Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fermi acceleration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

CAPTAN+X Data Converter Integration

Fermi National Accelerator Laboratory's CAPTAN (Compact And Programmable daTa Acquisition Node) series provides a flexible hardware platform for data acquisition across a range of experiments and facilities. The latest iteration, CAPTAN+X, is built around a Kintex-7 FPGA supporting four FPGA Mezzanine Card (FMC) connections. As part of a broader laboratory effort to bring facility systems under a Model-Based Systems Engineering (MBSE) framework, CAPTAN+X is one of several systems slated to be incorporated into this modeling environment in the near term. A necessary step toward that goal is incorporating the platform's core functionality, which centers on integration with the LXD31K4 FMC, a data converter module combining dual AD9652 analog-to-digital converters and dual AD9142A digital-to-analog converters. Achieving compatibility required resolving pin-mapping conflicts between the LXD31K4's High Pin Count connector and the CAPTAN+X's available pin types, adapting a Board Support Project originally written for an UltraScale-class evaluation board to the Kintex-7 architecture, replacing incompatible primitives, restructuring clock distribution, and manually configuring chip initialization in place of an unsupported soft-processor-based approach. Functional verification of the ADC and DAC channels, followed by closed-loop testing combining both converters with real-time filtering, confirmed correct operation of the integrated system. These results establish a working hardware and firmware baseline for the CAPTAN+X platform, positioning it for future inclusion in the laboratory's growing MBSE modeling effort.

Espinoza, David [Illinois U., Urbana (main)]↗

Proton transparency and neutrino physics: New methods and modeling

Extracting accurate results from neutrino oscillation and cross section experiments requires accurate simulation of the neutrino-nucleus interaction. The rescattering of outgoing hadrons (final state interactions) by the rest of the nucleus is an important component of these interactions. We present a new measurement of proton transparency (defined as the fraction of outgoing protons that emerge without significant rescattering) using electron-nucleus scattering data recorded by the CLAS detector at Jefferson Laboratory on helium, carbon, and iron targets. This analysis uses a new data-driven method to extract the transparency. It defines transparency as the ratio of electron-scattering events with a detected proton to quasi-elastic electron-scattering events where a proton should have been knocked out. Our results are consistent with previous measurements that determined the transparency from the ratio of measured events to theoretically predicted events. We find that the GENIE event generator, which is widely used by oscillation experiments to simulate neutrino-nucleus interactions, needs to better describe both the nuclear ground state and proton rescattering in order to reproduce our measured transparency ratios, especially at lower proton momenta.

direct reactions↗

Cryogenic optical beam steering for superconducting device calibration

We have developed a calibration system based on a micro-electromechanical systems (MEMS) mirror that is capable of delivering an optical beam over a wavelength range of 180 -- 2000 nm (0.62 -- 6.89 eV) in a sub-Kelvin environment. This portable, integrated system can steer the beam over a $\sim$3 cm $\times$ 3 cm area on the surface of any sensor with a precision of $\sim$100 $μ$m, enabling characterization of device response as a function of position. This fills a critical need in the landscape of calibration tools for sub-Kelvin devices, including those used for dark matter detection and quantum computing. These communities have a shared goal of understanding the impact of ionizing radiation on device performance, which can be pursued with our system. This paper describes the design of the first-generation calibration system and the results from successfully testing its performance at room temperature and 20 mK.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

FermiBadgerPlugins

Plugins for using Badger at the Fermilab main accelerator complex

St. John, JasonM. [Fermi National Accelerator Labo↗

Measurements of Pion and Muon Nuclear Capture at Rest on Argon in the LArIAT Experiment

We report the measurement of the final-state products of negative pion and muon nuclear capture at rest on argon by the LArIAT experiment at the Fermilab Test Beam Facility. We measure a population of isolated MeV-scale energy depositions, or blips, in 296 LArIAT events containing tracks from stopping low-momentum pions and muons. The average numbers of visible blips are measured to be 0.74 ± 0.19 and 1.86 ± 0.17 near muon and pion track endpoints, respectively. The 3.6⁢𝜎 statistically significant difference in blip content between muons and pions provides the first demonstration of a new method of pion-muon discrimination in neutrino liquid argon time projection chamber experiments. LArIAT Monte Carlo simulations predict substantially higher average blip counts for negative muon (1.22 ± 0.08) and pion (2.34 ± 0.09) nuclear captures. We attribute this difference to geant4’s inaccurate simulation of the nuclear capture process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Axionlike Particle Results from a Broadband Search for Wavelike Dark Matter in the 44 to 52 μ ⁢eV Range with a Coaxial Dish Antenna

We present the results from the first axionlike particle search conducted using a dish antenna. The experiment was conducted at room temperature and sensitive to axionlike particles in the 44–52 μ ⁢eV range (10.7–12.5 GHz). The novel dish antenna geometry was proposed by the BREAD Collaboration and previously used to conduct a dark photon search in the same mass range. To allow for axionlike particle sensitivity, the BREAD dish antenna was placed in a 3.9 T solenoid magnet at Argonne National Laboratory. In the presence of a magnetic field, axionlike dark matter converts to photons at the conductive surface of the reflector. The signal is focused onto a custom coaxial horn antenna and read out with a low-noise radio-frequency receiver. No evidence of axionlike dark matter was observed in this mass range and we place the most stringent laboratory constraints on the axion-photon coupling strength, 𝑔 𝑎⁢𝛾⁢𝛾 , in this mass range at 90% confidence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

artdaq

The artdaq toolkit is a data-acquisition framework designed for high-energy physics experiments. It provides a flexible, reliable backbone for data transfers and has several locations where users can perform custom analysis tasks using the art framework.

Flumerfelt, EricL. [Fermi National Accelerator Lab↗

Multiprobe cosmology from the abundance of SPT clusters and DES galaxy clustering and weak lensing

Cosmic shear, galaxy clustering, and the abundance of massive halos each probe the large-scale structure of the Universe in complementary ways. We present cosmological constraints from the joint analysis of the three probes, building on the latest analyses of the lensing-informed abundance of clusters identified by the South Pole Telescope (SPT) and of the auto- and cross-correlation of galaxy position and weak lensing measurements (3 × 2 ⁢pt) in the Dark Energy Survey (DES). We consider the cosmological correlation between the different tracers and we account for the systematic uncertainties that are shared between the large-scale lensing correlation functions and the small-scale lensing-based cluster mass calibration. Marginalized over the remaining Λ cold dark matter (Λ ⁢CDM) parameters (including the sum of neutrino masses) and 52 astrophysical modeling parameters, we measure Ω m = 0.300 ± 0.017 and 𝜎 8 = 0.797 ± 0.026. Compared to constraints from Planck primary cosmic microwave background (CMB) anisotropies, our constraints are only 15% wider with a probability to exceed of 0.22 (1.2⁢𝜎) for the two-parameter difference. We further obtain 𝑆 8 ≡𝜎 8 ⁢(Ω m /0.3) 0.5 = 0.796 ± 0.013 which is lower than the Planck measurement at the 1.6⁢𝜎 level. The combined SPT cluster, DES 3 ×2 ⁢pt, and Planck datasets mildly prefer a nonzero positive neutrino mass, with a 95% upper limit ∑ 𝑚 𝜈 < 0.25 eV on the sum of neutrino masses. Assuming a 𝑤⁢CDM model, we constrain the dark energy equation of state parameter 𝑤 = −1.1⁢5$^{+0.23}_{−0.17}$ and when combining with Planck primary CMB anisotropies, we recover 𝑤 = −1.2⁢0$^{+0.15}_{−0.09}$, a 1.7⁢𝜎 difference with a cosmological constant. The precision of our results highlights the benefits of multiwavelength multiprobe cosmology and our analysis paves the way for upcoming joint analyses of next-generation datasets.

79 ASTRONOMY AND ASTROPHYSICS↗

Critical transverse compressive stresses of straight and bent CORC® wires with and without impregnation

CORC® wires are a promising superconductor for accelerator magnet applications. While their excellent uniaxial tensile properties have been well established, potential degradation under transverse compression remains a concern for accelerator magnets, in which transverse compression is a primary stress experienced by superconductors. To evaluate the critical transverse compressive stresses of rare-earth barium copper oxide conductors, we developed an experimental system that enables testing of samples both with and without impregnation in liquid nitrogen. Furthermore, because bending strain induced during coil winding may influence the critical compressive response of CORC® wires, the apparatus was also modified to allow testing under the bending condition. In this study wires were tested for five configurations: (1) straight, non-impregnated, (2) bent, non-impregnated, (3) straight, Stycast 2850 FT-impregnated, (4) bent, Stycast 2850 FT-impregnated, and (5) bent, paraffin wax-impregnated. The transverse pressures corresponding to 3% and 5% reductions in the critical current are reported. In conclusion, the effects of wire bending and impregnation on the critical transverse pressure are analyzed, and the implications for transverse stress levels in accelerator magnet conductors are discussed.

CORC® wire↗

otsdaq

otsdaq is a Ready-to-Use data-acquisition (DAQ) solution aimed at scaling down to test-beam, detector development, and other rapid-deployment scenarios; and scaling up through the development cycle to fullscale production and operation. otsdaq uses the artdaq DAQ framework under-the-hood, providing flexibility and scalability to meet evolving DAQ needs. otsdaq provides a library of supported front-end boards and firmware modules which implement a custom UDP protocol. Additionally, an integrated Run Control GUI and readout software are provided, preconfigured to communicate with otsdaq firmware.

Rivera, Ryan [Fermi National Accelerator Laborator↗

Search for nonvirialized axions with 3.3 − 4.2 μ ⁢eV mass at selected resolving powers

The Axion Dark Matter eXperiment is sensitive to narrow axion flows, given axions compose a fraction of the dark matter with a non-negligible local density. Detecting these low-velocity dispersion flows requires a high spectral resolution and careful attention to the expected signal modulation due to Earth’s motion. Here, we report an exclusion on the local axion dark matter density in narrow flows of ρ a ≳ 0.03 GeV/cm 3 and ρ a ≳ 0.004 GeV/cm 3 for Dine-Fischler-Srednicki-Zhitnitski and Kim-Shifman-Vainshtein-Zakharov axion-photon couplings, respectively, over the mass range 3.3−4.2 μeV. Measurements were made at selected resolving powers to allow for a range of possible velocity dispersions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved Dark Photon Sensitivity from a Superconducting-Radio-Frequency-Cavity Experiment

We report the refined dark-photon exclusion bound from Dark SRF’s pathfinder run. Our new result is driven by improved theoretical modeling of frequency instability in high-quality resonant experiments. Our analysis leads to a constraint that is an order of magnitude stronger than previously reported (corresponding to a signal-to-noise ratio that is 4 orders of magnitude larger). This result represents the world-leading constraint on non-dark-matter dark photons over a wide range of masses below 6 μ⁢eV and translates to the best laboratory-based limit on the photon mass 𝑚 𝛾 < 2.9 × 10 −48 g.

Kalia, Saarik [Univ. of Minnesota, Minneapolis, MN↗

Analysis of RF Surface Loss in a Planar 2D Qubit

The Josephson junction and shunt capacitor form a transmon qubit, which is the cornerstone of modern quantum computing platforms. For reliable quantum computing, it is important how long a qubit can remain in a superposition of quantum states, which is determined by the coherence time (T1). The coherence time of a qubit effectively sets the "lifetime" of usable quantum information, determining how long quantum computations can be performed before errors occur and information is lost. There are several sources of decoherence in transmon qubits, but the predominant one is generally considered to be dielectric losses in the natural oxide layer formed on the surface of the superconductor. In this paper, we present a numerical study of microwave surface losses in planar superconducting antennas of different transmon qubit designs. An asymptotic method for estimating the energy participation ratio in ultrathin films of nanometer scales is proposed, and estimates are given for the limits of achievable minimum RF losses depending on the electrical properties of the surface oxide and the interface of the qubit with the substrate material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved bound on nonlinear quantum mechanics using a cryogenic radio frequency experiment

There are strong arguments that quantum mechanics may be nonlinear in its dynamics. A discovery of nonlinearity would hint at a novel understanding of the interplay between gravity and quantum field theory, for example. As such, experiments searching for potential nonlinear effects in the electromagnetic sector are important. Here, in this study, we outline such an experiment, consisting of a stream of random bits (which were generated using Rigetti’s Aspen-M-3 chip) as input to an rf signal generator coupled to a cryogenic detector. Projective measurements of the qubit state, which is originally prepared in an equal superposition, serve as the random binary output of a signal generator. Thereafter, spectral analysis of the rf detector would yield a detectable excess signal predicted to arise from such a nonlinear effect. A comparison between the projective measurements of the quantum bits vs the classical baseline showed no power excess. This sets a new limit on the electromagnetic nonlinearity parameter |ε| ⪅ 1.15 x 10 -12 , at a 90.0% confidence level. This is the most stringent limit on nonlinear quantum mechanics thus far and an improvement by nearly a factor of 50 over the previous experimental limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dark Energy Survey Year 6 results: Galaxy-galaxy lensing

Here, we present galaxy-galaxy lensing measurements from the full six years of data from the Dark Energy Survey (DES Y6), covering 4031 deg 2 and used in the DES Y6 3×2 pt cosmological analysis. We use the Maglim++ lens sample, containing ∼9 million galaxies divided into six redshift bins, and the Metadetection source catalog, including ∼140 million galaxies divided into four redshift bins. The mean tangential shear signal achieves a total signal-to-noise ratio (S/N) of 173, corresponding to a 17% improvement over DES Y3. After applying the scale cuts used in the cosmological analysis, with 𝑅 min =6 Mpc/ℎ (4 Mpc/ℎ) for the linear (nonlinear) galaxy-bias model, the S/N is reduced to 75 (90). A comprehensive suite of validation tests demonstrates that the measurement is robust against observational and astrophysical systematics at the statistical precision required for the DES Y6 analysis. Although not used in the main cosmological analysis, we extract high signal-to-noise geometric shear-ratio measurements from the galaxy-galaxy lensing signal on small angular scales. These measurements provide an internal consistency check on the photometric redshift distributions and shear calibration used in the 3 ×2 pt analysis.

cosmological parameters↗

Measurement of correlated charge noise in superconducting qubits at an underground facility

The charge environment of superconducting qubits may be studied through the introduction of controlled, quantified amounts of ionizing radiation. We measure space- and time-correlated charge jumps on a four-qubit device, operating 107 meters below the Earth’s surface in a low-radiation, cryogenic facility designed for the characterization of low-threshold particle detectors. The rock overburden of this facility reduces the cosmic ray muon flux by over 99% compared to laboratories at sea level. Combined with 4π coverage of a movable lead shield, this facility enables quantifiable control over the flux of ionizing radiation on the qubit device. Long-time-series charge tomography measurements on these weakly charge-sensitive qubits capture discontinuous jumps in the induced charge on the qubit islands, corresponding to the interaction of ionizing radiation with the qubit substrate. The rate of these charge jumps scales with the flux of ionizing radiation on the qubit package, as characterized by a series of independent measurements on another energy-resolving detector operating simultaneously in the same cryostat with the qubits. Using lead shielding, we achieve a minimum charge jump rate of $0.19^{+0.04}_{-0.03}$ mHz, almost an order of magnitude lower than that measured in surface tests, but a factor of roughly seven higher than expected based on reduction of ambient gammas alone. We operate four qubits for over 22 consecutive hours with zero correlated charge jumps at length scales above three millimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Terahertz near-field imaging of sidewall-induced losses in superconducting qubits

Correlating superconducting qubit performance with advanced materials analysis is a key strategy for improving coherence. Existing diagnostics for key properties, such as dielectric loss, structural discontinuity, and interface heterogeneity, often rely on destructive electron microscopy or low-throughput millikelvin measurements. Here, in this study, we demonstrate noninvasive terahertz (THz) nano-imaging/spectroscopy of encapsulated niobium transmon qubits as a high-throughput proxy for performance evaluation. We identify large variations in sidewall near-field signals, implicating sidewall loss and discontinuity as major coherence limiters, and also use THz hyperspectral line scans to probe dielectric responses and field participation at Al junction interfaces.

Kim, Richard H. J. [Ames Laboratory (AMES), Ames, ↗

A sub-5 ps jitter time-to-digital converter ASIC with back-gate delay tuning in 22 nm CMOS

We present the design of a Time-to-Digital Converter (TDC) ASIC together with performance characterization results at cryogenic temperature (6-8 K), and at room temperature using emulated Low-Gain Avalanche Detector (LGAD) signals. The TDC design uses a two-step architecture with a ring-oscillator based counter and a Vernier delay line fine TDC. The TDC is implemented in an FD-SOI process, and back-gate tuning is used not only to correct threshold variation due to cryogenic operation, but also as a novel way to tune TDC delay elements with very little overhead. Using this technique, we demonstrate a design with very low power (0.5 mW) and area (0.003 mm 2 ). We present test results using the Fermilab Constant Fraction Discriminator (FCFD) ASIC to produce discriminated signals from an internal charge injection mechanism that mimics the waveform and signal amplitude of minimum ionizing particles impinging on LGAD sensors. We characterize the time precision of the full system and verify that the TDC ASIC contributes a negligible amount to the total system time precision, fully consistent with the expected jitter contribution of less than 5 ps. In conclusion, the results presented here demonstrate the utility of our TDC for applications in physics and quantum communications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗