Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fusion diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Interpolating individual line-of-sight neutron spectrometer measurements onto the “sky” at the National Ignition Facility (NIF)

Nuclear diagnostics provide measurements of inertial confinement fusion implosions used as metrics of performance for the shot. The interpretation of these measurements for shots with low mode asymmetries requires a way of combining the data to produce a “sky map” where the individual line-of-sight values are used to interpolate to other positions in the sky. These interpolations can provide information regarding the orientation of the low mode asymmetries. We describe the interpolation method, associated uncertainties, and correlations between different metrics, e.g., Tion, down scatter ratio, and hot-spot velocity direction. This work is also related to recently reported studies [H. G. Rinderknecht et al., Phys. Rev. Lett. 124, 145002 (2020) and K. M. Woo et al., Phys. Plasmas 27, 062702 (2020)] of low mode asymmetries. We report an analysis that makes use of a newly commissioned line of sight, a scheme for incorporating multiple neutron spectrum measurement types, and recent work on the sources of implosion asymmetry to provide a more complete picture of implosion performance.

Hartouni, E. P. (ORCID:0000000198694351)↗

In situ calibration of charged particle spectrometers on the OMEGA Laser Facility using 241 Am and 226 Ra sources

Charged particle spectrometry is a critical diagnostic to study inertial-confinement-fusion plasmas and high energy density plasmas. The OMEGA Laser Facility has two fixed magnetic charged particle spectrometers (CPSs) to measure MeV-ions. In situ calibration of these spectrometers was carried out using 241 Am and 226 Ra alpha emitters. The alpha emission spectrum from the sources was measured independently using surface-barrier detectors (SBDs). The energy dispersion and broadening of the CPS systems were determined by comparing the CPS measured alpha spectrum to that of the SBD. The calibration method significantly constrains the energy dispersion, which was previously obtained through the measurement of charged particle fusion products. Overall, a small shift of 100 keV was observed between previous and the calibration done in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion cyclotron heating at high plasma density in Proto-MPEX

The physics of ion cyclotron heating (ICH) relevant to the steady-state linear machine MPEX (Material Plasma Exposure eXperiment) has been explored in its predecessor, short-pulse device: Proto-MPEX. MPEX will utilize fundamental ICH to increase heat flux at the target and produce ion temperatures and velocity distributions with improved fidelity to those found in a tokamak divertor region, in comparison to those produced by substrate biasing. In the experiments on Proto-MPEX described here, bulk ion temperatures up to ~15 eV have been achieved with 20 kW net ICH power at 6.5 MHz, using ICH heating of a deuterium plasma produced by a helicon plasma source. The heat flux at the target has been observed to increase throughout the plasma cross section, including in the core region. Core $T_i$ and target heat flux are observed to scale linearly with injected ICH power. Further, measurements of plasma loading and target heat flux as a function of the magnetic field strength at the antenna, together with modeling of the wave propagation from the antenna to the ion cyclotron resonance using the ANTENA and COMSOL codes with a warm plasma dielectric tensor, indicate that power is coupled to the core plasma via fast wave excitation of a kinetic Alfvén wave.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The ICF National Diagnostic Plan (NDP) September 2020

This documents the National Diagnostic Plan as of September 2020. The major changes in this version compared to the NDP document issued in 2019 are the new schedules and the text for the national transformative diagnostics - section III, and a new transformational diagnostic is being added hCMOS. The many local diagnostics for our three Inertial Confinement Fusion (ICF) facilities; NIF, Z and OMEGA are updated and captured in section V.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The National Diagnostic Plan(NDP)for HED Science: September 2021

This report documents the National Diagnostic Plan as of September 2021. The major changes in this version compared to the NDP document issued in 2020 are the new schedules and the text for the national transformative diagnostics–section III. The many local diagnostics for our three Inertial Confinement Fusion (ICF) facilities, NIF, Z, and OMEGA, are updated and captured in section V.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fluctuations and Self-Organization in Plasma Boundary Layers (Final Report)

Final technical report on an experimental study of the boundary of an ionized gas (plasma) where it interacts with solid surfaces. The plasma self-organizes into a sheath which experiences plasma flow and is naturally unstable to various fluctuations which can be observed with advanced laser-spectroscopy techniques.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The National Diagnostic Plan (NDP) for HED Science September 2022

This documents the National Diagnostic Plan as of September 2022. The major changes in this version compared to the NDP document issued in 2021 are the new schedules and the text for the national transformative diagnostics - section III. The many local diagnostics for our three Inertial Confinement Fusion (ICF) facilities; NIF, Z and OMEGA are updated and captured in section V.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The National Diagnostic Plan (NDP) for HED Science September 2023

This documents the National Diagnostic Plan as of September 2023. The major changes in this version compared to the NDP document issued in 2021 are the new schedules and the text for the national transformative diagnostics - section III. The many local diagnostics for our three Inertial Confinement Fusion (ICF) facilities; NIF, Z and OMEGA are updated and captured in section V.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A glimpse of stars the size of dust particles

The Nuclear Imaging System (NIS) is an important diagnostic tool used to study nuclear fusion implosions at a research facility in California. There a capsule the size of a flea is compressed until it reaches the size of a speck of dust. As the capsule collapses on itself and ignites under extreme temperature and pressure, NIS detects particles emitted from that process at a scale that would correspond to watching a 32-inch TV screen from 100 miles away. My work involves taking snapshots of one of the most minuscule, fleeting and amazing experiments on Earth in order to ensure the safety and reliability of the US nuclear stockpile and get closer to developing a new form of clean energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing a Novel Neutron Time-of-Flight Diagnostic Platform for Z: Ultrafast Pixel Array Camera System

This report describes a Late-Start LDRD project on a compact neutron time-of-flight (nTOF) diagnostic, based on the Ultra-Fast Pixel Array Camera (UPAC) platform. By leveraging advancements in microelectronics, the UPAC nTOF is designed to address existing challenges of current nTOFs at the Z-machine that rely on large scintillators and photomultiplier tubes using bulky, discrete digitizing units hindering scalability with signal routing presenting an additional challenge. The report describes the UPAC diagnostic platform, outlines the calibration of the diagnostic and the latest results of fielding the UPAC as a ride-a-long diagnostic on the Magnetized liner inertial fusion (MagLIF) campaigns at the Z-machine supported by the Late-Start LDRD, and finally discusses conclusions and proposed future work.

42 ENGINEERING↗

LLNL FESP Theory Highlights: November 2024

This talk presented a refined understanding of plasma-facing thermionic emitter cathodes by examining the limitations of the conventional space charge-limited model, which overlooks ion trapping dynamics within the virtual cathode. While conventional theory distinguishes between temperature-limited and space charge-limited regimes based on electron current constraints, recent findings reveal that trapped ions can form a quasi-neutral "second plasma," expanding upstream and interacting with the primary plasma. These effects are amplified in non-planar geometries, such as cylindrical or spherical sheaths, where trapped ions create a positive feedback loop with the upstream plasma. To address these phenomena, a new "Aid-and-Compete" model was developed, offering insights into current enhancement and sheath mode transitions relevant for plasma devices, including emissive cathodes in electric propulsion, fusion applications, thin film deposition systems, and plasma diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The National Diagnostic Plan (NDP) for HED Science September 2025

This documents the National Diagnostic Plan as of September 2025. The major changes in this version compared to the NDP document issued in 2024 are the new schedules and the text for the national transformative diagnostics - section III. The many local diagnostics for our three Inertial Confinement Fusion (ICF) facilities; NIF, Z and OMEGA are also updated and captured in section V.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Applicability of alkali beam emission spectroscopy on NSTX-U

Understanding fast pedestal dynamics and turbulent transport in the edge and scrape-off layer (SOL) plasma of spherical tokamaks is crucial for the design and operation of future fusion reactors. The alkali beam emission spectroscopy diagnostic technique offers a means to measure the absolute electron density radial profile and fluctuation amplitude in these regions. Here, in this study, we demonstrate that injecting a sodium neutral beam radially into the plasma and analyzing the light emission from its 3p–3s atomic transition using near-orthogonal viewing angles allows for accurate measurement of the electron density profile and fluctuations in the National Spherical Torus Experiment (NSTX) Upgrade spherical tokamak. Our findings indicate a peak signal-to-noise ratio of 118 in the pedestal and 12 in the SOL under typical NSTX plasma conditions. The spatial resolution for the electron density profile is estimated to be between 2 and 8 mm, while for fluctuation measurements, it ranges from 12 to 15 mm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗