Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fire Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Stockpile Stewardship: How We Ensure the Nuclear Deterrent Without Testing

In the 1990s, the U.S. nuclear weapons program shifted emphasis from developing new designs to dismantling thousands of existing weapons and maintaining a much smaller enduring stockpile. The United States ceased underground nuclear testing, and the Department of Energy created the Stockpile Stewardship Program to maintain the safety, security, and reliability of the U.S. nuclear deterrent without full-scale testing. This video gives a behind the scenes look at a set of unique capabilities at Lawrence Livermore that are indispensable to the Stockpile Stewardship Program: high performance computing, the Superblock category II nuclear facility, the JASPER a two stage gas gun, the High Explosive Applications Facility (HEAF), the National Ignition Facility (NIF), and the Site 300 contained firing facility.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Understanding Corrosion Mechanisms in Oxy-Fired Systems

Replacing air with oxygen in coal-fired boilers (i.e. oxy-firing) combined with flue gas recirculation is a leading strategy to concentrate CO{sub 2} and assist in carbon capture and sequestration. A significant area of concern is the fireside corrosion with oxy-firing due to the higher CO{sub 2} levels in the combustion gas and potentially higher SO{sub x} and H{sub 2}O levels. In order to investigate this complicated issue, laboratory experiments are being conducted with and without synthetic ash to assess the potential effect of oxy-firing on fireside corrosion rates. The initial results of this project focus on commercial and model Fe-base alloys at 600 C. Without ash, a 50%H{sub 2}O-50%(CO{sub 2}-0.15O{sub 2}) environment was the most aggressive condition, requiring higher Cr contents than 100% H{sub 2}O or Ar-50%CO{sub 2}. With the specimens covered in ash, several gas compositions were examined, including different levels of H{sub 2}O and SO{sub 2} to simulate various oxy-firing strategies. Results also are presented for several laser-clad coating compositions for protecting tubes. An additional task is examining the effect of environment on mechanical properties. Initial work studied Ni-base alloys in steam at 800 C and found little effect of steam on the creep rupture life of alloy 230 but a 35% decrease for alloy 740.

20 FOSSIL-FUELED POWER PLANTS↗

Wildfire-Power Grid Interactions: Feedback, Impacts, Monitoring, Modeling, and Mitigation Strategies

Wildfires are increasingly interacting with electric power systems through a two-way hazard chain: fires damage grid assets and trigger cascading outages, while grid faults can ignite new fires under hot, dry, and windy conditions. This review synthesizes the state of knowledge across five domains: (i) physical impacts of flames, heat, and smoke on lines, towers, insulators, and substations; (ii) power-infrastructure-initiated ignitions via conductor clash, high-impedance faults, and corona discharge; (iii) widespread blackouts and disproportionate societal impacts; (iv) multi-scale monitoring spanning laboratory tests, in-situ and grid-integrated sensors, and Earth observation; (v) coupled modeling that links fire behavior with grid operations; and (vi) technological and strategic mitigation pathways spanning prevention, response, and recovery. We integrate these domains into a novel 'feedback-aware' socio-technical framework. Through a longitudinal analysis (2005-2025) of global incidents, we identify that while vegetation contact remains the most frequent ignition source, aging infrastructure failure has emerged as a critical driver of catastrophic 'mega-fires'. We further identify persistent gaps, including limited interoperability of high-frequency grid and environmental data, scarce real-time data assimilation, and under-developed equity metrics for outage management. We conclude by outlining a research agenda to (1) deploy interoperable sensing architectures, (2) advance feedback-coupled fire-grid simulations, and (3) evaluate mitigation portfolios through techno-economic and fairness lenses. Recognizing wildfire-grid interactions as coupled socio-technical systems is essential for protecting infrastructure and communities and for ensuring reliable, sustainable electricity in a changing world.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wildland Fire Management Plan for Brookhaven National Laboratory

The DOE policy for managing wildland fires requires that all areas managed by DOE and/or Its various contractors which can sustain fire must have a FMP that details fire management guidelines for operational procedures associated with wildland fire, operational, and prescribed fires. FMPs provide guidance on fire preparedness, fire prevention, wildfire suppression, and the use of controlled ''prescribed'' fires and mechanical means to control the amount of available combustible material. Values reflected in the BNL Wildland FMP include protecting life and public safety; Lab properties, structures and improvements; cultural and historical sites; neighboring private and public properties; and endangered, threatened, and species of concern. Other values supported by the plan include the enhancement of fire-dependent ecosystems at BNL. The plan will be reviewed periodically to ensure fire program advances and will evolve with the missions of DOE and BNL.

54 ENVIRONMENTAL SCIENCES↗

Wildland Fire Management Plan for Brookhaven National Laboratory

This Wildland Fire Management Plan (FMP) for Brookhaven National Lab (BNL) updates the 2003 plan incorporating changes necessary to comply with DOE Order 450.1 and DOE P 450.4, Federal Wildland Fire Management Policy and Program Review; Wildland and Prescribed Fire Management Policy and implementation Procedures Reference Guide. This current plan incorporates changes since the original draft of the FMP that result from new policies on the national level. This update also removes references and dependence on the U.S. Fish & Wildlife Service and Department of the Interior, fully transitioning Wildland Fire Management responsibilities to BNL. The Department of Energy policy for managing wildland fires requires that all areas, managed by the DOE and/or its various contractors, that can sustain fire must have a FMP that details fire management guidelines for operational procedures associated with wild fire, operational, and prescribed fires. Fire management plans provide guidance on fire preparedness, fire prevention, wildfire suppression, and the use of controlled, 'prescribed' fires and mechanical means to control the amount of available combustible material. Values reflected in the BNL Wildland FMP include protecting life and public safety; Lab properties, structures and improvements; cultural and historical sites; neighboring private and public properties; and endangered, threatened, and species of concern. Other values supported by the plan include the enhancement of fire-dependent ecosystems at BNL. This FMP will be reviewed periodically to ensure the fire program advances and evolves with the missions of the DOE and BNL. This Fire Management Plan is presented in a format that coverers all aspects specified by DOE guidance documents which are based on the national template for fire management plans adopted under the National Fire Plan. The DOE is one of the signatory agencies on the National Fire Plan. This FMP is to be used and implemented for the entire BNL site including the Upton Reserve and has been reviewed by, The Nature Conservancy, New York State Department of Environmental Conservation Forest Rangers, and DOE, as well as appropriate BNL emergency services personnel. The BNL Fire Department is the lead on wildfire suppression. However, the BNL Natural Resource Manager will be assigned to all wildland fires as technical resource advisor.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modeling Heat Transfer and Pressurization of Polymeric Methylene Diisocyanate (PMDI) Polyurethane Foam in a Sealed Container

Polymer foam encapsulants provide mechanical, electrical, and thermal isolation in engineered systems. It can be advantageous to surround objects of interest, such as electronics, with foams in a hermetically sealed container to protect the electronics from hostile environments, such as a crash that produces a fire. However, in fire environments, gas pressure from thermal decomposition of foams can cause mechanical failure of the sealed system. In this work, a detailed study of thermally decomposing polymeric methylene diisocyanate (PMDI)-polyether-polyol based polyurethane foam in a sealed container is presented. Both experimental and computational work is discussed. Three models of increasing physics fidelity are presented: No Flow, Porous Media, and Porous Media with VLE. Each model us described in detail, compared to experiment, and uncertainty quantification is performed. While the Porous Media with VLE model matches has the best agreement with experiment, it also requires the most computational resources.

36 MATERIALS SCIENCE↗

Linking repeat lidar with Landsat products for large scale quantification of fire-induced permafrost thaw settlement in interior Alaska

The permafrost–fire–climate system has been a hotspot in research for decades under a warming climate scenario. Surface vegetation plays a dominant role in protecting permafrost from summer warmth, thus, any alteration of vegetation structure, particularly following severe wildfires, can cause dramatic top–down thaw. A challenge in understanding this is to quantify fire-induced thaw settlement at large scales (>1000 km 2 ). In this study, we explored the potential of using Landsat products for a large-scale estimation of fire-induced thaw settlement across a well-studied area representative of ice-rich lowland permafrost in interior Alaska. Six large fires have affected ~1250 km 2 of the area since 2000. We first identified the linkage of fires, burn severity, and land cover response, and then developed an object-based machine learning ensemble approach to estimate fire-induced thaw settlement by relating airborne repeat lidar data to Landsat products. The model delineated thaw settlement patterns across the six fire scars and explained ~65% of the variance in lidar-detected elevation change. Our results indicate a combined application of airborne repeat lidar and Landsat products is a valuable tool for large scale quantification of fire-induced thaw settlement.

54 ENVIRONMENTAL SCIENCES↗

Analysis of Potential Airborne Radionuclide Emissions During and After Fires Through Contaminated Soil Areas on the INL

Analysis of Potential Airborne Radionuclide Emissions During and After Fires Through Contaminated Soil Areas on the INL Wildfires on the INL have heightened concerns that such fires could burn through radiologically contaminated soil areas and could potentially pose a hazard to firefighters and the public. Exposure to windblown contaminated dust from fire-denuded landscapes is another concern. This report re-examines the potential for fire and dust releases from the six previously identified and posted (radiological) soil contamination areas (SCAs), as well as the one Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) site not posted as SCAs that were identified in the original 2001 revision of this report. Releases and their consequences, during and after fires are analyzed in detail for the SCAs and the one CERCLA site near INL facilities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Pipe Overpack Container Fire Testing: Phase I & II

The Pipe Overpack Container (POC) was developed at Rocky Flats to transport plutonium residues with higher levels of plutonium than standard transuranic (TRU) waste to the Waste Isolation Pilot Plant (WIPP) for disposal. In 1996 Sandia National Laboratories (SNL) conducted a series of tests to determine the degree of protection POCs provided during storage accident events. One of these tests exposed four of the POCs to a 30-minute engulfing pool fire, resulting in one of the 7A drum overpacks generating sufficient internal pressure to pop off its lid and expose the top of the pipe container (PC) to the fire environment. The initial contents of the POCs were inert materials, which would not generate large internal pressure within the PC if heated. However, POCs are now being used to store combustible TRU waste at Department of Energy (DOE) sites. At the request of DOE’s Office of Environmental Management (EM) and National Nuclear Security Administration (NNSA), starting in 2015 SNL conducted a new series of fire tests to examine whether PCs with combustibles would reach a temperature that would result in (1) decomposition of inner contents and (2) subsequent generation of sufficient gas to cause the PC to over-pressurize and release its inner content. Tests conducted during 2015 and 2016, and described herein, were done in two phases. The goal of the first phase was to see if the PC would reach high enough temperatures to decompose typical combustible materials inside the PC. The goal of the second test phase was to determine under what heating loads (i.e., incident heat fluxes) the 7A drum lid pops off from the POC drum. This report will describe the various tests conducted in phase I and II, present preliminary results from these tests, and discuss implications for the POCs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pipe Overpack Container Fire Testing: Phase II-A

The Pipe Overpack Container (POC) was developed at Rocky Flats to transport plutonium residues with higher levels of plutonium than standard transuranic (TRU) waste to the Waste Isolation Pilot Plant (WIPP) for disposal. In 1996 Sandia National Laboratories (SNL) conducted a series of tests to determine the degree of protection POCs provided during storage accident events. One of these tests exposed four of the POCs to a 30-minute engulfing pool fire, resulting in one of the 7A drum overpacks generating sufficient internal pressure to pop off its lid and expose the top of the pipe container (PC) to the fire environment. The initial contents of the POCs were inert materials, which would not generate large internal pressure within the PC if heated. However, POCs are now being used to store combustible Transuranic (TRU) waste at Department of Energy (DOE) sites. At the request of DOE's Office of Environmental Management (EM) and National Nuclear Security Administration (NNSA), SNL started conducting a new series of fire tests in 2015 to examine whether PCs with combustibles would reach a temperature that would result in (1) decomposition of inner contents and (2) subsequent generation of sufficient gas to cause the PC to overpressurize and release its inner content. In 2016, Phase II tests showed that POCs tested in a pool fire failed within 3 minutes of ignition with the POC lid ejecting. These POC lids were fitted with an all-metal (NUCFIL019DS) filter and revealed that this specific filter did not relieve sufficient pressure to prevent lid ejection. For the test phase discussed in this report, Phase II-A, the POCs are exposed to a 30-minute pool fire, with similar configurations to those tested in Phase II, except that the POC lids are fitted with a hybrid metal-polyethylene (UT9424S) filter instead. This report will: describe the various tests conducted in Phase II-A, present results from these tests, and discuss implications for the POCs based on the test results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pipe Overpack Container Fire Testing: Phase II-A

The Pipe Overpack Container (POC) was developed at Rocky Flats to transport plutonium residues with higher levels of plutonium than standard transuranic (TRU) waste to the Waste Isolation Pilot Plant (WIPP) for disposal. In 1996 Sandia National Laboratories (SNL) conducted a series of tests to determine the degree of protection POCs provided during storage accident events. One of these tests exposed four of the POCs to a 30-minute engulfing pool fire, resulting in one of the 7A drum overpacks generating sufficient internal pressure to pop off its lid and expose the top of the pipe container (PC) to the fire environment. The initial contents of the POCs were inert materials, which would not generate large internal pressure within the PC if heated. However, POCs are now being used to store combustible Transuranic (TRU) waste at Department of Energy (DOE) sites. At the request of DOE's Office of Environmental Management (EM) and National Nuclear Security Administration (NNSA), SNL started conducting a new series of fire tests in 2015 to examine whether PCs with combustibles would reach a temperature that would result in (1) decomposition of inner contents and (2) subsequent generation of sufficient gas to cause the PC to overpressurize and release its inner content. In 2016, Phase II tests showed that POCs tested in a pool fire failed within 3 minutes of ignition with the POC lid ejecting. These POC lids were fitted with an all-metal (NUCFIL019DS) filter and revealed that this specific filter did not relieve sufficient pressure to prevent lid ejection. For the test phase discussed in this report, Phase II-A, the POCs are exposed to a 30-minute pool fire, with similar configurations to those tested in Phase II, except that the POC lids are fitted with a hybrid metal-polyethylene (UT9424S) filter instead. This report will: describe the various tests conducted in Phase II-A, present results from these tests, and discuss implications for the POCs based on the test results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Protective Aluminide Coatings for NiCr Alloys in Combustion Environments

Laboratory exposures that simulated the oxidation-related attack in natural gas-fired reciprocating engines were conducted on Ni-Cr alloys with and without aluminide coatings. Exposure of uncoated Ni-Cr alloy specimens to humid air at 800 C resulted in a mass loss due to CrO{sub 2}(OH){sub 2} evaporation and internal oxidation. Both model and commercial aluminide coatings reduced the amount of attack. The reaction products and Al interdiffusion were evaluated.

03 NATURAL GAS↗

Pipe Overpack Container Fire Testing: Phase I II & III.

The Pipe Overpack Container (POC) was developed at Rocky Flats to transport plutonium residues with higher levels of plutonium than standard transuranic (TRU) waste to the Waste Isolation Pilot Plant (WIPP) for disposal. In 1996 Sandia National Laboratories (SNL) conducted a series of tests to determine the degree of protection POCs provided during storage accident events. One of these tests exposed four of the POCs to a 30-minute engulfing pool fire, resulting in one of the 7A drum overpacks generating sufficient internal pressure to pop off its lid and expose the top of the pipe container (PC) to the fire environment. The initial contents of the POCs were inert materials, which would not generate large internal pressure within the PC if heated. POCs are now being used to store combustible TRU waste at Department of Energy (DOE) sites. At the request of DOE’s Office of Environmental Management (EM) and National Nuclear Security Administration (NNSA), starting in 2015 SNL conducted a series of fire tests to examine whether PCs with combustibles would reach a temperature that would result in (1) decomposition of inner contents and (2) subsequent generation of sufficient gas to cause the PC to over-pressurize and release its inner content. Tests conducted during 2015 and 2016 were done in three phases. The goal of the first phase was to see if the PC would reach high enough temperatures to decompose typical combustible materials inside the PC. The goal of the second test phase was to determine under what heating loads (i.e., incident heat fluxes) the 7A drum lid pops off from the POC drum. The goal of the third phase was to see if surrogate aerosol gets released from the PC when the drum lid is off. This report will describe the various tests conducted in phase I, II, and III, present preliminary results from these tests, and discuss implications for the POCs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pipe Overpack Container Fire Testing: Phase II-B

The Pipe Overpack Container (POC) was developed at Rocky Flats to transport plutonium residues with higher levels of plutonium than standard transuranic (TRU) waste to the Waste Isolation Pilot Plant (WIPP) for disposal. In 1996 Sandia National Laboratories (SNL) conducted a series of tests to determine the degree of protection POCs provided during storage accident events. One of these tests exposed four of the POCs to a 30-minute engulfing pool fire. This test resulted in one of the POCs generating sufficient internal pressure to pop off its drum lid and expose the top of the pipe container (PC) to the fire environment. The initial contents of the POCs were inert materials that would not generate large internal pressure within the PC if heated. However, POCs are now being used to store combustible Transuranic (TRU) waste at Department of Energy (DOE) sites. At the request of DOE's Office of Environmental Management (EM) and National Nuclear Security Administration (NNSA), SNL started conducting a new series of fire tests in 2015 to examine whether PCs with combustibles would reach a temperature that could result in: (1) decomposition of inner contents and (2) subsequent generation of sufficient gas to cause the PC to over-pressurize and release its inner contents. In 2016, Phase II of the tests showed that POCs tested in a pool fire failed within 3 minutes of ignition with the POC lid ejecting. These POC lids were fitted with a NUCFIL-019DS filter and revealed that this specific filter did not relieve sufficient pressure to prevent lid ejection. In the Fall of 2017, Phase II-A was conducted to expose POCs to a 30-minute pool fire with similar configurations to those tested in Phase II, except that the POC lids were fitted with an UltraTech (UT) 9424S filter instead. That specific filter was chosen because of its design to help relieve internal pressure during the fire and thus prevent lid ejection. In Phase II-A, however, setups of two POCs stacked upon one another were never tested, which led to this phase of tests, Phase II-B. This report will describe the various tests conducted in Phase II-B, present results from these tests, and implications for the POCs based on the test results will be discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Novel Functionally Graded Thermal Barrier Coatings in Coal-Fired Power Plant Turbines

This project presents a detailed investigation of a novel functionally graded coating material, pyrochlore oxide, for thermal barrier coating (TBC) in gas turbines used in coal-fired power plants. Thermal barrier coatings are refractory materials deposited on gas turbine components, which provide thermal protection for metallic components at operating conditions. The ultimate goal of this research is to develop a manufacturing process to produce the novel low thermal conductivity and high thermal stability pyrochlore oxide based coatings with improved high-temperature durability. The current standard TBC, yttria stabilized zirconia (YSZ), has service temperatures limited to <1200°C, due to sintering and phase transition at higher temperatures. In contrast, pyrochlore oxide, e.g., lanthanum zirconate (La 2 Zr 2 O 7 , LZ), has demonstrated lower thermal conductivity and better thermal stability, which are crucial to high temperature applications, such as gas turbines used in coal-fired power plants. Indiana University – Purdue University Indianapolis (IUPUI) has collaborated with Praxair Surface Technologies (PST), and Changwon National University in South Korea to perform the proposed research. The research findings are critical to the extension of current TBCs to a broader range of high-temperature materials and applications. Several tasks were originally proposed and accomplished, with additional new opportunities identified during the course of the project. In this report, a description of the project tasks, the main findings and conclusions are given. A list of publications and presentations resulted from this research is listed in the Appendix at the end of the report.

20 FOSSIL-FUELED POWER PLANTS↗

Long-Term Persistence of Three Microbial Wildfire Biomarkers in Forest Soils

Long-term monitoring of microbial communities in the rhizosphere of post-fire forests is currently one of the key knowledge gaps. Knowing the time scale of the effects is indispensable to aiding post-fire recovery in vulnerable woodlands, including holm oak forests, that are subjected to a Mediterranean climate, as is the case with forests that are found in protected areas such as the Sierra Nevada National and Natural Park in southeastern Spain. We took rhizosphere soil samples from burned and unburned holm oak trees approximately 3, 6, and 9 years after the 2005 fire that devastated almost 3500 ha in southeastern Spain. We observed that the prokaryotic communities are recovering but have not yet reached the conditions observed in the unburned forest. A common denominator between this fire and other fires is the long-term persistence of three ecosystem recovery biomarkers—specifically, higher proportions of the genera Arthrobacter, Blastococcus, and Massilia in soil microbial communities after a forest fire. These pyrophilous microbes possess remarkable resilience against adverse conditions, exhibiting traits such as xerotolerance, nitrogen mineralization, degradation of aromatic compounds, and copiotrophy in favorable conditions. Furthermore, these biomarkers thrive in alkaline environments, which persist over the long term following forest fires. The relative abundance of these biomarkers showed a decreasing trend over time, but they were still far from the values of the control condition. In conclusion, a decade does not seem to be enough for the complete recovery of the prokaryotic communities in this Mediterranean ecosystem.

54 ENVIRONMENTAL SCIENCES↗

Response of the REWARD detection system to the presence of a Radiological Dispersal Device

In recent years an increased international concern has emerged about the radiological and nuclear (RN) threats associated with the illicit trafficking of nuclear and radioactive materials that could be potentially used for terrorist attacks. The objective of the REWARD (Real Time Wide Area Radiation Surveillance System) project, co-funded by the European Union 7. Framework Programme Security, consisted in building a mobile system for real time, wide area radiation surveillance, using a CdZnTe detector for gamma radiation and a neutron detector based on novel silicon technologies. The sensing unit includes a GPS system and a wireless communication interface to send the data remotely to a monitoring base station, where it will be analyzed in real time and correlated with historical data from the tag location, in order to generate an alarm when an abnormal situation is detected. Due to its portability and accuracy, the system will be extremely useful in many different scenarios such as nuclear terrorism, lost radioactive sources, radioactive contamination or nuclear accidents. This paper shortly introduces the REWARD detection system, depicts some terrorist threat scenarios involving radioactive sources and special nuclear materials and summarizes the simulation work undertaken during the past three years in the framework of the REWARD project. The main objective consisted in making predictions regarding the behavior of the REWARD system in the presence of a Radiological Dispersion Device (RDD), one of the reference scenarios foreseen for REWARD, using the Monte Carlo simulation program MCNP6. The reference scenario is characterized in detail, from the i) radiological protection, ii) radiation detection requirements and iii) communications points of view. Experimental tests were performed at the Fire Brigades Facilities in Rome and at the Naples Fire Brigades, and the results, which validate the simulation work, are presented and analyzed. The response of the REWARD detection system to the presence of an RDD is predicted and discussed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗