc(IV) in the final spinel. Furthermore, in the primary off-gas stream, which contains both redox-sensitive contaminants Cr(VI) and 99Tc(VII), results from solution analysis and solid digestion indicate that nearly 100% Cr and over 80% 99Tc can be simultaneously removed by adding Fe(OH)2(s) to solution with a solid to solution ratio of 5 g/L under near neutral and alkaline conditions. The 99Tc removal approach developed herein provides an alternative treatment method to eliminate the proposed recycle process of the off-gas waste stream, which ultimately can reduce WTP mission cost and operation time.

Wang, Guohui↗

Iodine Retention of Long-chain Organic Iodides on Silver-based Sorbents under DOG and VOG Conditions

The aqueous reprocessing of used nuclear fuel releases four key volatile radionuclides ( 3 H, 14 C, 85 Kr, and 129 I) from the used fuel into the off-gas streams of a reprocessing facility. Some semi-volatile radionuclides such as 106 Ru may also be released into the gas streams. Compliance with US regulations may require removal of these radionuclides from the off-gas streams before their discharge to the environment (Jubin et al. 2017). Iodine is released during multiple unit operations within a plant and can be found in gas streams such as the shear off-gas, dissolver off-gas, vessel off-gas (VOG), and waste solidification off-gas. To achieve DFs >1,000, treatment of the plant off-gas streams must include, at minimum, removal of both the dissolver off-gas and VOG. A 2015 analysis showing that the speciation of iodine in the VOG is primarily composed of organic alkyl iodides and that abatement technology for organic iodides is not well developed has produced increased interest in removing iodine from VOG. The lack of knowledge surrounding iodine removal from the VOG prompted the Office of Nuclear Energy within the US Department of Energy to initiate experimental efforts targeted at understanding organic iodide removal from prototypic VOG streams. In 2018 a joint test plan was developed and issued by Oak Ridge National Laboratory and Idaho National Laboratory. This test plan is intended to guide a multiyear experimental effort that will provide substantial amounts of information about the removal of organic iodides from VOG streams. This document reports on the progress of Idaho National Laboratory and Oak Ridge National Laboratory in the execution of the joint test plan as of the end of fiscal year 2019. Silver-based sorbents are the primary removal technology being characterized, and this report includes data on iodine adsorption by reduced silver-exchanged mordenite (also called silver-exchanged zeolite [AgZ]) (as a baseline iodine sorbent) and silver-functionalized silica aerogel (AgAero or Ag Aerogel) (as an advanced iodine sorbent). Conclusions are preliminary in nature and reflect the ongoing execution of the test plan through close collaboration between the two laboratories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ammonia Permeation Through Inorganic Membranes

Moisture probes are used in the tritium facility to measure the moisture content of the gas stream. When tritium reacts with nitrogen to form ammonia, the ammonia gas damages the sensitive moisture probe. The gas stream tested during this experiment for moisture probe protection is composed of nitrogen and argon gas in conjunction with ammonia and water vapor. The gas stream is filtered through an inorganic membrane due to the high reactivity of tritium and a residual gas analyzer (RGA) is used to measure the ammonia and water vapor in the gas stream, as well as the permeability of nitrogen and argon through the inorganic membranes. The membranes tested were boron nitride and silver. The permeability was compared for each membrane at different pressures and flow rates. Fourier-transformed infrared spectroscopy (FT-IR) was used to compare the membranes before and after ammonia permeation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Organic Iodine Adsorption by AgZ under Prototypical Vessel Off-Gas Conditions

U.S. regulations will require the removal of 129 I from the off-gas streams of any used nuclear fuel (UNF) reprocessing plant prior to discharge of the off-gas to the environment. Multiple off-gas streams within a UNF reprocessing plant combine prior to release, and each of these streams contains some amount of iodine. For an aqueous UNF reprocessing plant, these streams include the dissolver off-gas, the cell off-gas, the vessel off-gas (VOG), the waste off-gas and the shear off-gas. To achieve regulatory compliance, treatment of multiple off-gas streams within the plant must be performed. Preliminary studies have been completed on the adsorption of I 2 onto silver mordenite (AgZ) from prototypical VOG streams. The study reported that AgZ did adsorb I 2 from a prototypical VOG stream, but process upsets resulted in an uneven feed stream concentration. The experiments described in this document both improve the characterization of I 2 adsorption by AgZ from dilute gas streams and further extend it to include characterization of the adsorption of organic iodides (in the form of CH 3 I) onto AgZ under prototypical VOG conditions. The design of this extended duration testing was such that information about the rate of adsorption, the penetration of the iodine species, and the effect of sorbent aging on iodine removal in VOG conditions could be inferred.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance Criteria for Capture and/or Immobilization Technologies (Revision 1)

The capture and subsequent immobilization of regulated volatile radionuclides from the off-gas streams of a used nuclear fuel (UNF) reprocessing facility has been a topic of substantial research interest for the US Department of Energy and its international counterparts. Removal of specific radionuclides from the plant effluent streams before discharge to the environment is required to meet regulations set forth by the US Environmental Protection Agency. Upon removal, the radionuclides, as well as associated sorbents that cannot be regenerated in a cost-effective manner, are destined for conversion to a waste form. Research in separation and capture methodologies has included a wide range of technology types, and studies of waste forms are correspondingly diverse. In considering the future development and implementation of both sorbents and waste forms, it is necessary to identify benchmark measures of performance to objectively evaluate each sorbent system or waste form. Sets of performance criteria and associated metrics have been developed for sorbent and waste form evaluation. These criteria address physical, radiological, and chemical characteristics, technical practicality, technical maturity, cost, and, for sorbents, system performance. The criteria and metrics appear to be robust and should be applicable despite the eventual waste classification (as either high- or low-level waste). They are flexible enough to address both aqueous reprocessing and electrochemical reprocessing of UNF. These criteria sets can serve as tools to evaluate performance at multiple stages within the development process, and in this revision (Revision 1) they have been used to assess technologies relating to krypton/xenon separations and iodine capture from off-gas streams arising from UNF reprocessing. Assessment of krypton/xenon separations using engineered forms of two zeolite minerals (silver mordenite and hydrogen mordenite in a polyacrylonitrile-based binder [AgZ-PAN/HZ-PAN]) found that the zeolite-based separation is relatively advanced in its development, but several key issues require resolution. First, desorption processes for both krypton and xenon require refinement to provide an understanding of the product purity that can be achieved. Second, adsorption rate data is needed in order to calculate the bed depth required for effective separation. Finally, it is strongly recommended that a technical review of krypton/xenon separation by AgZ-PAN/HZ-PAN be performed to synergize available data and assess the cost savings and operational benefits that may be realized from implementation of this technology. Assessment of metal organic frameworks (MOFs) for their use in the separation of krypton/xenon found that the ideal separation would be performed using a single-column system with a MOF selective for krypton over xenon. A robust research effort should work to identify a krypton-selective MOF designed to operate at temperatures of approximately 0°C or higher, which could be preferred over cryogenic krypton/xenon capture for used fuel reprocessing off-gas streams. In the case of the CaSDB-MOF (the most well-understood xenon sorbent to date), two issues are judged of high importance. First, xenon breakthrough capacity for the CaSDB-MOF in prototypical conditions should be determined. Preliminary research indicates that breakthrough may be near immediate, presenting a substantial obstacle in separative system design. Second, development of desorption methodology should be performed to determine regeneration time, energy requirements, and the product stream composition. Silver-based sorbents (AgZ and AgAero) for use in iodine capture from the dissolver off-gas were evaluated against the established criteria. These sorbents are significantly better understood for this application as a result of research efforts over the past decade. The potential implementation of AgAero at a large scale is hindered by its physical degradation by components of the dissolver off-gas stream. Less is known about the adsorption of iodine by these sorbents from other off-gas streams in the plant. Initial experimental efforts have been closely coordinated in an effort to understand organic iodine (such as would be found in the vessel off-gas) adsorption by AgZ and AgAero. Future work should expand this experimental program, and analysis of other reprocessing facility off-gas streams such as the vitrification off-gas stream should be conducted to better understand other potential applications for iodine sorbents. A review of iodine waste form development shows that this area is diverse and that multiple promising waste forms have been identified for the immobilization of radioactive iodine. Efforts related to the direct conversion of iodine sorbents (including AgZ and AgAero) should be continued because of the advantages of direct conversion in a waste management strategy and other sorbents should continue to be advanced as merited.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

System and method for sulfur recapture in a chemical looping system

A method for recapturing sulfur in a chemical looping system includes receiving a flue gas stream containing a sulfur-containing species, reducing a temperature of the flue gas stream, introducing a calcium-based makeup material to the reduced temperature flue gas stream, capturing the sulfur-containing species from the reduced temperature flue gas stream, and recycling the sulfur-containing species to a reducer of the chemical looping system.

Turek, David Gordon↗

Parametric Study of Solid Amine Sorbents for the Capture of Carbon Dioxide

Solid amine sorbents were prepared using mixtures of linear and branched primary, secondary, and tertiary amines. These amines were immobilized within polystyrene (PS)-, silicon dioxide (SiO 2 )-, or polymethylmethacrylate (PMMA)-based substrates at various weight ratios. Testing was conducted in various reactor systems, where the reactive water required for the capture of carbon dioxide (CO 2 ) was tracked during the adsorption/desorption cycles by mass spectrometer gas analysis. The water management for these sorbents was quantified and used to assess the technical feasibility of the operating conditions for the capture of CO 2 from simulated flue gas streams. In addition, the heats of reaction and performance capture loading capacities of these sorbents were also determined by differential scanning calorimetry (DSC) and thermogravimetric analyses (TGAs), respectively, in both dry and humidified CO 2 gas streams. The regenerable solid amine sorbents investigated in this study exhibit acceptable CO 2 -capture loading capacities of 2.5-3.5 mol of CO 2 /kg of sorbent by TGA and a laboratory-scale fixed-bed reactor. These sorbents were stable over the adsorption/desorption temperature range of 25-105° C for 10-cyclic tests. According to the DSC analysis, the heat of reaction generated by these sorbents was in the range of 400-600 Btu/lb. CO 2 , which will require a reactor with heat management capabilities.

01 COAL, LIGNITE, AND PEAT↗

Aging of Iodine-Loaded Silver Mordenite in NO2

Used nuclear fuel facilities need to control and minimize radioactive emissions. Off-gas systems are designed to remove radioactive contaminants, such as 85Kr, 14C, 3H, and 129I. In an off-gas system, any capture material will be exposed to a gas stream for months at a time. This gas stream may be at elevated temperature and could contain water, NOx gas, or a variety of other constituents comprising the dissolver off-gas stream in a nuclear fuel reprocessing plant. For this reason, it is important to evaluate the effects of long-term exposure, or aging, on proposed capture materials. One material under consideration is reduced silver mordenite (Ag0Z), which is recognized for its efficient iodine capture properties. Iodine is immobilized on Ag0Z as AgI, a solid with low volatility (m.p. ≥ 500°C). The aim of this study was to determine whether extended aging at elevated temperature in a nominally 2% NO2 environment would result in a loss of immobilized iodine from this material due to either physical or chemical changes that might occur during aging. Charges of iodine-loaded reduced silver mordenite (I2-Ag0Z) were exposed to a 2% NO2 environment for 1, 2, 3, and 4 months at 150°C, then analyzed for iodine losses The aging study was completed successfully. The material did not visibly change color or form. The results demonstrate that no significant iodine loss was observed over the course of 4 months of 2% NO2 aging of I2-Ag0Z at elevated temperature within the margin of error and the variability (~10%) in the loading along the beds. This provides assurance that iodine will remain immobilized on Ag0Z during extended online use in an off-gas capture treatment system. Future tests should expose I2-Ag0Z to progressively more complex feed gases in an effort to accurately replicate the conditions expected in a reprocessing facility.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Testing of an Iodine and Tritium Capture System for an NO₂-Based Tritium Pretreatment Process

The reprocessing of used nuclear fuel would release volatile radionuclides into the off-gas streams of a processing plant, including ³H, ¹⁴C, ⁸⁵Kr, and ¹²⁹I. One potential simplification to the management of the off-gas streams could be achieved through an efficient tritium pretreatment (TPT) step in which the UO₂ fuel is oxidized by either air or NO₂ before dissolution. The oxidation of the UO₂ fuel matrix will result in the release of tritium from the fuel. Upfront release of tritium from the fuel in a pretreatment step with subsequent tritium abatement can minimize or eliminate the distribution of tritium throughout a plant. This can decrease or eliminate the need for tritium capture on multiple off-gas streams and prevent distribution to the aqueous inventory. The use of NO₂ as the oxidant in an advanced tritium pretreatment (ATPT) allows for the oxidation to be performed at lower temperatures and may also result in the quantitative release of iodine from the fuel. The ATPT off-gas will contain up to 75 vol% NO₂ gas. Spencer et al. identified the most promising iodine sorbent as silver nitrate-impregnated alumina (AgA) and the most promising tritium sorbents as 3Å molecular sieve (3Å MS) and silica gel for radionuclide capture from ATPT off-gas streams. An initial series of tests were conducted in fiscal years 2017–2018 with the intent of demonstrating the recovery of iodine and tritium using these sorbents from a recirculating gas stream that simulated the NO₂ recycle loop envisioned for the ATPT system. These initial tests showed low tritium recoveries and significant variations in the iodine recovery on the AgA. Ultimately it was concluded, following disassembly of the system, that corrosion within the system was partially the cause of the poor recovery of both species. All components of that system were disposed of at the end of the analysis. One of the conclusions drawn from the initial tests pointed to the reconsideration of the materials of construction. Based on that recommendation a new test bed for the advanced TPT off-gas system, that addresses the issues identified in the fiscal years 2017 and 2018 scoping tests, was designed and constructed. The test bed used high nickel alloys wherever possible to address the previously observed corrosion issues, a redesigned surge tank to permit ease of purging, an improved feed injection system and a more modular system design that allowed testing of incremental increases in system complexity to allow the isolation of any element that results in changes to recovery of target species. Accompanying that design, a multifaceted test plan was completed. The overarching goals of this test series were two-fold. The first goal was to demonstrate the ability to recover both the iodine and tritium that would be released during TPT in a manner that the releases from the fuel can be quantified. The second goal was to demonstrate that the combined recovery system could operate in any of the three proposed TPT modes (once-through air or O₂, recirculating air or O₂, or recirculating NO x ). A total of 22 tests were completed. Ten tests examined tritium behavior under varying operating parameters, 8 tests examined iodine behavior under varying operating parameters, and 4 tests examined both tritium and iodine behavior. Silica gel was used for the tritium sorbent, and AgA or Ag-mordenite (AgZ) was used as the iodine sorbent. The following conclusions were drawn: Full recovery is achieved for both sorbates when no sorbent is in place indicating no accumulation within the test system. In even the simplest of the configurations (i.e., no sorbents in the columns), iodine is more difficult to transport and recover from the system than tritium. Analysis of the AgA iodine sorbent beds from the integrated tritium and iodine tests indicate quantitative iodine recovery can be achieved (within anticipated experimental errors). This system may provide a means for the quantification of the iodine released by the ATPT process within the experimental uncertainties. This would support 0.33 to 1.00 kg demonstrations of the ATPT process with actual used nuclear fuel. Iodine penetrated further into AgZ than into AgA when operated in gas recirculation mode. Tritium adsorbs to and cannot be fully recovered from the 10-cm column of silica gel at regeneration temperatures up to 140 °C.; Tritium adsorbs to and cannot be recovered from the 10-cm column of AgA at desorption temperatures up to 200 °C. Co-adsorbed tritium was recovered to a greater extent from AgZ than from AgA, but recovery was not complete. No visible corrosion was observed in the test system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Tritium Distribution and Capture Requirements for UNF Reprocessing

Four radionuclides have been identified as being sufficiently volatile in reprocessing of nuclear fuel that their gaseous release needs to be controlled to meet U.S. regulatory requirements. These radionuclides are {sup 3}H, {sup 14}C, {sup 85}Kr, and {sup 129}I. Previous studies have discussed the need for treating off-gas streams to control {sup 3}H, {sup 14}C, {sup 85}Kr, and {sup 129}I from the reprocessing of used nuclear fuel (UNF) and the regulations that set the limits for releases from such a facility. These regulations ultimately prescribe the decontamination factor (DF) that must be met in the facility. Jubin et al. examined the role of off-gas pathways since the gaseous radionuclides can partition to different reprocessing off-gas streams. Based on this report and subsequent analysis, the required DF for {sup 129}I could be 1000 to 3000. The required DF for {sup 3}H could be as high as 200, depending on the age of the fuel processed. The DF for {sup 85}Kr could be up to ∼35, also depending on fuel age. The required DF for {sup 14}C is 1 in many cases (no treatment required) but could be higher in specific cases. While iodine has been the focus of a number of studies due to the high DF requirements on multiple escape pathways, it is clear from the studies noted above that the control of tritium will also be a significant issue for future reprocessing plants, especially if processing relatively short-cooled fuels (<10 yr post reactor discharge). Tritium contained in a UNF matrix will be released into the liquid and off-gas streams during fuel reprocessing. The amount released into the process streams is a function of the type and burnup of the fuel processed, and the chemical processes employed within the reprocessing plant. Previous studies have examined the tritium capture requirements for the reprocessing facility assuming that all of the tritium is volatilized in the head-end operations, i.e., tritium pretreatment is employed and tritium is completely released from the cladding. This is clearly a worst case scenario from the standpoint of the amount of tritium that could be released, but the scenario tends to limit the release pathway to the head-end off-gas stream. In this analysis, the volume of HTO and the HTO to H{sub 2}O ratio for each of the three plant-wide tritium DFs were determined. The overall amount of HTO that had to be captured from the off-gas streams was virtually the same for the three DF cases evaluated; 98%, 99% and 99.5% of the tritium in the fuel entering the plant needed to be recovered for overall plant DFs of 50, 100 and 200, respectively. The use of the 'tritium barrier' to limit the spread of HTO from the head-end systems to the balance of the plant results in an increase in tritiated waste concentration in the head-end recycle acid systems which results in a decrease in the total amount of HTO + H{sub 2}O that must recovered from the gaseous effluent from the plant. The use of the 'tritium barrier' decreases the waste volume due to the higher HTO:H{sub 2}O ratio in the treated off-gas stream. The results also show that increasing the acid recycle percentage increases the concentration of HTO within the UNF reprocessing plant. This is then manifested in less HTO + H{sub 2}O that must be recovered from the gaseous effluents. Finally, the application of tritium recovery on the recycle acid reduces the HTO concentration in the recycle acid stream and generates a separate HTO + H{sub 2}O stream that must be managed. However, the resulting volume of tritium-containing waste generated plant-wide is a function of the selectivity of the tritium recovery system and the ability of the tritium recovery system to limit the accumulation of HTO in the recycle acid such that the HTO + H{sub 2}O recovered from gaseous effluents does not contribute significantly to the overall tritium waste volume. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reformer assisted lean NO.sub.x catalyst aftertreatment system and method

A method and apparatus for catalytically processing a gas stream passing therethrough to reduce the presence of NO.sub.x therein, wherein the apparatus includes a first catalyst composed of a silver-containing alumina that is adapted for catalytically processing the gas stream at a first temperature range, a second catalyst composed of a copper-containing zeolite located downstream from the first catalyst, wherein the second catalyst is adapted for catalytically processing the gas stream at a lower second temperature range relative to the first temperature range, a hydrocarbon compound for injection into the gas stream upstream of the first catalyst to provide a reductant, and a reformer for reforming a portion of the hydrocarbon compound into H.sub.2 and/or oxygenated hydrocarbon for injection into the gas stream upstream of the first catalyst. The second catalyst is adapted to facilitate the reaction of reducing NOx into N.sub.2, whereby the intermediates are produced via the first catalyst reacting with NOx and hydrocarbons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Circumbinary ring, circumstellar disks, and accretion in the binary system UY Aurigae

Recent exo-planetary surveys reveal that planets can orbit and survive around binary stars. This suggests that some fraction of young binary systems which possess massive circumbinary (CB) disks may be in the midst of planet formation. However, there are very few CB disks detected. We revisit one of the known CB disks, the UY Aurigae system, and probe {sup 13}CO 2-1, C{sup 18}O 2-1, SO 5(6)-4(5) and {sup 12}CO 3-2 line emission and the thermal dust continuum. Our new results confirm the existence of the CB disk. In addition, the circumstellar (CS) disks are clearly resolved in dust continuum at 1.4 mm. The spectral indices between the wavelengths of 0.85 mm and 6 cm are found to be surprisingly low, being 1.6 for both CS disks. The deprojected separation of the binary is 1.''26 based on our 1.4 mm continuum data. This is 0.''07 (10 AU) larger than in earlier studies. Combining the fact of the variation of UY Aur B in R band, we propose that the CS disk of an undetected companion UY Aur Bb obscures UY Aur Ba. A very complex kinematical pattern inside the CB disk is observed due to a mixing of Keplerian rotation of the CB disk, the infall and outflow gas. The streaming gas accreting from the CB ring toward the CS disks and possible outflows are also identified and resolved. The SO emission is found to be at the bases of the streaming shocks. Our results suggest that the UY Aur system is undergoing an active accretion phase from the CB disk to the CS disks. The UY Aur B might also be a binary system, making the UY Aur a triple system.

79 ASTRONOMY AND ASTROPHYSICS↗

Catalyzed CO.sub.2-transport membrane on high surface area inorganic support

Disclosed are membranes and methods for making the same, which membranes provide improved permeability, stability, and cost-effective manufacturability, for separating CO.sub.2 from gas streams such as flue gas streams. High CO.sub.2 permeation flux is achieved by immobilizing an ultra-thin, optionally catalyzed fluid layer onto a meso-porous modification layer on a thin, porous inorganic substrate such as a porous metallic substrate. The CO.sub.2-selective liquid fluid blocks non-selective pores, and allows for selective absorption of CO.sub.2 from gas mixtures such as flue gas mixtures and subsequent transport to the permeation side of the membrane. Carbon dioxide permeance levels are in the order of 1.0.times.10.sup.-6 mol/(m.sup.2sPa) or better. Methods for making such membranes allow commercial scale membrane manufacturing at highly cost-effective rates when compared to conventional commercial-scale CO.sub.2 separation processes and equipment for the same and such membranes are operable on an industrial use scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Catalyzed CO.sub.2-transport membrane on high surface area inorganic support

Disclosed are membranes and methods for making the same, which membranes provide improved permeability, stability, and cost-effective manufacturability, for separating CO.sub.2 from gas streams such as flue gas streams. High CO.sub.2 permeation flux is achieved by immobilizing an ultra-thin, optionally catalyzed fluid layer onto a meso-porous modification layer on a thin, porous inorganic substrate such as a porous metallic substrate. The CO.sub.2-selective liquid fluid blocks non-selective pores, and allows for selective absorption of CO.sub.2 from gas mixtures such as flue gas mixtures and subsequent transport to the permeation side of the membrane. Carbon dioxide permeance levels are in the order of 1.0.times.10.sup.-6 mol/(m.sup.2sPa) or better. Methods for making such membranes allow commercial scale membrane manufacturing at highly cost-effective rates when compared to conventional commercial-scale CO.sub.2 separation processes and equipment for the same and such membranes are operable on an industrial use scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Aging Processes of Silver Mordenite and Silver Functionalized Aerogel in Dry Air, Humid Air and NO/N{sub 2}

One major problem in the treatment of nuclear-fuel reprocessing off-gas streams is the loss of capacity of the adsorbents exposed to off-gas streams containing air, I{sub 2} vapor, H{sub 2}O vapor, NO and NO{sub 2} over extended periods of time. These aging processes decrease the adsorption capacity of the reduced silver exchanged mordenite (Ag{sup 0}Z) and silver functionalized silica aerogel (Ag{sup 0}-aerogel) columns during the long processing time of iodine adsorption. Significant work has been performed over the past few years at ORNL on Ag{sup 0}Z and Ag{sup 0}-aerogel aging. The Ag{sup 0}Z and Ag{sup 0}-aerogel were aged in 4 different gas streams at 150 deg. C for periods of time up to 6 months. The aging samples were then loaded with I{sub 2} to determine the capacity loss after the aging. The results are summaries in Tab. 1. It was found that both Ag{sup 0}Z and Ag{sup 0}-aerogel had different amounts of capacity loss in different gases. For example, 40% and 22% capacity loss were observed for Ag{sup 0}Z and Ag{sup 0}-aerogel when aged in dry air for 6 months, while 78% and 43% capacity loss were observed when aged in 1% NO{sub 1} for 2 months. In addition, it was found that Ag{sup 0}Z and Ag{sup 0}-aerogel had a different capacity loss when aged at the same conditions. For example, after aged in 2% NO{sub 2} for 2 months, Ag{sup 0}Z lost 30% iodine capacity, but there was no capacity loss for Ag{sup 0}- aerogel. The differences in capacity loss should be due to different aging processes occurred when Ag{sup 0}Z and Ag{sup 0}- aerogel were exposed to different gases. The mechanisms of the aging processes have not been determined and need to be studied with proper chemical and physical characterization methods. Towards this objective, experimental work is proposed and on-going to obtain data to determine the mechanisms of the aging processes of Ag{sup 0}Z and Ag{sup 0}-aerogel in different aging gas streams. In addition, models will be developed to describe the deactivation process of the adsorbents when exposed to off gases. The deactivation model will be included in the transport models for predicting the adsorption processes over these long-time periods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optimized heat exchange in a CO2 de-sublimation process

The present invention is a process for removing carbon dioxide from a compressed gas stream including cooling the compressed gas in a first heat exchanger, introducing the cooled gas into a de-sublimating heat exchanger, thereby producing a first solid carbon dioxide stream and a first carbon dioxide poor gas stream, expanding the carbon dioxide poor gas stream, thereby producing a second solid carbon dioxide stream and a second carbon dioxide poor gas stream, combining the first solid carbon dioxide stream and the second solid carbon dioxide stream, thereby producing a combined solid carbon dioxide stream, and indirectly exchanging heat between the combined solid carbon dioxide stream and the compressed gas in the first heat exchanger.

42 ENGINEERING↗

Effect of Coal Contaminants on Solid Oxide Fuel System Performance and Service Life

The U.S. Department of Energy's SECA program envisions the development of high-efficiency, low-emission, CO{sub 2} sequestration-ready, and fuel-flexible technology to produce electricity from fossil fuels. One such technology is the integrated gasification-solid oxide fuel cell (SOFC) that produces electricity from the gas stream of a coal gasifier. SOFCs have high fuel-to-electricity conversion efficiency, environmental compatibility (low NO{sub x} production), and modularity. Naturally occurring coal has many impurities and some of these impurities end in the fuel gas stream either as a vapor or in the form of fine particulate matter. Establishing the tolerance limits of SOFCs for contaminants in the coal-derived gas will allow proper design of the fuel feed system that will not catastrophically damage the SOFC or allow long-term cumulative degradation. The anodes of Ni-cermet-based SOFCs are vulnerable to degradation in the presence of contaminants that are expected to be present in a coal-derived fuel gas stream. Whereas the effects of some contaminants such as H{sub 2}S, NH{sub 3} and HCl have been studied, the effects of other contaminants such as As, P, and Hg have not been ascertained. The primary objective of this study was to determine the sensitivity of the performance of solid oxide fuel cells to trace level contaminants present in a coal-derived gas stream in the temperature range 700 to 900 C. The results were used to assess catastrophic damage risk and long-term cumulative effects of the trace contaminants on the lifetime expectancy of SOFC systems fed with coal-derived gas streams.

01 COAL, LIGNITE, AND PEAT↗