Design of an external-fueled thermionic diode for in-pile testing.

Description of an external-fueled thermionic diode suitable for in-pile testing in a research reactor. The active electrode area is 94 sq cm. The 10-in. long, 1.5-in.-OD emitter body is tungsten 2% thoria. The fuel is contained in six 0.4-in.-diam holes equally spaced about the 0.5-in. central emitter hole. The collector is niobium-1% zirconium. The expected diode performance is 6 W/sq cm at 2000 K. In addition to following the constraints imposed by the in-pile testing and the electrically heated performance mapping prior to insertion in-pile, the diode will have end configurations prototypical of those anticipated for a flow-through, NaK-cooled, external-fuel thermionic reactor.

Ernst, D. M.↗

Development of a full-length external-fuel thermionic converter for in-pile testing.

Description of an external-fuel thermionic converter which utilizes a thoriated-tungsten fuel-emitter body. Performance in out-of-pile tests was comparable to that of an arc-cast tungsten emitter body, with 400-eW output power (about 5 W/sq cm) at 10.8% efficiency. Maximum fuel clad temperature averaged from 1650 to 1700 C during the 300-hour test. This converter has been processed for in-pile testing. The various processing steps, including the installation of six emitter thermocouples, encapsulation in the secondary container, and joining to the fission-gas collection system, are described in detail. In addition to the converter assembly, a doubly contained fission gas collection assembly with radiation-hardened differential pressure transducers was fabricated. The experiment support plate required for the in-pile test, containing electrically insulated instrumentation feedthroughs and coolant line feedthroughs to the vacuum test chamber, was also fabricated.

Schock, A.↗

Flight test summary of modified fuel systems

Two different aircraft designs, each with two modified fuel control systems, were evaluated. Each aircraft was evaluated in a given series of defined ground and flight conditions while quantitative and qualitative observations were made. During this program, some ten flights were completed, and a total of about 13 hours of engine run time was accumulated by the two airplanes. The results of these evaluations with emphasis on the operational and safety aspects were analyzed. Ground tests of the engine alone were not able to predict acceptable limiting lean mixture settings for the flight envelopes of the Cessna Models 150 and T337.

Barrett, B. G.↗

Application of Simulated Reactivity Feedback in Nonnuclear Testing of a Direct-Drive Gas-Cooled Reactor

Nonnuclear testing can be a valuable tool in the development of an in-space nuclear power or propulsion system. In a nonnuclear test facility, electric heaters are used to simulate heat from nuclear fuel. Standard testing allows one to fully assess thermal, heat transfer, and stress related attributes of a given system but fails to demonstrate the dynamic response that would be present in an integrated, fueled reactor system. The integration of thermal hydraulic hardware tests with simulated neutronic response provides a bridge between electrically heated testing and full nuclear testing. By implementing a neutronic response model to simulate the dynamic response that would be expected in a fueled reactor system, one can better understand system integration issues, characterize integrated system response times and response and response characteristics, and assess potential design improvements with a relatively small fiscal investment. Initial system dynamic response testing was demonstrated on the integrated SAFE 100a heat pipe cooled, electrically heated reactor and heat exchanger hardware. This Technical Memorandum discusses the status of the planned dynamic test methodology for implementation in the direct-drive gas-cooled reactor testing and assesses the additional instrumentation needed to implement high-fidelity dynamic testing.

Bragg-Sitton, S. M.↗

Microgravity Flame Spread in Exploration Atmospheres: Pressure, Oxygen, and Velocity Effects on Opposed and Concurrent Flame Spread

Microgravity tests of flammability and flame spread were performed in a low-speed flow tunnel to simulate spacecraft ventilation flows. Three thin fuels were tested for flammability (Ultem 1000 (General Electric Company), 10 mil film, Nomex (Dupont) HT90-40, and Mylar G (Dupont) and one fuel for flame spread testing (Kimwipes (Kimberly-Clark Worldwide, Inc.). The 1g Upward Limiting Oxygen Index (ULOI) and 1g Maximum Oxygen Concentration (MOC) are found to be greater than those in 0g, by up to 4% oxygen mole fraction, meaning that the fuels burned in 0g at lower oxygen concentrations than they did using the NASA Standard 6001 Test 1 protocol. Flame spread tests with Kimwipes were used to develop correlations that capture the effects of flow velocity, oxygen concentration, and pressure on flame spread rate. These correlations were used to determine that over virtually the entire range of spacecraft atmospheres and flow conditions, the opposed spread is faster, especially for normoxic atmospheres. The correlations were also compared with 1g MOC for various materials as a function of pressure and oxygen. The lines of constant opposed flow agreed best with the 1g MOC trends, which indicates that Test 1 limits are essentially dictated by the critical heat flux for ignition. Further evaluation of these and other materials is continuing to better understand the 0g flammability of materials and its effect on the oxygen margin of safety.

Olson, Sandra L.↗

Dynamic Response Testing in an Electrically Heated Reactor Test Facility

Non-nuclear testing can be a valuable tool in development of a space nuclear power or propulsion system. In a non-nuclear test bed, electric heaters are used to simulate the heat from nuclear fuel. Standard testing allows one to fully assess thermal, heat transfer, and stress related attributes of a given system, but fails to demonstrate the dynamic response that would be present in an integrated, fueled reactor system. The integration of thermal hydraulic hardware tests with simulated neutronic response provides a bridge between electrically heated testing and full nuclear testing. By implementing a neutronic response model to simulate the dynamic response that would be expected in a fueled reactor system, one can better understand system integration issues, characterize integrated system response times and response characteristics, and assess potential design improvements at a relatively small fiscal investment. Initial system dynamic response testing was demonstrated on the integrated SAFE-100a heat pipe cooled, electrically heated reactor and heat exchanger hardware, utilizing a one-group solution to the point kinetics equations to simulate the expected neutronic response of the system (Bragg-Sitton, 2005). The current paper applies the same testing methodology to a direct drive gas cooled reactor system, demonstrating the applicability of the testing methodology to any reactor type and demonstrating the variation in system response characteristics in different reactor concepts. In each testing application, core power transients were controlled by a point kinetics model with reactivity feedback based on core average temperature; the neutron generation time and the temperature feedback coefficient are provided as model inputs. Although both system designs utilize a fast spectrum reactor, the method of cooling the reactor differs significantly, leading to a variable system response that can be demonstrated and assessed in a non-nuclear test facility.

Bragg-Sitton, Shannon M.↗

Testing of uranium nitride fuel in T-111 cladding at 1200 K cladding temperature

Two groups of six fuel pins each were assembled, encapsulated, and irradiated in the Plum Brook Reactor. The fuel pins employed uranium mononitride (UN) in a tantalum alloy clad. The first group of fuel pins was irradiated for 1500 hours to a maximum burnup of 0.7-atom-percent uranium. The second group of fuel pins was irradiated for about 3000 hours to a maximum burnup of 1.0-atom-percent uranium. The average clad surface temperature during irradiation of both groups of fuel pins was approximately 1200 K. The postirradiation examination revealed the following: no clad failures or fuel swelling occurred; less than 1 percent of the fission gases escaped from the fuel; and the clad of the first group of fuel pins experienced clad embrittlement whereas the second group, which had modified assembly and fabrication procedures to minimize contamination, had a ductile clad after irradiation.

Rohal, R. G.↗

Preliminary Tests on the Vaporization of Fuel Sprays

High-speed motion pictures were taken of fuel sprays injected into the combustion chamber of the N.A.C.A. combustion apparatus. Three fuels, ethyl alcohol, gasoline, and fuel oil, which differed considerably in volatility were tested. By maintaining the engine temperature below that required for ignition the spray could be studied from soon after the start of injection until 130 crank degrees later. The results show that the sprays vaporize appreciably so that it is possible for the ignition in high speed compression-ignition engines to take place from the vapor phase.

Rothrock, A M↗

Atomization of liquid fuels. Part III

This report provides a critical discussion of the results of the experiments conducted in the previous NACA-TM's 329 and 330. The main object of this investigation was to determine the size of the drops in mechanical atomization.

FUELS - TESTS↗

Flight Test of the Engine Fuel Schedules of the X-43A Hyper-X Research Vehicles

The Hyper-X program flew two X-43A Hyper-X Research Vehicles (HXRVs) in 2004, referred to as Ship 2 and Ship 3. The scramjet engine of the X-43A research vehicle was autonomously controlled in flight to track a predetermined fueling schedule. Ship 2 flew at approximately Mach 7 and Ship 3 flew at approximately Mach 10.

Jones, Thomas↗

Fuel Sensitivity of Gas Emissions, Lean Blowout and Combustion Dynamics for a 9-Point LDI Combustor

Fuel sensitivity of gaseous emissions, approach to lean blowout and combustion dynamics are evaluated in this study. Experiments were conducted at the NASA Glenn Research Center's CE-5 flame tube test facility with a 9-point Swirl-Venturi Lean Direct Injection (SV-LDI) combustor. A reference jet fuel (A2) and two test fuels (C1 and C3) from were provided by the National Jet Fuels Combustion Program (NJFCP). C1 is essentially a 2-component iso-paraffin test fuel with a low cetane number of 17, and C3 is a high viscosity test fuel. Approach to lean blowout was monitored in terms of the rapid increase in CO emissions index as equivalence ratio decreased, but testing did not proceed all the way to lean blowout (LBO). Burning C1 was found to produce lower NOx emissions, but C1 flame temperatures were about 25 K higher relative to A2 at near LBO points (where CO emissions increased very rapidly). The NOx emissions of C3 were similar to A2. At low power conditions where fuel injector performance is not optimized for this 9-point LDI combustor, C3 had higher CO emissions than A2 and C1, likely due to C3's higher viscosity relative to A2 and C1. No discernable difference in combustion dynamics was observed between the three fuels tested in the 9-point LDI combustor. While a systematic ignition test campaign was not conducted, it was observed that C1 required a higher equivalence ratio and inlet air temperature for test rig ignition compared to A2 and C3.