Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Focusing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Design of an In-Slot Cooled Air-Core Flux-Focusing Permanent Magnet Synchronous Machine for Electric Aircraft Applications

High performance and reliable permanent magnet synchronous machines are potentially a key technology for enabling reduced emissions in future generations of sustainable aircraft. In this paper, a novel air-core flux focusing permanent magnet synchronous machine with carbon fiber shafting for aviation applications is presented. A low-fidelity analytical sizing tool is detailed for the motor topology. The sizing tool is used to explore design trades and create an example 100 kW flux-focusing motor for eVTOL applications. Higher fidelity finite element analysis was used to validate the predicted performance of the motor. The selected design is able to achieve roughly 97 percent efficiency and 6 kW/kg at a continuous operating power of 100 kW.

Jonathan Gutknecht↗

Validation Assessment of Loci/GGFS Gas Granular Flow Solver Predictions of Ejecta from Physics Focused Ground Test

NASA is preparing to return humans to the Moon to establish a sustained Lunar presence through the Artemis program. One area of concern for Lunar landers is the plume surface interaction (PSI) environment that poses several risks during a propulsive landing. Understanding the PSI environment caused by the landers is therefore important to designing successful landing missions. Towards this end, a two-phase, gas granular flow solver, Loci/GGFS, has been developed to predict the cratering and ejecta physics expected during a Lunar landing. The focus of this paper is on a validation assessment of Loci/GGFS predictions of ejecta with monodisperse glass beads (MGB). The validation assessment is performed with respect to the Physics Focused Ground Test 1 (PFGT1) conducted at NASA Marshall Space Flight Center (MSFC) in 2021. It is found that Loci/GGFS predicts similar initial cratering and ejecta features, with predictions of average velocities that are within 25% of experimental values.

Plume Surface Interaction↗

Validation Assessment of Loci/GGFS Gas Granular Flow Solver Predictions of Ejecta From Physics Focused Ground Test

NASA is preparing to return humans to the Moon to establish a sustained Lunar presence through the Artemis program. One area of concern for Lunar landers is the plume surface interaction (PSI) environment that poses several risks during a propulsive landing. Understanding the PSI environment caused by the landers is therefore important to designing successful landing missions. Towards this end, a two-phase, gas granular flow solver, Loci/GGFS, has been developed to predict the cratering and ejecta physics expected during a Lunar landing. The focus of this paper is on a validation assessment of Loci/GGFS predictions of ejecta with monodisperse glass beads (MGB). The validation assessment is performed with respect to the Physics Focused Ground Test 1 (PFGT1) conducted at NASA Marshall Space Flight Center (MSFC) in 2021. It is found that Loci/GGFS predicts similar initial cratering and ejecta features, with predictions of average velocities that are within 25% of experimental values.

Plume Surface Interaction↗

Recent Progress and Development of Self-Aligned Focusing Schlieren

A broad range of developments and applications of self-aligned focusing schlieren (SAFS)systems is presented. The replacement of the Ronchi ruling (RR) with a𝜇LCD was demonstrated with digital SAFS, which provides the ability to modulate the pattern and orientation without physical intervention. Additionally, replacement of the traditional RR with spectral-spatial filters was demonstrated to yield the ability to simultaneously image horizontal and vertical index of refraction gradients using two separate wavelengths. The application of the Scheimpflug principle to SAFS systems enables off-axis imaging and allowed for extended fields-of-view to be captured using a two-camera system. The addition of a plenoptic camera to a baseline SAFS system enables refocusing capabilities, which is demonstrated on two jets offset along the optical axis. Furthermore, application of an event-based camera to SAFS was shown to enable acquisition of sparse, spatio-temporal data. Beyond the listed developments, SAFS was applied to difficult and constraining facilities, such as the National Full-Scale Aerodynamics Complex(NFAC) 80- by 120-ft Wind Tunnel and the Thermal Acoustic Engines (TAE) rig at NASA Ames Research Center and NASA Glenn Research Center, respectively. Behavior of Ronchi rulings, Rochon prisms, and the use of quarter-wave plates versus quarter-wave films are evaluated to provide insight for future experimental design of SAFS-systems.

Self-Aligned Focusing Schlieren↗

Interaction of high intensity focused ultrasound with biological materials

This work is motivated by the possible medical application of focused ultrasound in minimally invasive treatment of a variety of disorders including those associated with soft tissue or disk element disruption in the vicinity of the spine causing impingement on the spinal cord.

focused ultrasound HIFU PZFlex↗

Analysis of the Amplitude Response of a Two-Point and a Two-Line/Multi-Point Focused Laser Differential Interferometer

Experiments were performed with two different focused laser differential interferometer (FLDI) instruments to assess the amplitude response of each instrument to a traveling shock-wave generated by a laser spark. The first FLDI instrument generated two measurement points, with each measurement point providing sensitivity to density fluctuations induced by the shockwave. By performing a cross-correlation between the signals obtained from each measurement point, the phase velocity of density fluctuations can be obtained. The second FLDI instrument generated two measurement lines that are oriented either parallel or orthogonal to the shockwave direction of travel with the resulting interference pattern sampled at multiple equally-spaced points along each line. As a result, this instrument provides density fluctuation measurement capability at multiple points simultaneously. When the measurement lines are oriented parallel to the shockwave direction of travel, the phase velocity, rate of change of the phase velocity, and acceleration of density fluctuations traveling along each line can be obtained by performing a cross-correlation between points along a single line. When the measurement lines are oriented orthogonal to the shockwave direction of travel, the spatially-varying phase velocity can be obtained by performing a cross-correlation between points at the same relative location on each measurement line. Computations of the shockwave generated by the laser spark are used to simulate the response of each instrument and are compared to the experimental results. High-speed Schlieren imaging has also been performed and is compared with the FLDI measurements and computational results.

Focused Laser Differential Interferometer↗

Attention Focusing and Anomaly Detection in Systems Monitoring

Any attempt to introduce automation into the monitoring of complex physical systems must start from a robust anomaly detection capability. This task is far from straightforward, for a single definition of what constitutes an anomaly is difficult to come by. In addition, to make the monitoring process efficient, and to avoid the potential for information overload on human operators, attention focusing must also be addressed. When an anomaly occurs, more often than not several sensors are affected, and the partially redundant information they provide can be confusing, particularly in a crisis situation where a response is needed quickly.

systems↗

Comparison of Single-Event Transients in an Epitaxial Silicon Diode Resulting from Heavy Ion-, Focused X-Ray-, and Pulsed Laser-Induced Charge Generation

Heavy ion, focused X-ray, pulsed laser single event transient experiments are performed on a silicon epitaxial diode. Collected charge, transient rise times, and transient fall times are calculated and compared between the different sources. The transient shape characteristics depend on the source (ion, X-ray, or laser), even when similar amounts of charge are generated. The observed differences are examined and explained in terms of basic charge collection mechanisms.

Heavy ions↗