Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fourier Transform”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Fourier transform spectrometer observations of solar carbon monoxide. II - Simultaneous cospatial measurements of the fundamental and first-overtone bands, and Ca II K, in quiet and active regions

Fourier transform spectrometry has yielded simultaneous cospatial measurements of important diagnostics of thermal structure in the high solar photosphere and low chromosphere. It is noted that the anomalous behavior of the fundamental bands of CO in quiet areas near the limb is accentuated in an active region plage observed close to the limb. The difference between the core temperatures of the CO fundamental bands in a plage and a nearby quiet region at the limb is larger than the corresponding brightness temperature differences in the inner wings of the Ca II line measured in a quiet region and several plages closer to the disk center. Numerical simulations indicate that the disparate behavior of the CO bands with respect to Ca II K cannot be reconciled with existing single component thermal structure models; a two-component atmosphere is required.

Ayres, T. R.↗

50 Years of Spaceflight with Fourier Transform Spectrometers (FTS) Built at NASA GSFC

Over the past 50 years, NASA Goddard Space Flight Center (GSFC) has been developing, building, testing and flying a series of Fourier Transform Spectrometers (FTS). This began with the IRIS instruments on the Earth-orbiting Nimbus satellites and progressed to more sophisticated designs optimized for interplanetary spacecraft sent to Mars and later to the outer solar system. Adaptions have been made over time, including progressively higher spectral resolution, sensitivity, numbers of detectors and complexity. Instrument operating temperatures have decreased to enable remote sensing of the cold giant planet systems. In this paper we describe the historical evolution of this instrument line, comparing and contrasting different aspects such as optical design and materials, detector types and data handling. We conclude by looking towards the future. At present the CIRS-Lite prototype is being tested at NASA GSFC for potential use on a future mission to the ice giants, Uranus and Neptune. Surpassing the previous performance of the Voyager IRIS instruments remains challenging, and new technologies that could enable these measurements are discussed.

Nixon, Conor A.↗

A numerical method based on the Fourier-Fourier transform approach for modeling 1-D electron plasma evolution

A numerical method is presented for studying one-dimensional electron plasma evolution under typical interplanetary conditions. The method applies the Fourier-Fourier transform approach to a plasma model that is a generalization of the electrostatic Vlasov-Poisson system of equations. Conservation laws that are modified to include the plasma model generalization and also the boundary effects of nonperiodic solutions are given. A new conservation law for entropy in the transformed space is then introduced. These conservation laws are used to verify the numerical solutions. A discretization error analysis is presented. Two numerical instabilities and the methods used for their suppression are treated. It is shown that in interplanetary plasma conditions, the bump-on-tail instability produces significant excitation of plasma oscillations at the Bohm-Gross frequency and its second harmonic. An explanation of the second harmonic excitation is given in terms of wave-wave coupling during the growth phase of the instability.

Klimas, A. J.↗

Discrete Fourier Transform in a Complex Vector Space

An image-based phase retrieval technique has been developed that can be used on board a space based iterative transformation system. Image-based wavefront sensing is computationally demanding due to the floating-point nature of the process. The discrete Fourier transform (DFT) calculation is presented in "diagonal" form. By diagonal we mean that a transformation of basis is introduced by an application of the similarity transform of linear algebra. The current method exploits the diagonal structure of the DFT in a special way, particularly when parts of the calculation do not have to be repeated at each iteration to converge to an acceptable solution in order to focus an image.

Dean, Bruce H.↗

An automatic frequency control loop using overlapping DFTs (Discrete Fourier Transforms)

An automatic frequency control (AFC) loop is introduced and analyzed in detail. The new scheme is a generalization of the well known Cross Product AFC loop that uses running overlapping discrete Fourier transforms (DFTs) to create a discriminator curve. Linear analysis is included and supported with computer simulations. The algorithm is tested in a low carrier to noise ratio (CNR) dynamic environment, and the probability of loss of lock is estimated via computer simulations. The algorithm discussed is a suboptimum tracking scheme with a larger frequency error variance compared to an optimum strategy, but offers simplicity of implementation and a very low operating threshold CNR. This technique can be applied during the carrier acquisition and re-acquisition process in the Advanced Receiver.

Aguirre, S.↗

Direct measurement of storage and loss behavior in AFM force–distance experiments using the modified Fourier transformation

Force–distance curve experiments are commonly performed in atomic force microscopy (AFM) to obtain the viscoelastic characteristics of materials, such as the storage and loss moduli or compliances. The classic methods used to obtain these characteristics consist of fitting a viscoelastic material model to the experimentally obtained AFM data. Here, we demonstrate a new method that utilizes the modified discrete Fourier transform to approximate the storage and loss behavior of a material directly from the data, without the need for a fit. Additionally, one may still fit a model to the resulting storage and loss behavior if a parameterized description of the material is desired. In contrast to fitting the data to a model chosen a priori, departing from a model-free description of the material's frequency behavior guides the selection of the model, such that the user may choose the one that is most appropriate for the particular material under study. To this end, we also include modified Fourier domain descriptions of commonly used viscoelastic models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Planetary infrared astronomy using a cryogenic postdisperser on Fourier transform spectrometers

High resolution infrared spectra of planets from ground-based observatories were analyzed and instrumentation to improve sensitivity was developed. A cryogenic postdisperser (a narrow bandpass spectral filter) for use with Fourier transform spectrometers (FTS's) at facility observatories was constructed. This instrument has improved the sensitivity of FTS observations at 8 to 20 microns by about an order of magnitude. Spectra of Jupiter, Saturn and Comet Halley were obtained using the postdisperser with FTS facilities at the Kitt Peak 4-meter and McMath telescopes. Spectral resolution as high as 0.01/cm was achieved.

Jennings, D. E.↗

Transfer Function Identification Using Orthogonal Fourier Transform Modeling Functions

A method for transfer function identification, including both model structure determination and parameter estimation, was developed and demonstrated. The approach uses orthogonal modeling functions generated from frequency domain data obtained by Fourier transformation of time series data. The method was applied to simulation data to identify continuous-time transfer function models and unsteady aerodynamic models. Model fit error, estimated model parameters, and the associated uncertainties were used to show the effectiveness of the method for identifying accurate transfer function models from noisy data.

Morelli, Eugene A.↗

Fourier transform methods in local gravity modeling

New algorithms were derived for computing terrain corrections, all components of the attraction of the topography at the topographic surface and the gradients of these attractions. These algoriithms utilize fast Fourier transforms, but, in contrast to methods currently in use, all divergences of the integrals are removed during the analysis. Sequential methods employing a smooth intermediate reference surface were developed to avoid the very large transforms necessary when making computations at high resolution over a wide area. A new method for the numerical solution of Molodensky's problem was developed to mitigate the convergence difficulties that occur at short wavelengths with methods based on a Taylor series expansion. A trial field on a level surface is continued analytically to the topographic surface, and compared with that predicted from gravity observations. The difference is used to compute a correction to the trial field and the process iterated. Special techniques are employed to speed convergence and prevent oscillations. Three different spectral methods for fitting a point-mass set to a gravity field given on a regular grid at constant elevation are described. Two of the methods differ in the way that the spectrum of the point-mass set, which extends to infinite wave number, is matched to that of the gravity field which is band-limited. The third method is essentially a space-domain technique in which Fourier methods are used to solve a set of simultaneous equations.

Harrison, J. C.↗

Analysis of the Advantages and Limitations of Stationary Imaging Fourier Transform Spectrometer

New developments in infrared sensor technology have potentially made possible a new space-based system which can measure far-infrared radiation at lower costs (mass, power and expense). The Stationary Imaging Fourier Transform Spectrometer (SIFTS) proposed by NASA Langley Research Center, makes use of new detector array technology. A mathematical model which simulates resolution and spectral range relationships has been developed for analyzing the utility of such a radically new approach to spectroscopy. Calculations with this forward model emulate the effects of a detector array on the ability to retrieve accurate spectral features. Initial computations indicate significant attenuation at high wavenumbers.

Beecken, Brian P.↗

Windowed Fourier transform and cross-correlation algorithms for molecular tagging velocimetry

In this study, simulated and experimental molecular tagging velocimetry (MTV) images have been analyzed with a technique commonly used to process grid images on surfaces, the windowed Fourier transform with local spectrum analysis (WFT-LSA). A systematic synthetic image study of the modulation transfer function (MTF) and error tendencies of the WFT-LSA was performed and compared with a PIV-style cross-correlation algorithm to see if advanced strategies such as iterative image deformation can improve analysis of gridded images with high noise levels. Testing of single-pass algorithms showed that in typical MTV images, the WFT-LSA yields significantly lower bias errors than cross-correlation (CC) at displacements greater than 1 pixel but slightly higher random error at all displacements and image conditions. Analysis of the MTF shows that CC provided better resolution of spatial fluctuations than the WFT-LSA in many combinations of grid size and interrogation window. Tests of image deformation algorithms showed that the gap in performance between CC and WFT-LSA is maintained even as both methods improve. Additionally, WFT-LSA and CC methods are applied to real MTV experiments in high-speed gas jet flows. A preliminary analysis of phosphorescence lifetime provided by acetone vapor excited at 266 nm is used for assessing the required gas speeds for making MTV application feasible. The application of WFT-LSA to real MTV images demonstrates the ability of the algorithm to handle further real-world effects that could not be considered in the synthetic image analysis, like reduced signal-to-noise ratio and non-uniform intensity of the tagging grid across the image introduced by the actual laser beam energy distribution. With experimental images, CC is more accurate with shear flows but less robust to high noise levels than WFT-LSA, as predicted by the synthetic image analysis.

42 ENGINEERING↗

Fourier transform spectroscopy of the nu3 band of the N3 radical

The nu3 transitions of N3 radicals produced by HN3-Cl reactions in a multipass cell (effective path length 100 m) are investigated experimentally using a Fourier-transform spectrometer with maximum resolution 0.004/cm. A total of 176 rotation-vibration lines are listed in a table and used, in combination with published data on 240 optical lines (Douglas and Jones, 1965), to determine the nu3 molecular constants. The lower-than-expected value of the nu3 fundamental frequency (1644.6784/cm) is attributed to the vibronic interaction discussed by Kawaguchi et al. (1981).

Brazier, C. R.↗

Polyphase-discrete Fourier transform spectrum analysis for the Search for Extraterrestrial Intelligence sky survey

The sensitivity of a matched filter-detection system to a finite-duration continuous wave (CW) tone is compared with the sensitivities of a windowed discrete Fourier transform (DFT) system and an ideal bandpass filter-bank system. These comparisons are made in the context of the NASA Search for Extraterrestrial Intelligence (SETI) microwave observing project (MOP) sky survey. A review of the theory of polyphase-DFT filter banks and its relationship to the well-known windowed-DFT process is presented. The polyphase-DFT system approximates the ideal bandpass filter bank by using as few as eight filter taps per polyphase branch. An improvement in sensitivity of approx. 3 dB over a windowed-DFT system can be obtained by using the polyphase-DFT approach. Sidelobe rejection of the polyphase-DFT system is vastly superior to the windowed-DFT system, thereby improving its performance in the presence of radio frequency interference (RFI).

Zimmerman, G. A.↗

Dynamic interferometer alignment and its utility in UV Fourier transform spectrometer systems

Dynamic alignment has been demonstrated as a practical approach to alignment maintenance for systems in the infrared region of the spectrum. On the basis of work done by OPTRA, this technique was introduced in commercial Fourier transform spectrometer systems in 1982 and in various forms is now available from a number of manufacturers. This paper reports on work by OPTRA to extend the basic technique to systems operating in the ultraviolet. In addition, this paper reports the preliminary results of the development of an alignment system using a laser diode in place of a gas laser normally found in dynamic alignment systems. A unique optical system and spatial heterodyne technique allows for achievement of a metrology system with characteristics that fully satisfy the requirements of an ultraviolet spectrometer system.

Dorval, Rick K.↗

A Novel Application of Fourier Transform Spectroscopy with HEMT Amplifiers at Microwave Frequencies

The goal was to develop cryogenic high-electron-mobility transistor (HEMT) based radiometers and use them to measure the anisotropy in the cosmic microwave background (CMB). In particular, a novel Fourier transform spectrometer (FTS) built entirely of waveguide components would be developed. A dual-polarization Ka-band HEMT radiometer and a similar Q-band radiometer were built. In a series of measurements spanning three years made from a ground-based site in Saskatoon, SK, the amplitude, frequency spectrum, and spatial frequency spectrum of the anisotropy were measured. A prototype Ka-band FTS was built and tested, and a simplified version is proposed for the MAP satellite mission. The 1/f characteristics of HEMT amplifiers were quantified using correlation techniques.

Wilkinson, David T.↗

Fourier Transform Ultraviolet Spectroscopy of the A Pi-2(3/2) Direct Current X Pi-2(3/2) Transition of BrO

The first spectra of the A (2)Pi(sub 3/2) from X (2)Pi(sub 3/2) electronic transition of BrO using Fourier transform ultraviolet spectroscopy are obtained. Broadband vibrational spectra acquired at 298 +/- 2 K and 228 +/- 5 K, as well as high-resolution rotational spectra of the A from X 7,0 and 12,0 vibrational bands are presented. Wavenumber positions for the spectra are obtained with high accuracy, and cross section assignments are made, incorporating the existing literature. With 35 cm(exp -1) (0.40 nm) resolution the absolute cross section at the peak of the 7,0 band is determined to be (1.58 +/- 0.12) x 10(exp -17) sq cm/molecule at 298 +/- 2 K and (1.97 +/- 0.15) x 10(exp -17) sq cm/molecule at 228 +/- 5 K. BrO dissociation energies are determined with a graphical Birge-Sponer technique, using Le Roy-Bernstein theory to place an upper limit on the extrapolation. From the ground-state dissociation energy, D(sub o)" = 231.0 +/- 1.7 kJ/mol, the heat of formation of BrO(g) is calculated, del(sub f)H(0 K) = 133.7 +/- 1.7 kJ/mol and del(sub f)H(298.15 K) = 126.2 +/- 1.7 kJ/mol. Cross sections for the high-resolution 7,0 and 12,0 rotational peaks are the first to be reported. The band structures are modeled, and improved band origins, rotational constants, centrifugal distortion constants, and linewidths are determined. In particular, J-dependent linewidths and lifetimes are observed for the both the 7,0 and 12,0 bands.

Wilmouth, David M.↗

Fourier Transform Spectrometer observations of solar carbon monoxide. I - The fundamental and first overtone bands in the quiet sun

Measurements of the 2200/cm fundamental and 4300/cm first overtone vibration-rotation band systems of solar carbon monoxide, were obtained with the Fourier Transform Spectrometer of the McMath telescope at Kitt Peak. The overtone measurements were taken at the east, north, and west heliocentric limbs, and at disk center. Observations of the strong fundamental bands were obtained at disk center and near the north limb. The low core brightness temperatures of the strongest fundamental carbon monoxide lines near the limb, reported previously by Noyes (1972) and Hall (1974), are confirmed. The possibility that thermal inhomogeneities might be responsible for the unusual behavior of the fundamental carbon dioxide lines have been examined. The somewhat discordant behavior of the fundamental lines at disk center compared with the north limb seems to favor a limb shadowing effect. The first overtone limb equivalent widths and the best-fit thermal and microvelocity models indicate a solar carbon abundance of 0.004 (on the scale with A sub H = 1) for an oxygen-to-carbon abundance ratio of 2.

Ayres, T. R.↗